| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 CrAccepted-AOC | ₹7.9 Cr | L1 | Accepted-AOC The bidder is responsive as amount quoted is less than 15 percent as per World Bank Norms. |
| 2 | L2₹7.9 Cr+₹1,356.70 (<0.01%)Rejected-AOC | ₹7.9 Cr+₹1,356.70 (<0.01%) | L2 | Rejected-AOC The bidder is non responsive as amount quoted is more than 15 percent as per World Bank Norms. |
| 3 | L3₹9.8 Cr+₹1.9 Cr (23.9%)Rejected-AOC KHALINI DISTT SHIMLA | SHIMLA | SHIMLA | HIMACHAL PRADESH | ₹9.8 Cr+₹1.9 Cr (23.9%) | L3 | Rejected-AOC The bidder is non responsive as amount quoted is more than 15 percent as per World Bank Norms. |
Tender Value
₹6.2 Cr
EMD Value
₹12.3 L
Closing Date
30 Oct 2019, 2:00 pmClosed
Managing Director, HPMC
HPMC HO 3rd Floor, Nigam Vihar Shimla-2
Civil Work for Upgradation, Expansion and Strengthening of Existing Post Harvest Infrastructure of Jarol-Tikkar, District Shimla, HP
2019_HPMC_31807_1
HPHDP-PIU HPMC Works 17- Jarol-Tikkar
Open Tender
Civil Works
Item Rate
540 days
Jarol Tikkar
Please refer Tender documents.
8 documents required · 8 mandatory
₹5,900
Project Director
₹12.3 L
HPMC HO 3rd Floor, Nigam Vihar Shimla-2
12 Feb 2020
27 Sept 2019
30 Oct 2019
27 Sept 2019
30 Oct 2019
18 Oct 2019
10 Oct 2019
Amount
PACKHOUSE, CA STORES & OFFICE
Excavation in earth work and filling in 15 cm. layers in foundation and plinths including ramming, watering and consolidating upto a lead of 20 metres and lift upto a 1.5 metres.
Filling of available earth
Filling of carted earth.
Providing and laying cement concrete 1:4:8 (1 cement:4 sand:8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in: Foundation and plinth:
Sand Filling in plinth excluding supply of necessary quantity of sand from a distance not exceeding 8 km (5 miles) from the site of work & including watering,ramming , dressing etc rate to include cost of all materisls,labour and T&P etc. required for proper completion of the work.
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313 ( Part II 1981 ) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or chordancewill be used. The rate of application of chemical emulsion shallbe as follows : (1 Treatment for masonary & foundation 5 liters pe r/ 100 Sqm. (2) Back fill in immediate contact with foundation 7.5 liters / 100 Sqm. (3) Treatment of top surface of plinth filling 5 liters / 100 Sqm.(4)Treatment junction of wall and the floor 7.5 liters / 100 Sqm. (5)Treatment of soil along external perimeter of building 7.5liters / 10 Sqm.(6) Treatment of soil under apron along external perimter 5 liters / 100 Sqm.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Project Manager. All works upto plinth level, including the equipment foundation.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Project Manager.All All works above plinth level upto floor V level (COLUMN)
Ground Floor
First Floor
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Project Manager.All All works above plinth level upto floor V level (LINTEL BAND)
Ground Floor
First Floor
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Project Manager. All All works above plinth level upto floor V level (SUNSHADE)
Ground Floor
First Floor
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Project Manager.All All works above plinth level upto floor V level (BEAM)
Ground Floor
First Floor
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Project Manager.All All works above plinth level upto floor V level (SLAB)
Ground Floor
First Floor
Providing mild steel / Tor steel reinforcement Fe500 for RCC work including bending , binding and placing in position complete upto floor two level.
Ground Floor
First Floor
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (First Class Brick) in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying damp proof course 38 mm thick with cement concrete 1:2:4 ( 1 cement:2sand:4 stone agreegate 12.5 mm nominal size) and curing complete.
Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (First Class Brick) in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
Ground Floor
First Floor
Half brick masonry in common burnt clay building bricks in Cement Mortar 1:4 (1 cement : 4 sand) First Class Bricks
Ground Floor
First Floor
Providing and fixing flush door shutters decorative type core of block board construction with frames of first class hard wood and well matched first class indian teak plyveneering with vertical grains or cross bends and face vencering on both faces of shutter 35mm thick including black enamelled M.S. butt hinges
Ground Floor
First Floor
Mild Steel or iron work of small size and section such as hoding down bolts,hold fast,tie rods,gratings etc.(when not included in an over all rates) wrought to required form,including of supply of steel,bolts nuts and wastage etc and there fixing required for proper completion of the work. (fabrication of door frame - Angle iron door chaukhat including cost of hinges) 40x40x5mm -
Ground Floor
First Floor
Mild Steel or iron work of small size and section such as hoding down bolts,hold fast,tie rods,gratings etc.(when not included in an over all rates) wrought to required form,including of supply of steel,bolts nuts and wastage etc and there fixing required for proper completion of the work.(fabrication of grill & stair case railing)
Ground Floor
First Floor
Mild Steel or iron work of small size and section such as hoding down bolts,hold fast,tie rods,gratings etc.(when not included in an over all rates) wrought to required form,including of supply of steel,bolts nuts and wastage etc and there fixing required for proper completion of the work.(fabrication of Z section) openable
Ground Floor
First Floor
15mm cement plaster in single coat on fair side of brick/concrete/stone walls for interior plastering upto floor two level including arrises,internal rounded angles,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth ( Cement Mortar 1:6)
Ground Floor
First Floor
15mm Cement plaster in single coat on the rough side of brick/ concrete/stone walls for interior plastering upto floor two level including arrises,internal rounded angles,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth.(1Cement:6 Sand)
Ground Floor
First Floor
White glazed floor tiles 6 mm thick in 12 mm thick cement mortar 1:3 (1 cement :3 sand) and jointed with cement slurry.
Ground Floor
First Floor
White glazed wall tiles 6 mm thick in 12 mm thick cement mortar 1:3 (1 cement :3 sand) and jointed with grey cement slurry.
Ground Floor
First Floor
Kota stone flooring 20 mm (average) thick base of cement mortor 1:4 (1 cement :4 sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab. including rubbing and polishing complete.
Ground Floor
First Floor
Kota stone 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Ground Floor
First Floor
Providing and fixing 10mm thick anti skid water proof stain and impect resistent heavy duty vetrified tiles 600x600mmx10mm manufactured of approved shade and colour in flooring, treads of steps and landings laid over 12mm thick cement mortar 1:3 (1 cement : 3 sand) jointed with cement slurry mixed with pigment to match the shade of tiles as required complete. (Flooring)
Ground Floor
First Floor
Providing and fixing 10mm thick anti skid water proof stain and impect resistent heavy duty vetrified tiles 600x600mmx10mm manufactured of approved shade and colour in flooring, treads of steps and landings laid over 12mm thick cement mortar 1:3 (1 cement : 3 sand) jointed with cement slurry mixed with pigment to match the shade of tiles as required complete. (skirting)
Ground Floor
First Floor
Apply priming coat and enamel paint (two coats) over new steel and other metal surface after and including preparing the surface throughly cleaning oil grease dirt and other foreign matter and scoured with wire brushes,fine steel/wood scrappers sand preparing and knotting including cost of all materials,labour and T&P etc. required for proper completion of the work.
Ground Floor
First Floor
Painting two coats (excluding priming coat on new steel and other metal surfaces with enamel paint brushing to give an even shade including cleaning the surface of all dirt,dust and other external matters
Ground Floor
First Floor
Polishing two coats with malamine polish of required shade on new wood and wood based surfaces to give an even surface including cleaning the surface of all dirt, dust and sand papered smooth and including a coat of wood filler.
Ground Floor
First Floor
Applying Birla white wall care putty over plaster surface after thoroughly brushing the surface free from mortar drops, dust, loose materials and other foreign matters sand papered smooth to give final matter finish to the surface complete.
Ground Floor
First Floor
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Ground Floor
First Floor
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including water thinnable priming coat with cement primer
Ground Floor
First Floor
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 5mm thik
Ground Floor
First Floor
Providing Stainless steel Sliding Bolts 16 mm dia with nutx & 250 mm long
Ground Floor
First Floor
Providing Stainless steel Tower Bolt with 10 mm dia and screw 250 mm long
Ground Floor
First Floor
Providing Stainless steel Door Handles with screws 125 mm long
Ground Floor
First Floor
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry on First Floor
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainlesssteel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Project Manager, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) on Ground Floor
Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) Medium shade pigment using 50% white cement, 50% ordinary cement (Ramps).
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
Providing and fixing ball bearing for rolling shutters.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) (filling hold fast)
Ground Floor
First Floor
Providing and laying cement concrete Tremix flooring 150mm thick with cement concrete mix-25 and sprinkled with floor hardener of BASF Master top 100e or fosroc nito floor hard top standard @5kg/Sqm over vacuum dried Concrete, Mix with steel fibre dramix gallud-non balling 80/60 or equivalent @15kg/m3 of concrete and target 3 micro multi dimension fibrillated multifilament virgin PP fibre mix. @0.90kg/cum with shear dowel load transfer 16 mm dia., 400mm c/c in both direction X & Y and complete in all respects. The top of floor shall be covered with polythene immediately for one week. The slope of final floor shall be maintained as 1:500, complete job in all respects as per the direction of Project Manager.
Ground Floor
First Floor
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Project Manager .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
Providing form work with steel plates 3.15 mm thick welded with angle iron frame 30x30x5 mm so as to give a fair finish including centring shuttering strutting and proping etc. with wooden battens and ballies,height of proping and centring below supporting floor to ceiling not exceeding 4 mtrs.and removal of the same for in situ-reinforced concrete and plain concrete work in :
Foundation , footing basis of columns etc. and mass concrete.
Columns, pillars, posts and struts.
Beams, cantilever, girders and lintels.Sides and soffits of beams, beam haunching,cantilevers,bressumers and lintels 1 mtrs. In depth in all height.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick
Ground Floor
First Floor
Providing and applying 2 or more coats of tapecrete water proofing compound for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Project Manager. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.For vertical surface two coats @ 0.70 kg per sqm
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
RETAINING WALL
Excavation in earth work and filling in 15 cm. layers in foundation and plinths including ramming, watering and consolidating upto a lead of 20 metres and lift upto 1.5 metres.
Providing and laying cement concrete 1:4:8 (1 cement:4 sand:8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in: Foundation and plinth:
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Project Manager.All works upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Project Manager.All works above plinth level upto floor V level (COLUMN,WALLS)
Providing mild steel / Tor steel reinforcement Fe500 for RCC work including bending , binding and placing in position complete upto floor two level.
Providing form work with steel plates 3.15 mm thick welded with angle iron frame 30x30x5 mm so as to give a fair finish including centring shuttering strutting and proping etc. with wooden battens and ballies,height of proping and centring below supporting floor to ceiling not exceeding 4 mtrs.and removal of the same for in situ-reinforced concrete and plain concrete work in :
Foundation , footing basis of columns etc. and mass concrete.
Columns, pillars, posts and struts.
C. C. ROAD
Excavation in earth work and filling in 15 cm. layers in foundation and plinths including ramming, watering and consolidating upto a lead of 20 metres and lift upto a 1.5 metres.
Providing and laying cement concrete 1:4:8 ( 1 cement:4 sand:8 graded stone agreegate 40 mm nominal size) and curing complete excluding cost of form work in :Foundation and plinth:
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete and paint etc. as per direction of Project Manager (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Project Manager).
Providing & laying Cement Concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone ballast 20mm nominal size) including supply of all material labour and T&P etc. required for proper completion of the work and curing complete also including cost of formwork in foundation & floor
Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade 'A' sealing compound.
Providing miled steel / Tor steel reinforcement Fe500 for RCC work including bending , binding and placing in position complete upto floor two level.
Coloured inter locking C.C. paver Block (60 mm thick, M-35)
TOILET BLOCK
Tata Steel EzyNest 9ft * 4 ft modular toilets (3 toilet in row), Unit Size 1220 mm x 2745 mm x 2050 mm. WALL:Zero spangled cold rolled 120 GSM Galvanised (Galvano) powder coated 40 mm thick EPS panels ( EPS Density - 16 KG /m3, EPS thickness - 38 mm, Steel sheet thickness - 0.6 mm, 275 MPA), bottom 3 side panel SS304 grade layer up to 10 /12 inchs, CEILING: Zero spangled cold rolled 120 GSM Galvanised (Galvano) powder coated 40 - 70 mm thick taper roof EPS panels ( EPS Density - 16 KG /m3,EPS thickness - 38 mm, Steel sheet thickness - 0.6 mm, 275 MPA), FLOOR: Anti Skid tile finish floor inside toilet only, DOOR: Zero spangled cold rolled 120 GSM Galvanised (Galvano) powder coated with necessary stiffeners and Aluminium accesories (2 Al handles, 1 Al tower bolt, 1 Al L-drop). Door Size - 1790 mm * 655mm (Steel sheet thickness - 0.6 mm, 275 MPA), FASTNERS: Galvanised fastners, 2 Al handles, DOOR ACCESSORIES :1 Al tower bolt, 1 Al L-drop, VENTILATION: 3 side Zero spangled cold rolled 120 GSM Galvanised (Galvano) powder coated louvre panel for cross ventilation with EPS insulated panels. Provision for natural light above door, IWC: Provision of Indian Pan orissa pattern with antiskid tiled florring, PLUMBING: 1 PTMT Tap in each compartment, 200 Litre water Tank with tank frame, required pipes & necessary fitments, TAP: 1 PTMT Tap for each unit and 1 PTMT tap for each wash basin, WATER SUPPLY CONNECTIONS: PVC Pipe connection with all toilets interconnected and single inlet water supply point for Toilet, WASTE MANAGEMENT: Twin Leech pit with Insepction chamber : 1000mm dia and 1200 mm deep, made out of 40-50mm thick concrete rings/brick work with sufficient holes for the Leech pit to function effectively. 3" Thick RCC slab as top cover, made of 1:4:8 C:S:A. MS rings to be provided for lifting of slab. 1 Inspection Chamber: Soil Waste inspection chambers in 4 1/2 " brick work with inside dimension as 375mm x 375mm x 300mm depth.The same will be covered with a RCC top cover with MS hook. RCC cover will be 3" thick in 1:4:8 C:S:A. Inside surface of chamber will be finished with 10mm thick cement plaster in 1:4. The base will be 3" thick PCC in 1:5:10 Required Pipe connections between Toilet structure, IC and Leech Pit. CIVIL FOUNDATION DETAIL: Foundation • Brick Foundation of size 200mmX200mm with depth of 200mm from ground level for anchor/column locations. Pocket to be filled with PCC of 1:2:4 ratio after grouting of steel element of structure. • Plinth of height 300mm to be done with 5" first class brickwork using 1:5 mortar in periphery for the platform of size 1.125mx1.5m • Filling and ramming of 150mm using silver sand/good-earth • Single brick flat soling of 75mm height on filled-up area • Floor casting of 75mm thick PCC of 1:2:4 ratio above BFS • Outside Plinth plaster - 15mm thick on brick-work with CM 1:5 • Stairs (2 Nos) of 250mm wide x 900mm long x 150mm high
FIRE TANK
Excavation in earth work and filling in 15 cm. layers in foundation and plinths including ramming, watering and consolidating upto a lead of 20 metres and lift upto a 1.5 metres.
Providing and laying cement concrete 1:4:8 (1 cement:4 sand:8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in: Foundation and plinth:
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of EProject Manager (Foundation)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Project Manager.All All works above plinth level upto floor V level (COLUMN)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Project Manager.All All works above plinth level upto floor V level (beam) on ground floor
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Project Manager.All All works above plinth level upto floor V level (Slab) on ground floor
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Project Manager.All All works above plinth level upto floor V level (Wall)
Providing mild steel / Tor steel Fe500 reinforcement for RCC work including bending , binding and placing in position complete upto floor two level.
Providing form work with steel plates 3.15 mm thick welded with angle iron frame 30x30x5 mm so as to give a fair finish including centring shuttering strutting and proping etc. with wooden battens and ballies,height of proping and centring below supporing floor to ceiling not exceeding 4 mtrs.and removal of the same for in situ-reinforced concrete and plain concrete work in :
Foundation , footing basis of columns etc. and mass concrete.
Columns, pillars, posts and struts.
Beams, cantilever, girders and lintels.Sides and soffits of beams, beam haunching,cantilevers,bressumers and lintels 1 mtrs. In depth in all height.
40 mmthick cement concrete flooring with 25 mm under layer of cement concrete 1:3:6 (1cement :3 sand :6 stone aggegate of size 12.5 mm and below) and 15 mm weaking layer in cement concrete 1:2 to 3 (1 cement : 2 to 3 stone aggregate of size 4.75 mm and below) laid integral with base course and finished with a floating coat of neat cement.
Providing and applying 2 or more coats of tapecrete water proofing compound for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Project Manager. The product performance shall carry guarantee for 10 years against any leakage.
For horizontal surface one coat @1.10 kg per sqm.
For vertical surface two coats @ 0.70 kg per sqm
Rectangular shape 500x500 mm precast R.C.C. manhole cover with frame - M.D. - 10
INTERNAL/ EXTERNAL LIGHTING WORKS
200 PVC INSULATED HEAT RESISTANT FLAME RETARDANT AND LOW SMOKE (HRFRLS) COPPER CONDUCTOR WIRING IN PVC CONDUIT Wiring for light point / fan point / exhaust fan / call bell point with 1.5sqmm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required: Group C
Wiring for twin control light point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sqmm FRLSPVC insulated copper conductor single core cable etc as required.
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1No. 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 2x4 Sq. mm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC Conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 4x4 Sq. mm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC Conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit/sub-main with following size pve insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface / reccessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same Size for earthing as
2x1.5 Sq mm (For Light CKTs / Secondary Light Point)
2x2.5 Sq mm (For Chamber Light)
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke sirgle core (flexible) copper conductor cable in surface / recessed PVC conduit along with 2 No.10 Sq.mm. (4x10 + 2x10) HRFRLS/PVC insulated single core copper
Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke sirgle core (flexible) copper conductor cable in surface / recessed PVC conduit along with 2 No.16 Sq.mm. (4x16 + 2x16) HRFRLS/PVC insulated single core copper
600 SUPPLYING AND FIXING PVC CONDUITS: Supplying and fixing of 50 mm dia PVC conduit along with the accessories in surface / recess including cutting the wall and main good the same in case of recessed conduit as required :
800 SUPPLYING AND FIXING METAL BOXES: S/F Metal boxes following sizes (nominal size) on surface or recessed suitable for fixing phenolic laminated sheet cover in front including painting etc. as as required:
200mm x 150mm x 75mm deep
250mm x 300mm x 100mm deep
900 ERECTION OR FITINGS AND ACCESSORIES: Supplying and fixing GI Modular box of (100mmx75mmx50mm) size with modular plate and cover in recess including providing and fixing pin 5/6 amps modular socket, outlet and 5/6 amps modular switch connections etc. as required.
Supplying and fixing G.I. Modular box of (100mmx75mmx50mm) size with modular plate and cover In recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch connections etc. as required.
Supplying and fixing ceiling rose on the existing junction box / wooden block including connections etc. as required.
Supplying and fixing bakelite batten/angle holder including connections etc as required:
Supplying and fixing GI Modular box of (75mmx75mmx50mm) size with modular plate and cover in recess including providing and fixing pin 5/6 amps modular switch, connections etc. as required.
Supplying and fixing GI Modular box of (100mmx75mmx50mm) size with modular plate and cover in recess including providing and fixing pin 5/6 amps modular 2way switch, connections etc. as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1000 METAL BOARDS FOR SWITCH GEAR MOUNTINGS: Supplying and erection of following depth, sheet metal cubical pedestal of suitable' dimensions 'with plus-minus 5 cm variation, made from 1.6 mm thick. MS sheet duly fabricated in a segregated manner for housing of switch fuse units, by welding each compartment on five sides & front side hinged, complete with locking arrangement with sufficient. No vertical and horizontal intermediate switchgear housing compartments. The cubical pedestal shall have cable entry box at one or two sides with epoxy powder coated approved paint and bonding to the existing earth etc. The same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15cm high from ground level and 45cm thick. The cubical pedestal shall be 15cm from the top of cement concerete platform: 300 mm deep (nominal)
1300 SUPPLYING AND FIXING OF BUS BARS IN THE EXISTING CHAMBER / CUBICAL Copper Busbar - Supplying and fixing copper strip bus-bars suitable for 200A 415V capacity 4No. Each of cross-sectional area (25.4mm x 4.75mm), in each existing enclosure or cubical with all accessories including
1600 MOULDED CASE CIRCUIT BREAKERS AND AIR CIRCUIT BREAKERS: Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubical panel making connections, etc. as required
1700 MINIATURE CIRCUIT BREAKES / RESIDUAL CURRENT CIRCUIT BREAKERS: Supplying and erection of 6 amps to 32 amps rating, 10KA breaking capacity, 240V, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections
Single Pole Cat-A
Double Pole Cat-A (63A)
Supplying and fixing 20 amps, 240 volts, SPN moulded type, socket outlet, with 2 pole and earth, enclosed plug top along with 20 amps "C" curve, SP, MCB, in moulded enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and erection of 40/50/63 amps rating, 10KA breaking capacity, 240V, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections: Triple Pole & Neutral Cat-A (63A)
Supply and fixing 30A 415V TPN industrial socket outlet, 4-pole and earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 30A TPN-MCB on surface or in reecss, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required.
1800 MCB DISTRIBUTION BOARDS: Supplying and fixing of following way single pole and neutral sheet steel MCB dislribution board 240V on surface / recess complete with tinned copper bus. bar. wire-set, neutral link. earth bar, din-bar, detachable gland plate, cable. identification labels interconnections phosphatized and powder painted including earthing as required - Double Door-6 Way
Supplying and fixing of following way triple pole and neutral. sheet steel MCB dislribution board. 415V on surface / recess. with provision for 4 pole MCB/lsolator/RCCG/RCBO as incomer and sr MCBs as outgoing, complete with tinned copper bus. bar. wire-set, neutral link. earth bar, din-bar, detachable gland plate, cable. identification labels interconnections phosphatized and powder - Double Door-4 Way (8+12) horizontal
1900 EARTHING AND LOOP EARTHING
GI Electrode Earthing with 80 mm dia and 3 meter length, The electrode should be hot-dip galvanized with 120-150 micron. The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 50 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-friendly and having RoHs certification .GI Electrode Earthing should be maintenance free and dose not required regular manual addition of water. GI Electrode Shall be tested from CPRI.The earting pit should be cover with FRP cover, of 300 x 300 mm.
Supplying and fixing 25mm x 5mm copper strip on surface or in recess for earthing connection etc. as required
Supplying and fixing 25mm x 5mm GI strip on surface or in recess for earthing connection etc. as required
2000 LIGHTENING CONDUCTOR: Providing and fixing of Lightning conductor finial, made of 25mm dia 300mm long GI tube, having single prong at top, with 85mm dia 6mm thick GI base plate including hole etc. complete as required.
Riveting, sweating and soldering of copper / GI tape with another copper / GI tape base of the finial or any other metallic object as required.
Supply and fixing GI tap 20mmx3mm thick on parapet or surface of wall for lightening conductor as required (for vertical run)
Supply and fixing GI tap 20mmx3mm thick on parapet or surface of wall for lightening conductor as required (for horizontal run)
Supplying and laying of GI tape 32mmx6mm thick from earth electrode to directly in ground as required.
2100 UNCLASSIFIED ITEMS: Providing and fixinng MV danger notice plate of 200mm x 150mm made of mild steel at least 2mm thick and vitreous enameled white on both sides and with inscription in signal red color on front side as required
2200 ALUMINIUM CONDUCTOR PVC INSULATED ELECTRIC ARMOURED CABLES: Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured / XLPE power cable, working voltage 1100V grade on surface and ground of the required size.
Armoured Cable 6sqmm (twin core)
Armoured Cable 70sqmm (3.5 core)
Cu cable Armoured Cable 35 sqmm (3.5 core)
2500 PROVIDING AND INSTALLATION OF CEILING / EXHAUST FANS: Providing and installation of exhaust fan of following sizes in the existing opening, including' making the hole to suit the size of the above fan. making good the damages. connections. Testing and commisslonina etc as reauired: Exhaust fan, heavy duty 380mm sweep including suitable Louver
2700 SUPPLYING AND FIXING OF WALL BRACKETS / CEILING FITTINGS: Supplying and fixing of bulk head fitting of all sizes and shapes, containing one No. thread type CFL lamp holder(s), complete with all accessories but excluding CFL lamp including making connections. testing etc as required - Bulk Head Fitting, CFL type (Category - A)
2800 Supply and erection of Poles: Supplying and erection of street light bracket made of GI pipe 'A' class of suitable length and dia, the pipe bended to give an angle of 100 to 110 degree fitted with bolt and nuts at the top of existing pole or wall including painting the pipe with two coats of approved paint over prming coat complete in all respects as required: 40mm dia GI pipe heavy class
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of up to 150 sqmm size in the existing RCC/ HUME/ METAL pipe as required. (Laying of MV Cables)
CABLE TRAY AND RACE WAY: Supply, laying & fixing 14 SWG single compartment GI race way of following sizes along-with necessary cable support system as directed including fixing accessories like dash fasteners cable ties and junction box etc. complete in all respects including earthing of trunking with 4sqmm. PVC insulated wires including cutting chasing of floor and making of good (cutting of floor by machine).GI Race ways shall be minimum 20mm below floor finish as required as per approved drawings and directions of Project Manager
40x 300 x 40mm deep
50 x 225 x 50mm deep.
Supplying & installing following size of perforated pre-painted M.S cable trays with perforation not more than 17.5%, in convinient sections,joined with connectors, suspended from the ceiling with M.S suspenders including bolts & nuts, painting suspenders etc as required.
600 mm width x 62.5 mm depth x 2.0 mm thickness
450 mm width x 62.5 mm depth x 2.0 mm thickness
DISTRIBUTION BOARD & 3 PHASE METER & SUB MAIN DISTRIBUTION BOARD (SMDB): Supplying and fixing 12 Way TPN DB Double Door (Vertical) surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board double door of sheet steel, dust protected, duly powder painted, inclusive of 80 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s, with provision of 40A / 63A TP 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars ( with 6 MCB’s/ MCCB) as required.
S/I/T/C sheet steel inclosure for 32-63Amp TPN/DP/SPN MCB complete with all accessrories as required.
MULTIFUNCTION METER: S/I/T/C 3 Phase Multifunction Meter, L&T, 4410 LED, Class 0.5 with RS 485 along with 3 Nos. CTs of 100/5A Class-I and 3 phase indicator lamps, internal wiring with copper flexible wire, all connections, testing, commissioning and other petty material required to complete the job including labour charges or erection in existing cubical panels with cost of cutting the panel sheet and din bars etc.
LIGHTING FIXTURES: Supply, Carriage, erection, testing and commissioning of LED fitting. The lumen output of LED should be minimum 100 lumens per watt and should be type tested from NABL I UL accredited laboratory for LM79 & LM80 test reports and copy of same has to be submitted to the client department. The Fixture supplied with Electronic high efficiecy driver having Power factor >0.9, THD <10%. The sample of fitting shall be got tested in the presence of representative from NABL I UL accredited laboratory and the testing fee shall be borne by the contractor / supplier.
S/E of 40W LED Liner fitting surface mounted. made of extruded aluminium heat sink body provided for efficient heat dissipation & integrated electronic driver suitable for single phase A.C. 230V, 50 HZ supply, high efficent fixtures complete in all. The job includes cost of cutting the false ceiling to fix the fitting including giving support of chain from ceiling or frame and making connection to the nearest point with copper wires.
S/E of 40W LED Liner fitting surface mounted. made of extruded aluminium heat sink body provided for efficient heat dissipation & integrated electronic driver suitable for single phase A.C. 230V, 50 HZ supply, high efficent fixtures IP65 complete in all. The job includes cost of cutting the false ceiling to fix the fitting including giving support of chain from ceiling or frame and making connection to the nearest point with copper wires.
S/E of Surface Mounted LED 40 W Fitting Panel of size 4' foot long complete with driver. The fitting is to be fixed on ceiling with anchor fasteners.
12W LED round fitting recess mounted. The job includes cost of cutting the false ceiling to fix the fitting including making connection to the nearest point with copper wires.
S/I/T/C of LED street light light fitting of 70W / 72W rating with minimum 110 lumens per watt. The fitting is to be fixed on existing bracket mounted on Pole. The job includes cost of fitting, wiring connection etc. required to complete the job.
Supply ,Fixing, testing and commissioning of internal road light poles including the cost of providing top 70mm and bottom 130mm dia 3 mm thick 200x200x12mm MS base plate welded to the base of the pipe , Arm Length 1000mm and including digging and including the cost of masonry base pedestal built with 1:3:6 concrete (1 cement, 3 coarse sand and 6 graded stone aggregate 40 mm nominal size) provided with a 200 mm x 150 mm x 100 mm deep looping cable GI box recessed in the base pedestal / surface mounted fabricated from 14 SWG GI sheets with hinged gas kitted lockable door, terminal block for incoming and outgoing PVCA cables, 10 amps SP MCB, 2 Nos. suitable length 25mm dia GI pipe for incoming and outgoing cables and including the cost of painting, wiring, in pole from terminal block up to the light fittings with 2 x 2.5 sq.mm copper conductor 1100 volt grade PVC insulated wires along with loop earthling with 1 no. 8 SWG GI wire, earth stud etc. complete as required and as below. IS2713-PART II 6 mtr Long Swaged Pole. Planting depth shall be 600 mm. Height above ground shall be 5.4 metres including MCB & M.S. box etc. as required.
S/I/T/C of LED street light light fitting of 25W rating with minimum 110 lumens per watt. The fitting is to be fixed on existing bracket mounted on wall. The job includes cost of fitting, wiring connection etc. required to complete the job.
S/E of Self contained with 8W fluorescent tube for non maintained emergency lighting for 3 hours duration Complete as required.
S/E of 230/48Volts 440AH ,Battery charger with rectifier, DC Ammeter, DC Voltmeter and common DC bus for DC supply to battery.
ADDRESSABLE FIRE DETECTION & FIRE ALARM SYSTEM WITH PA: Supply, installation, testing and commissioning of Microprocessor based intelligent analogue addressable, modular, expandable networkable, following loop (each loop consist of Minimum 99 detector & 99 devices) fire alarm control panel with minimum 6 inch LCD display, multiple access levels, event history file in non-volatile memory (EEPROM). The panel shall have a built-in integrated voice command center with suitable rating amplifier for 25 Nos. of speakers. The panel shall support programmable relay for controlling lifts, staircase pressurizations fans, lift shaft & lift lobby pressurization fans, toilets exhaust fans, ventilation fans, monitoring of fire sprinkler and fire hydrant pump controlled by powerful Boolean logic equation. The panel shall have minimum five independent hazard release circuit built-in the panel. The panel shall have 240 volts AC power supply, automatic battery charger, 24 volts, sealed lead acid maintenance free batteries sufficient for 24 hours normal working and then be capable of operating the system for 4 hours during emergency condition i /c interfacing connectivity (BAC Net/modbus gateway) in Fire Panel for integrating with building management system complete as per Technical specification of tender . The panel shall be UL/FM listed. (UL 9th Edition Approved) (The panel shall be complete with suitable power supply to operate the as per detectors and devices in case of Emergency but not less than 10 Amp.)
Supplying, installing, testing and commissioning Automatic Floating Sensitivity type Analog addressable Accilimate Multisensor (Photo thermal) smoke cum heat detector with mounting based LED, address switch to programme the detectors complete as required.( It shall be UL/FM listed.)
Providing, installing, testing and commissioning of Repeater Panel for Fire Alarm System with piezo sounder, LCD alpha numeric character display with accept/reset buttons for alarm address of any sensor/field device. The Repeater Panel shall only provide field device address. Analogue output is not required. The Panel shall be connected to the Fire Alarm Panel
Supply, installation, testing and commissioning of Addressable type fault isolator for isolating shorted, dewired and loose circuits between two successive fault isolators with automatic resetting arrangement (base model)
Supply, installation, testing and commissioning of Addressable control relay modules for AHU & stairs Pressurization Fan.Hooter and manual call point etc.
Supply, installation, testing and commissioning of Hooter/Strobe Lights with 110 cd. The strobes shall be synchronized for better evacuation.
Supply and laying of 2 Core, 1.5 Sq. mm twisted pair copper conductor cable, low smoke zero halogen, high performance silicon rubber insulated, overall shielded, sheathed fire survival (HPSR) armored cable on surface/ recess/ existing couduit/ existing cable tray complete in all respect as per BS 6387 CWZ, EN50200, LPCB approved for the same size.
Supplying, installing, testing and commissioning of Analog Addressable air duct smoke detector with an efficient housing design and sampling tubes mounting based LED, Address Switch to programme the detectors, complete as required. (FOR AHU's).(It shall be UL/FM Listed)..
Supplying, installing, testing and commissioning of Response Indicator.
Supplying, installing, testing and commissioning Fire panel supervised 70db-84db Wall Mounted multi tap 12 Watt Speaker as specified & same make as of panel.
Supplying, installing, testing and commissioning 2 way communication Fire Fighter's Handset
Supplying, installing, testing and commissioning 2 way communication Fire Fighter's Telephone Jack as per specifications complete as required.
Supplying, installing, testing and commissioning Addressable Manual Pull Station complete as required.( It shall be UL/FM listed.)
NETWORKING AND VOICE SYSTEM: DATA PASSIVE COMPONENT
Supply, installation, testing and commissioning of 4 pair Category 6 UTP LSZH cable in existing conduit/ surface/recess/cabletray. Consisting of 24 AWG solid copper conductors complete with flexible jacket and ripcord for easy stripability etc complete as required as per specifications.
Supply, installation, testing and commissioning of category 6(E) flush mounted information outlets wired according to T568B standard with a faceplate.
Supply, Installation & Testing of Cat.6 E UTP 24-port Non-Shutter Patch Panel, Un-loaded with Layer II Managed Gigabit Ethernet switch: 8 port RJ45 10/100/1000 T (POE). INCLUDING SINGLE MODE SFP with transreceiver all network accessories like patch code , connectors etc for successful operations etc complete as required .
RJ 45 Connectors UTP with all accessories
Supply, Installation & Testing of 1U Cable Management Panel.
Supply, Installation & Testing of Cat6 Patch Cord UTP 2M CM, Blue for Field Side.
Supply, Installation & Testing of Cat6 Patch Cord UTP 4ft CM, Blue for Rack Side.
Supply, Installation & Testing of Cat6 Patch Cord UTP 7 ft , Blue for User Side.
Wi-Fi Access Point for Guest Floor and Admin
WAP Controller for above Aps
12 Port Ethernet Edge Switch 10/100 for Wi-Fi
Core Switch 10/100/1000 cum router for above Wireless Network
CLOSED RACK 12U: Rack 19'' 12 U 600W/800D( with front VNTD Glass Lockable Doors,Back Fully perforated Door, lockable and removable side panels, with 10 pin Vertical PDU
Castor ,Tyreman,FT brake & Back STD
Vertical Cable Manager
Fan HSG,90 CFM,4 FAN
Fan 230 VAC,90 CFM
NETWORKING AND VOICE SYSTEM:VOICE PASSIVE COMPONENT
Supply ,Installation &Testing of Cat.5 8-port Non-Shutter Patch Panel, Un-loaded Field.
Supply ,Installation &Testing of 1U Cable Management Panel.
Supply ,Installation &Testing of Cat.5, 8-port Non-Shutter Patch Panel, un-loaded Resource.
Supply ,Installation &Testing of Cat5 Patch Cord UTP 7 ft , Yellow for Rack Side.
Supply ,Installation &Testing of 20 Pair MDF Module Frame with lockable facility.
Supply ,Installation &Testing of 10 Pair disconnection Module for 100 pair MDF.
10 pair Telephone Riser Cable .
Supply & drawing of Cat.5 A 4Pair UTP Cable 305m Blue, CM for Back Bone.
Supply & Fixing of SOCKET RJ45 CAT5 Non-SHUTTERED KSTONE Grey for Back-Bone.
supply installation and testing of Rack 19'' 12 U 500W/300D lockable and removable side panels, with PDU.
CCTV SYSTEM:
Supply Installation testing commissioing of 540 TVL Day/Night Dome cameras with sensitivity of minimum 1.6 lux (Color) and 0.01 lux(B&W). The cameras shall use the1/3-inch interline transfer CCD sensor and shall have a 2.8 to 12mm varifocal lens. The Cameras shall be EN/UL Listed asper the specifications -(in P&G Area , Lift Lobby and admin office)
Supply Installation testing commissioing of 540 TVL CCD Camera with minimum lux level of 0.01 lux. The cameras shall use 2.9 to 8mm varifocal lens. Electronic Shutter range of 1/50 - 1 / 100,000 sec. The Cameras shall be EN/UL Listed asper the specification-(in Plant room and passage)
Supply Installation testing commissioing of 540 TVL CCD True Day/Night Camera with minimum lux level of 0.001 lux. The cameras shall use 2.7-13.5 mm varifocal lens. Electronic Shutter range of 1/50 - 1 / 100,000 sec. The Cameras shall be EN/UL Listed asper the specification.(External Perhaperi)
Outdoor Aluminium housing Small, Sleek, Contemporary Design High Reliability Die-Cast Construction Tamper-Proof Hardware, with Heater/Blower, Sun Shroud, Meets IP66 and NEMA Standards. UL,CE, FCC certified with Inbuilt power adapter for cameras asper the specification.
Supply, installation, testing & commissioning of UL listed DVR 16ch with 6Slots for HDD and DVD writer,Compression H.264,Outputs CVBS (BNC),HDMI, VGA ,4 audio input,Control RS 485 and RS 232,16 Alarm Input ,Video Output Loop Through,ESata connector for backup device,One front and one rear USB connector for mouse or USB memory device,Support Joystick Mode Manual, motion detection, scheduled, alarm,Alarm handling Motion detection Supports NAS
Supply, installation, testing and commissioning RG11 Cable in existing Conduit/raceway/cable tray with clamp/sadles/tie as per technical specification etc complete ar required .
Supplying and fixing of 25 mm steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
SITC of 42" LED 1920 x 1080 HD Display System
PLUMBING WORKS
SANITARY FIXTURES: All porcelain sanitary ware, CP fittings and accessories as specified below shall be supplied with complete accessories by the contractor at site as specified by Architect / Interior. The supply will be as made by the manufacturer / vendor as their standard supply. Contarctor will include providing and fixing of all other accessories, like silicon, extension pieces etc. fixing devices in the respective item rates for the same in his tender. No extra payment on this account will be admissible under any circumstances.
Providing , fixing, testing and commissioning of of white vitreous china European type water closet floor/ wall mounted with concealed P trap and low volume concealed type flushing cistern with internal fittings made of high grade plastic and non-corrosive metal, matching polypropelene seat and cover, CP brass hinges rubber buffers, with accessories, CI/MS concealed brackets painted with two or three coats of enamel paint of approved shade over a coat of primer. CP brass screws and wooden cleats, including cutting and making good the wall and floors wherever required.
Providing , fixing, testing and commissioning of C.P. hand spray (health faucet) with push button control and flexible hose connection with C.P. holder for hand spray complete in all respects.
Providing , fixing, testing and commissioning of CP brass Toilet Paper Holder fixed to PVC raw plug with SS screws, making holes in walls & making good.
Providing , fixing, testing and commissioning of Under/Over counter wash basin with C.I. brackets, 32 mm C.P brass/ PP waste fitting and C.P brass/ PP waterless Bottle trap - of standard pattern, including supply of CI Bracket fitting, flexible pipe with Supply of painting of fitting, cutting and making good the walls wherever required:
Providing , fixing, testing and commissioning of single lever pillar tap for wash basin.
Providing , fixing, testing and commissioning of senor pillar tap for wash basin.
Providing , fixing, testing and commissioning of white vitreous china Urinal basin of standard size C.P brass flush pipe, spreaders with unions and clamps (all in C.P brass) with waste fitting & waterless PP bottle trap (if required), with outlet grating, Infra-Red based electronic flushing system operated on 6V DC (4AA) battery for urinals comprising of solenoid valve, concealed built in strainer & flow mechanism piping, flush mounted sensors with all accessories & fittings complete in all respect in fully operational condition and other couplings in C.P brass including painting of fitting and cutting and making good the walls and floors wherever required.
Providing , fixing, testing and commissioning of of glass urinal partition as per interior drawing including providing & fixing concealed CI bracket, cutting and making good, complete in all respect.
Providing , fixing, testing and commissioning of Stainless steel AISI 304 (18/8) Pantry sink with CI/MS (Painted) bracket and stainless steel plug 40 mm including drain connection with PP 40/50 mm Dia pipe, painting of fittings and brackets, cutting and making good the walls wherever required:
Providing , fixing, testing and commissioning of of 15 mm CP brass wall mounting single hole mixing fitting for sink with swinging and swivel spout complete including cutting and making good the walls wherever required.
Providing , fixing, testing and commissioning of C.P brass Angular stop cock with wall flange (Angle Valve) for basin mixer,health faucet, Shower & WC etc. of approved quality complete in all respect.
Providing , fixing, testing and commissioning of SS finished Robe hook fixed to wall / door with wooden cleats and SS screws including cutting and making good the wall wherever required.
Providing , fixing, testing and commissioning of of SS liquid soap Dispenser with Metallic Bottle complete including cutting and making good the wall wherever required.
Providing , fixing, testing and commissioning of fully automatic "No tough" recessed SS brushed finish hand drier with paper dispencer and waste bin suitable to operate on 230 volts, single phase, 50 Hz AC power supply complete with brackets or required fixing arrangeements for fixing including cutting and making good the walls wherever required and connection.
Providing , fixing, testing and commissioning of adjustable support arm for physically challanged persons complete accessories complete as required including cutting and making good the wall and floor as required.
Providing , fixing, testing and commissioning of white colour Handrail for fix mounting 600mm long of for physically challanged persons complete accessories complete as required including cutting and making good the wall and floor as required.
INTERNAL DRAINAGE
Providing, fixing, and testing of uPVC SWR type B pipes and fittings, Push fit type, as per IS 13592 and fittings as per IS 14735 with factory fitted lip ring and complete as per specification and as required Vertical Soil, Waste, Vent/ASP Pipe fixing at wall / ceiling level supported by Painted M.S angle and G.I clamp with rubber line brackets & hangers etc. duly epoxy coated. cutting, chases / holes in floors / walls / slab.
75 mm dia
110mm Pipe dia
roviding, laying, jointing and testing uPVC pipes conforming to IS 4985 (6 kg/cm2) including injection moulded fittings with bosses e.g. tees, bends, couplings, adapters etc. and jointing with solvent weld joint, chasing, making wall good with cement and concrete complete as per specification and as required indirect waste Pipe.
40 mm dia.
50 mm dia.
Providing, fixing and testing of uPVC P or S trap having 50mm water seal, including jointing, making good the walls, floors etc., complete of nominal size - 110x110mm outlet
Providing, fixing, testing & commissioning of uPVC inlet fitting with maximum 3 inlets 40, 50 OD size, fixed to uPVC traps including solvent weld joint/rubber ring joint complete with all civil work.
Providing ,fixing, testing and commissioning of combination of 110 x 110 mm elbow and 110 x 50 mm eccentric reducer uPVC waste (as Floor Drain) with extension piece, elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to floor trap
Providing ,fixing, testing and commissioning of heavy duty SS grating of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for floor drain and floor trap: Size 100 mm x 100 mm
Providing and fixing in position square stainless steel cockroch trap consisting of 0.45 mm thick inner and outer cup and 1.0 mm thick top grating (Jali) with ring to be fixed inside ‘P’ traps with cement concrete. (for Floor Trap) - As per approved sample: Size 125 mm x 125 mm
Providing & fixing clean out plug with suitable openable fittings, male threaded joint with threaded socket fixed to pipe, joints as required complete in all respects : 110 mm dia
Supplying, fabrication and fixing of MS grating fabricated from 16mm square rod/ 20x4 mm MS flat having 20mm clear spacing, one piece upto 1000mm long, fixing angle iron frame 25x25x4 mm angle with hold fast at 1m c/c in cement concrete and hinged grating madeout of 35x5 mm flats in 1m length inclusiveof welding, griding etc. & including redprimer & two coats of enamel paint and setin cement mortar 1 : 3 (1 cement : 3 coarse sand) complete in all respect 350 mm wide.
Supply, installation, testing & commissioning of G.I. Pipes Class 'C' (Heavy grade) conforming to I.S. 1239 with G.I. Fittings conforming to IS : 1879 such as tees, crosses, plug, socket, elbows, reducers, flange, check nut, flanges & clamps, hanger, structural steel supports as required / directed at Site including cutting, making good the walls and painting with two or more coats of synthetic enamel paint of approved quality and shade over a coat of approved priming coat as directed by the Project Manager etc. (For Sump riser): 80 mm dia GI Pipe for Sump pump
Providing, laying, jointing and testing uPVC pipes conforming to IS 4985 (6 kg/cm2) including injection moulded fittings with bosses e.g. tees, bends, couplings, adapters etc. and jointing with solvent weld joint, C.I gratings over pipes of bell mouth construction with epoxy painting for terrace, fixing at wall / ceiling / floor level supported by clamp & hangers etc. inside duct / suspended from floor under false ceiling.The Pipes will be supported by either rubber lined G.I. U strap clamps on 50 x 50 x 5 mm MS slotted angle duly painted (for a group of pipes) or G.I. rubber lined split clamp (for independent pipes). The cost will include all support arrangements with any minor chasing / chopping / civil masonry work. commissioning of all pipes lines as per drawings and specifications and as directed by Project Manager at site.
75 mm dia
110 mm dia
160 mm dia
WATER SUPPLY (INTERNAL)
Providing, fixing, testing and commissioning of PP-r (Polypropylene Random) glass fibre compound 3 / 5 layer food grade pipe of PN – 16 in accordance with DIN EN 21003 for Domestic, Flushing & Hot water application with corresponding hot fusion welded, PR-r fittings like Tees, elbows, sockets, Reducers, Unions, brass wall adaptors (both male and female) etc. Cutting and making good the walls, floors, RCC work etc. cutting chase and filling the same with cement concrete 1:3:6 (1 Cement :3 Coarse sand : 6 graded stone aggregate 20 mm nominal size ) or cement Mortar (1 Cement : 4 Coarse sand) as required. . (Concealed Piping)
15 mm dia
20 mm dia
Providing, fixing, testing and commissioning of PP-r (Polypropylene Random) glass fibre compound 3 / 5 layer food grade pipe of PN – 16 in accordance with DIN EN 21003 for Domestic, Flushing & Hot water application with corresponding hot fusion welded, PR-r fittings like Tees, elbows, sockets, Reducers, Unions, brass wall adaptors (both male and female) etc. supported by clamp & hangers etc. inside duct / suspended from floor under false ceiling.The Pipes will be supported by either rubber lined G.I. U strap clamps on 50 x 50 x 5 mm MS slotted angle duly painted (for a group of pipes) or G.I. rubber lined split clamp (for independent pipes). The cost will include all support arrangements with any minor chasing / chopping / civil masonry work. commissioning of all pipes lines as per drawings and specifications and as directed by Project Manager at site.. (For Shaft and Terrace)
25 mm dia
32 mm dia
Providing, fixing, testing and commissioning of forged brass ball valve (PN 10) with hard chrome plated ball inside PTFE (Teflon) seat & ring with chrome plated centre handle withfemale BSP threads complete in all respects.
15 mm dia
20 mm dia
25 mm dia
32 mm dia
Providing, fixing, testing and commissioning of cast iron wafer type butterfly valves (PN 16) as per IS:13095, with SS disc, shaft, seating rings, internal fastening, nitrile rubber lining, nuts, bolts including transporting to worksite, 3 mm thick rubber gaskets etc. including testing, Complete as per drawings & directions of the Project Manager.: 50 mm dia
Providing, fixing, testing and commissioning of C.I. double acting air release valve of approved quality with bolts, nuts, rubber insertion, tail pieces, tapers, with ball valve etc. as required complete.: 25 mm dia
Providing ,fixing, testing and commissioning of IP 67 (Weather Proof /Aluminum casing with positioner to indicate the valve position with key type manual overdrive) Motorized Butterfly valve / Ball valve of following dia with limit switch arrangement for filling of over head water tank complete with high and low level float type sensors to control the valve .The sensors shall be installed in over head tanks. The sensors will close the valve when water level is high in over head tank and open the valve when over head water tank level is low. The system should be complete in all respects with control panel indicating the position of valve i.e. open /closed with pressure switches at pump discharge, accessories like wiring / conduting / flanges, nut bolts etc. All the control switchgears, connections, wiring, integration etc. should be included in the quote. No additional payment shall be charge for any work against this item.: 25 mm dia
WATER SUPPLY EXTERNAL
Providing,laying and jointing in position PE-80 HDPE pipe confirming to IS: 4984 and suitable working prssure of 12.5 bar and tested at 20 bar pressure with all fitting and accessories e.g - coupling, Tee, bends, reducer, flanged tail pieces etc jointing as per manufacturer specification/instruction. Cost shall inclusive of excavation upto required depth, filling sand alround, consolidation each deposited layer by ramming, watering etc, backfilling and disposing of surplus excavated soil as directed by Project Manager complete in all respect. (External Water Supply).
32 mm Dia
40 mm Dia
110 mm Dia
Providing and fixing truck fill point consisting of 100mm dia. Water filling point with butterfly valve and NRV having 100mm dia brass plug including suitable locable housing of approved design.
Supplying, fixing, jointing and testing in position the following heavy class (Class C) GI pipes conforming to IS:1239 cut to required lengths including all necessary fittings (All fittings shall confirm to IS:1879 - part 1 to 10) and specials such as bends, tees, unions, reducers, flanges & plugs etc including testing of pipes at twice of working pressure. Cost shall be inclusive of providing two coats of synthetic enamel paint of approved shade on exposed pipes, over a coat of red oxide , primer. Cost shall also inclusive of excavation upto required depth, filling sand alround, consolidation each deposited layer by ramming, watering etc, backfilling and disposing of surplus excavated soil as directed by Project Manager complete in all respect. ( For Garden Hydrant)
25 mm dia
50 mm dia
Providing and fixing ball valve (PN 10) with hard chrome plated ball inside PTFE (Teflon) seat & ring with chrome plated centre handle withfemale BSP threads complete:in all respects: 25mm dia nominal bore
Providing and fixing 20 mm brass QRQC hydrant valve with PVC lid complete in all respects.
Providing and fixing 20 mm brass keys for hydrant valve complete in all respects.
Providing, fixing, testing and commissioning of cast iron double waffer type flanged butterfly valves (PN 16) as per IS:13095, with SS disc, shaft, seating rings, internal fastening, nitrile rubber lining, nuts, bolts including transporting to worksite, 3 mm thick rubber gaskets etc. including testing, Complete as per drawings & directions of the Project Manager.
50 mm dia
100 mm dia
Constructing masonry chamber with 75 class designation bricks in cement mortar 1:5 (1 cement : 5 coarse sand) for ball valve with CI surface box 100 mm top dia 160 mm bottom dia and 180 mm deep (inside) with chained lid and RCC top slab 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1 : 5 : 10 mix (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 : 3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement and outside plaster finished rough complete as per standard design, including fixing of SFRC heavy duty Manhole cover and frame in 150 mm thick cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) including centering, shuttering, excavation, refilling and disposal of surplus earth as directed complete in all respects. (Include the cost of Manhole cover and frame): Inside size 450 x 450 mm & 600 mm deep
Providing & fixing digital type water meter with direct reading dial in KL with all internal parts in gunmetal or brass, butterfly valve, strainer, flanged distance piece for easy removal in future, Bourden type pressure guage and isolation cock including necessary test certificate for the meter from local municipal authorities.
25 mm dia for Domestic Water Supply Riser
50 mm dia for Municipal Inlet & Irrigation Water Supply
Providing, fixing, testing and commissioning of multistage, horizontal/vertical, centrifugal, 2 pole, 50 HZ, AC pumps incorporating C.I. casing and frame, stainless steel shaft, bronze / SS impeller, TEFC induction motor directly coupled to the pump, IP44 protection, class B insulated, C.I. body, hydraulically and dynamically balanced to give vibration free operation, with mechanical seal arrangement, fixed on a base plate with suitable vibration eliminator pads complete with level controller, electrical control panel / starter panel, necessary wiring / Cabling, pressure gauge, valves, vibration eliminators on the delivery side and strainer on suction side, including non-return valve and isolating valves on suction and delivering sides as required, including suction, delivery headers and interconnecting piping (G.I. Heavy Class) complete in all respects. -
Domestic Trasfer Pumps For Overhead Tank Filling; Flow rate (each) = 2.0 M3 /hr; Pumping Head = 45 m; 1 Set (2 Nos Pumps. 1 Working + 1 Standby); Location : Plumbing Plant Room
Making connection of Municipal water line with existing Muncipal line including excavation, construction of valve chamber & making good the walls, floors, road etc. Proper water proofing to ensure no. ground water seepage in the manhole: For 100 to 300mm dia pipe
EXTERNAL SEWAGE & DRAINAGE WORKS
Excavating trenches in all kind of soil of required width for pipes, cables etc including excavation for socket and dressing of sides ramming of bottoms depth upto 1.50 m including timbering, shuttering, centering etc. as required getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil within the site premises as specified by Project Manager: Pipes cables etc exceeding 80 mm dia but not exceeding 300 mm dia.
Extra for excavating trenches for pipes, cables etc. in all soils for depth exceeding 1.50 m but not exceeding 3.0 metre.(Rate is extra over corresponding basis item for depth upto 1.5 m)
Providing and laying non pressure NP2 class RCC pipes S & S jointed with stiff mixture of cement motrar in the proportion of 1 : 2 (1 cement : 2 fine sand) including testing of joints etc. complete
150 mm dia
200 mm dia
250 mm dia
Providing and laying cement concrete 1:5:10 (stone agg. 40 mm nominal size) in bedding & haunches of RCC pipes.
150 mm diameter RCC Pipe
200 mm diameter RCC Pipe
250 mm diameter RCC Pipe
Providing & fixing square-mouth uPVC gully trap complete with grating, brick masonry chamber with bricks of class designation 75 in cement mortar 1:5 (1 cement : 5 coarse sand) inside plaster above trap 12mm thick m cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement outside plaster 12mm thick in cement mortar 1 :3 ( 1 cement : 3 coarse sand) 10cm thick foundation concrete 1 : 5 : 10 mix (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) space between chamber, and trap filled with cement concrete 1:2:4 (1 cement : 2 coarses and : 4 graded stone aggregate 20 mm nominal size) and water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg asper standard design.
300 x 300 mm gully trap chamber with 150 x 100 mm 'P' trap with water tight C.I. cover with frame 300 x 300 mm size (inside) the weight of cover to be not less than 4.5 kg and frame to be not less than 2.7 kg as per standard design.
Constructing brick masonry road gully chamber 450 x 450 x 600 mm wtth bricks of class designation 75 in cement mortar 1:5 (1cement : 5 coarse sand), inside cement plastering 12mm thick with cement mortar1 : 3 (1 cement: 3 coarse-sand) finished witha floating coat of neat cement, outside plaster 12 mm thick in cement mortar 1 : 3 (1 cement : 3 coarse sand) 10 cm thick foundation concrete 1 : 5 : 10 mix (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) including 500x450 mm RCC horizontal grating wilh frame fixed in15cm thick cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 grade stone aggregate 20 mm nominal size) including excavation, refilling and disposal of surplus earth as directed by PMC complete as per standard design.
Extra depth for road gully chambers 450 x 450 rnm.
Constructing brick masonry rectangular type manhole with sewer bricks conforming to IS 4885 in cement mortar 1 : 5 (1 cement : 5 coarse sand) inside cement plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, outside plastering with cement mortar 1 : 3 (1 cement : 3 coarse sand) foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size). RCC top slab with 1 : 2 : 4 mix and making necessary channels in cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), inside finished with a floating coat ot neat cement including excavation, refilling and disposal of surplus earth as directed by Project Manager complete as per standard design.
600x600mm upto 800mm deep with ISI marked steel fiber reinforced concrete (SFRC) manhole cover and frame having hold fasts (Heavy Duty HD-20). 600 x 600 mm size.
900x800mm upto 1500mm deep with ISI marked steel fiber reinforced concrete (SFRC) manhole cover and frame having hold fasts (Heavy Duty HD-20) 560 mm internal diameter.
Extra depth for Rectanguler type manhole as per above item
600x600mm Size Manhole above 800mm dia
900x800mm Size Manhole above 1500mm dia
RAIN WATER HARVESTING SYSTEM
Rate shall include excavation, back filling and all other operations necessary for completing the job.
Providing and constructing Soak pit (2.0 Mtrs. Dia) with septik tank of size 3.0 m x 2.0m and eff. depth 2.0 m inside with 75 class designated brick work in cement motor 1:6 (1cement : 6 fine sand) with 3 Nos. 560mm dia C.I double seal medium duty manhole cover with top slab 1:2:4 mix (1cement : 2 course sand :4 graded stone aggregate 20mm nominal size) with minimum 1.5% reinforcement , foundation concrete 1:5:10 (1cement : 5 fine sand and 10 graded stone) aggregate 20mm nominal size including necessary excavation, back filling and disposal of surface earth complete with inlet, outlet, overflow arrangement pvc coated Foot Rest, 100mm C.I vent pipe -2m height with cowls.
FIRE FIGHTING WORKS
FIRE PUMPS, EQUIPMENT, PIPING, VALVES & ACCESSORIES : Electric Motor Driven Hydrant Pump (Location - Fire/Plumbing Plant Room) : Supplying, installing, testing and commissioning of Fire authority approved, factory assembled and tested Electrical driven fire pump suitable for automatic/ manual operation consisting of the following: Horizontal end suction, high pressure single/ multistage centrifugal type fire pump capable of delivering 1620 LPM (27 LPS) against a total head of 60 M while running at 2900 RPM complete with mechanical seal, proper connection to suction and delivery line, and including 100 mm bypass arrangement for testing of pumps, having a name plate indicating suction, delivery, head, discharge, stages, RPM and direction of rotation; Pump shall be capable of furnishing not less than 150% of rated capacity at a head not less than 65 % of rated head. The shut off head shall not exceed 120% of rated head; Squirrel cage, induction motor, TEFC type, efficiency class. eff-1, suitable for 415 + 10%V, 3 phase, 50 Hz, AC supply, of suitable HP rating for the above pump with a synchronous speed of 2900 RPM conforming to IP 55 protection & class 'F' insulation. The motor shall conform to IS 12615 : 2004 and IS 325 : 1978 (up to date) with flexible coupling and coupling guard; Common base plate for mounting pump and motor fabricated of mild steel channel as per manufacturer's recommendation with heavy duty Anti Vibration pads (6 Nos., heavy duty); Flexible Coupling and coupling guard for direct coupling of pump and motor; Drain Pipe with Valve (50 mm dia) (For independent testing respective pump); Main Fire Pump; Discharge : 1620 LPM (27 LPS) ; Pumping Head : 60 M; Motor KW (Approx) : 35 KW/As per manufacturer recommendation.
Rate should include interconnection fire survival cables and foundation bolts, grouting of Foundation bolts and other accessories required.
Diesel Engine Driven Fire Pump [Stand by pump] (Location -Fire/Plumbing Plant Room) : Supplying, installing, testing & commissioning of fire authority approved, factory assembled and tested Diesel Engine driven fire pump suitable for automatic/manual operations consisting of the following : Horizontal end suction, high pressure single centrifugal type fire pump capable of delivering 1620 LPM (27 LPS) against a total head of 60 M while running at 1500 RPM complete with mechanical seal, proper connection to suction and delivery line, and including 100 mm bypass arrangement for testing of pumps, having a name plate indicating suction a delivery head, discharge, stages, RPM and direction of rotation; Heat Exchanger cooled diesel engine of required BHP or as per manufacturer recommendation at 1500 RPM for the above pump complete with standard accessories & suitable cooling system as described in specifications; Common base plate for mounting pump & engine of required strength manufactured out of M.S. channels as per manufacture's recommendation with heavy duty Anti Vibration pads. (Cushy foot) (8 nos., heavy duty); Flexible Coupling & coupling guard for direct coupling of engine & pump; 1 No. minimum 8 hours capacity day oil storage tank fabricated from 3 mm thick M.S. plates. Tank shall be provided with inlet, outlet, overflow, air vent, drain connections, filling connection & magnetic level indicator. Tank shall be mounted on a suitable steel structure (Painted with 2 coats of red oxide paint). Tank shall be provided with epoxy coat from inside & two or more coats of synthetic enamel paint outside over two coats of red oxide primer. Diesel storage tank shall be double skin; 12 volts 180 AH lead acid battery (12 volts - 1 Nos) with boost/Trickle charger for starting the engine automatically complete as required; Diesel Engine driven pump of: Discharge : 1620 LPM (27 LPS) ; Pumping Head : 60 M; Engine HP (Approx) : 40 HP/ As per manufacturer recommendation; Jockey Pump :-
Rate should include inter connecting fire survival cables & foundation bolts, grouting of Foundation bolts and other accessories required. (Common for Hydrant & Sprinkler System)
Electrical Motor Driven Jockey Pump (Location - Fire/Plumbing Plant Room) : Supplying, installing, testing & commissioning of fire authority approved, factory assembled and tested electrically driven Jockey pump suitable for automatic/manual operation consisting of the following: Vertical multistage jockey pump having SS body S.S. impeller, stainless steel shaft with mechanical seal capable of delivering 180 LPM against total head of 60 M while running at 2900 RPM complete. The system shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side including bypass arrangement (with 50 mm GM stop valve and up to 5 meter G.I. class 'C' pipe) for testing of working of the pumping set as required. The pump should meet the recommended requirement and must be approved by the local fire authority; Squirrel cage induction motor suitable for 415 + 10%V, 3 phase, 50 Hz, AC supply of suitable HP rating for the above pump with asynchronous speed of 2900 RPM T.E.F.C type having effliciency class eff-1 as per IS 12615 : 2004, connected to pump with flexible coupling and coupling guard ; Common base plate for mounting pump and motor fabricated of mild steel channel as per manufacturer's recommendation with heavy duty 4 Nos. Anti Vibration pads.(Cushy foot); Drain pipe with valve (25 mm dia); Discharge : 180 LPM (3 LPS); Pumping Head : 60 M; App. HP/KW : 5.0 KW/ as per manufacturer recommendation
Rate shall include inter connecting fire survival cables, grouting of Foundation bolts and other accessories required.
Providing, fixing, testing and commissioning of precharged air vessel (size 450 mm dia & 1500 mm height) fabricated shell from 8 mm thick & dished end 10 mm thick M.S. Plate for pressurization of hydrant/ sprinkler system complete with adequate pressure switches (as per design / requirement) with valve to operate as per operating sequences including 25 mm dia drain valve, air release valve with ball cock on top, 80 mm dia flanged inlet with isolating valve duly painted from inside and out side complete as required.
Supply, installation, testing and commissioning of M.S Class 'C' (Heavy Duty) pipes conforming IS:1239/3589, with all necessary fittings like tees, coupling, mechanical tees, strap tees, elbows flanges, reducers, gaskets, nuts, and bolts etc. with welding joints as required including fixing the pipe with necessary structural supports including painting of two coats of synthetic enamel paint over two coats of red oxide primer including all civil breakage and making good the coats of red oxide primer including all civil breakages and making good the same. (Location: Fire Plant Room)
150 mm dia G.I. Pipe
200 mm dia (6 mm thick) with necessary supports etc. as required.
Providing, fixing, testing & commissioning of flanged end Y-strainer made from C.I body having SS filter mesh- 200 mm dia
Providing, fixing, testing & commissioning of C.I Butterfly valve conforming to IS : 13095 with flanges fittings, nuts, bolts and washers complete for following sizes :- [PN 10 rating (10 kg/cm2 pressure rating)].
200 mm dia
150 mm dia
100 mm dia
80 mm dia
50 mm dia
Providing, fixing, testing & commissioning of C.I dual plate non-return valve [PN 10Rating (10 kg/cm2 pressure rating)] complete with 2 nos. matching flanges, rubber insertion, with nuts, bolts and washers etc of following sizes .
150 mm dia
80 mm dia
50 mm dia
Providing & fixing dial type (100 mm dia) SS body pressure gauge with isolation ball valve suitable for working pressure of 150 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required. having calibration of 0-10 Kg/cm2.
Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45oC temperature, working pressure 10 Kg/cm2 and test pressure 15 Kg/cm2 for :-
150 mm dia
100 mm dia
80 mm dia
Providing, fixing, testing & commissioning of M.S. class 'C' diesel pump exhaust pipe (80mm) including all fittings like bends, tee, clamps/structural steel support of suitable dia for the engine . The insulation of the exhaust pipe shall be carried out with rock wool with specific gravity of 100kg/cm2 and cladded with 22 gauge aluminium sheet.
ELECTRICAL WORKS
Fire Fighing Panel described as above and as per SLD.
Supply, installation, testing & commissioning of following sizes of 1100 V grade XLPE insulated PVC inner & outer sheathed, Aluminium, fire survival armoured cables, as per site conditions.
3.5C x 120 Sq.mm
4C x 50 Sqmm
3C x 16 Sqmm
3C x 10 Sqmm
4C x 16 Sqmm
Copper Conductor Armoured fire survival Control Cables :
4C x 2.5 Sq.mm
5C x 2.5 Sq.mm
Cable Termination: Supply & making end termination with brass double compression glands for the following XLPE insulated, PVC sheathed & armoured 1100 V grade Aluminium cable including cost of crimping lugs/ferrules, compression glands, solder, cable sockets, insulation tape etc complete as required.
3.5C x 120 Sqmm
4C x 50 Sqmm
3C x 16 Sqmm
3C x 10 Sqmm
4C x 16 Sqmm
Cable Termination : Suitable for Copper Conductor Armoured Control Cables :
4C x 2.5 Sq.mm
5C x 2.5 Sq.mm
Supply and installation of GI ladder type/perforated type cable trays of the following sizes fabricated out of perforated hot dip galvanised MS sheets of minimum 2mm thick with 75mm flange to be installed horizontally or vertically: Ladder Type Cable Tray
300mm wide
150mm wide
Perforated Type Cable Tray
300mm wide x 50mm x 2mm
150mm wide x 40mm x 2mm
Earthing: Supply, Installation, Testing & Commissioning of the following size of GI strip/wire clamped to wall, cable trays complete as required including interconnection between lengths at joints, all fixing accessories saddles, calmps etc. and other fixing hardware.
50 x 6 mm strip
25 x 6 mm strip
25 x 3 mm strip
8 SWG GI wire
FIRE HYDRANT SYSTEM (INTERNAL) : SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF: 'C' class heavy duty M.S. pipe conforming to IS 1239 including welding/threading, jointing with all fittings like elbows, tees,bends,flanges, tappers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamps & structural steel support including cutting holes and chases in brick work and RCC work and painting with two coats of red oxide primer and two coats of synthetic enamel paint of required shade complete as required. Notes: Pipes upto and 50 mm dia shall be threaded joints, above 50 mm shall be done with Welded joints. Notes: Pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the wall/ floors/sealing, the sleeves with glass wool in between minimum 2 Hrs rated firestop sealant compound at either end, age tested to dafStb guidelines complete as per project manager's requirement or manufacturers reccomendation.
80 mm dia
100 mm dia
150 mm dia
Providing, fixing, testing & commissioning of ISI marked S.S. metal single headed fire hydrant landing valve with Inbuilt pressure reducing valve with flanged inlet, SS spindle controlled 63 mm dia female instantaneous outlet type. CI wheel, SS coupling, blank cap, chain, twist release type lug & all accessories. Conforming to IS:5290. (type A) Including fixing with anchor fastner and flanged tapping from wet riser and providing pressure gauge with gun metal ball valve complete as required.
Providing, fixing testing and commissioning of UL listed 63 mm dia 15 m long non-percolating flexible hose (RRL- type A) as per IS : 636. Type "A" with Stainless steel male & female instantaneous type coupling (IS 903) bound and riveted to hose pipe with copper rivets and 1.5 mm copper wire (For internal).
Providing, fixing testing and commissioning of Stainless steel branch pipe with nozzle of 20 mm nominal bore outlet as per IS:903 suitable to fit with standard instantaneous type 63mm dia coupling ISI marked (IS:903) complete.
Standard Fireman's Axe with heavy insulated handle.
Providing, fixing testing and commissioning of Wall mounting swinging type first aid fire hose reel with drum, hanging bracket, 30.0 Mtr. length x 20 mm dia thermoplast hose reel tubing as per IS:12585 with Stainless steel (SS) shut off nozzle having 6.5 mm dia orifice. The hose reel shall be conforming to IS : 884-1985. Rate shall include 25 mm dia M.S. pipe (heavy class) connection from Riser to hose reel, sockets, nipples, elbows and ball valve (25 mm dia). Drum shall be fixed on adjoining wall by means of 120 mm x 100 mm long fasteners, bolts and nuts including painting. (For internal hydrant system).
Providing & fixing fire authority approved M.S. hose door (size 900 (L) x 2100 (H)) made out of 16 SWG powder coated M.S. sheet Angle frame capable of accommodating fire hose reel, fire hydrant, hose pipe, fittings & accessories. The box shall have a single or double glazed front glass door (with 4 mm thick glass) with lock & key arrangement & shall be painted with Fire red as per IS:5, shade no. 536. (Location : For Internal Hydrant)
Providing, fixing, testing & commissioning of C.I Butterfly valve conforming to IS : 13095 with flanges/grooved fittings, nuts, bolts and washers complete for following sizes :- [PN 10 rating (10 kg/cm2 pressure rating)].
150 mm dia
100 mm dia
80 mm dia
Providing & fixing cast iron air release valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement.
Bourden type Stainless Steel dial type pressure gauge with brass isolation valve and pipe. (For each internal Fire hose cabinet) of dial diameter : 150 mm & Caliberation : 0-15 Kg/cm2
Providing and fixing M.S. structural work fabricated from standard sections, (MS rounds, angles, channels etc.) including cutting to size, drilling, welding, including cost of fasteners, clamps in RCC structural members as directed, including two or more coats of synthetic paint over one coat of primer after surface preparation including cutting and making good walls.
Air cushion tank (air-vessel) 250 mm dia. x 1.0 m high with dished top, made of minimum 6 mm thick MS pipe/plate complete with 25 mm dia. brass air valve (ball valve, pressure gauge type), 25 mm dia brass stop cock, nipple, tees, B46 elbow, pipe and all accessories as required incl. fixing brackets.
FIRE HYDRANT SYSTEM (EXTERNAL)
Supply, laying, testing & commissioning of 'C' class heavy duty M.S. pipe conforming to IS 1239 including grooved/threaded jointing with all fittings like elbows, tees,bends,flanges, tappers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamps & structural steel support including cutting holes and chases in brick work and RCC work and painting with two coats of red oxide primer and two coats of synthetic enamel paint of required shade complete as required. Notes: Pipes upto and 50 mm dia shall be threaded joints, above 50 mm shall be done with welded joints. Steel structural supports are included in this items. Pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the wall/ floors/sealing, the sleeves with glass wool in between minimum 2 Hrs rated firestop sealant compound at either end, age tested to dafStb guidelines complete as per project manager's requirement or manufacturers reccomendation.
80 mm dia
100 mm dia
150 mm dia
Providing and applying one coat of 4 mm thick anti rust pipe protection including approved primer as per manufactures specifications and lap of 25 mm to make an impermeable layer on M.S. Pipes in trenches or structural /masonary members complete including surface preparation.
80 mm dia
100 mm dia
150 mm dia
Providing, fixing, testing & commissioning of ISI marked S.S. metal single headed fire hydrant landing valve with Inbuilt pressure reducing valve with flanged inlet, SS spindle controlled 63 mm dia female instantaneous outlet type. CI wheel, SS coupling, blank cap, chain, twist release type lug & all accessories. Conforming to IS:5290. (type A) Including fixing with anchor fastner and flanged tapping from wet riser and providing pressure gauge with gun metal ball valve complete as required.
Providing, fixing testing and commissioning of UL listed 63 mm dia 15 m long non-percolating flexible hose (RRL- type A) as per IS : 636. Type "A" with Stainless steel male & female instantaneous type coupling (IS 903) bound and riveted to hose pipe with copper rivets and 1.5 mm copper wire.
Providing, fixing testing and commissioning of Standard Stainless steel branch pipe with nozzle of 20 mm nominal bore outlet as per IS:903 suitable to fit with standard instantaneous type 63mm dia coupling ISI marked (IS:903) complete.
Providing and plaacing of Stainless steel Standard Fireman's Axe with heavy insulated handle. Tested to 11 KV ISI marked.
Providing, fixing testing and commissioning of Weather proof standard fire hose cabinet (750 mm x 600 mm x 250 mm deep) for yard hydrants made of 16 SWG powder coated M.S. sheet having single or double opening glazed (4.0 mm thick glass) shutter including necessary locking arrangement by allan key, stove enamelled Fire red finish (as per IS : 5, shade no. 536) with " Fire Hose" marked on front, suitable for housing 2 nos. Hose pipe, 1 No. branch pipe & nozzle spanner. Cost shall inclusive of break glass box containing key for the cabinet along with axe hammer.
Providing, fixing, testing & commissioning of C.I Butterfly valve conforming to IS : 13095 with flanges/grooved fittings, nuts, bolts and washers complete for following sizes :- [PN 10 rating (10 kg/cm2 pressure rating)].
150 mm dia
100 mm dia
80 mm dia
Supply, installation, testing and commissioning of S.S four way fire brigade inlet to external hydrant ring /internal hydrant & sprinkler riser/Header with 63 mm dia instantaneous type inlet and 150 mm dia flanges outlet conforming to IS:904 with blank cap and chain including 150 mm dia C.I butterfly valve (PN 10 rating) and wafter type non-return valve complete with nuts, bolts, flanges and complete in all respect. Cost shall include a wall mounted box of M.S. construction (16 SWG) with glass door (4.0 mm thick) to house the above mentioned component.
S.S Metal Two way fire brigade suction hose coupling of (gunmetal draw out connection) with 100 mm dia M.S. 'C’ Class suction pipe with 100 mm dia C.I. foot valve (2 No.). (Pipe max. 10 m long). Cost shall include a wall mounted box of M.S. construction (16 SWG) with glass door (4.0 mm thick) to house the above mentioned component to be connected to static water tank.
S.S Metal fire brigade suction hose coupling of (gunmetal draw in connection) with 100 mm dia M.S. 'C’ Class pipe (Pipe max. 10 m long). Cost shall include a wall mounted box of M.S. construction (16 SWG) with glass door (4.0 mm thick) to house the above mentioned component to be connected at main fire header pipe in fire plant room and external ring main.)
Providing and laying light duty non pressure NP-3 Class RCC pipe S/S jointed with stiff mixture in the proportion 1:2, 300 mm dia R.C.C. Hume pipe for underground hydrant pipe at road crossings including collar pieces and filling inside of pipe with sand complete as required including necessary excavations and back filling and bed concrete. (For road crossing)
Bourden type Stainless Steel dial type pressure gauge with brass isolation valve and pipe. (For each External Fire hose cabinet + tarrace ); Dial Diameter : 150 mm; Caliberation : 0-25 Kg/cm2
Constructing brick masonry chamber with 75 class designation brick work in cement mortar 1:5 (1 cement :5 fine sand) for Butterfly valve/Sluice valve, with FRP medium duty manhole cover fixed in concrete slab 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size), necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand :10 graded stone aggregate 40 mm nominal size) and 12 mm thick inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement complete as per standard design - 1200 x 1200 x 1500 mm internal dimensions
Providing and fixing M.S. structural work fabricated from standard sections, (MS rounds, angles, channels etc.) including cutting to size, drilling, welding, including cost of fasteners, clamps in RCC structural members as directed, including two or more coats of synthetic paint over one coat of primer after surface preparation including cutting and making good walls (For structural work other than pipe supports).
SPRINKLER SYSTEM
Supply, laying, testing & commissioning of 'C' class heavy duty M.S. pipe conforming to IS 1239 including grooved/threading, jointing with all fittings like elbows, tees,bends,flanges, tappers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamps & structural steel support including cutting holes and chases in brick work and RCC work and painting with two coats of red oxide primer and two coats of synthetic enamel paint of required shade complete as required. Notes: For M.S. pipes upto and 50 dia shall be used forged fittings with threaded joint, above 50 mm shall be done with welded joint. Steel structural supports are included in this items. Pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the wall/ floors/sealing, the sleeves with glass wool in between and minimum 2 Hrs rated firestop sealant compound at either end, age tested to dafStb guidelines complete as per project manager's requirement or manufacturers reccomendation.
150 mm dia
100 mm dia
80mm dia
65mm dia
50mmdia
40mmdia
32mm dia
25mm dia
Providing, fixing, testing and commissioning of 100 mm dia Cast Iron/Ductile installation control valve assembly (test pressure should not be less than 10.0 Kg/Sq.cm) with flanges, nut, bolts & gasket complete with pad locking arrangement, vertical wet alarm valve with hydraulic alarm motor & gong, 2 nos. pressure gauges as per manufacturer recommendation with ball valves, 15 mm dia test valves, 50 mm dia drain valve with all necessary accessories.
Providing, fixing, testing and commissioning of 150 mm dia Bourden type, Stainless Steel dial type pressure gauges for sprinkler system including ball valve and pipe having caliberation of 0-10Kg/cm2.
Providing, fixing, testing and commissioning of Quick Response 15 mm dia quartzoid bulb type Stainless steel sprinkler head All sprinklers shall be chrome finish / powder coated except for conceled. The conceled sprinkler shall be brass finish. The cover plate of concealed sprinkler shall be factory painted at manufacturers work and the shade be conformed prior to application on the cover plate. The sprinkler shall be either pendent or upright type/side wall and shall not be universal style. Contractor shall ensure provision of sprinkler guard at no additional cost. All pendent sprinkler will be provided with rossette plate
Concealed Sprinkler 680C (K=80)
Upright / Pendent Sprinkler 680C (K=80)
Side wall Sprinkler 680C (K=80)
Supply, installation, testing & commissioning of UL listed/FM approved Sprinkler SS braided Flexible Joint of 25mm diameter, consisting of - Flexible Tube (SS 304), S.S. Slip nut, Isolated Ring & O Ring - for Sprinklers Drop, which shall include necessary supports with a maximum working pressure of 14kgf/cm2 and temperature rating of 225oF. The length of Flexible Sprinklers Pipe shall be:
Providing, fixing, testing & commissioning of C.I Butterfly valve conforming to IS : 13095 with flanges/grooved fittings, nuts, bolts and washers complete for following sizes :- [PN 10 rating kg/cm2 pressure rating)] of 100 mm dia
Providing & fixing cast iron single acting air valve with screwed inlet 25 mm dia including Ball valve and all fitting & accessories.
Providing & fixing water flow detectors / switches (Vane type) for sprinkler system, shall have sensitivity in the range of 4 to 10 US gallon per minute and static pressure rating of 450 PSI including accessories, junction box, suitable for indoor / outdoor mounting. The detector shall respond to water flow in the specified direction after a preset time delay that is field adjustable, complete as required suitable for fixing on fire pipe including connection for wiring. - on 100 mm dia line
Providing ,fixing , inspecting ,testing of 50 mm drain Size & 15 mm (5.6 K) Testing orifice drain assembly for installation on sprinkler system, in brass body consisting of steel singler lever ball valve for multiple test and drain functions, inculding inlet connection of specified size , sight glass , connections to the main header and line drain complete as per requirement . Product shall suitable for min.10 Kg/cm2 working pressure.
Providing and fixing M.S. structural work fabricated from standard sections, (MS rounds, angles, channels etc.) including cutting to size, drilling, welding, including cost of fasteners, clamps in RCC structural members as directed, including two or more coats of synthetic paint over one coat of primer after surface preparation including cutting and making good walls (Structural other than pipe support).
Supply and installation of 48 mm thick steel door shutter of 60 min fire rated confirming to BS-476, Part-22 and IS:3614part-II; abricated with 2 Nos. of 1mm thick galvanisedsteel sheet Size 1200 X 2380 MM S/L Sq. mtrs 8.568 with 202 grade SS ball bearing hinges (100x75x3 mm ) Assa Abloy, Fire rated door closer (standard arm) Assa Abloy, 60 min fire rated cleared wired glass (150X750X/7.3 MM), 202 grade SS back to backdoor handle (250 mm) Assa Abloy, Dead lock with 70 mm cylender Assa abloy complete in all respect to the satisfaction of Engiineer In-charge.sandwitching honeycombmaterial in between. Door frame are manufactured with 1.25 mm thick galvanised steel sheet pressed to formdouble rivet profileof size 143x60 mm. The frame and shutterare finished with powder coated.
Environment and Social Impact Management
Earth work( Temporary Worker shed & Creche, Dispensary)
CPWD SoR (Vol. 1) 2016 - Item No.2.8 Pg. 76: Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m. In all kinds of soil.
PCC- M10 ( Temporary Worker shed & Creche, Dispensary)
CPWD SoR (Vol. 1) 2016 - Item No. 4.19.1 (4.19.1.2) Pg. 91: Providing and laying in position reay mixed plain cement concrete, using fly ash and cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade of plain cement concrete, including pumping of RMC from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing including cost of curing,admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without imparing strength and durability as per direction of the Project Manager, sand and aggregate derived from natural sources. All works upto plinth level M-10 grade plain cement concrete (cement content considered @ 220kg/cum)
Brick work ( Temporary Worker shed & Creche, Dispensary)
CPWD SoR (Vol. 1) 2016 - Item No.6.3.1 Pg.111: Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS:2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement: 6 coarse sand) with FPS (non modular) bricks
Plastering (wall inside only) ( Temporary Worker shed & Creche, Dispensary)
CPWD SoR (Vol. 2) 2016 - Item No. 13.1 (13.1.2) Pg.227: 12 mm thick cement plaster of mix 1:6 (1 cement: 6 fine sand)
Flooring( Temporary Worker shed & Creche, Dispensary)
CPWD SoR (Vol. 2) 2016 - Item No. 11.3.1 Pg. 191: Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
GI sheeting Temporary Worker shed & Creche, Dispensary)
CPWD SoR (Vol. 1) 2016 - Item No 12.52.1 Pg.217: GI metal ceiling lay in plain Tegular edge global white color tiles of size 595x595 mm, and 0.5mm thick with 8mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyster powder coated of thickness 60 microns (minimum) including factory painted bending
MS angle ( Temporary Worker shed & Creche, Dispensary)
HPPWD SoR (Vol. 1) 2009 - Item No. 1502060000, pg. 1657: In trusses and trussed purlins in buildings of size 40x40x6
Steel plate (Sign boards)
HPPWD SoR (Vol. 1) 2009 - Item No. 024805030000, pg. 84: Galvanized structural steel plate 200mm wide 6 mm thick 24m long
Centering & Shuttering ( Temporary Worker shed & Creche, Dispensary)
CPWD SoR (Vol. 1) 2016 - Item No. 4.3 Pg.89: Centering and shuttering including strutting, propping etc and removal of formwork for foundations, footings, bases for columns
Doors ( Temporary Worker shed & Creche, Dispensary)
CPWD SoR (Vol. 1) 2016 - Item No. 7270 Pg. 36: 30 mm thick prelaminated flush door shutter
Windows ( Temporary Worker shed & Creche, Dispensary)
Earth fill( Temporary Worker shed & Creche, Dispensary)
CPWD SoR (Vol. 1) 2016 - Item No. 2.25 Pg. 79: Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
DPC ( Temporary Worker shed & Creche, Dispensary)
CPWD SoR (Vol. 1) 2016 -Item No. 4.11 Pg. 90: Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).
Dismantling brick masonry ( Temporary Worker shed & Creche, Dispensary)
CPWD SoR (Vol. 2) 2016 - Item No. 15.7 Pg. 253: Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge, in cement mortar
Dismantling doors and windows ( Temporary Worker shed & Creche, Dispensary)
CPWD SoR (Vol. 2) 2016 - Item No. 15.12.1 Pg. 254: Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead. Of area 3 sq. metres and below
(Sign boards)
CPWD- Delhi. Schedule Of Rates (Vol. 1) 2016 - Item No. 5.1.3 Pg. 97 Providing and laying in position specified grade of (RCC )reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work upto plinth level
Electrical items( Temporary Worker shed & Creche)
CPWD-DELHI (E & M) Pg-1 (1.1.1 Group-A- wiring) 2018. Wiring for light point/ fan point/ exhaust fan point/ call bell point / with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed steelconduit, with piano type switch, phenolic laminated sheet, suitable size MS box andearthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required
Providing & fixing LED bulbs 9W with approved quality and make including bulb holder.
Switch board with 5 AMP 3 pin sockets & switch control
Prefabricated Mobile Toilets (Water Supply for flushing ,Cleaning & maintenance will be in Contractor Scope)
Prefabricated Mobile Toilet( Economy 10 Seater Capacity, with sizes 5.50m x2.70m 3.0 height from Ground. Frame, Pillars, Ladders & railing make SS. Roof door panels are made of FRP. Unit fixed on wheels for easy movement at Sites as per requirement.
HAND APPLIANCES
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body,squeeze lever discharge valve fitted with internal discharge tube, 30cms long ISI marked high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5kg. I.S.I. Marked.
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body,squeeze lever discharge valve fitted with internal discharge tube, 30cms long ISI marked high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 9.0 Kg ISI Marked.
Providing and fixing ABC stored pressure dry chemical powder (monoammonium phosphate) Fire Extinguisher IS : 13849 latest revision manufacturer and of CRCA sheet in welded construction, finish with epoxy polyster powder coated complete with brass forged ball valve, gun metal cap and nozzel, including initial filled and wall suspension bracket (suitable for fighting in class 'A', B & 'C' that is wood, textile, flammable liquid, electric and gases - Capacity 6 kg
Providing and fixing carbon-di-oxide fire extingushers trolley mounted with all accessories internal discharge tube, high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.: Capacity 22.5 kg
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter "FIRE" in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets)
General sign boards as per IRC standards 2012 (Make and installation)
Safety siren/ alarm (at admin building)
UN- INTERRUPTED POWER SUPPLY
Supply, installation of 1 KVA UPS with 15 Minutes battery Backup at load using Sealed Lead Acid Maintenance Free batteries. Battery design life is 5-6 yrs.including with MS Racks for housing batteries, Battery Disconnector, battery to battery inter-links, Battery to UPS cable for a distance of 10 meters per UPS complet as required.
TPN ISOLATOR FOR GOODS LIFT
Supply, installation, testing and commissioning of Recessed 63A ,4Pole TPN isolator in powder coated, 1.6mm thick MS enclosure having facility for incoming and outgoing cables, set of ON/OFF/Trip indicating lamps shall be protected by control MCBs, complete with all materials and as per site requirement.
DISMANTLING & DEMOLITION
CIVIL WORK
Dismantling steel work upto span of 10 Metres and a height of 5 Metres in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, beadings etc. and stacking the materials within 20 Metres lead :
Extra over items No.1 for dismantling trusses, rafters, purlins etc. of steel work for every additional span of one Metre or part thereof beyond 10 Metres
Dismantling tiled floors laid in mortar upto floor two level including stacking of serviceable materials and disposal of un-serviceable materials within 20 Metres lead (wooden/concrete joists to be measured and paid for separately)
Demolition above G.L. upto floor two level including disposal of unserviceable materials within 20 Metres lead and including cutting the necessary reinforcement and separating out from R.C.C./R.B. works:-
Dismantling doors, windows and clerestory windows, ventilators etc. (wood or steel) shutters including chowkhats, architraves, hold fasts and other attachments etc. complete and stacking them within 20 Metres lead.
Dismantling roofing including ridges, hips, valleys, gutters etc. stacking the serviceable materials and disposal of un-serviceable materials within 20 Metres lead.G.I. Sheet roofing
Demolition of brick work above G.L. upto floor two level including stacking of serviceable materials and disposal of un-serviceable materials within 20 Metres lead
Demolition of stone masonry above G.L. upto floor two level including stacking of serviceable materials and disposal of un-serviceable materials within 20 Metres lead
Dismantling roofing including ridges, hips, valleys, gutters etc. stacking the serviceable materials and disposal of un-serviceable materials within 20 Metres lead.
ELECTRICAL WORKS
Dismantling of Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed Steel Conduit , with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required
Dismantling of Wiring for Piano type light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed Steel conduit along with 1No. 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Dismantling of Wiring for Piano power plug with 2x4 Sq. mm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed Steel Conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Dismantling of Wiring for circuit/sub-main with following size pve insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface / recessed Steel conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same Size for earthing as
2x1.5 Sq mm
2x2.5 Sq mm
Dismantling of Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke sirgle core (flexible) copper conductor cable in surface / recessed Steel conduit along with 2 No.10 Sq.mm. (4x10 + 2x10) HRFRLS/PVC insulated single core copper
Diamnatling of Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke sirgle core (flexible) copper conductor cable in surface / recessed steel conduit along with 2 No.16 Sq.mm. (4x16 + 2x16) HRFRLS/PVC insulated single core copper
Dismantling of above 32 upto100 A capacity TP&N Main disconnector fuse switch unit including with ISI marked HRC fuses , Mounted along with wooden Board etc. as required.
Dismantling of upto 125A capacity TP&N Main disconnector fuse switch unit including with ISI marked HRC fuses ,Mounted along with wooden Board etc. as required.
Diamantling of above 20mm up to 50 mm sizes of steel /PVC conduit along with accessories in surface/recess.
Dismantling of MS box of (100mmx75mmx50mm) size with Piano type Switch , phenolic laminated sheet,in recess including providing and fixing pin 5/6 amps socket, outlet and 5/6 amps Piano type switch connections etc. as required.
Dismantling of MS box of (100mmx75mmx50mm) size with Piano type Switch , phenolic laminated sheet,in recess including providing and fixing pin 5/6 amps socket, outlet and 5/6 amps Piano type switch connections etc. as required.
Dimantling of ceiling rose on the existing junction box / wooden block including connections etc. as required.
Dismantling of bakelite batten/angle holder including connections etc as required:
Dismantling of pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable including with existing surface/ recessed steel conduit .
Dismantling of earth connection from earth electrode with 6SWG GI wire in 15mm dia GI pipe from earth electrode to Main Fuse Unit Board etc. as required.
Earthing with G.I. earth plate 600 mmx600 mmx 6mm thick, including accessories and providing masonry enclosure with cover plate having' locking .arrangement and watering pipe etc. (but without charcoal or coak and salt) complete as required
Dismantling of following piano type switch/ socket on the existing switch box/ cover including connections etc. as required
Telephone
Bell Push
Dismantling of fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated,
Dismantling of Above 6qmm and upto 25 Sqmm (3.5C) aluminium or copper conductor, PVC insulated and PVC sheathed, armoured / XLPE power cable, working voltage 1100V grade on surface including Lug & Glands etc.
Dismantling of exhaust fan upto 450mm dia sizes including with Connection and 900 mm Ceiling fan.
Dismantling of 3 Phase Meter along with 3 Nos.Suitable CT and 3 phase indicator lamps, internal wiring with copper flexible wire, all connections in inside the Wooden Board and cover with MS BOX as etc.
Dismantling of 1Nos Run UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel conduit as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required
Note: Prices quoted shall be inclusive of GST, transportation, insurance, loading/ unloading, shifting, labour charges etc. Nothing extra will be acceptable above the quoted rates.
Sai Ba Engineers
P K Construction Shimla Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .