Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹25.6 LAccepted-AOC | L-1 | Accepted-AOC Being the lowest bidder | |
| 2 | L-2₹26.1 L+₹51,995 (2.03%)Rejected-AOC | L-2 | Rejected-AOC Not being the lowest bidder | |
| 3 | L-3₹26.7 L+₹1.1 L (4.25%)Rejected-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L-3 | Rejected-AOC Not being the lowest bidder | |
| 4 | L-4₹26.9 L+₹1.3 L (4.99%)Rejected-AOC B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L-4 | Rejected-AOC Not being the lowest bidder | |
| 5 | L-5₹27.7 L+₹2.1 L (8.25%)Rejected-AOC B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L-5 | Rejected-AOC Not being the lowest bidder |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
1 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SANGRAM SINGH
GE Kaluchak Pin-900673 C/o 56 APO
PROVN OF 84 GEYSERS CONNECTED WORKS EXHAUST FANS FOR JCOs ORs MD ACCN AND WORK SERVICES FOR PROVN OF LT PANEL AND LT CABLING AT RATNUCHAK MIL STN UNDER GE KALUCHAK
2020_MES_365093_1
GE/KC/NIT-34/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹73,000
Yes
22 Sept 2020
29 Jul 2020
3 Sept 2020
29 Jul 2020
1 Sept 2020
14 Aug 2020
29 Jul 2020 - 13 Aug 2020
60 days
Amount
Sub main wiring using uniform coding of wiring with two runs of 6.0 Sqmm single core FRLS PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn into and including PVC concealed conduit 'ISI marked' of 25mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required with all fittings and fixing accessories & one run of 4.00 Sqmm FRLS PVC insulated solid copper conductor for earth continuity wire in green colour, complete all as specified & directed. Note:- Two runs of copper conductor 6.0 sqmm and one run of 4.00 Sqmm copper earth wire including PVC conduit of 25mm dia will be measured and paid as one unit only.
Supply, installation and testing of water heater storage type (Geyser) single phase, 230V, 50Hz, 5 star energy saving, high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type, 25 Litre capacity, 2000 Watt rated power, incoloy 800 glass coated heating element, tank coating of ferro glass dry powder tank made of ultra thick super cold rolled steel plates, rated pressure 0.8MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting up fixed to walls by drilling of holes, grouting of bolts of suitable size with nuts etc and making good disturbed surface, complete all as specified & directed. Make. HAVELLS Model No: Monza DX, Cat Part No. GHWAMGTWH025 or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Sheet metal enclosures single pole and neutral enclosure with a two pin and earth plug with socket complete with one double pole MCB 20 Amps, C series, 240 volts, complete all as specified & directed.
Cutting & screwing of existing water supply line of 15mm bore for alterations or additions (or lengthening screw on pipe to form connector) including fittings, testing after completion, complete all as specified & directed.
Galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors , complete all as specified and directed.
Stop/angle valves, cast copper alloy, 15mm bore, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specifed & directed.
Bib tap, 15mm bore, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, complete all as specified & directed.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one exhaust fan point controlled by one way switch using proper colour coding, complete all as specified & directed.
Switch piano flush type 5 Amps 240 volt, single pole one way, complete all as specified & directed.
Ceiling rose surface type, bakelite 65mmx50mm, 3 terminals, 240 Volt, complete all as specified & directed.
Metallic exhaust fan, 300mm (12") sweep, single phase, 230 volts, 50 Hz AC, 1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings, complete with louvers and shutters, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site, complete all as specified & directed. Make. Havells, Cat Part No.Turbo Force SP or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts, the panel board shall be made of 3.15 thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side, base frame of the panel shall be made of ISMC channel of size 50x50x6mm thick, copper earth busbar of 25x3mm shall be provided for the entire length of panel, provision shall be made for connection from earth busbar to the main earthing bar coming from the earth pit on both side of the panel, the danger notice plate both in Hindi and English showing skull and bones as per IS:2551-1982 and IS 5-1978 shall be fixed on both side back and front, the panel should have four legs made of 50x50x6mm thick MS angle iron,each 90cm long (45cm below ground embedded in PCC 1:2:4 type B1 using 20mm aggregate and remaining height above ground),
the size of PCC foundation should be not less than (0.30x0.30x0.45metre) for each leg, the panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears, busbar shall be made of high quality high conductivity, high strength copper and as per relevant IS code, bus bar shall of three phases and neutral system with separate neutral and earth bar, busbar and interconnection between busbar and various components shall be of high conductivity, high drawn electrolytic copper, busbar shall be rectangular in cross section design to withstand full load current for phase busbar and half of rated current for neutral busbar and shall be extensible on either side, busbar and interconnection shall be insulated with heat shrinkable PVC sleeves and colour coded in red,yellow, blue & black, busbar shall be supported on unbreakable, non hygroscopic DMC insulated support,
busbar shall be capable to withstand electromagnetic stresses in the event of short circuit capacity of 50KA RMS symmetrical for one second and a peak short circuit withstand of 105KA minimum, the busbar shall be housed in a separate compartment, busbar shall be isolated with 3mm thick bakelite sheet to avoid any accidental contact, the clearance between busbar shall be maintained as per relevant IS codes, the panel shall be completely dust and vermin proof and degree of protection not less than IP-54, the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's including extended aluminium strip of rating of Incomer 350 Amps and outgoing as per rating of MCCB’s including aluminium lugs to connect the cable dismantled before etc., and comprising of the following:-
(a) MCCB 350 amps, 4 pole with breaking capacity 36KA (Adjustable thermal & magnetic release) - 01 No (Incomer) (b) MCCB 125 amps, 4 pole with breaking capacity 25 KA (Adjustable thermal & magnetic release) - 4 Nos (outgoing) (c) MCCB 63 amps, 4 pole with breaking capacity 25 KA (Adjustable thermal & magnetic release) - 1 No (outgoing) (d) Digital LED voltmeter, 3 phase, class 0.5 - 01 No. Make. Schneider Model No.DM3210 (e) Digital LED ammeter, 3 phase, class 0.5 - 01 No. Make. Schneider Model No.DM3110 (f) 3 Nos Phase indication LED lamps RYB - 1 Set (g) CT's 400/5 - 01 Set Make.L&T/ AE/ Shanti/ Legrand/ Lappa/ Pragati Location - Main LT Panel near transformer at Tarapore Vihar
Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts, the panel board shall be made of 3.15 thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side, base frame of the panel shall be made of ISMC channel of size 50x50x6mm thick, copper earth busbar of 25x3mm shall be provided for the entire length of panel, provision shall be made for connection from earth busbar to the main earthing bar coming from the earth pit on both side of the panel, the danger notice plate both in Hindi and English showing skull and bones as per IS:2551-1982 and IS 5-1978 shall be fixed on both side back and front, the panel should have four legs made of 50x50x6mm thick MS angle iron,each 90cm long (45cm below ground embedded in PCC 1:2:4 type B1 using 20mm aggregate and remaining height above ground),
the size of PCC foundation should be not less than (0.30x0.30x0.45metre) for each leg, the panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears, busbar shall be made of high quality high conductivity, high strength copper and as per relevant IS code, bus bar shall of three phases and neutral system with separate neutral and earth bar, busbar and interconnection between busbar and various components shall be of high conductivity, high drawn electrolytic copper, busbar shall be rectangular in cross section design to withstand full load current for phase busbar and half of rated current for neutral busbar and shall be extensible on either side, busbar and interconnection shall be insulated with heat shrinkable PVC sleeves and colour coded in red,yellow, blue & black, busbar shall be supported on unbreakable, non hygroscopic DMC insulated support,
busbar shall be capable to withstand electromagnetic stresses in the event of short circuit capacity of 50KA RMS symmetrical for one second and a peak short circuit withstand of 105KA minimum, the busbar shall be housed in a separate compartment, busbar shall be isolated with 3mm thick bakelite sheet to avoid any accidental contact, the clearance between busbar shall be maintained as per relevant IS codes, the panel shall be completely dust and vermin proof and degree of protection not less than IP-54, the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's including extended aluminium strip of rating of Incomer 200 Amps and outgoing as per rating of MCCB’s including aluminium lugs to connect the cable dismantled before etc., and comprising of the following:-
(a) MCCB 125 amps, 4 pole with breaking capacity 25KA (Adjustable thermal & magnetic release) - 01 No (Incomer) (b) MCCB 125 amps, 4 pole with breaking capacity 25 KA (Adjustable thermal & magnetic release) - 1 No (Spare) (c) MCB DP 32 amps, 'C' Curve, breaking capacity 10 KA - 8 Nos (outgoing) (d) Digital LED voltmeter, 3 phase, class 0.5 - 01 No. Make. Schneider Model No.DM3210 (e) Digital LED ammeter, 3 phase, class 0.5 - 01 No. Make. Schneider Model No.DM3110 (f) 3 Nos Phase indication LED lamps RYB - 1 Set (g) CT's 200/5 - 01 Set Make.L&T/ AE/ Shanti/ Legrand/ Lappa/ Pragati Location - Block No. 221, 222, 223, 224, 225, 248, 249, 250 at Tarapore Vihar
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 150 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 120 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 95 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 70 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in any type of soil for foundation of pole, stay, taking up or laying of cable etc, complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included in the cost of excavation.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
Galvanised iron tube 80mm bore light grade (ISI marked) for cable protection to poles/ under floor/ under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound, complete all as specified & directed.
Galvanised iron tube 40mm bore light grade (ISI marked) for cable protection to poles/ under floor/ under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound, complete all as specified & directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL), connected to galvanized iron earth strip 32x6mm size by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 50mm bore 'light grade' galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt etc including connected to test point and testing on completion, complete all as shown in electrical plate No 3 of SSR Part-I 2009 & as directed.
Vishesh Engineers
SUMEET TRADING CORPORATION
SATISH AND CO
ANIKET TRADERS
M/S MANU ENGINEERS AND CONTRACTORS
MAMTA ENTERPRISES
M/S PRAJAPATI ENGINEERS
Kay Bee Traders
N K BUILDERS
KAMAL CONSTRUCTION
M/S RAJ ENGINEERS
GENESIS INDIA
M/S Sudagar Mal
ASHISH CONSTRUCTION COMPANY
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .