Staff Officer EnM SECL Sohagpur Area
Staff Officer EnM SECL Sohagpur Area Dhanpuri Distt Shahdol MP 9424141331
Testing and Calibration of different Electrical equipment related to HT installation installed at Surface Substation VCB OCB MOCB Transformers SF6 Breakers Protective Relays of Khairaha UG and Rajendra UG mine of R and K sub area of Sohagpur Area
2024_SECL_323479_1
SECL/SGP/EnM/eT/24-25/294 Dtd 16.12.2024
Open Tender
Miscellaneous Works
Item Rate
30 days
Rajendra UG and Khairaha UG
As per NIT and Tender documents
4 documents required · 4 mandatory
₹14,200
24 Apr 2025
18 Dec 2024
4 Jan 2025
18 Dec 2024
2 Jan 2025
19 Dec 2024
18 Dec 2024 - 26 Dec 2024
Amount
Testing and Calibration of different Electrical equipment related to HT installation installed at Surface Substation (VCB/OCB/MOCB, Transformers, SF6 Breakers, Protective Relays) of Khairaha UG mine & Rajendra UG mine of R&K sub area of Sohagpur Area, SECL
Part-A Providing, fixing and installation of Testing and Calibration of different electrical equipments related to HT installation installed at Surface sub-station (VCB/OCB, Transformers, SF6 Breakers, Protective Relays) at Khairaha UG mine - Testing and calibration of Protective Relays (IDMT/overload Relay, ELR, No Volt Relay/Master Trip Relay, WTI, OTI, Buchholz Relay etc.)
Testing and Calibration of 33KV/3.3KV/550V/440V Transformers (Ratio Test, Magnetic Balance Test, Vector Group Test, IR/PI Test, all field test of transformer as per applicable guidelines)
Testing of VCB, OCB, ACB (interlocking arrangement indication system/ operating mechanism etc. as per norms)
Testing of 3.3KV overhead line
IR/High Voltage Test of Cables, Testing & Calibration of all other protective/ measuring equipment (Meggers, Lux meter, multimeters etc.) in mine & surface. Note: Work also includes preparation of Single Line Diagram, Mine Plan, Test Reports etc.
Part-B Testing and Calibration of different Electrical equipments related to HT installation (OCB, Tranformers, MOCB, Protective Relays etc.) at Rajendra UG mine - Testing and calibration of Protective Relays (IDMT/overload Relay, ELR, No Volt Relay/Master Trip Relay, WTI, OTI, Buchholz Relay etc.)
Testing and Calibration of 33KV/3.3KV/550V/440V Transformers (Ratio Test, Magnetic Balance Test, Vector Group Test, IR/PI Test, all field test of transformer as per applicable guidelines)
Testing of VCB, OCB, ACB (interlocking arrangement indication system/ operating mechanism etc. as per norms)
Testing of 3.3KV overhead line
IR/High Voltage Test of Cables, Testing & Calibration of all other protective/ measuring equipment (Meggers, Lux meter, multimeters etc.) in mine & surface. Note: Work also includes preparation of Single Line Diagram, Mine Plan, Test Reports etc.
Total impact of GST for the purpose of CTC
ELECTRO ENGINEERING (BID ID -1111763)
P R ASSOCIATES (BID ID -1113247)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .