| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC VILLAGE KHARI KALAN PO CHOLANG DISTT JALANDHAR | JALANDHAR | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.0 L+₹996 (0.03%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹30.3 L
EMD Value
₹60,590
Closing Date
7 Jan 2021, 11:00 amClosed
Er. Nitin Kalia
Executive Engineer Water Supply and Sanitation Division no2 Jalandhar
Providing and Installing straight tubewell Construction of Pump Chamber Below OHSR TANK Constructing 1 No. OHSR of 15000 Ltrs Distribution System and Civil Work Etc.
2020_WB_56976_1
DWSS-W-DIV14-8886-1
Open Tender
Civil Works - Water Works
Item Rate
270 days
Jalandhar
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
₹60,590
24 Feb 2021
3 Dec 2020
7 Jan 2021
3 Dec 2020
7 Jan 2021
3 Dec 2020
Amount
TUBEWELL (HAND BORING MACHINE) Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested , equipment as required such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect.
Boring with 200mm id Housing pipe upto 100m depth BGL
Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
150mm nominal diameter (weight 21.6 kg per meter) 5.4 mm thickness.
Supplying, fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked, duly welded with suitable grade S.S. welding electrode to lower the strainer into tubewell bore.
150mm steel strainer (slot size 0.20mm) 5.00 mm thickness.
Supplying, fixing and lowering of stainless steel socket as per IS 8110-2000 or latest, ISI marked duly welded with suitable grade ss welding electrode to lower the strainer into tubewell bore complete in all respect.
150mm Internal diameter
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect.
150mm internal diameter
Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
Supplying at site Wooden Box of suitable size with Lid & locking arrangement for preserving strata sample collected from the bore.
Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attached to the bottom plug complete in all respect.
150mm internal diameter (weight 21.6 kg per meter) 5.4 mm thickness.
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect.
150mm internal diameter.
Development and Stabilizing of the tubwell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Capacity of Air compressor 300 cfm at 250 PSI.
Development and Stabilizing of the tubwell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Collection of water sample from different strata and testing of sample from approved laboratory (Phisical & chemical Analysis)
Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.)
Sterilization of T/W (NS)
OHSR OHSR Constructing one No. of 15 KL (15000 liters) Capacity with sill level not less than13.00m height upto FSL 15.50 mtr from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing CI D/F expansion joints conforming to (IS-1536-1989) or latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, Conforming to ISI - 13382 and CI D/F sluice Valve duly ISI marked (IS-14846/2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow CI double flanged pressure pipes horizontally as per IS 7181/1986 and latest duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminium leader inside the OHSR complete in all respect as per specifications. (The specifications & drawing are based on safe bearing capacity of soil of is less than 8.75 tone per sqm. In case the safe bearing capacity of sail is less than 8.75 tone per Sqm. The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Preminum including overflow haudi complete in all respects. Including cost :- Supplying, fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects. including: Construction of plinth protection around OHSR with with in 40mm thick CC 1:2:4 on top over 100mm thick C.C 1:8:16 masonry toe wall & inside earth filling complete in all respect
PUMP CHAMBER BELOW OHSR Construction of Pump Chamber Below OHSR TANK size 2.20x2.20m Without gravel pit but including electric wiring as per analysis, complete in all respects.
Chlorinator plant Prov. & Fixing Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Liters of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS standard specifications.
Rising Main Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with Prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications. for more than 3 mtr. Street width Complete in all respect. (Mechanically ) Excavation including specials (10kgf/ cm2) Pressure
90 mm o/d P.V.C. pipe
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). Class PN-1 as per ISI
80mm i/d sluice Valves Flanged. (Note:- 1 no. for Pumping Main & 4 nos. for Distribution System)
Construction of masonry Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.6 m. x 0.6 m. (Note:- 1 no. for Pumping Main & 4 nos. for Distribution System)
Distribution System Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with the prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications. For less than 3 mtr. Street width Complete in all respect. specifications for Manually Excavation including specials (6kgf/ cm2 Pressure)
PVC pipe 63mm o/d PVC 6 kg/cm2
Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with the prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications. For more than 3 mtr. Street width Complete in all respect. (Mechanically including specials (6kgf/ cm2 Pressure)
PVC pipe 63mm o/d PVC 6 kg/cm2
PVC pipe 90mm o/d PVC 6 kg/cm2
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting and including restoration of roads to original Position.
90mm PVC Pipe
Dismantling of cement concrete 80mm thick cement concrete 1:2:4 over 100mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respects
PVC pipe
Interlocking Tile Dismantling of Interlocking Tile 80mm thick cement concrete interlocking paver block complete in all respect
Re-fixing of Interlocking Tile 80mm thick cement concrete interlocking paver block of M-40 grade Machine made rubber moulded smooth finish by strong vibratory process or with vibro-hydraulic compaction machine and of approved size and design/ shape laid in ordinary Grey Colour and pattern over and including 40mm thick complete in all respect.
Contractor shall quote rates only for dismantling of metalled road and back filling with excavated earth, fully compacted. The restoration of the metalled road to its original condition will be done by the concerned department I.e PWD (B&R)/PMB/ Panchayti Raj.
PVC pipe
Restoration of the Metalled to its original condition Bituminous course 50 to 75 mm thick C.C 1:8:16: and Making good the same to its original condition complete all respect as per analysis A-25 (will be done by concerned Department.
PVC pipe
Water Connection with Water Meter Providing proposed water connection with multiject water meter to house hold upto wall with providing laying jointing tasting G.I Pipeline 15mm i/d 2.5 mtr. (B-Class) Above G.L) Providing & Fixing MDPE pipe 15mm i/d with specials 2.00 mtr. (Below GL) including cost of specials such as tees , Bend, Socket, Elbow, Peet Valve, Union, Nipple and hook etc. Cutting and threading testing in tranches in the ground and ISI 15mm i/d GM Ferrule as per IS:2692 and 3 inches i/d clamp with C.I Bib Cock, 15mm i/d as per is: 210 with Stainless Steel Spindle of approved make.
New Pumping Machinery Providing & installing, testing & commissioning of 1 no electrically driven Submersible Pump set capable of delivering 84LPM against a head of 64 mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter,Main Switch, VM,AMpere Meter, ELCB, Shunt capacitor. Single phase,preventer,Indicating lamps,Kit-Kat etc. including G.I column Pipe of IS 1239-2004 medium class size 50mm and Length 46 mtr.(in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 105 Mtr. Length and 2.50mm2 size as per IS694-1990 reaffirmed 2000 complete in all respects.
Motor 84 LPM, Head 64Mtr.
Panel Board
Cable (Size/Cost) 2.50mm2
Column Pipe (G.I)( Size/Length) (50mm i/d)
D.I Fitting Inside Pump Chamber. Providing and installing 80 mm dia delivery main (From Tube well to Duck Foot bend including cost of D.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as D.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects
Development of Water Works Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects.
Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4" x 4", size top 3" x 4",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects.
Providing & fixing D-Hook complete with MS Bolts size 300mm x 18mm as per complete in all respect.
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects.
Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per site complete in all respects.
Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per site complete in all respects.
Providing & fixing MS Sign Board as per site complete in all respects.
(Operation & Maintenance Cost Without Electricity Charges) Operation and Maintenance water supply system for 3 Months including operating of machinery , repair of leakages, supplying of full time Pump Operator cum- Chowkidar, supply of Sodium Hypo Chlorite solution for disinfection for 3 months after completion.
SOLAR PANELS Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capacity as per guidelines issued by PEDA complete in all respects.
Environmental Charges Surface dressing of ground including removing rank vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kinds of soil.
Supplying and planting permanent trees in prepared pits and watering.
Planting ground covers (ordinary) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row.
Planting seasonal flower in beds
Planting seedlings including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of seedlings at 20cm distance from plant to plant and row to row.
Provision for one way stand post with khura complete in all respects.
Carriage Statement Carriage of Material such as Bajri & Sand Upto lend 0-110 Km complete in all respect.
Bee Ess And Sons
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .