| Sl No | Description | Qty | Unit | AADESH ELECTRICAL AND CONTRACTORS L1 | SAWANT ENGINEERS L2 |
|---|---|---|---|---|---|
| 1.00Servicing of DG Set | |||||
| 1.01 | Carrying out servicing of DG set from 1010 kVA with/without AMF panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, carry out visual nspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking V belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of AVR, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator and Submit the servicing report to engineer in charge. (Non Comprehensive) as per specification no. GEN-SER-AMC | 12 | Per Job | 5,400 ₹64,800 Lowest | 7,987 ₹95,844 |
| 1.02 | Carrying out servicing of DG set upto 50 kVA with/without AMF panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking V belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of AVR, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator and Submit the servicing report to engineer in charge. (Non Comprehensive) as per specification no. GEN-SER-AMC | 24 | Per Job | 2,500 ₹60,000 | 2,016 ₹48,384 Lowest |
| 1.03 | Carrying out servicing of DG set from 62.5 kVA to 200 kVA with/without AMF panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking V belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of AVR, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator and Submit the servicing report to engineer in charge. (Non Comprehensive) as per specification no. GEN-SER-AMC | 12 | Per Job | 4,000 ₹48,000 | 2,617 ₹31,404 Lowest |
| 2.00Supplying and erecting materials to carrying out Servicing of DG Set | |||||
| 2.01 | Topping up new lubricating oil 15W/40 grade of approved make as per IS 12656 : 2014 | 50 | Litre | 350 ₹17,500 Lowest | 357 ₹17,850 |
| 2.02 | Topping up new glycol based coolant 50/50 with operating range from 118°C to -37°C of approved make | 25 | Litre | 350 ₹8,750 Lowest | 378 ₹9,450 |
| 2.03 | Supplying & erecting V-Belt of all types and lengths, adjust tension as per requirements from generator manufacturer suitable for DG set upto 100kVA | 12 | Number | 1,250 ₹15,000 Lowest | 2,089 ₹25,068 |
| 2.04 | Supplying and erecting lub oil filter element along with sealing rings, gasket etc complete suitable for DG Set upto 62.5 kVA. | 6 | Number | 900 ₹5,400 | 357 ₹2,142 Lowest |
| 2.05 | Supplying and erecting fuel filter along with sealing rings, gasket, primary filter and water separator etc complete suitable for DG Set upto 62.5 kVA. | 6 | Number | 1,000 ₹6,000 | 442 ₹2,652 Lowest |
Tender Value
₹10.7 L
EMD Value
₹10,700
Closing Date
30 Jun 2025, 11:00 amClosed
Executive Engineer MIDC Division Kolhapur
1st Floor MIDC Office Udyog Bhavan Nagala Park Kolhapur
M and R to Combined WSS at Kagal Hatkanagale Gokul-Shirgaon and Shiroli Indl. Area... Repairs and Annual Maintenance Contract for Diesel Generator Sets 2nd Call
2025_MIDC_1191564_1
16 of 2025
Open Tender
Electrical Works
Item Rate
Kolhapur
Please refer Tender Document
8 documents required · 8 mandatory
₹5,900
₹10,700
21 Aug 2025
19 Jun 2025
1 Jul 2025
19 Jun 2025
30 Jun 2025
25 Jun 2025
19 Jun 2025 - 21 Jun 2025
Amount
Servicing of DG Set
Carrying out servicing of DG set from 1010 kVA with/without AMF panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, carry out visual nspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking V belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of AVR, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator and Submit the servicing report to engineer in charge. (Non Comprehensive) as per specification no. GEN-SER-AMC
Carrying out servicing of DG set upto 50 kVA with/without AMF panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking V belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of AVR, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator and Submit the servicing report to engineer in charge. (Non Comprehensive) as per specification no. GEN-SER-AMC
Carrying out servicing of DG set from 62.5 kVA to 200 kVA with/without AMF panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking V belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of AVR, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator and Submit the servicing report to engineer in charge. (Non Comprehensive) as per specification no. GEN-SER-AMC
Supplying and erecting materials to carrying out Servicing of DG Set
Topping up new lubricating oil 15W/40 grade of approved make as per IS 12656 : 2014
Topping up new glycol based coolant 50/50 with operating range from 118°C to -37°C of approved make
Supplying & erecting V-Belt of all types and lengths, adjust tension as per requirements from generator manufacturer suitable for DG set upto 100kVA
Supplying and erecting lub oil filter element along with sealing rings, gasket etc complete suitable for DG Set upto 62.5 kVA.
Supplying and erecting fuel filter along with sealing rings, gasket, primary filter and water separator etc complete suitable for DG Set upto 62.5 kVA.
Supplying and erecting stop solenoid assembly 12V/24V single coil energized to run with or without primary etc complete suitable for DG set upto 125 kVA.
Supplying and erecting Air cleaner/Air filter element suitable for DG set upto 40 kVA
Supplying and erecting Air cleaner/Air filter element suitable for DG set from 50 kVA to 125 kVA
Supplying, erecting and testing main stator powered excited Automatic Voltage Regulator (AVR) with sensing input voltage range: 95 V - 122 V /190 V AC - 264 V AC 1 Phase 2 wire, frequency range 50-60 Hz and output voltage max 90 V DC continuous current 4 A, transient current 6 A for 10 second with minimum resistance of 15 ohm, AVR response time of 20 ms etc. complete suitable for DG set as per Specification GEN-SER-AVR
Supplying and erecting set of engine safety unit suitable for DG set upto 125 kVA as per specification no
Supplying and erecting SMPS based Battery Charger input voltage 230 V A.C. & output voltage 24 V DC, charging current 20A suitable to charge DG set Battery
Supplying, erecting, testing and commissioning microcontroller based digital line voltage monitor 3 phase 4 wire 2 CO output relay suitable to operate on AC voltage for DG set.
Topping up Distilled water for Battery
Supplying & erecting of BASE Card for 1010 KVA DG set Controller P.C.B. Assembly No.-327-1601
Supplying & erecting of Oil Filter with "O" Ring for 1010 KVA DG set
Supplying & erecting of Fuel Filter with "O" Ring for 1010 KVA DG set
Supplying & erecting of Bypass Filter with "O" Ring for 1010 KVA DG set
Supplying & erecting of Set of V Belt for 1010 KVA DG set
Supplying & Topping of Engine Oil Valvoline Premium Blue for 1010 KVA DG set
Supplying & erecting AVR Assembly for 1010 KVA DG set with sensing input voltage range: 264 V AC - 440 V AC 1 Phase 2 wire, frequency range 50-60 Hz and output voltage max 120 V DC continuous current 2.7 A, transient current 6 A for 10 second with minimum resistance of 15 ohm, AVR response time of 10 ms etc. complete suitable for DG set as per Specification GEN-SER-AVR
Supplying & erecting of Battery Charger for 1010 KVA DG set
Supplying, erecting, testing and commissioning controller Assembly suitable to operate on AC voltage for 62.5 KVA DG set.
Making Cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).
SECTION 1 - PM [PUMPS]
Providing, erecting and giving test of submersible pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump.
Submersible Pump set 100 mm dia (with Polypropylene /Noryl Impeller) up to 20 stages
Supplying & erecting ON LOAD change over switch 4 Pole, 415V, 63A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3 as per specification no. SW-SWR/COS.
Supplying and erecting Boss water tank of capacity 10000 litres
SAWANT ENGINEERS (BID ID -6736883)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .