Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.7 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹69.6 L+₹85,755.35 (1.25%)Rejected-Finance VILL DANNA PO TEH BASANTPUR DIST KATHUA JAMMU KASHMIR | BASANTPUR | KATHUA | JAMMU KASHMIR | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹71.1 L+₹2.4 L (3.50%)Rejected-Finance 5 A LANE 1 GREATER KAILASH JAMMU J K 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹73.8 L+₹5.0 L (7.35%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹73.8 L+₹5.1 L (7.42%)Rejected-Finance H NO 39 3 CHANNI HIMMAT JAMMU 180015 J K | JAMMU | JAMMU AND KASHMIR | 180015 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹75.3 L
EMD Value
₹1.4 L
Closing Date
27 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL S PRADEEP,CWE
Military Engineer Works HQ CWE Jammu
PROVN OF NIGHT PICKET GUARD ROOM WITH TOILET AND BATHROOM AND ALL CONNECTED SERVICES NEAR POST NO 03 AND 05, PATHWAY OF POST NO 23 TO 27 UNDER GE SATWARI
2024_MES_636012_3
CWE/JP-56/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE Satwari
Please refer tender documents
9 documents required · 9 mandatory
₹1,000
Satwari
₹1.4 L
Yes
6 May 2024
8 Feb 2024
29 Feb 2024
8 Feb 2024
27 Feb 2024
15 Feb 2024
Amount
Note :-Execution of work vide Srl item No 1 to 87 of BOQ, shall be strictly as per Drg No GE/SAT/WD-01/2023 sheet No 1/1 and Note No 7 of abvoe Drg. Tenderers are requested to compare items of BOQ to their estimat and any items found to be indvertantly left out in BOQ, be brought to the notice of this office timely for its inclusion in tender documents. However cost of any minor items shown in Drg No GE/SAT/WD-01/2023 but leftout indvertantly, shall be deemed to be included in the quoted rates of other BOQ items.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables, pipe line, pole etc. not exceeding 10Sqm on plan and not exceeding 1.5mtr in depth and getting out, in any type of soil, complete all as specified and as directed.
Spreading and levelling in layers not exceeding 25cm thick,watering and well ramming in layers as in floors with earth obtained from excavation complete all as specified and as directed.
Removing excavated materials/ soils, to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and as directed.
Plain cement concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation, filling, sub base and mass concrete, complete all as specified and as directed.
RCC M-25 (design mix), using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beam; plinth beams; bases of columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed.
RCC M-25 (design mix), using 20mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts, complete all as specified and as directed.
RCC M-25 (Design Mix) using 20mm graded crushed stone aggregate as in beams ,cantilevers, bressummers, lintel over 1.5mtr span complete all as specified and as directed.
RCC M-25 Design mix, (using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, to obtain rough finished flat surfaces of concrete, complete all as specified and as directed.
Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions etc, square, rectangular or polygonal, to obtain rough finished flat surface of concrete, complete all as specified and as directed.
Use and waste of form work to sides and soffits of floor or roof beams, beams haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc to obtain rough finished flat surface of concrete, complete all as specified and as directed.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs exceeding 20cm wide, etc. to obtain rough flat finished surface of concrete, complete all as specified and as directed..
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6mtr mean radius built in cement mortar 1:6, complete all as specified and as directed.
Brick work with old size sub class 'B' bricks, straight or curved on plan to any radius in half brick thick built in cement mortar 1:4, complete all as specified and as directed.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed.
TMT mild steel bars, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire (annealed not less than 0.9mm dia) , complete all as specified and as directed.
75mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in sub base to floors, complete all as specified and as directed.
Sand filling under floors or in foundations including watering and consolidation, complete all as specified and as directed.
Supply & laying dry bricks over cable as mechanical protection layer flat with width equal to length of brick with sub class 'B' bricks complete all as specified and as directed.
Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness M-35 Grade with grey cement and pigment, complete all as specified and as directed.
Cement concrete 1:2:4 type B-1, (Using crushed 20mm graded stone aggregate) cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets, copings, kneelers, apex stones, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed
75mm thick plain cement concrete 1:4;8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base to floors, complete all as specified and as directed.
Plain cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate), nominal mix, 25mm thick, as in floors, finished even and fair, complete all as specified and as directed.
Non - skid anti scratch, anti fungus, digital Ceramic coloured joint less tiles 8 to 10mm thick (square/ rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15 mm thick screed bed cement mortar 1:4, complete all as specified and as directed.
Glazed ceramic tile 450mm x 300mm x 8mm thick on vertical surface as in skirting/dado etc set and jointed with neat cement slurry and pointed with white cement mixed with colour to match the tile, complete all as specified and as directed.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement, complete all as specified and as directed.
Rendering 15mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
Rendering 5mm thick on fair faces of brick work or concrete surfaces in ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed.
Plain cement concrete 1:3:6 type C-1 (using 12.5mm graded crushed stone aggregate) as in surface channel and drain including all necessary form work, complete all as specified and as directed.
Machine cut kota stone slab flooring 20-25mm thick over cement screed bed laid and jointed cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete for tread of staircase over and including 15mm thick screed bed in cement mortar 1:4, complete all as specified and as directed.
Machine cut kota stone slab 15-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete for risers of staircase over and including 10mm thick fair and even plaster in cement mortar 1:4 after roughing surfaces of old concrete/any type of plaster by picking sweeping down with water to remove dust etc., complete all as specified and as directed.
Pressed steel frame of size 125x60mm for doors with double rebated including mild steel hinges medium weight 100 mm long and 25x3 mm flat iron in hold fast, tie bar including necessary fixing lugs, lock, strike plate and fixing arrangement with and including back filling of chowkats in PCC 1:3:6 type B-0 and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Steel window 1.25mm thick Box type (Double Shutter) ERW hollow P section of size 60mm x 25mm single rebated comprises glazed & wire gauged skelton shutter ERW sec 50mm x 20mm and 1mm thick with two Nos sash bar of T- section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC 1:2:4 type B-1 four No for each window including following fitting welded to frame shutter hold fast of 150mm long of 12mm x 3mm FI made to shape 4 No, handle of Z section 20mm x 25mm x 100mm long 1 No per leaf, MS tower bolt 150mm long 2 No per leaf, Z sec 20mm x 25mm, 100mm long stopper 1 No on per leaf, MS Pintel hinges of size 75mm x 12mm 2 No per leaf fabrication, 10mm Square bar gril, spacing of gril 100mm center to center and fixing arrangement as per drg No CEPZ/TD-324,325/0 ( Note:- Grill measured separately)
Steel Ventilator ( not exc 0.70Sqm) 1.25m thick Box type (Double Shutter) ERW hollow P section of size 60mm x 25mm single rebated comprises glazed & wire gauged skelton shutter ERW sec 50mm x 20mm and 1 mm thick with two Nos sash bar of T- section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC 1:2:4 type B-1 four No for each window including following fitting welded to frame shutter hold fast of 150mm long of 12mm x 3mm FI made to shape 4 No, handle of Z section 20mm x 25mm x 100mm long 1 No per leaf, MS tower bolt 150mm long 2 No per leaf, Z sec 20 mm x 25 mm, 100mm long stopper 1 No on per leaf, MS Pintel hinges of size 75mm x 12mm 2 No per leaf fabrication, 10mm Square bar gril, spacing of gril 100mm center to center and fixing arrangement as per drg No CEPZ/TD-324,325/0 ( Note:- Grill measured separately)
Mild steel works of flat iron, square bar, round bars etc. as in framed work such as grills, guard bars, gratings etc incl bending, cutting and welding as necessary of confirming to Gde Fe 310-0 complete all as specified and as directed.
Supply only liquid water proofing compound,complete all as specified and as directed.
Vitreous China wash basin, white, flat back, size 580mm x 450mm excluding taps, waste, chain and plug and porcelain stopper including brackets of any size, including cutting for and pinning in ends of brackets or erecting stand including fixing and supply of waste pipe of 32mm dia, waste coupling of PTMT (half or full threaded), and PVC connection 15mm dia 450mm long complete all as specified and as directed.
Tubular towel rail, 20mm dia, D type, 60cm long between flanges, chromium plated fixed to walls with chromium plated brass screws, fixing in repairs, complete all as specified and as directed.
Vitreous China squatting pan 'Orissa' pattern size 580mm x 440mm white with integral foot rest with 'P' or 'S' trap (excluding flushing cistern and flush pipe) and provision of lime concrete and making good floor, complete all as specified and as directed.
10 litres capacity PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets including PVC flushing pipe 32mm bore as required and a pair of bracket etc., complete all as specified and as directed.
Vitreous china bowl urinal flat back, size 465mm x 355mm x 265mm, white, with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete, fixed in repairs complete all as specified and as directed.
Vitreous china urinal partition white of size 310mm x 700mm, fixed in repairs, complete all as specified and as directed.
PVC (SWR) pipes, 150mm bore, single socketed, in any length with rubber ring joints, laid in trenches/fixed on walls, complete all as specified and as directed.
PVC (SWR) pipes, 110mm bore, single socketed, in any length with rubber ring joints, laid in trenches/fixed on walls complete all as specified and as directed.
PVC (SWR) pipes, 75mm bore, single socketed, in any length with rubber ring joints, laid in trenches/fixed on walls, complete all as specified and as directed.
PVC (SWR) bends of 110mm bore, any radius, complete all as specified and as directed.
PVC (SWR) bends of 75mm bore, any radius, complete all as specified and as directed.
PVC (SWR) floor trap, plain with grating including jointing with solvent cement for bore of pipe 75mm dia complete all as specified and as directed.
Rotational moulded polyethylene water storage tanks of 1000 litres capacity,triple layered white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, complete all as specified and as directed.
Galvanised iron pipe 15mm bore medium grade with screwed joint together with all fitting such as bends, elbows,tees,short pieces and union etc fixed to walls or laid in floors including all fittings, complete all as specified and as directed.
Galvanised iron pipe 20mm bore medium grade with screwed joint together with all fitting such as bends, elbows,tees,short pieces and union etc fixed to walls or laid in floors including all fittings, complete all as specified and as directed.
GI pipe ''light grade'' for road crossing / on wall / on pole with fixed clamps, nuts, bolts for cable protection of size 40mm dia, complete all as specified and as directed.
Steel tubing galvanized medium grade with all fittings laid in trenches/ walls / Ceiling/ floor of size 25mm dia, complete all as specified and as directed.
Gun metal globe or gate valves of size 25mm, with iron wheel head,screwed both ends for iron pipe and fixed, complete all as specified and as directed.,
Fancy type CP stop valves, concealed type,cast copper alloy chromium plated with long shank and cup, screwed both ends for iron pipe or for unions and fixed for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
PVC connections 15mm size with PTMT nuts of length 600mm, complete all as specified and as directed.
Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed for 15mm bore pipe, complete all as specified and as directed.
Plain cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate), 75mm thick, as in plinth protection and providing the joints throughout the thickness, filled with mastic filling comprising bitumen 85/25 grade and sand mixture 1:3 by weight, complete all as specified and as directed.
Mild steel as in doors or gates frame including ,drilling holes, welding , etc and similar work conforming to Fe-290 Gde E-165 etc., complete all as specified and as directed.
Mild steel small articles such as hold fasts etc conforming to Fe 290 Gde-E-165, complete all as specified and as directed.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawing, complete all as specified and as directed.
35mm thick 2nd class soft wood, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply. The size of rail and stile as per IS : 1003 (Part I), complete all as specified and as directed.
35mm thick 2nd class soft wood glazed and skeleton shutters open rebated and prepared to receive gauge etc without sash bar but with lock rail fitted with cut and mitered beads, complete all as specified and as directed.
Butt hinges, size 100mm, medium weight, cold rolled mild steel, and fixed, complete all as specified and as directed.
Aluminium anodised, barrel tower bolts of extruded Section, size 150mm long and fixed, complete all as specified and as directed.
Aluminium handles, cast type, anodised, size 150mm, complete all as specified and as directed.
Aluminium alloy, anodised, sliding door bolt Size 250mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed.
Applying two coat of synthetic enamel paint on new wooden surfaces of any description over a coat of pink primer having width/girth exceeding 10cm complete all as specified including preparation and necessary filling by chalk putty as and where required to make surface even and smooth, complete all as specified and as directed.
Two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces including preparation of new surface over 10cm width or girth, complete all as specified and as directed.
Galvanized mild steel wire cloth of 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tack or galvanized wire staples, complete all as specified and as directed.
3mm thick sheet glass ordinary quality and glazing with oil putty in area not exceeding 0.5Sqm in each pane complete all as specified and as directed.
Preparation of new plastered or unplastered surfaces of walls and applying three coats of white washing, complete all as specified and as directed.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of wall care putty 1mm thick, complete all as specified and as directed.
Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white washing, complete all as specified and as directed.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of cement based paint over and including one coat of primer, complete all as specified and as directed.
Preparation of concrete /plastered surface by scrubbing down with steel brushes and cleaning with water all loose dirt / dust and applying roof treatment as below:-- (i) Rendering 15mm thck in cement mortar 1:4 mixed with integral Water proofing compound on concrete surface in roofs including applying cement slurry @ 3 Kg/Sqm finishing even and fair without using extra cement ( WPA shall be measured separately) (ii) Applying 1st coat of bitumen primer 0.4ltr/Sqm of density at 25 degree C’ 0.87-0.89Kg/Litre and viscosity 70-160 CPS till the surface properly impregnates and insolvent oil primer evaporates completely (iii) Applying 2nd course of a coat of blown type bitumen of grade 85/25 heated to a temperature of 180 degree centigrade and applying @ 1.2Kg/Sqm completely
Srl item No 79 Contd … (iv) Applying 3rd course of Polymeric Polypropylene polymer membrane “APP” (Atactic poly propylene polymer ) modified prefabricated five layer 3mm thick not less than 3.6 Kg/Sqm with 160 grams non woven polyster made at centre core reinforced laid with 75mm side overlap and 100 overlap in length using butane torch with 10cm over laps which shall be thermo fused by flame. (v) Applying course of two coats of aluminium paint over the APP membrane all as specified. All joints and change in direction shall be covered with cement mortar 1:3 mixed with SBR latex @ 200ml/bag of cement and curved before laying membrane. Note : Ponding shall be done over RCC slab by filling water which shall be kept for 48 hours. In case a slightest indication of seepage / leakage is noticed the same shall be rectified by grouting the affected portion at no extra cost.There after ponding test shall be repeated till there is no indication of seepage /leakage before application of roof treatment. A proper record of ponding test of RCC slabs shall be maintained by Engr in Charge. The arrangement of ponding test shall be made by the contractor and shall be included in the quoted rates.
Chequered cement concrete tiles 30cm x 30cm x 20mm thick, set, jointed and pointed in neat cement slurry in floors and including 15mm thick screed bed with cement mortar 1:6, complete all as specified and as directed.
HDPE Double wall corrugated pipe with 150mm (SN-8) with integral socket and necessary fittings,laid in trenches jointed, complete all as specified and as directed.
Precast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in manholes cover slabs for septic tank and including necessary form work and set in cement mortar 1:6, complete all as specified and as directed.
Mild steel as in Man hole cover frame including ,drilling holes, welding , etc., and similar work conforming to Fe-290 Gde E-165 etc., complete all as specified and as directed.
Construction of septic tank for 10 users, excavation in any type of soil, foundation in PCC 1:2:4, brick work in cement mortar 1:4, RCC M-25 design mix slab covers including RCC precast manhole covers having 6mm thick plate embedded all round/ fibre reinforced cover with angle iron frame vent shaft and sludge chamber etc complete all as specified and shown in Drg No CEPZ-C-TD/013/13 Sheet No-01 to 05.
Construction of soakage wells built in brick construction, excavation in any type of soil, foundation in PCC 1:3:6, wells of honey combed and solid in M-25 Concrete, RCC cover slab in M-25 & filling with brick bats, complete of size 2.4m dia X 3.0m deep complete all as specified and shown in Drg No CEPZ-C-TD/013/13 Sheet No-01 to 05.
Extra for forming fair finished drain or channel upto 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.
Cutting existing cast iron /GI pipe in position for insertion of CI specials or GI fittings viz Tee,collar,bend or tail piece etc for 80 to 200 mm bore pipe including removing of blockage,cleaning of pipe line, complete all as specified and as directed.
Construction of valve pit chamber having internal dimension 0.6m x 0.6m and depth 0.75m made of brick wall (full brick wall) with subclass 'B' bricks, straight or curved on plan exc 6m mean radius and built in cement mortar 1:6. incl plastering exposed surfaces with cenent mortar1:4 and provn of pre cast valve pit cover of RCC, 50mm thick with opening handle, complete all as specified and as directed.
Cutting of bituminous road / floor / culvert / PCC hard standing for laying of pipe / cables not exceeding 1.5meter wide and not exceeding 1.5meter deep including refilling / with material and , watering well ramming / compacting and making good with PCC 1;2;4, type B-1, 100mm thick, complete all as specified and as directed.
Fixed in replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium stranded conductor, Armoured cable 16Sqmm 4 core cable confirming to IS-7098 Part-I (1988) with latest ammendments of sizes., complete all as specified and as directed.
Point wiring complete with 1.5Sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLSH grade with multistranded copper conductor ISI marked drawn through medium duty PVC concealed conduit fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5Sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly, including concealed MS box with 3 mm thick laminated sheet cover fixed with brass screws and cup washers for mounting of plate mounting for housing the switches, socket outlets, fan regulators etc, all as specified and as directed for the following .
One Light / Exhaust Fan point controlled by one, one way switch 6 Amp, complete all as specified and as directed.
One 3 pin socket outlet 6 amp independent,complete all as specified and as directed.
One 3 pin socket outlet 6 amp same board,complete all as specified and as directed.
All as per description of srl item No 92 above but for one 3 pin socket outlet 16 Amp independent with cable of size 2.5Sqmm for point wiring complete all as specified and as directed and 2.5Sqmm as in continuous earth wire,
Switch piano, flush type single pole, one way 6 Amp capacity, complete all as specified and as directed.
Socket out let 2 in 1, 5 Pin, 6Amp combined 2 module complete all as specified and as directed.
Switch piano, flush type single pole, one way 16 Amp capacity, complete all as specified and as directed.
Socket out let 2 in 1, 5 Pin, 16Amp combined 2 module, complete all as specified and as directed.
Ceiling rose surface, bakelite, three terminal, 240 volts, complete all as specified and as directed.
LED light fitting 1 x 18Watt, 220V, AC decorative box type with driver, holder including LED Tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed. Note:- The LED batten and LED tube rod shall be of same make.
Lamp holder,PVC /Polycarbonate type with back plate for batten fitting, complete all as specified and as directed.
LED lamp suitable for B-22 holder of capacity 10 Watt, complete all as specified and as directed.
Energy saving new generation 10W LED IP65 bulk head luminaire with opal diffuser, complete all as specified and as directed.
Distribution Board (SPN) double door 12 Way and should be IP 43 protected with Copper Bus bar 100 Amp rated ,Earth Bar ,neutral Bar Door Earthing, complete all as specified and as directed.
MCB TPN, 63 Amp with 240 Volts, rupturing capacity 10 KA 'C' series, complete all as specified and as directed.
MCB Single pole 6 to 32 Amp with 240 Volts, rupturing capacity 10 KA 'C' series, complete all as specified and as directed.
Ceiling fan complete with blade, down rods, and accessories, 230 V, 1200mm sweep, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and connected from ceiling rose/ connector with & including suitable size flexible copper conductor PVC insulated sheathed cord, complete all as specified and as directed.
Exhaust fan, steel body AC single phase. 230 V of size 300mm sweep with, blades, and frame and louvers and including making of holes in wall, floor etc., complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25mtr deep below ground level) with top edge of plate not less than 1.5mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 4Kg/Sqm. (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 111 Contd … (e) 15mm nominal bore light grade GI protection pipe 7.5mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Ms International Engineers
NARESH KUMAR AND COMPANY
M/S VED PAUL MAHAJAN
M/S ANIL MAHAJAN
M/S ARUN ANAND
JK BUILDERS AND DEVELOPERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .