Tender Value
₹161.4 Cr
EMD Value
₹3.2 Cr
Closing Date
9 Aug 2021, 5:00 pmClosed
CE SO and C
Shakti Bhawan, HVPNL, Panchkula
Reliable Communication and Data Acquisition System for 132 kV and above Network in Haryana
2021_HBC_158127_1
EPC/2/Reliable Comm.
Open Tender
Electrical Works
840 days
Panchkula
Please refer Tender Document
8 documents required · 8 mandatory
₹11,800
Yes
₹3.2 Cr
Yes
SLDC Panipat
21 Jun 2022
1 Feb 2021
19 Aug 2021
1 Feb 2021
9 Aug 2021
1 Feb 2021
1 Feb 2021 - 3 Mar 2021
18 Feb 2021
Amount
OPGW cable & Accessories
24 Fibre (DWSM) OPGW fibre optic cable
Installation Hardware set for above 24 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except Joint Box
Suspension Clamp Assembly for 24F OPGW
Tension assembly Dead End for 24F OPGW
Tension Fitting assembly for 24F OPGW including all accessories for joint box (splicing ) location
Tension Fitting assembly double tension pass through assembly for 24F OPGW
Tension fitting assembly on suspension tower for 24F OPGW including all accessories at joint box (splicing ) location
Vibration Damper for 24F OPGW
Down Lead Clamp Assembly for 24F OPGW
Joint Box (24 Fibre)
48 Fibre (DWSM) OPGW fibre optic cable
Installation Hardware set for above 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except Joint Box
Suspension Clamp Assembly for 48F OPGW
Tension assembly Dead End for 48F OPGW
Tension Fitting assembly for 48F OPGW including all accessories for joint box (splicing ) location
Tension Fitting assembly double tension pass through assembly for 48F OPGW
Tension fitting assembly on suspension tower for 48F OPGW including all accessories at joint box (splicing ) location
Vibration Damper for 48F OPGW
Down Lead Clamp Assembly for 48F OPGW
Joint Box (48 Fibre)
Supervision of stringing of 24 fibre OPGW during installation (50 kms) on under-construction transmission line
Splicing and installation of joint boxes
End to End testing of OPGW cable (installed)
FODP 48F: Indoor type, rack mounted with FCPC coupling and pigtails
FODP 96F: Indoor type, rack mounted with FCPC coupling and pigtails
Fibre Optic Approach Cable
24 Fibre (DWSM)
Installation Hardware set for above 24 Fibre, Fibre Optic Approach Cable
48 Fibre (DWSM)
Installation Hardware set for above 48 Fibre, Fibre Optic Approach Cable
AERIAL FO CABLE & ACCESSORIES
24F (DWSM) Aerial Fibre Optic Cable
Installation Hardware Set For Above 24 Aerial Fibre Optic Cabling Including All Cable Fittings & Accessories Except Joint Box
Joint box (24 fibres)
48F (DWSM) Aerial Fibre Optic Cable
Installation Hardware Set For Above 48 Aerial Fibre Optic Cabling Including All Cable Fittings & Accessories Except Joint Box
Joint box (48 fibres)
UGFO Cable & Accessories
Unarmored UGFO Cable (24 F DWSM)
GI Pipe 100mm (Nominal Bore) medium class (incl. access
Joint Box (24 Fibre)
RCC Hume pipe (NP3) 100mm dia (inside)
PLB HDPE pipe O.D 40mm
Survey & documentation
Excavation and Backfilling
Warning Tape
Unarmored UGFO Cable (48 F DWSM)
Joint Box (48 Fibre)
Installation of HDPE pipe by Trenchless digging
RCC Manholes (supply and installation)
for joint locations
for providing service loops at crossing
Brick walled manholes (supply and installation)
for joint locations
Installation of PLB HDPE pipe on wall in building premises including routing of OFC through it.
MANDATORY SPARES
OPGW cable & Accessories
24 Fibre (DWSM) OPGW fibre optic cable
Installation Hardware set for above 24 Fibre OPGW Fibre Optic cabling incl. all cable fittings & accessories except Joint Box
Suspension Clamp Assembly for 24F OPGW
Tension assembly Dead End for 24F OPGW
Tension Fitting assembly for 24F OPGW including all accessories for joint box (splicing ) location
Tension Fitting assembly double tension pass through assembly for 24F OPGW
Tension fitting assembly on suspension tower for 24F OPGW including all accessories at joint box (splicing ) location
Vibration Damper for 24F OPGW
Down Lead Clamp Assembly for 24F OPGW
Joint Box (24 Fibre)
48 Fibre (DWSM) OPGW fibre optic cable
Installation Hardware set for above 48 Fibre OPGW Fibre Optic cabling incl. all cable fittings & accessories except Joint Box
Suspension Clamp Assembly for 48F OPGW
Tension assembly Dead End for 48F OPGW
Tension Fitting assembly for 48F OPGW including all accessories for joint box (splicing ) location
Tension Fitting assembly double tension pass through assembly for 48F OPGW
Tension fitting assembly on suspension tower for 48F OPGW including all accessories at joint box (splicing ) location
Vibration Damper for 48F OPGW
Down Lead Clamp Assembly for 48F OPGW
Joint Box (48 Fibre)
Fibre Optic Approach Cable
24 Fibre (DWSM)
Installation Hardware set for above 24 Fibre, Fibre Optic Approach Cable
48 Fibre (DWSM)
Installation Hardware set for above 48 Fibre, Fibre Optic Approach Cable
AERIAL FO CABLE & ACCSSORIES
24F (DWSM) Aerial Fibre Optic Cable
Installation hardware set for above 24 aerial fibre optic cabling including all cable fittings & accessories except joint bax
Joint Box (24 Fibres)
Spares for UGFO Cables & Accessories
Unarmoured UGFO Cable (24 F DWSM)
GI Pipe 100mm (Nominal Bore) medium class (incl. access
Joint Box (24 Fibre)
RCC Hume pipe (NP3) 100mm dia (inside)
PLB HDPE pipe O.D 40mm
Deduct - Return of Existing Earth Wire on as is where is basis.***
Transmission Equipment (Total Scope)
SDH Equipment- (STM-16 MADM, upto 5 MSP protected directions)
Base Equipment (Common cards, Cross-connect/control cards, Optical base card, Power supply cards, power cabling, other hardware & accessories including sub-racks, patch cords, DDF etc. fully equipped excluding excluding optical cards and tributary cards).
Optical Cards
OLI to support minimum 150 km for STM-16
Tributary Cards
E1 Interface card (Min. 16 interfaces per card)
Ethernet interface 10/100 Mbps with Layer-2 switching (Min. 8 interfaces per card)
Gigabit Ethernet (Layer 2) interface (min. 2 nos.)
Termination Equipment
Drop & Insert Multiplexer
Base Equipment (Common cards, Power supply cards, power cabling, other hardware & accessories including sub-racks, etc. fully equipped excluding subscriber line interface cards
Subscriber Line Interface Cards
2 wire (sub/sub) voice channel cards (min 8 channels per card)
2 wire (sub/Exch) voice channel cards (min 8 channels per card)
4 wire (E&M) voice channel cards (min 8 channels per card)
Asynchronous Sub Channels data cards(V.24A/,28) , minimum 4 channels per card
Synchronous data cards(N*64 kbps) minimum 4 channels per card
Digital Access Cross Connect Switch (DACS)
16 × 16 ports switching matrix, fully equipment for minimum 16 E-1 ports
Equipment Cabinet
For SDH Equipment, Drop/Insert MUX Equipments
NMS - Main Control Centre
Craft Terminal
Hardware
Software
Network Manager & Element Manager System
Hardware
Software
Printer (Laser Jet)
NMS - Back up Control Centre
Craft Terminal
Hardware
Software
Network Manager & Element Manager System
Hardware
Software
Printer (Laser Jet)
Remote Workstation
Hardware
Software
Main Distribution Frame {200 pairs)
Synchronization Equipment
GPS clock including ail hardware and accessories
Test Equipment for SDH & MUX
SDH Analyser with Jitter and Wander Options
Handheld 2Mbps BER Tester
Ethernet Tester (with dual port, 10/100 ports Mbps Ethernet option, layer-1 & layer-2 functionality)
Mandatory Spares
Transmission Equipment (Total Scope)
SDH Equipment- (STM-16 MADM, upto 5 MSP protected directions)
Base Equipment (Common cards, Cross-connect/control cards, Optical base card, Power supply cards, power cabling, other hardware & accessories including sub-racks, patch cords, DDF etc. fully equipped excluding optical cards and tributary cards)
Optical Cards
OLI to support minimum 150 km
Tributary Cards
E1 Interface card (Min. 16 interfaces per card)
Ethernet interface 10/100 Mbps with Layer-2 switching (Min. 8 interfaces per card)
Gigabit Ethernet (Layer 2) interface (min. 2 nos.)
Termination Equipment
Drop & Insert Multiplexer
Common cards, Power supply cards, power cabling, other hardware & accessories including sub-racks, etc. fully equipped excluding subscriber line interface cards
Subscriber Line Interface Cards
2 wire (sub/sub) voice channel cards (min 8 channels per card)
2 wire (sub/Exch) voice channel cards (min 8 channels per card)
4 wire (E&M) voice channel cards (min 8 channels per card)
Asynchronous Sub Channels data cards(V.24A/,28) , minimum 4 channels per card
Synchronous data cards(N*64 kbps) minimum 4 channels per card
Digital Access Cross Connect Switch (DACS)
16 × 16 ports switching matrix, fully equipment for minimum 16 E-1 ports
Pre connectorized optical fibre patchcords (10 mtrs) - pack of 6 patch cords
Main Equipments
48V DC Power Supply (DCPS) system based on SMPS (for 15A rating)
Battery bank for above DCPS (200 AH)
48V DC Power Supply (DCPS) system based on SMPS (for 25A rating)
Battery bank for above DCPS (300 AH)
48V DC Power Supply (DCPS) system based on SMPS (for 35A rating)
Battery bank for above DCPS (400 AH)
Mandatory Spares for DCPS
MCCB/MCB-2P/contactor/ timer/ Relay of each type & Rating (as applicable)
Single Pole MCBs (for Outgoing DC Feeders)
Electronic Printed Circuit Board / Card of each type (all cards/module including SMPS Module, DC Power Supply Controller, various interface cards etc.)
VOIP System*
(i). Base Equipment (including Programming/Configuration Console, Common cards, Control Cards, power supply card, cabling, NMS, Other hardware & Accessories) excluding following (ii) to (Iii) Interface Cards With Redundant PS & CPU
(ii). VOIP interface/card (Active / Active) supporting minimum 1500 VoIP users (IPextensions) expandable upto 5000 users
(iii). E1 interfaces
VoIP Gateways for Wide Band Locations (4 ports)
VoIP Gateways for Wide Band Locations (8 ports)
VoIP Gateways for Corporate Office (24 ports)
PoE Switches minimum 4 port
Telephone Instruments& Accessories
Analog Phone&Accessories
Analog Phone&with Caller Id
Two pair cable
Faceplate
Gang Box
IP phone&Accessories
IP phone
CAT-6 Cable
CAT-6 faceplate
CAT 6 I/O
Gang Box
Furniture (Table) for placing IP phones & Configuration Consoles at SLDC
Mandatory Spares
Common Cards/Units (CPU, Switching Matrix, Power Supply Unit, Ringer etc)
VoIP Interface Card
E1 interface Card
IP Phone
RTU & LDMS
RTU base equipment comprising panels, racks, sub-racks, Power Supply modules, Communication Modules, interfacing equipment, required converters & all other required items/accessories including complete wiring for all modules for locations mentioned in Appendix-A and Expansion Requirements of spec
CPU and Communication Cards as per Appendix-A and Expansion Requirements of spec
Analog Input Card for all modules for locations mentioned in Appendix-A and Expansion Requirements of spec
Digital Input Card for all modules for locations mentioned in Appendix-A and Expansion Requirements of spec
Digital Output Card for all modules for locations mentioned in Appendix-A and Expansion Requirements of spec
Multi Function Transducer (MFT)
Weather Sensors
OLTC Transducer
Contact Multiplying Relay (CMR)
Heavy Duty Relay (HDR)
Time Synchronisation equipment without display
Communication between Co-loacted RTU equipments
Communication cards including necessary connectors
Fiber Optic cable including Conduits
LDMS System
LDMS Software
LDMS Hardware
Furniture (1 Table and 1 chair)
Inverter
Test Equipment for RTU
Master Station cum RTU simulator & Protocol Analyser Software tool
Database Configuration Tool for the supplied RTUs
Laptop PC for above software tools alongwith interfacing hardware
Spare Equipments
RTU cards of each type including CPU and time synchronisation equipment
Multi Function Transducer (MFT)
Weather Sensors
OLTC Transducer
Heavy Duty Relay (HDR)
LDMS system (complete hardware)
TRAINING CHARGES (Schedule – B)
Communication Equipment and Auxiliary Power Supply DCPS
SDH and PDH
DCPS & associated batteries
VOIP Equipment
OPGW Cable & Accessories
RTUs& LDMS
ANNUAL MAINTENANCE CHARGES(Schedule – C)
Maintenance Charges for SDH, PDH & NMS systemincluding DCPS system and VOIP Equipment for 1 year during warranty period
SDH & PDH
NMS (Hardware & Software)
DCPS & associated batteries
VOIP Equipment
Cyber audit from CERT-IN 3rd party empaneledvendor for 1 year during warranty period (Half Yearly)
Maintenance Charges for SDH, PDH & NMS system including DCPS system and VOIP Equipment for 6 years after warranty period
SDH & PDH
NMS (Hardware & Software)
DCPS & associated batteries
VOIP Equipment
Cyber audit from CERT-IN 3rd party empaneledvendor for 6 years after warranty period (Half yearly)
Maintenance Charges for Fibre Optic Cabling for 1 year during warranty period (per Fibre Optic Cable)
Maintenance Charges for Fibre Optic Cabling for 6 years after warranty period (per Fibre Optic Cable)
Maintenance Charges for RTUs& LDMS for 1 year during warranty period
Maintenance Charges for RTUs& LDMS for 6 years after warranty period
Database modification including supply of MFTs, Transducers, CMRs, HDRs, & necessary wiring & cabling for addition of new bay during Maintenance Period
Rate of Fitter / Labour
Rate of Fitter / Labour per day per labour
OPGW Rectification / Diversion work(0 to 250 km from base station of deployed team)
Cost for Mobilisation and Demobilisation of Man and Material
Dismantling of OPGW / Earthwire
Laying of OPGW 24/48 Fibre
Splicing of OPGW 24/48 Fibre
Note: 1. # - One Set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of Aerial/Approach fibre optic cable. 2. The existing earthwire alongwith its hardware & fittings shall be dismantled and taken away by the contractor on installation of OPGW. Also, after the installation of OPGW, the empty drums of OPGW would be taken back by the Contractor. This factor may be taken into consideration while quoting the price 3. *** The cost for Return of Existing Earth Wire shall be a minus value and thus negated from the bid price. 4. In case of Optical cards, the final quantities shall be decided at the time of detailed engineering / link budgeting 5. *Active / Active Redundancy of CPU/Call server, Storage, Control Card, Power Supply Card shall be provided in VOIP Equipment. Distributed power supply is also acceptable 6. ** VOIP Interface/Card shall have redundancy in hot stand-by mode. 7. (All the unit/cards supplied under Sr. no. 26.01 in spare item should be identical to those supplies as main quantity)
Note: 8. ^^- Quantity to be filled in Appendix-E of Technical Specifications of RTU, declaring the no. of cards in each offered lot. No. of cards should be in line with the no. of I/O channels per card meeting with the I/O requirement of all RTU Substation sites as per Technical Specifications requirement (I/O requirement break up given at Appendix-A of RTU Technical Specs). 9. No. of bays under item no. 44 above are indicative and which may vary upto any extent depending upon the power growth in the region. 10. The Maintenance Charges for Fibre Optic Cabling per annum shall be atleast 0.5 % of the supply cost of the OPGW & associated hardware accessories (excluding spares cost) 11. The Maintenance Charges for SDH, PDH & NMS system including DCPS system, and VOIP Equipment per annum shall be atleast 1.5 % of the supply cost of the respective Equipment (excluding spares cost) 12. The Maintenance Charges for RTU and LDMS per annum shall be atleast 1.5 % of the supply cost of RTU and LDMS (excluding spares cost).
LS CABLE INDIA PVT LTD
APAR INDUSTRIES LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid