Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹9.4 L+₹71,343 (8.17%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Due to not enlisted in appropriate category b(ii) |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
2 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
REPAIR/REPLACEMENT OF HT OH LINES, HT UG CABLES, HT POLES AND OTHER CONNECTED ITEMS AT MRS CHINTA, NASKA, DUGGA, CHINCHORA, JAIGHATI, BN-II AND BN-III UNDER GE (I) 873 EWS
2023_MES_610637_1
NIT-44of 2023-24
Open Tender
Civil Works
Item Rate
180 days
Bhaderwah
As per NIT
7 documents required · 7 mandatory
₹500
GE(I) 873 EWS
₹20,000
Yes
6 Nov 2023
25 Jul 2023
4 Sept 2023
25 Jul 2023
2 Sept 2023
14 Aug 2023
Amount
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and exceeding 1.5metre depth but not exceeding 3.0metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Cutting of existing road / hard standing for laying of GI protection pipe for cables, depth of trench not exceeding 0.75mtr, width of trench not exceeding 1.0mtr and making good by returning filling in (by well ramming and watering of soil in layers not exceeding 25cms), provision of 150mm thick sub base, 150mm thick WBM and therafter 150mm thick PCC 1:2:4 type B-1 (using 20mm graded agggregate) including removal of surplus spoil to a distance not exceeding 50mtrs complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supplying and laying reinforced precast concrete cable cover, class HVP, type 1 with peak, size size 300 mm x 180mm x 40mm laid in trenches flat complete all as specified and directed.
Cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Steel Tubular swaged poles type 410 SP-55 (11.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete including taking down old unserviceable Pole all as specified and as directed.
Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer including dismantling / taking down old unserviceable structural steel all as specified and directed.
Polymer Pin type porcelain in replacement, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100mm height, 65mm dia for 1100 volt complete including taking down old unserviceable insulator complete all as specified and directed.
Shackle type insulator, porcelain, in replacement, vitreous, white, brown or green including one galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nut, 75mm height, 90mm dia for 1100 volts grade complete all as specified and directed.
Polymer Disc type insulator, porcelain, vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised 145 mm height 255 mm dia for 11000 Volts grade including taking up of old unserviceable insulator complete all as specified and directed.
Aluminium conductor steel reinforced (ACSR) including binding to insulator with suitable size of binding wire and size of conductor Weasel (6/1 x 2.59 mm), Squirrel (6/1 x 2.11mm) or Ferret (6/1 x 3.00 mm) all as specified and directed.
Cutting and trimming of trees and branches to clear the over head line in the arc of HT/LT over head line feeders and removal of the trimmed branches of trees complete all as specified and directed. Notes : 1. Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor, to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever. 2. The cutting / trimming of tree branches shall be done to at least 2.00 metre radius of OH line. 3. The unit of measurement is 'SPAN' i.e. distance covered between two poles.
Stay assembly complete with accessories as shown in Electrical Plate No.1 of SSR 2009 Part-I using stay rod of 16 mm dia, stay bow 14 mm dia, 400 mm long, MS Plate of size 300 x 300 mm x 6mm thick, stay GI wire 7/4mm dia (loop type insulator stay clamp, excavation and concrete shall be measured and paid separately) complete all as specified and directed.
Loop type insulator, vitreous white, brown or green large size with overall dimension 65 x 90mm with clearance of hole 16mm complete all as specified and directed.
Galvanised Guard wire / Cradles / Stay wires 7/3.15mm complete as required at site all as specified and directed.
Painting of steel tubular pole 11mtr any type with cross arms with one coat of aluminium paint after preparation of surfaces of pole / cross arms by scrapping of old paint, cleaning of all rusted surface and painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface of pole and cross arms structure over one coat of primer and marking of MES No complete all as specified and directed.
Cradles, hexagonal/rectangular, fabricated with galvanized steel wire 3.15mm or 4mm dia including taking down old, complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts earthed, grade cross sectional area 95 Sqmm 3 core laid in trences complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts earthed, grade cross sectional area 120 Sqmm 3 core laid in trences complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts earthed, grade cross sectional area 150 Sqmm 3 core laid in trences complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts earthed, grade cross sectional area 185 Sqmm 3 core laid in trences complete all as specified and directed.
Cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
Cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120-185 Sqmm complete all as specified and directed.
Cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240-300 Sqmm complete all as specified and directed.
Cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
Cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120-185 Sqmm complete all as specified and directed.
Cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240-300 Sqmm complete all as specified and directed.
Straight through cable jointing kit for 11 KV (earthed) grade cable for heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
Straight through cable jointing kit for 11 KV (earthed) grade cable for heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120-150 Sqmm complete all as specified and directed.
Straight through cable jointing kit for 11 KV (earthed) grade cable for heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm complete all as specified and directed.
Switch Air break, gang operated (GOD) with 09 No insulators in replacement, outdoor type, Three Pole mechanically operated, suitable for vertical installation, Single break, provided with locking arrangements consisting of MS channel, HT Post type insulator copper alloy, high Pressure, Assembly operating rod 25 mm dia GI pipe medium grade for operating from 1.2 metre above Ground Level with locking arrangement complete confirming to IS-1318 of 1972 rated voltage 11 KV and for current rating 200 Amps complete all as specified and directed.
Switch Air break, gang operated (GOD) with 09 Nos insulators in replacement, outdoor type, Three Pole mechanically operated, suitable for vertical installation, Single break, provided with locking arrangements consisting of MS channel, HT Post type insulator copper alloy, high Pressure, Assembly operating rod 25 mm dia GI pipe medium grade for operating from 1.2 metre above Ground Level with locking arrangement complete confirming to IS-1318 of 1972 rated voltage 11 KV and for current rating 400 Amps complete all as specified and directed.
MCCB 160 Amps, breaking capacity 16 KA, 3 Pole, 415V, fixed type including taking down old unserviceable MCCB complete all as specified and directed.
MCCB 160 Amps, breaking capacity 36 KA, 4 Pole, 415V, fixed type including taking down old unserviceable MCCB complete all as specified and directed.
MCCB 200 Amps, breaking capacity 36 KA, 4 Pole, 415V, fixed type including taking down old unserviceable MCCB complete all as specified and directed.
MCCB 250 Amps, breaking capacity 36 KA, 4 Pole, 415V, fixed type including taking down old unserviceable MCCB complete all as specified and directed.
MCCB 350 Amps, breaking capacity 36 KA, 4 Pole, 415V, fixed type including taking down old unserviceable MCCB complete all as specified and directed.
MCCB 400 Amps, breaking capacity 36 KA, 4 Pole, 415V, fixed type including taking down old unserviceable MCCB complete all as specified and directed.
Aluminium cable lugs (connectors) for fixing/tightening of electric cable 95 Sqmm alonwith nuts and bolts, complete all as specified and directed.
Aluminium cable lugs (connectors) for fixing/tightening of electric cable 120 Sqmm alonwith nuts and bolts, complete all as specified and directed.
Aluminium cable lugs (connectors) for fixing/tightening of electric cable 150 Sqmm alonwith nuts and bolts, complete all as specified and directed.
Aluminium cable lugs (connectors) for fixing/tightening of electric cable 185 Sqmm alonwith nuts and bolts, complete all as specified and directed.
Synthetic Insulation Mat in replacement, chequered type up to 11 KV rating as per ISI specification of size 2.0m x 1.0m x 2.5mm thick for votage upto 3.3kv electric purfose as per IS 15652-2006, (superseding IS 5424) complete all as directed.
M/S AKHILESHWAR ASSOCIATES
Bidder Name
M/S Builders Indias
M/S AKHILESHWAR ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .