Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.0 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹44.5 L+₹50,744.36 (1.15%)Rejected-Finance 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | L2 | Rejected-Finance High Rate | |
| 3 | L3₹45.3 L+₹1.3 L (2.96%)Rejected-Finance 11 97 SADALATLIGUDA CHOWDARIGUDA HYDERABAD TELANGANA 500088 | MEDCHAL MALKAJGIRI | TELANGANA | 500088 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹46.5 L+₹2.5 L (5.62%)Rejected-Finance | L4 | Rejected-Finance High Rate | |
| 5 | L5₹47.0 L+₹3.0 L (6.93%)Rejected-Finance | L5 | Rejected-Finance High Rate |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
26 Apr 2022, 6:00 pmClosed
GE NDA KHADAKWASLA
GE NDA KHADAKWASLA
PROVN OF ALTERNATE DI PIPE LINE FOR BOOSTER PUMP HOUSE AND PROVN OF EXTERNAL ELECTRICAL FITMENT AT D2-38 D2- 42 AND C-03 AT NDA KHADAKWASLA
2022_MES_499319_2
8573/E8
Open Tender
Civil Works
Item Rate
180 days
GE NDA KHADAKWASLA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE NDA KHADAKWASLA
₹95,000
Yes
20 May 2022
7 Apr 2022
28 Apr 2022
8 Apr 2022
26 Apr 2022
14 Apr 2022
8 Apr 2022 - 13 Apr 2022
Amount
Excavation in trenches in soft / loose soil not exceeding 1.5 metre wide and not exc 1.5 metre in depth and getting out for taking out / laying of pipes and making bottom surfaces of excavation leveled.
Ditto all as per item No 1 above but additional depth exc 1.5 mtr and not exc 3.0 mtr beyond the first 1.5mtr
Excavation in trenches in Hard/dense soil with mechanical chiesling exceeding 1.5 metre wide and not exc 1.5 metre in depth and getting out for taking out / laying of pipes and making bottom surfaces of excavation leveled.
Ditto all as per item No 3 above but additional depth exc 1.5 mtr and not exc 3.0 mtr beyond the first 1.5mtr
Returning, filling in trenches with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as directed
Removing surplus soil / spoil to a distance not exceeding 50 metre away and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as directed
Supply & Lay Ductile Iron Pipe 250mm dia K-9 Class Spigot & Socket type with all necessary fitting and fixture any type complete all as directed
Cutting/ Screwing existing CI/DI pipe insertion 300x300x250mm Tee, short nipple,union for branch conection of the internal pipe dia 250mm alteration or addition complete all as specified and as directed.
M&L for ductile iron fittings such as bends (any type, radius , angle) tapers any type (straight,bend,increasing, decreasing or double socket etc),Tee piece,single branch Y junction double branch collar,blank flanged etc caps and plugs etc as per IS:9523-2000 of class K-12 PN -10 with internal cement mortor lining and external cement motor lining and external zinc black bitumen coated of dia 200-300 mm complete all as specified and directed.
M&L for valve pit chember of size 900x900x750 mm (Internal Dimension) with block (1:3:6) type C1 set in CM (1:4) massioary including all necessary excavation and earth work in any type of soil, returning filling and disposal of spoil to a distance .exc 50m and depositing where directed, PCC in foundation of the mix (1:4:8) type D-2 (Using 40mm graded stone cruched stone aggregate) brick mesonary 15 mm thick plaster work in CM 1:4 over all internal and external wall with white wash of both surface and MS sheet cover of suitable thickness for with hinges, equal angle iron frame and necessary locking arrangement over 50 mm thick PCC (1:2:4) tpye B1 coping painting of synthetic Enamel paint over coat of red oxide primer on MS Plate complete all as specified and directed .
S&F in replacement Sluice Valve CI class PN 1.6 flanged type 300mm, ISI marked with hand wheel for operation, Non- Rising SS stem, bronze body seat ring, ISI markedincluding all minor fixing arrengement complete all as directed. Make Zoloto Atr No 1079B or equivalent in Kartar/ Packs
S&F in replacement Sluice Valve CI class PN 1.6 flanged type 250mm, ISI marked with hand wheel for operation, Non- Rising SS stem, bronze body seat ring, ISI markedincluding all minor fixing arrengement complete all as directed.Make Zoloto Atr No 1079B or equivalent in Kartar/ Packs
S & F mechanical joint collar/adaptor cylindrical shape of CI Pipe of having diameter of 300mm complete all as specified and directed
M&L for cutting existing road including black top cover (trench) up to 1 Mtr depth and width not exc 60cm for laying of pipe line, refilling and making good after laying of pipe with removed soil and finally sealed with cement concrete (1:2:4) type B1 of thickness not less than 150mm to match with the top surface of Road complete all as specified & Directed.
S&F 18 watt LED outdoor light made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP 65 Make Luker Cat pat No LGLSBG-27or eqv in Bajaj/Havells
S&F Integral LED 18 watt outdoor light made in diecast aluminium housing with decorative clear opal acrylic diffuser and IP 65 on PCC foundation with suitable nut and bolts as per site requirement complete all as specified and directed Make- Luker Cat No LOBRD60 or eqv in Havells/Bajaj
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium multistrand conductor, 1100 volts grade, cross sectinal area 4 sqmm 4 core complete all as specified and directed.
S & F PVC insulated copper conductor 3 core 1.5 sqmm for from busbar to fitting ,multistranded complete all as specified and directed. Make Polycab/Havells/Standard
M&L for PCC (1:3:6) type C-2 (Using 40 mm graded stone aggregate) Cement concrete in foundations, filling and mass concrete for bollard lights complete all as directed.
M&L for PCC (1:2:4) type B-2 (Using 40 mm graded stone aggregate) Cement concrete coping of bollard lights including necessary from work complete all as directed.
M&L for cutting in existing road crossing by providing suitable T &P to make suitable size bore for fixing 40 mm dia pipe in road crossing etc omplete all as specifed and directed. Note: 1. Quoted rate shall be incl of 40 MM GI medium grade pipe. 2.Quoted rate shall deemed to incl the cost of making good in cement concrete (1;2;4) type B (Using 20 mm graded stone aggregate) the disturbed surface and match with existing.
S&F distribution box 2 Module 230V, 5 HZ, IP-65 & IK-09 Class-II, weatherproof cabinets, door and cabinet fully reversible, removable chassis and faceplates, including weatherproof glands, rails qty-1 Nos, coppper fork type 100 A busbars as short link including end caps, qty-1 nos, MCB SPN 06 Amp 230V, 50 HZ, complete all as specified and directed Make: Legrand Catpart No 601932 or equvaleint in L&T/Schinder
S&F 100 watt white flood light luminaire die cast housing and heat sink in aluminium extrusion and IP 65 , fixing on wall /pole using by suitable MS channel and 40 mm medium grade GI pipe up to 3.5 meter height complete all as specified and directed Make Luker cat No LFL100 or equivalent in Havells/ HPL/ Jaquar
Supply and laying 50 mm outer dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection complete all as specified and directed Make : as per sample approved by Engr-in-Charge
S&F of sintex box thermo plast (weather proof) IP 66, on flood light poles made out of thermoplastic of size 140mm x 140 mm x 95 mm size with connector for connecting incomming and outgoing of cable including 01 No of MCB SP 6 Amps to control the pole light circuit and MS brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and wahers and suitable size of double compression cable glands for incomming, outgoing of cable Complete all as specified and directed Make Sintex Cat pat No GSJB-1414 or equivalent in any other approved makes.
S&F GI tubing light grade 40 mm dia isi marked appx 3 mtr to 3.5 mtr long with Flat Iron Base for mounting of Flood light with all fittings incl nut,bolt,washers suitable size and also make the hole for pole for entry of the 1.5 sqmm PVC conductor complete all as specified and directed at site.
Returning & filling trenches with excavated soft rock including spreading, levelling, watering & well ramming in layers n.exc .25 cm complete all as directed
Removing executed soft rock to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as directed
KESARI AND SONS
Deccan Enterprises
Sparkh Electricals & Works
M/S JEELANI ELECTRICALS
Aziz Traders
Takshashila electricals
Prasur Electricals & Engineering Co.
SONU ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .