Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
27 Nov 2021, 6:00 pmClosed
Shri Kislay Kishore, IDSE
GE (AFA) Hyderabad PIN-500043
Special repair/ Replacement of BER HPSV/ Metal halide security lights/ TMS lights with LED lights at AFA Hyderabad
2021_MES_485112_1
8191/E8
Open Tender
Civil Works
Item Rate
GE (AFA) Hyderabad
As per tender documents
4 documents required · 4 mandatory
₹500
Yes
GE (AFA) Hyderabad
₹50,000
Yes
28 Dec 2021
29 Oct 2021
29 Nov 2021
29 Oct 2021
27 Nov 2021
13 Nov 2021
29 Oct 2021 - 12 Nov 2021
Amount
Taking down carefully old burnt out sub main wiring and making good distrubed surfaces to match with existing finish all as directed.
M&L for Sub Main wiring with two runs of 2.5sq.mm. (nominal area) single core PVC insulated unsheathed FRLS cable multi-stranded copper conductor 1100 Volts drawn through and including in stove enamelled medium grade steel conduit of suitable size but not less than 20mm dia, with all fittings, on surfaces of wall / ceiling / roof duly fixed with fixing clamps including MS box of thickness not less than 1.2mm, for fixing of switches and duly earthed with 01 run of 2.5sq.mm. (nominal area) single core PVC insulated unsheathed FRLS cable multi-stranded copper conductor cable green in colour as continuous earthing wire complete all as specified and directed by Engineer-in-Charge. Note (i) : Necessary stove enamelled steel conduit junction boxes for identifying junction as required on site/directed by Engr-in-charge for sub main wiring work with dummy plates shall deemed to be included in the quoted rate. (ii) 3runs of cable and one run of conduit shall be measured as one unit. (iii) The wiring shall be done strictly as per IS standard (iii) Height of the TMS is 5mtr approx.
M&L for Sub Main wiring with two runs of 4.0sq.mm. (nominal area) single core PVC insulated unsheathed FRLS cable multi-stranded copper conductor 1100 Volts drawn through and including in stove enamelled medium grade steel conduit of suitable size but not less than 20mm dia, with all fittings, on surfaces of wall / ceiling / roof duly fixed with fixing clamps including MS box of thickness not less than 1.2mm, for fixing of switches and duly earthed with 01 run of 4.0sq.mm. (nominal area) single core PVC insulated unsheathed FRLS cable multi-stranded copper conductor cable green in colour as continuous earthing wire complete all as specified and directed by Engineer-in-Charge. Note (i) : Necessary in stove enamelled steel conduit junction boxes for identifying junction as required on site/directed by Engr-in-charge for sub main wiring work with dummy plates shall deemed to be included in the quoted rate. (ii) 3runs of cable and one run of conduit shall be measured as one unit. (iii) The wiring shall be done strictly as per IS standard (iii) Height of the TMS is 5mtr approx.
M&L for Sub Main wiring with two runs of 6.0sq.mm. (nominal area) single core PVC insulated unsheathed FRLS cable multi-stranded copper conductor 1100 Volts drawn through and including in stove enamelled medium grade steel conduit of suitable size but not less than 40mm dia, with all fittings, on surfaces of wall / ceiling / roof duly fixed with fixing clamps including MS box of thickness not less than 1.2mm, for fixing of switches and duly earthed with 01 run of 6.0sq.mm. (nominal area) single core PVC insulated unsheathed FRLS cable multi-stranded copper conductor cable green in colour as continuous earthing wire complete all as specified and directed by Engineer-in-Charge. Note (i) : Necessary in stove enamelled steel conduit junction boxes for identifying junction as required on site/directed by Engr-in-charge for sub main wiring work with dummy plates shall deemed to be included in the quoted rate. (ii) 3runs of cable and one run of conduit shall be measured as one unit. (iii) The wiring shall be done strictly as per IS standard (iii) Height of the TMS is 5mtr approx.
M&L for Sub Main wiring with two runs of 10sq.mm. (nominal area) single core PVC insulated unsheathed FRLS cable multi-stranded copper conductor 1100 Volts drawn through and including in stove enamelled steel conduit of suitable size but not less than 40mm dia, with all fittings, on surfaces of wall / ceiling / roof duly fixed with fixing clamps including MS box of thickness not less than 1.2mm, for fixing of switches and duly earthed with 01 run of 10.0sq.mm. (nominal area) single core PVC insulated unsheathed FRLS cable multi-stranded copper conductor cable green in colour as continuous earthing wire complete all as specified and directed by Engineer-in-Charge. Note (i) : Necessary in stove enamelled steel conduit junction boxes for identifying junction as required on site/directed by Engr-in-charge for sub main wiring work with dummy plates shall deemed to be included in the quoted rate. (ii) 3runs of cable and one run of conduit shall be measured as one unit. (iii) The wiring shall be done strictly as per IS standard (iii) Height of the TMS is 5mtr approx.
M&L for Sub Main wiring with two runs of 16.0sq.mm. (nominal area) single core PVC insulated unsheathed FRLS cable multi-stranded copper conductor 1100 Volts drawn through and including in stove enamelled steel conduit of suitable size but not less than 40mm dia, with all fittings, on surfaces of wall / ceiling / roof duly fixed with fixing clamps including MS box of thickness not less than 1.2mm, for fixing of switches and duly earthed with 01 run of 16.0sq.mm. (nominal area) single core PVC insulated unsheathed FRLS cable multi-stranded copper conductor cable green in colour as continuous earthing wire complete all as specified and directed by Engineer-in-Charge. Note (i) : Necessary in stove enamelled steel conduit junction boxes for identifying junction as required on site/directed by Engr-in-charge for sub main wiring work with dummy plates shall deemed to be included in the quoted rate. (ii) 3runs of cable and one run of conduit shall be measured as one unit. (iii) The wiring shall be done strictly as per IS standard (iii) Height of the TMS is 5mtr approx.
Taking old unsv HPSV/MH Light Fittings any type any size and all as directed.
Supply, installing, testing and commissioning of High bay industrial LED Luminaire 150 Watt Power factor: 0.95, Power Consumption: 150 Watts, Rated Liminous Lux-15000Lm, Color Temperature-6000K(WH) complete with all fixing accessories, clamps, nuts, bolts, and necessary connection from nearby existing ceiling rose by providing 3 core multiflexible round copper wire of size 1.5 Sqmm including Light grade GI Pipe 20mm dia up to 2mtr long with clamps and nut bolts complete all as specified and directed. Make : LUKER CAT NO- LHBY150 or equivalent Note :(i) Height of the TMS is 5mtr approx.
S & F LED Flood light fitting 1 X 150 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame welded on `C channel complete with nut bolts and washers , IP - 66 protection, uniform distribution,including angle iron frame complete all as specified and as directed. Make:- LUKER CAT NO- LFLSL150. or equivalent
S & F LED Flood light fitting 1 X 50 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame welded on `C channel complete with nut bolts and washers , IP - 66 protection, uniform distribution,including angle iron frame complete all as specified and as directed. Make: LUKER CAT NO: LFLSL 50 or equivalent
S & F (in repairs) MCB DB,double door 8 way triple pole vertical type 415 volts 50 Hz AC supply suitable for 4 pole MCCB incomer, fixed to the existing wall (concealed/surface) after removing the existing un serviceable MCB DB and reconnecting the electrical connections and making good the disturbed surface of wall to perfectly match with the exsting wall complete all as specified and as directed. Note :- MCCB and MCB will be measured and paid separately under relavant items. Make:- Havells or equivalent.
S & F (in repairs) MCCB 4 pole 160 Amps, 36KA breaking capacity, 415Volts 3-phase supply complete all as specified and as directed. Make: Havells IHLGHF0160 & or equivalent all as specified and as directed.
S & F (in repairs) MCCB 4 pole 63Amps, 16KA breaking capacity, 415Volts 3-phase supply complete all as specified and as directed. Make: Havells IHLGHF0063 or equivalent all as specified and as directed.
S & F (in repairs) MCB SP 6 to 32 A 10 KA rupturing capacity complete all as specified and as directed. Make:- Havells or equivalent.
Srinivash Engineers
Dwarka Pershad Radhey Ramanlal
L and S ENTERPRISES
Srinivasa Consructions
M/s Amit Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .