| 1.00 | Rectification of SF-6 gas leakage from poles of 145KV SF-6 CGL Make circuit breaker (Mfg. year 2002 Sr. No. 16372C ) of 40 MVA T/F-1st HV side bay at 220KV Sub-station Sitapur. Work consists of (a) To identify SF-6 Gas leakage with the help of SF-6 gas leakage detector and pole non-operating problem (b) Dismantling of identified pole from breaker structure with the help of hydra (c) Dismantling of all components of poles and replace all "O" rings/Gas kit by applying Anabond 661 (Gas Seal Out) after thorough cleaning of part. (d) Replacement of pull rod for pole moving contact. (e) Re-assemble all parts of the pole. (f) Apply vacuum and keep it for 24 hrs and check no loss of vacuum (g) Erection of poles on structure using hydra (h) Filling of SF-6 gas upto soecified value (i) check satisfactory Close/Trip operation both by local and remote. | 3 | Job | 75,000 ₹2,25,000 | 59,000 ₹1,77,000 | 52,200 ₹1,56,600 Lowest |
| 2.00 | Rectification of SF-6 gas leakage from poles of 145 KV SF-6 ABB Make circuit breaker (Mfg. year 2006 Sr. No 17000982) of 160 MVA T/F LV side bay at 220 KV Sub-station Sitapur. Work consists of (a) To identify SF-6 Gas leakage with the help of SF-6 gas leakage detector and pole non-operating problem (b) Dismantling of identified pole from breaker structure with the help of hydra (c) Dismantling of all components of poles and replace all "O" rings/Gas kit by applying Anabond 661 (Gas Seal Out) after thorough cleaning of part. (d) Replacement of pull rod for pole moving contact. (e) Re-assemble all parts of the pole. (f) Apply vacuum and keep it for 24 hrs and check no loss of vacuum (g) Erection of poles on structure using hydra (h) Filling of SF-6 gas upto soecified value (i) check satisfactory Close/Trip operation both by local and remote. | 3 | Job | 75,000 ₹2,25,000 | 59,000 ₹1,77,000 | 52,200 ₹1,56,600 Lowest |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
8 Apr 2026, 6:00 pmClosed
SE ETC Shahjahanpur
Electy Trans Circle Shahjahanpur
Work
2026_UPTCL_1131634_1
90 ETC(S)/2025-26
Open Tender
Electrical Works
Fixed-rate
60 days
Sitapur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
A/c No. 0423002100107147 IFSC Code No. PUNB0042300
₹5,000
9 Sept 2026
30 Mar 2026
9 Apr 2026
30 Mar 2026
8 Apr 2026
30 Mar 2026
30 Mar 2026 - 8 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Rectification of SF-6 gas leakage from poles of 145KV SF-6 CGL Make circuit breaker (Mfg. year 2002 Sr. No. 16372C ) of 40 MVA T/F-1st HV side bay at 220KV Sub-station Sitapur. Work consists of (a) To identify SF-6 Gas leakage with the help of SF-6 gas leakage detector and pole non-operating problem (b) Dismantling of identified pole from breaker structure with the help of hydra (c) Dismantling of all components of poles and replace all "O" rings/Gas kit by applying Anabond 661 (Gas Seal Out) after thorough cleaning of part. (d) Replacement of pull rod for pole moving contact. (e) Re-assemble all parts of the pole. (f) Apply vacuum and keep it for 24 hrs and check no loss of vacuum (g) Erection of poles on structure using hydra (h) Filling of SF-6 gas upto soecified value (i) check satisfactory Close/Trip operation both by local and remote. | 3 | Job | - | - |
| 2 | Rectification of SF-6 gas leakage from poles of 145 KV SF-6 ABB Make circuit breaker (Mfg. year 2006 Sr. No 17000982) of 160 MVA T/F LV side bay at 220 KV Sub-station Sitapur. Work consists of (a) To identify SF-6 Gas leakage with the help of SF-6 gas leakage detector and pole non-operating problem (b) Dismantling of identified pole from breaker structure with the help of hydra (c) Dismantling of all components of poles and replace all "O" rings/Gas kit by applying Anabond 661 (Gas Seal Out) after thorough cleaning of part. (d) Replacement of pull rod for pole moving contact. (e) Re-assemble all parts of the pole. (f) Apply vacuum and keep it for 24 hrs and check no loss of vacuum (g) Erection of poles on structure using hydra (h) Filling of SF-6 gas upto soecified value (i) check satisfactory Close/Trip operation both by local and remote. | 3 | Job | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.15 MB
BOQ_2111683.xls
BOQ • 0.27 MB
report.pdf
PDF • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .