Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC | L1 | Accepted-AOC L1 ACCEPTED | |
| 2 | L2₹38.1 L+₹76,165.75 (2.04%)Rejected-Finance NO 3 1ST FLOOR PLOT NO 9 LAKSHMIPURAM EXTN 2ND STREET WEST TAMBARAM | CHENNAI | CHENGALPATTU | TAMIL NADU | 600045 | L2 | Rejected-Finance L2 REJECTED |
Tender Value
₹45 L
EMD Value
₹45,000
Closing Date
20 Sept 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The COmmissioner,Tambaram City Municipal Corporati
No.01,Kalaivani Street ,Sembakkam,Chennai-63
Construction of Pumping Station at Chitlapakkam Lake Near Chidhambaranar Street Ward No.44 Zone-3.
2023_MAWS_369794_4
558/2023/E1
Open Tender
Civil Works
Works
90 days
Tambaram City Municipal Corporation Zone -3
Construction of Pumping Station at Chitlapakkam Lake Near Chidhambaranar Street Ward No.44 Zone-3.
2 documents required · 2 mandatory
₹0
₹45,000
18 Mar 2024
14 Sept 2023
20 Sept 2023
14 Sept 2023
20 Sept 2023
14 Sept 2023
Amount
Earth work excavating and depositing on bank with initial lead of 10m & initial lift of 2m in Sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soil including excavated earth (SS20B)
Open well excavation complying with relevant clauses of T.N.D.S.S well sinking and with lead up to 10m in Medium rock and dence medium rock requring blasting, first depth of 2 meters
2.00m to 4.00m below ground level
4.00m to 6.00m below ground level
6.00m to 8.00m below ground level
8.00m to 10.00m below ground level
Supplying and filling in foundation and basement with Crusher Stone dust in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
Plain Cement Concrete 1:4:8 (one cement, four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing,and labour charges etc., complete as per standard specification
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
Providing and laying in position Standardised Concrete Mix M-25 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 350Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards.
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors as per standard specification.
Dewatering using 5.00 HP diesel engine pumpset including Hire charges, cost of diesel, engine oil, Pump operator, labour charges, conveyance of pump set and fuel to site and back loading, unloading and any other incidential charges etc complete
Supply and delivery of 30HP Open well Submersible pump set as per 14220 / 2002 With out panel Board 2000 lpm x100m including cost and conveyance of materials to work site etc complete.
Supply and delivery of 25 HP Three phase panel board star -delta with two level guard and auto start including cost and conveyance of materials to work site etc complete.
Supply and delivery of jointing of XLPE insulated and sheathed 4 sq.mm 3 core flat type copper cable conforming to IS 694/1990 etc complete as per standard Specification
Supply and delivery of following PVC,HDPE,GI pipes and specials etc completed
125mm dia GI pipe
125mm dia GI Elbow
125mm dia Gi coupling
125mm dia Hex Nipple
125mm dia SS Hose collar
125mm dia GM NRV
125mm dia PVC FTA
Nylon Rope
125mm dia GI Flange Set
160mm dia PVC Pipe 10KCS
160mm dia PVC bend
160mm dia PVC couplers
160mm dia PVC Tee
Supply and delivery of Gi stay wire etc completed as per standard specification
Supply and clarnping of except 3-1/2 x 25 sq.mm. PVC LTUG armoured cable including all the cost and conveyance of materials as per SD 222
Wiring with 2x1.5 Sq.mm(22/0.3)PVC insulated unsheathed Sc Cu .conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A F.t switch inflush with wall covered with hylem sheet of 3mm thick with painting of suitable colour for open PVC light point/fan point SD18
Supply and fixng of TNEB Meter Board suitable for 3 Phases 200A service connection made up of suitable angle iron frame work of size 3 feet x 2 feet using angle iron of size 1 1/2" x 1 1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 3 feet x 2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos 200A fuse units (500V) 1 No. Neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuseunits by 19/16 PVC insulated copper wire with earth connection complete SD 131
Earthing as per P.W.D standard with an earth electrode of 2mtr class "B" GI pipe of dia not less than 32mm complete with necessary masonry work as SD 234
Labour Charges for the erection of submersible pumpset in borewell including fixing and jointing submersible cable with proper clamps upto the starter to the required depth and also fixing of riser pipes to required depth values erection clamps,pressure gauges up to the exterior wall of pump room and erextion of panel board consisting of TPICN switches starter,voltmeter,ammeter,three pilot 9indicating) lamps capacitor single phasing preventor ,water level guard and laying and jointing the cables and twin earthing and jointing the cables and twin earthing as per as per I.E. rules etc. complete and testing the pump set and trail run for 10 days
Cutting the BT Road surface including cost of all labour charges etc completed.(TWAD Board Rates 2022-23)
Earth work excavation and depositing on bank initial lead of 1.00mand lift of 2m in narrow trenches for laying of pipes for water supply in the following type of soils of sand,silt or othe loose soil ,wey sand or silt not under water light black cotton soil ,sandy loam and ordinary soil etc complete as per standard specification.
Supplying and filling the foundation and basement with stone dust in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
Lowering 160mm dia PVC pipe 6KCS and specials to trench and laying to proper grade and alignment, jointing with PVC couplurs with cement paste including cost and convence of labour charges ect., complete
Refilling with excavated earth other than sand with an initial head load of 10 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
Supplying, Fabricating, Erecting structural steel work for roofing welding or bolted type using MS Channels, angles, plates and round bars etc conforming to IS specification including primer coating and enamel painting as per Design given by the departmental officers etc, complete as per standard specification
Supplying, Fabricating, Erecting of Weld Mesh 7.5x2.5cm 10 Gauge including cost and conveyance of all materials and labour charges etc complete
Construction of brick work pedestal for Kiosk box using country bricks in cm 1:5 mix,size of 0.75mx0.45x1.40m height ,including necessary earth work filling sand, PCC 1:4:8 using 40mm HBG metal,plastering with cement mortar 1;5 mix to 12mm thick and painting two coats over one coat of white washing fixing Kiosk boxover the pedestal etc completed as per standard specification
Supply and delivery of MS Kiosk of size 0.75mx0.45mx0.75m made up of MS angle of size 50mmx50mmx4mm alround covered with 16gauge MS sheet and Kiosk door made up of MS plates of size 25mmx3mm including cutting,welding,grinding .locking arrangements and labour charges etc
Vibrant Foundation
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_440979.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .