Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.0 L+₹2.0 L (28.4%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹9.5 L+₹2.5 L (35.9%)Rejected-Finance NO 12 25 26 KATHIRAVAN NAGAR MAHALINGAPURAM PO POLLACHI COIMBATORE 642 002 | COIMBATORE | TAMIL NADU | 642002 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹10.7 L+₹3.7 L (53.1%)Rejected-Finance E 27 CWE WELLINGTON | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
23 Apr 2022, 6:00 pmClosed
GARRISON ENGINERR AIRFORCE THANJAVUR
GARRISON ENGINERR AIRFORCE THANJAVUR
REPAIR / OVERHAULING / SERVICING AND REPLACEMENT OF WORNOUT UNSERVICEABLE SPARES TO COOLING APPLIANCES AC PLANT / RO PLANT / AQUA GUARD AND CONNECTED ACCESSORIES AT AIRFORCE STATION THANJAVUR
2022_MES_515055_1
8854/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
THANJAVUR
AS PER NIT
6 documents required · 6 mandatory
₹500
GARRISON ENGINERR AIRFORCE THANJAVUR
₹20,000
Yes
19 May 2022
24 Mar 2022
25 Apr 2022
24 Mar 2022
23 Apr 2022
9 Apr 2022
Amount
Supply and fixing in replacement condensor / chiller water pressure switch as per existing make and size complete all as specified.
Filling refrigerant gas R - 407C in central AC plant of capacity 25 TR capacity including vaccume by using vaccume pump and ckeking of leakages by using halide torch and brazing the leakage portion etc complete all as specified.
Supply and fix in replacement micro computer control system including disconnecting electrically / electronically complete all as specified.
Supply and fix in replacement refrigerant gas pressure switch (High/Low) universal type complete all as specified.
Supply and fix in replacement thermostatic expantion valve suitable for 25 TR central AC Plant complete all as specified.
Supply and fix in replacement butterfly valve of size 50mm PN - 1.6 complete all as specified.
Supply and fix in replacement brass ball valve of size 25mm complete all as specified.
Supply and fixing in replacement of drain out nipple for cooling tower as per existing make and size complete all as specified.
Supply and fix in replacement pressure guage 4 inch dial 0 - 14 KGs rating complete all as specified.
Supply and fix in replacement temparature guage 4 inch dial 0 - 100 degree centigade rating complete all as specified.
Dismantling of existing defective induction motor of the capacity 1.5 HP of any make from the foundation, disconnecting the electric connection, coupling pulley, and taking out to work shop, cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with super enamelled solid copper conductor ( winding wire) complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor including replacement of ball bearings and repairing /servicing the multistage centrifugal pump set model No D920/20 by dismantling the pump from induction motor, opening for inspection, replacing the worn out parts like pump shaft, impellers, gland bush, bearings gland bolts and nuts,gland packing, gasket, water seal etc including repaires to pump shaft by remetaling, grinding, polishing and reassembling the same and replasing the rusted nuts, bolts washers etc and testing complete all as specified.
Supply and fix in replacement AHU belt B - 111 complete all as specified.
Supply and fix in replacement strip for heater 1.5 KW capacity complete all as specified.
Supply and fix in replacement power contactor 40 amps capacity with 1 NC complete all as specified.
MCB, Tripple pole & neutral, 63 amps, 415 volts, ‘C’ curve, 10 KA complete all as specified.
MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA complete all as specified.
Supply and fix in replacement single pole and neutral enclosure with two pin and earth plug and socket complete with single pole MCB 20 amps capacity complete all as specified.
Supply and fix in replacement metal clad plug two pin and earth complete all as specified.
Sub main wiring with 2 run of 4 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant low smoke cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 2.5 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and including 20 mm dia PVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified.
Supply and fix in replacement of new compressor including pumping out oil, cleaning the refrigeration system with Co2 and charging refrigerant gas (M-22/F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning suitable for 1.5 - 2.0 TR capacity split type Air conditoner complete all as specified.
Supply and fix in replacement of new compressor including pumping out oil, cleaning the refrigeration system with Co2 and charging refrigerant gas (M-22/F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning suitable for refrigerator 180 to 310 ltrs capacity complete all as specified
Supply and fix in replacement of new compressor including pumping out oil, cleaning the refrigeration system with Co2 and charging refrigerant gas (M-22/F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning suitable for Deep freezer for 200 to 320 ltrs capacity complete all as specified.
Supply and fix in replacement of new compressor including pumping out oil, cleaning the refrigeration system with Co2 and charging refrigerant gas (M-22/F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning suitable for Water cooler 80/40 capacity. Note for Sl item No 20 to 23:- Rate deemed to be inclusive of filling/Gas charging.
Voltage Stabilizer 5 KVA capacity
Voltage Stabilizer 3/4 KVA capacity
Voltage Stabilizer 01 KVA capacity
Supply and fix in replacement PCB (Printed circuit board) suitable for 1.5/2.0 Ton of split type type Air conditioners complete all as specified.
Material and labour for Leak test with Co2/ Nitrogen gas arrest leakage with brazing of copper pipe and charging refrigerant gas R- 410/ R-22 for AC capacity 1.5/2 TR Split type Air conditioner complete all as specified.
Material and labour for Leak test with Co2/ Nitrogen gas arrest leakage with brazing of copper pipe and charging refrigerant gas R-12 /R-134 for following cooling appliances.
Refrigerator
Water Cooler
Deep freezer
Rigid PVC flexible hose of 15 mm dia 2.5 mtr length with all acessories fixed on wall /ceiling/ roof etc with suitable GI saddles and screws for connect with split type AC/water cooler as drain pipe complite all as specified.
Motor starter,25A,2 module for AC including madular metal flush box with suitable screws for housing the starter complete all as specified.
Supply and fix with replacement new fan leaf unit suitable for Airconditioner of capacity 1.5TR/2TR complete all as secified.
Supply and replace with new remote control unit suitable for Airconditioner complete all as specified.
Supply and replace with new condenser coil unit made of copper suitable for split Airconditioner of following capacity.
1.5 ton capacity
2.0 ton capacity
Supply and fix in repair Starting capacitors for following cooling appliances
Split type Air Conditioner
Refrigerator
Deep Freezer
Water Cooler
Supply and fix in repair Running capacitors for following cooling appliances
Split type Air Conditioner
Refrigerator
Deep Freezer
Water Cooler
Supply and fix in repair Thermostatic switch for following cooling appliances
Split type Air Conditioner
Refrigerator
Deep Freezer
Water Cooler
Supply and fix in repair Fan Motor for following cooling appliances
Split type Air Conditioner (Outdoor)
Refrigerator
Deep Freezer
Water Cooler
Supply and fix in repair indoor unit blower Fan Motor for 1.5/2 Ton Split type Air conditioner complete all as specified.
Supply and fix in replacement suction valve 1.5/2 TR capacity complete all as specified.
Supply and fix in replacement discharge valve for Split type Air conditioner, 1.5/2 TR capacity complete all as specified.
Supply and fix in replacement flare nut of size 5/8 inch for Split type Air conditioner complete all as specified.
Supply and fix in replacement of flare nut of size 1/2 inch for Split type Air conditioner complete all as specified.
Supply and fix in replacement flare nut of size 1/4 inch for Split type Air conditioner complete all as specified.
Supply and fix in replacement flare nut of size 3/8 inch for Split type Air conditioner complete all as specified.
Supply and fix in replacement mounting stad for split type Airconditioner 1.5/2 TR capacity complete all as specified. .
Supply and fix in replacement PCB (Printed circuit board) suitable for Indoor 1.5/2.0 TR Inverter split type Air conditioners complete all as specified and directed.
Supply and fix in replacement PCB (Printed circuit board) suitable for Outdoor 1.5/2.0 TR Inverter split type Air conditioners complete all as specified and directed.
Supply and fix in replacement PCB (Printed circuit board) suitable for refrigerator any type any size complete all as specified and directed.
Supply and fix in replacement indoor evaparator unit 1.5/2 TR split AC complete all as specified
Supply and fix in replacement Outdoor condensing unit 1.5/2 TR split tye Airconditioner complete all as specified.
Supply and fixing in replacement voltage stabilizer 4 KVA range 170 to 260 Volts, output voltage 230 volts AC supply 50 HZ having low and high voltage protection, intelligent time delay system, wall mounting type including mounting accessories time delay 180 seconds +/- 20 seconds as initial time delay complete all as specified.
Material and labour for servicing / maintenance of water purifier of make Aquaguard / Aquasure by replacing unservicble spares such as filters, UV lamps and power circuit boards complete and make the unit in serviceable condition to the entire satisfaction of Engineer-in-charge complete all as specified.
Material and labour for servicing /maintenance of water purifier with hot, normal and cold water dispensing unit with uv technology and microprocessor controlled monitoring system in a single compact unit with built in storage tank of any capacity including servicing and cleaning inlet connection, drain connections and PF candle,uv lamp with housing, cooling compressor, uv transforfer,main pcb ,solenoid valve,heater tank assembly for every six months and two times for one year complete all as specified and as directed.
Material and labour for taking down unserviceable items and supply and fix new items of the followings for water Doctor including testing etc complete all as specifie.
CMOS MAIN PCB
D2 PS PCB (SINGLE TANK)
TRANSFORMER
SOLENOID VALVE
TWO WAY VALVE
O3 GENERATOR
COMPRESSOR
COMPRESSOR RELAYS
COMPRESSOR FAN MOTORS
COMPRESSOR CAPACITORS
THERMOSTAT (COOLER)
INJECTOR
HEATER ASSY (Tank)
HEATER FILAMENT
THERMOSTAT(HEATER)
NEON LAMP
PF CANDLE
PF CANDLE – 20”
CERAMIC CANDLE
A/C CARBON WITH CARTRIDGE
PF BOWL & CAPPF BOWL &CAP
A.D.BOTTLE ASSY
SUPER COOL
Rajapriyaconstruction
UNIQUE INDIA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .