| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.3 L+₹2.2 L (8.72%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹28.7 L+₹3.7 L (14.6%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹31.0 L+₹5.9 L (23.6%)Rejected-Finance A 103 VEERA GARDEN AMBEDKAR NAGAR ALWAR 301001 RAJ | ALWAR | RAJASTHAN | 301001 | L4 | Rejected-Finance Being L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical No remarks against firm in WLR |
Tender Value
Refer Docs
EMD Value
₹59,500
Closing Date
27 Oct 2022, 6:00 pmClosed
GE Alwar
GE Alwar
SPECIAL REPAIR TO CONVERSION OF LT OH LINE TO LT UG CABLE AND CONNECTED SERVICE AND PROVN OF DESERT COOLERS UNDER AGE E/M AT ITARANA, ALWAR
2022_MES_554947_1
8100/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Alwar
As per NIT
3 documents required · 3 mandatory
₹500
Yes
GE Alwar
₹59,500
Yes
2 Dec 2022
28 Sept 2022
29 Oct 2022
28 Sept 2022
27 Oct 2022
13 Oct 2022
28 Sept 2022 - 12 Oct 2022
Amount
Dismantling and taking down old unserserviceable ACSR Conductor and GI wire of any size from LT Poles and removing from site complete all as specified and directed.
Dismantling and taking down old unserserviceable GI earth wire/guard wire etc of any size from LT Poles and removing from site complete all as specified and directed.
Dismantling and taking down of old unserviceable insulators any type, any size and make from cross arms / poles complete all as specified and directed.
Taking down old unserviceable cross arms/clamps/nut bolts and angle section etc from LT pole any size complete all as specified and directed.
Dismantling and taking down old unserserviceable stay assembly from LT poles and removing from site complete all as directed.
Dismantling and taking down of old unserviceable prestressed cement concrete LT pole complete all as directed.
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for complete all as specified.
M&L for PCC 1:3:6, type C1 using 20mm graded crushed stone aggregate as in coping/pedestal of poles including providing necessary form work for fair finished exposed concrete surfaces complete all as specified and as directed.
M&L for PCC 1:3:6, type C2 using 40mm graded crushed stone aggregate as in foundation of stay assembly & poles and similar works complete all as specified. Note :- Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment.
Supply, laying, jointing, testing and commissioning XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 150 Sqmm 3.5 Core laid in trenches/ducts, through pipe, under floors or roads/along poles etc complete all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
All as per item No 10.00 but size 120 Sqmm 3.5 Core.
All as per item No 10.00 but size 95 Sqmm 3.5 Core.
All as per item No 10.00 but size 50 Sqmm 3.5 Core.
All as per item No 10.00 but size 35 Sqmm 3.5 Core.
All as per item No 10.00 but size 25 Sqmm 4 Core.
All as per item No 10.00 but size 25 Sqmm 2 Core.
All as per item No 10.00 but size 16 Sqmm 2 Core.
All as per item No 10.00 but size 10 Sqmm 2 Core.
Excavation in trenches n. exc 1.5 Mtr width n.exc 1.5 Mtr in depth for laying of cables & foundation of poles, stay assembly and getting out soft/loose soil.
Excavation in trenches, not exc 1.5 m wide and exc 1.5 m depth and n. exc 3.0m depth & getting out soft/loose soil, for laying of cables, foundations of poles, struts, stays etc and getting out including trimming and forming bottom surface complete all as specified and directed.
M&L for sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed. Note :- Thickness after punning shall be considered for payment.
M&L for brick work with FLY ASH BRICKS(As Per IS-13757(1993) burnt clay fly ash building bricks), (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection and complete all as specified & directed.
Returning, filling in including spreading levelling , watering and well ramming in layers not exc. 25 cm in any type soil.
Removing of surplus excavated soil to a distance not exc 50m and depositing where directed at a levelnot exc 1.5 Mtr above the starting point.
M&L for trenchless boring in any strata of soil across road, pavement, hardstanding etc by using modern ultra sound technology upto a depth as directed but not less than 0.60 mtr below GL/ road, pavement, hardstanding etc level for laying of LT cable under road, pavement, hardstanding etc without damaging existing under ground materials including provision of HDPE pipe of 80mm dia of 0.4mpa working pressure complete all as directed.
M&L galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron 25mm x 3mm clamps, bolts, nuts and washers for protection of LT electric cable including taking down old unserviceable GI tube complete.
M&L galvanized iron tubing 50mm bore medium grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron 25mm x 3mm clamps, bolts, nuts and washers for protection of LT electric cable including taking down old unserviceable GI tube complete.
M&L galvanized iron tubing 80mm bore medium grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron 25mm x 3mm clamps, bolts, nuts and washers for protection of LT electric cable including taking down old unserviceable GI tube complete.
Supply & errecting cable path indicators for LT Cable made of CI plate fixed on MS angle iron size 25 x 25 x 5mm and 60 Cm long. and fixing in ground 30 Cm below ground level in PCC 1:3:6 type B-1 using 40mm grade stone aggregate of size 30 x 30 x 30cm. Cable path indicators shall be provided at distance of every 30 meters and at cable joints and turning of all cables and incorporated LT 1100 Volts on it including PCC & earth work complete all as specified and directed.
Supplying, transporting to site errecting and fixing in position steel tubular swaged pole, 11 metre long, type 410 SP-55, complete with cast iron base plate, pole cap, finial taper plug, bolts, nuts, washers etc including painting with two coats of aluminium paint over one coat of red oxide primer including 3 nos band/straps in yelow and black colour (300mm wide EACH) using synthetic enamelled paint commencing at a distance 300mm from padestal of pole and marking pole nos with black synthetic enamelled paint including tarring one coat on steel surface embedded in concrete including taking down old unserviceable PCC pole complete all as specified and directed. Note:- Excavation and earth work, PCC etc shall be measured and paid separately under respective items.
Fixing only retrived machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15650-2008 of 60mm thickness, M-35 grade with grey cement and no pigment except tiles, including taking down and 25cm thick sand cushioning complete all as specified and directed. Note:-Sand cushion will be measured and paid separately.
Supply, installing, testing and commissioning factory made, floor mounted outdoor type LT panel board, cubicle type, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, and tested at CPRI having bus bar chamber with insulated Aluminium bus bar four wire system, colour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands. The panel shall be dust and vermin proof, IP-65 class protection and made 3.2mm, CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) including grouting of panel 45 cm above ground level by providing 90 cm long angle iron frame of size 50 x 50 x 6mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm above ground level complete all as specified and directed including the following accessories :- Incoming (i) Aluminium bus bar 200 Amps with insulator - 04 Nos (ii) Instrument control fuses and indication lamp(RYB) - One set Outgoing (i) MCB TP 63 Amps 10 KA, 'C' Curve -03 Nos + Space for one No MCB - SP/SPN/TP.
All as per Item No 32.00 but the following accessories:- Incoming (i) Aluminium bus bar 200 Amps with insulator-04 Nos (ii) Instrument control fuses and indication lamp(RYB) - one set Outgoing (i) Thermal magnetic MCCB 3 pole,100 Amps 25 KA -01 No (ii) MCB TP, 63 Amps 10 KA, 'C' Curve -03 Nos + Space for one No MCB - SP/SPN/TP
All as per Item No 32.00 but the following accessories:- Incoming (i) Aluminium bus bar 200 Amps with insulator - 04 Nos (ii) Instrument control fuses and indication lamp(RYB) - One set Outgoing (i) Thermal magnetic MCCB 3 pole,125 Amps 25 KA - 01 No. (ii) Thermal magnetic MCCB 3 pole,63 Amps 25 KA - 01 No.
All as per Item No 32.00 but the following accessories:- Incoming (i) Aluminium bus bar 200 Amps with insulator - 04 Nos (ii) Instrument control fuses and indication lamp(RYB) - One set Outgoing (i) Thermal magnetic MCCB 3 pole,63 Amps 25 KA - 01 No
All as per Item No 32.00 but the following accessories:- Incoming (i) Aluminium bus bar 200 Amps with insulator - 04 Nos (ii) Instrument control fuses and indication lamp (RYB) - one set Outgoing (i) MCB TP, 63 Amps 10 KA, 'C' Curve -05 Nos + Space for one No MCB - SP/SPN/TP
Supply, installing, testing and commissioning, factory made and tested Bus bar chamber outdoor type of size 60 x 45 x 45cm, made out of 3.15mm thick CRCA MS sheet and 50mmx50mmx8mm thick angle iron frame work, IP-65 class protection, powder coated finish over one coat of red oxide primer front & rear openable type, with locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys for each side opening} consisting of 04 Nos insulated copper bus bars 200 Amps rating on porcelain insulators. Bus bar chambers shall be mounted/fixed in ground/floor using 04 Nos angle iron of size 50mmx 50mm x 8mm welded/fixed to Bus bar chamber of height as directed including making post holes in ground and embedding angle iron in PCC 1:2:4 type B-1 complete all as specified and as directed. The Bus bar chamber shall following :-(a) MCCB 100 Amps four pole rupturing capacity 25 KA., 415 V AC , 50 Hz confirming to IEC 60947-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In adjustable short circuit setting 6 – 10 x In - 01 No. (b) Indicating lamps-01 set of three Notes (a) All armoured cables shall enter through bottom of the feeder pillar duly glanded and socketed. (b) All the out going cable shall also be glanded and socketed. (c) Cost of glanding/socketing etc are deemed to be included in the unit rate of Bus bar chamber.
Supply, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT feeder pillar box (KIOSK) of appropriate dimensions (as per Indian Electricity rules) to accommodate following components, outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated Aluminium bus bars 1000 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 50x50x8mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front & rear opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring with PVC insulated, multistranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. The scope of work includes the following :- INCOMING (a) Aluminium bus bar of rating 500 Amps for four pole including PVC heat shrink sleeves (RYB & N ) : 01 Set. (b) MCCB four pole 160 Amp confirming to IEC 60947-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 36 KA at 415 V AC , 50 Hz complete - 01 No. OUTGOING (a) MCCB four pole 100 Amp confirming to IEC 60947-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete - 04 Nos. (b) MCCB four pole 63 Amp confirming to IEC 60947-2 & IS – 13947-3 fixed type and rupturing capacity 16 KA at 415 V AC , 50 Hz complete - 01 Nos. (c ) MCCB four pole 40 Amp confirming to IEC 60947-2 & IS – 13947-3 fixed type and rupturing capacity 16 KA at 415 V AC , 50 Hz complete - 02 Nos. Control System (a) Amp meter (0-400A) analog type 96mm Square dial –01 No. (b) Volt meter (0-500V) analog type 96mm Square dial – 01 No (c) Three way rotary switch for volt meter/ammeter – 02 Nos (d) CT of ratio 400/5 – 01 Set of Three (e) Indication lamps R,Y,B ( LED type) with toggle switch - 01 Set. Notes (a) All armoured cables shall enter through bottom of the feeder pillar duly glanded and socketed and connected to MCCB/cable terminal. Cost of glanding socketing etc are deemed to be included in the unit rate of feeder pillar. (b) All the out going cable shall be terminated in bakellite cable connector and shall be duly glanded and socketed. (c) All the cables (power and control wiring ) should be terminated duly socketed with heavy duty tinned copper lugs, GI bolts/screws nuts, flat washers and spring washers as required. (d) White acrylic marker plate (for feeder / switch marking ) to be provided with black lettering by heat press machine as indicated in drawing and to be pasted over the panel door/near the cable connector with high quality adhesive. (e) The cost of platform/foundation with PCC shall deemed to be included in the quoted rates.
S&F for pole mounted juction box made out of one piece moulded SMC IP65 protection having aluminium bus bars 100 Amp single phase and neutral with one No MCB SPN 6 Amp for street light, cable entry from bottom, maintenance free size 300mm x 200mm x 100mm fixing on pole with MS flat 25mm x 3mm clamp including nut bolts front openable all as specified and directed.
S&F of PVC insulated and round sheathed copper conductor cable 2.5 sqmm 3 core through and including steel conduit 15mm dia from street light fitting to junction box and making necessary connection both at junction box and street light fittings and fixing accessories i.e required size of flat iron 25mm x 3mm clamps, bolts, nuts etc. complete all as directed. Make of cables : Havells/Finolex /Polycab Make of steel conduit : Jindal/Prakash/Prayag.
M&L for earthing complete as per electric plate No 3 of MES SSR Part-I with galvanised steel earth plate electrode 60 x 60 cm x 6.3mm thick burried directly in ground (earth pit not less thanb 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised strip 25 x 4 mm earth lead by means of bolts, nuts, check nuts and wathers of GI or steel . Earthing strip shall be protected by galvanised iron pipe 40 mm bore light grade and connected to continous earth lead on pole/test point, watering pipe shall be 20 mm bore GI medium grade. The unit rate quoted for earthing shall be inclusive of excavation and earth work in any type of soil, charcoal, salt, funnel, PCC pit and RCC cover complete all as specified and directed.
M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 32/6mm earth strip by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part I and connection to main switch board or panel and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, PCC chamber (1:3:6) type C-2, charcoal and salt mixed layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, 75 mm thick RCC cover 1:2:4 type B-1 shall be provided on CI frame etc complete all as specified & as directed. Note : PCC chamber shall be constructed at least 1.5 m away from the earth electrode. The pipe for watering shall be provided in slanting manner.
Supply only desert cooler in steel body with propeller type cooler fan with motor (ISI Marked) three speed 1440 RPM, 1/8 HP Copper winding, 230V, 50HZ, sealed double ball bearing, vacuum impregnated stator winding, One Year Warranty, silent operation, nominal capacity 4000 cum/hr, fan size 450mm, type of blade metallic (HIP), submersible water pump, filter pad, electric driven, single phase, 230 volts, 50 Hz, capacitor 4 mfd, suitable plug top 5/15Amp as reqd including all accessories complete all as specified & directed by Engr-in-Charge. Make : Bajaj/ Khaitan /Maharaja. Note :- (i) Filter panels,front grill and top of the cooler body shall be made of 1mm galvanized steel sheet. The sump tank and rest of the body shall be made of 1.20mm thick galvanized steel sheet. The galvanised steel sheet shall be ISI marked and shall have zinc coating not less than 100 gms/sqm and shall conform to IS : 277. (ii) All internal surface including inside of the tank, fan blades, motor body, pump, pump body shall be painted with water resistant paint conforming to IS: 986. The outer surface of the cooler shall be spary painted with synthetic enamel paint of approved shade/tint. (iii) The desert cooler shall be fitted with adjustable grill with separate on/off switch of 5/6 Amp rating (ISI Marked) for cooler fan and water pump and three stage speed regulator (Low, Medium, High) for three speed cooler fan motor. (iv) Suitable nylon bushes shall be provided in the grill for easy and smooth movement of louvers. (v) The filter pads shall be contain wood wool.The filters pads shall be fixed over the panel and seured by clamping guard of galvanized wire of 2mm dia (approx) squre/rectangular.The wire guard shall be fixed in the clamps to avoid any sagging.
M/S GAURI CONSTRUCTION
Shiv Enterprises
Hitesh Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .