Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC SEWA NAGAR COLONY NEAR JOGIO KI DHARAMSHALA BHIWANI 127021 | BHIWANI | BHIWANI | HARYANA | 127021 | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.7 L+₹3.2 L (23.9%)Rejected-Finance 1350 B SHYAM LAL BAGH NEAR NAND CINEMA HISAR 125001 | HISAR | HARYANA | 125001 | L2 | Rejected-Finance L2 |
Tender Value
₹13.9 L
EMD Value
₹27,860
Closing Date
13 Oct 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Elect. Division PWD B and R Br
Executive Engineer Elect. Division PWD B and R Br., Hisar
CONSTRUCTION OF NEW ADDITONAL PWD REST HOUSE AT HANSI IN DISTT. HISAR (PDG. E.I INTERNAL ONLY).
2021_HRY_190147_1
D/Elect-GGN/Elect-HSR/100241
Open Tender
Electrical Works
Works
120 days
Hisar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹27,860
4 Jan 2022
29 Sept 2021
14 Oct 2021
29 Sept 2021
13 Oct 2021
29 Sept 2021
60 days
Amount
Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. HSR 23.1.6. 23.1.6.6) 2 run of Size 1.50 Sqmm(1/1.40mm)
23.1.6.8) 2 run of Size 4 Sqmm(1/2.24mm)
23.1.6.9) 3 run of Size 1.50 Sqmm(1/1.40mm)
23.1.6.10) 3 run of Size 2.50 Sqmm(1.1.80mm)
COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) HSR 23.1. 23.1.1) Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. 23.1.1.3) Group C
23.1.2) Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. switch in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. 23.1.2.3) Group C
23.1.4) Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch required MS Box etc complete as required. 23.1.4.3) Group C
23.1.5) Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch required MS Box etc complete as required. 23.1.5.3) Group C
PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL HSR 23.7. 23.7.6) Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in wal Vceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. 23.7.6.1) PVC pipe of 20 mm dia.
23.7.6.2) PVC pipe of 25 mm dia.
23.7.6.3) PVC pipe of 32 mm dia.
FITTING AND ACCESSORIES HSR 23.8. 23.8.1) Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. 23.8.1.6) Call bell 220/23 0 volts musical type
23.8.1.12) Bakelite angle/straight button holder large size.
23.8.1.13) Socket size rotary step type Electronic regulator for A.C. ceiling fan.
23.8.3) Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite sheet as below. 23.8.3.1) 75 mm x 75 mm x 60 mm deep M.S. box
23.8.4) Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job.
23.8.10) Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 23.8.10.1) 1 & 2 Modules including combined plate for Telephone and data
23.8.10.6)12 Modules
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. HSR 23.8.11. 23.8.11.1) 5 amp 1 way switch
23.8.11.3) 15 amp 1 way switch
23.8.11.4) 5 amp Socket
23.8.11.5) 15 amp 6 pin Socket
23.811.7) step type Fan Regulator 2 modules 300 watt
23.8.11.8) Telephone Socket outlet modular type
23.8.11.9) TV Socket outlet modular type
23.8.11.10) Blanking plate
23.8.11.11) RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type
Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work. HSR 23.9
Making suitable hole in the wall suitable for exhaust fan up to 450 mm sweep including finishing the same and fixing of Stainless steel wire mesh 2 mm thick having about 50 meshes per inch at exhaust side complete as required HSR 23.11
Providing and fixing outdoor duty Ply of 12 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required HSR 23.12
Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required HSR 23.20
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. HSR 23.2223.22.1) Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 23.22.1.3) TRIPLE POLE MCCB 16 to 100 Amp, 25 KA
23.22.1.5) TRIPLE POLE MCCB 200 to 250 Amp, 25 KA
23.22.1.11) 4 pole MCCB 200 to 250 amp, 25 KA
23.22.1.12) 4 pole MCCB 300 to 400 amp , 50 KA
Supply and erection of sheet steel enclosures 1 pole/2 pole/4 pole on walVon existing pedestal complete as required. HSR 23.22.323.22.3.2) S.P.N. or DP enclosure suitable for DP MCB
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work.HSR 23.22.423.22.4.5) TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing)
23.22.4.7) TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing)
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- HSR 23.22.523.22.5.1) 6 amp. to 32 amp Single Pole
23.22.5.6) 40 amp to 63 amp. MCB's TRIPLE POLE
MISCELLANEOUS HSR 23.2323.23.1) Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):- 23.23.1.3) Size 25 mm dia
MS STAND, BUS BAR CHAMBER AND PANELS HSR 23.2423.24.1) Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide.
23.24.4.4) Load Bank 8 way 400 amp.
EARTHING AND LIGHTENING ARRESTOR HSR 24.124.1.1) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
24.1.2) Extra for using salt and char coal/coke for pipe earth electrode as required.
24.1.3) Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
24.1.4) Earthing with tinned copper earth plate 6D0mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
24.1.5) Extra for charcoal or coke and salt for G. I. plate or copper plate earth electrode.
24.1.7) Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
24.1.8) Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
24.1.9) Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.
24.1.10) Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
24.1.14) Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. staples of same size.
Supply and erection of suitable compression type brass cable glands for underground Cable :- HSR 24.2.724.2.7.2) 10 sqmm to 16 sqmm Cable 2 to 4 Core
24.2.7.3) 25 sqmm to 50 sqmm Cable 2 to 4 Core
24.2.7.4) 70 sqmm to 95 sqmm Cable 3 to 3½ Core
24.2.7.5) 120 sqmm to 185 sqmm Cable 3 to 32 Core
S/E mark double walled corrugated (DWC) HOPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HOPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. HSR 24.5.2) 24.5.2.5) DWC/HDPE pipe 120/105 mm outer dial inner dia
Non Schedule Items:- Supply and erection of Double door sheet, steel superline/ Powerline/ Loadline TPN Vertical distribution boards suitable for TP/ FP veritcal MCCBs 25 KA MCCB upto 125 amp as incomer (but without cost of MCCBs) fitted with busbars, Neutral links,& Blanking plates complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (C&S/ Indoasian/Siemens). 8 Way Vertical
Non Schedule Items:- Supply of Under Ground LT Power Cables of Aluminium Conductor complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Make:- Havell's/ Grandlay/ RR Kabel. 50 Sqmm 3.5 Core Ard. Cable
70 Sqmm 3.5 Core Ard. Cable
95 Sqmm 3.5 Core Ard. Cable
120 Sqmm 3.5 Core Ard. Cable
16 Sqmm 4 Core Ard. Cable
25 Sqmm 4 Core Ard. Cable
Non Schedule Items:- S/E of Modular Box for computer made of plastic surface box size 12 Module with 245mm x 172mm modular plate with support frame 12 module plateof white colour ISI Mark fixed on wall/wooden surface with cost of 1No. 16 A 3 Pin socketof ISI mark and 16 A 1way switch and 3 No. 6 A 3 Pin universal socket with 6 Amp. 1 way switch of ISI mark including Fixing the modular box in wall/wooden with including the all petty material & labour for errection, complete in all respect of upto the entire satisfaction of the Engineer-in-Charge of the work.
pawan Kumar
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .