Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹11.9 LQualified Make: NA
Model: RVS 06P 76 OFFICE SHOP NO 76 RAI UDYOG BUILDING NEAR WOX COOLER KORADI ROAD NAGPUR 440030 97634 NAGPUR MAHARASHTRA 440030 | NAGPUR | MAHARASHTRA | 440030 | Make: NA
Model: RVS 06P | L1 | Qualified | |
| 2 | L2₹14.8 L+₹2.9 L (24.6%)Qualified Make: ASKA
Model: ASKA MFCF-10-POWDER-P6 482 SIR GANGA RAM HOSPITAL SQUARE SHANKAR ROAD CENTRAL DELHI DELHI 110060 | CENTRAL DELHI | DELHI | 110060 | Make: ASKA
Model: ASKA MFCF-10-POWDER-P6 | L2 | Qualified | |
| 3 | L3₹14.9 L+₹3.0 L (24.8%)Qualified Make: ANSH
Model: ANSH AS-6P FLAT NO 571 RADHIKA APPARTMENT POCKET 1 SECTOR 14 DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | Make: ANSH
Model: ANSH AS-6P | L3 | Qualified | |
| 4 | Disqualified Make: SAFETY PLUS
Model: FIRE EXTINGUSHER N A NAZMA MANZIL KAZMI BEGUM COLONY GUZRI BAZAR PATNA CITY BIHAR 800008 | PATNA | BIHAR | 800008 | Make: SAFETY PLUS
Model: FIRE EXTINGUSHER | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
16 Oct 2018, 10:00 amClosed
Portable Fire Extinguishers BS EN Standard Based Portable Fire Extinguishers BS EN Standard Based ( 34 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Genric Conformity to Standard "EN 3-7 + A1: 2007 & EN 3-8;2006 with latest amdnt. " "EN 3-7 + A1: 2007 & EN 3-8;2006 with latest amdnt. " Type Stored Pressure Stored Pressure
Gas Cartridge Type Constructional Extinguishing Media Powder Based Water Based
Foam Based
Wet Chemical Based
Powder Based
Carbon Dioxide Based
Clean Agents
Halon Type Extinguishers Foam Based Extinguishing Media NA * Powder Based Extinguishing Media ABC Powder * Clean Agents Based Extinguishing Media NA * Halon Based Extinguishing Media ( as per European na * 1/5 Council regulation 2037/2000 concerning use of halons) ( If not applicable write NA) Water Based Extinguishing Media ( If not applicable write NA) na * Wet Chemical Based Extinguishing Media ( If not applicable write NA) na * CO2 Based Extinguishing Media ( If not applicable write NA) na * Nominal Permitted Charge for Powder Based Fire Extinguisher (kg) 6 1
2
3
4
6
9
12
NA Nominal Permitted Charge for Water Based
Wet Chemical Fire Extinguisher (Ltrs) NA 2
NA Nominal Permitted Charge for C02 Based Fire Extinguisher (kg) NA 2
5
NA Nominal Permitted Charge for Halon Based Fire Extinguisher (kg) NA 1
NA Nominal Permitted Charge for clean Agents Based Fire Extinguisher (kg) NA 1
NA Weight of Filled Portable Fire Extinghuisher (kg) 8.5 * Rechargable Yes * Fire Extinguisher Suitable for Class -C Fire true * Fire Extinguisher Suitable for electrical Fire true * Cylinder/Vessel Material HDPE with Aramid Winding ( Kevlar ) Non- Corrosive Type HDPE with Aramid Winding ( Kevlar ) Non- Corrosive Type
2/5 Stainless Steel
Mild Steel
Aluminium Alloy Warranty for the Complete Product 10 1
10 (or higher) Performance Expellant Medium N2 Based CO2 Based
N2 Based
Helium Based
Air Based
Argon Based Suitable for Class -A fire ratings as per EN 3-7 43A * Class -B Fire Rating for (Powder Based
Foam Based CO2 based Fire Extinguisher 233B * Fire Rating for Class -F NA * Operating Temperature ( -30° C≤ N >=60° C ) -30° C to + 60° C * Service Pressure 12 * Burst Pressure 55 * Minimum Discharge Time (seconds) required as per EN Standard 15 * Actual Discharge Time in seconds 20 * Certification Shelf Life (Life Cycle) of the Fire Extinguisher 20 year * Marine Equipment Directive(MED) Approved false * CE Certification from EU Notified Body Yes * CE Identification Number of the Notified Body (Must Declare) 0029 * Availability of Test Report from Central Govt./NABL/ILAC acredited lab to prove confirmity to specification Yes * Test Report No - * Test Report Date - * Name of the Lab - * Address of the Lab - * * Bold specifications are the golden parameters. 3/5 Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Chennaiah M 560075
Aeronautical Development Establishment Defence R and D Organisation
Ministry of Defence
Government of India
Suranjandas Road New Thippasandra 34 30
693547
GEM/2018/B/98144
Portable Fire Extinguishers BS EN Standard Based
30 days
Karnataka; Bengaluru Urban
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Portable Fire Extinguishers BS EN Standard Based Portable Fire Extinguishers BS EN Standard Based ( 34 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Genric Conformity to Standard "EN 3-7 + A1: 2007 & EN 3-8;2006 with latest amdnt. " "EN 3-7 + A1: 2007 & EN 3-8;2006 with latest amdnt. " Type Stored Pressure Stored Pressure | - | - | - |
| Gas Cartridge Type Constructional Extinguishing Media Powder Based Water Based | - | - | - |
| Foam Based | - | - | - |
| Wet Chemical Based | - | - | - |
| Powder Based | - | - | - |
| Carbon Dioxide Based | - | - | - |
| Clean Agents | - | - | - |
| Halon Type Extinguishers Foam Based Extinguishing Media NA * Powder Based Extinguishing Media ABC Powder * Clean Agents Based Extinguishing Media NA * Halon Based Extinguishing Media ( as per European na * 1/5 Council regulation 2037/2000 concerning use of halons) ( If not applicable write NA) Water Based Extinguishing Media ( If not applicable write NA) na * Wet Chemical Based Extinguishing Media ( If not applicable write NA) na * CO2 Based Extinguishing Media ( If not applicable write NA) na * Nominal Permitted Charge for Powder Based Fire Extinguisher (kg) 6 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 6 | - | - | - |
| 9 | - | - | - |
| 12 | - | - | - |
| NA Nominal Permitted Charge for Water Based | - | - | - |
| Wet Chemical Fire Extinguisher (Ltrs) NA 2 | - | - | - |
| NA Nominal Permitted Charge for C02 Based Fire Extinguisher (kg) NA 2 | - | - | - |
| 5 | - | - | - |
| NA Nominal Permitted Charge for Halon Based Fire Extinguisher (kg) NA 1 | - | - | - |
| NA Nominal Permitted Charge for clean Agents Based Fire Extinguisher (kg) NA 1 | - | - | - |
| NA Weight of Filled Portable Fire Extinghuisher (kg) 8.5 * Rechargable Yes * Fire Extinguisher Suitable for Class -C Fire true * Fire Extinguisher Suitable for electrical Fire true * Cylinder/Vessel Material HDPE with Aramid Winding ( Kevlar ) Non- Corrosive Type HDPE with Aramid Winding ( Kevlar ) Non- Corrosive Type | - | - | - |
| 2/5 Stainless Steel | - | - | - |
| Mild Steel | - | - | - |
| Aluminium Alloy Warranty for the Complete Product 10 1 | - | - | - |
| 10 (or higher) Performance Expellant Medium N2 Based CO2 Based | - | - | - |
| N2 Based | - | - | - |
| Helium Based | - | - | - |
| Air Based | - | - | - |
| Argon Based Suitable for Class -A fire ratings as per EN 3-7 43A * Class -B Fire Rating for (Powder Based | - | - | - |
| Foam Based CO2 based Fire Extinguisher 233B * Fire Rating for Class -F NA * Operating Temperature ( -30° C≤ N >=60° C ) -30° C to + 60° C * Service Pressure 12 * Burst Pressure 55 * Minimum Discharge Time (seconds) required as per EN Standard 15 * Actual Discharge Time in seconds 20 * Certification Shelf Life (Life Cycle) of the Fire Extinguisher 20 year * Marine Equipment Directive(MED) Approved false * CE Certification from EU Notified Body Yes * CE Identification Number of the Notified Body (Must Declare) 0029 * Availability of Test Report from Central Govt./NABL/ILAC acredited lab to prove confirmity to specification Yes * Test Report No - * Test Report Date - * Name of the Lab - * Address of the Lab - * * Bold specifications are the golden parameters. 3/5 Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Chennaiah M 560075 | - | - | - |
| Aeronautical Development Establishment Defence R and D Organisation | - | - | - |
| Ministry of Defence | - | - | - |
| Government of India | - | - | - |
| Suranjandas Road New Thippasandra 34 30 | - | - | - |
Exempted
16 Oct 2018
4 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_693547.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .