Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹17,900
Closing Date
21 Jul 2026, 12:00 pm
HOD Civil works and maintances SMP
Goa shipyard limited
Supply, Installation, testing and Commissioning of High mast Light, Near New Vaddem Railway Bridge under CSR 2026
2026_GSL_99713_1
CIVIL/01/GSL/CE/ADS/ETN-270
Open Tender
Civil Works
60 days
Goa shipyard limited
As per attached PQ
8 documents required · 8 mandatory
₹590
Yes
Goa shipyard limited
₹17,900
Yes
1 Jul 2026
1 Jul 2026
21 Jul 2026
1 Jul 2026
21 Jul 2026
1 Jul 2026
1 Jul 2026 - 18 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S 355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OHPL/ HM (excluding luminaries).
Make: Reputed make. Note:Bidder has to submit the make list and model of the highmast and associated items prior to procurement and approval to be obtained from the dealing officer. | 1 | Set | - | - |
| 2 | Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, IP 54 and IK10 protection, 25 A TP contactor for automatic switching of luminaires, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete.
Note: Rate inclusive of foundation | 1 | Job | - | - |
| 3 | Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast). | 1 | Each | - | - |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm. | 25 | Meter | - | - |
| 5 | Supplying, laying, termination and commisoning of Armoured PVC/XLPE 1100 V cable 4 core 25 sq.mm aluminium including Lugs. Make: Polycab / Finolex / RR Kabel | 50 | Meter | - | - |
| 6 | Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole/reccess. | 25 | Meter | - | - |
| 7 | Earthing with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangment and watering pipe of 2.7 meter long with funnel top including wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results etc. with charcoal/coke and salt as required. | 2 | Set | - | - |
| 8 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm). | 50 | Meter | - | - |
| 13 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 52 DELHI SCHEDULE OF RATES (E&M)-2025 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | 12 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
V.pdf
Tender Documents • 0.35 MB
PQ.pdf
Tender Documents • 0.02 MB
p.pdf
Additional Documents • 0.21 MB
BOQ_109297.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid