Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-Finance | ₹1.9 L | L1 | Accepted-Finance Accepted being L1 |
| 2 | L2₹2.4 L+₹41,300 (21.2%)Rejected-Finance | ₹2.4 L+₹41,300 (21.2%) | L2 | Rejected-Finance Rejected being L2 |
| 3 | L3₹2.4 L+₹42,480 (21.8%)Rejected-Finance | ₹2.4 L+₹42,480 (21.8%) | L3 | Rejected-Finance Rejected being L3 |
| Sl No | Description | Qty | Unit | surya systems L3 | J.B.Enterprises L2 | M/s Harshal Traders L1 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for A & B Preventive Maintenance Services of a Kirloskar Rotary Screw Air Compressor, Model KESe45-10, Serial No. SCR0008590 as per following details :-
Technical Specification / Scope of Work for carrying out A & B Preventive Maintenance Services of a Kirloskar Rotary Screw Air Compressor, Model KESe45-10, Serial No. SCR0008590. The exact consumables and service intervals should always follow the OEM maintenance manual for the compressor.
The A Service shall include the following preventive maintenance activities:
(a) General inspection of the compressor and associated equipment.
(b) Cleaning of air filters, cooler fins, and compressor enclosure.
(c) Inspection of inlet air filter element and replacement if required.
(d) Checking and tightening of all electrical terminals and cable connections.
(e) Inspection of belts/coupling for wear, alignment and tension.
(f) Checking lubricating oil level and topping up if required.
(g) Inspection for oil, air and condensate leakages.
(h) Draining condensate from air receiver, moisture separator and drain valves.(j) Inspection of safety valve, minimum pressure valve and non-return valve.(k) Checking operation of pressure switch, temperature sensors and control panel indications.(l) Recording operating parameters including:
Discharge pressure,Oil temperature,Motor current Running hours
Voltage,Functional test of compressor under load.
(m) Submission of service report with observations and recommendations.
The B Service shall include all activities covered under A Service, plus the following:
(a) Replacement of compressor lubricating oil (OEM approved) - 30 Ltrs .
(b) Replacement of Spin-ON oil filter Element - 02 nos
(c) Replacement of air suction filter element - 01 No
(d) Cleaning of oil cooler and after-cooler using compressed air or suitable cleaning method.
(e) Inspection and cleaning of cooling fan.
(f) Inspection of motor bearings and lubrication where applicable.
(g) Inspection of flexible hoses, piping and joints.
(k) Checking alignment and condition of drive system.
(l) Calibration/verification of pressure and temperature instruments, if applicable.
(m) Inspection and testing of safety devices and emergency shutdown functions.
(n) Performance testing after servicing to verify:
Rated pressure, Air delivery,Current consumption,Noise and vibration levels,Resetting service interval in the controller (if applicable).
(p) Submission of detailed maintenance report indicating replaced parts, observations and future recommendations.
Consumables
(q) Service shall be carried out by trained service personnel using genuine Kirloskar spare parts and OEM-recommended lubricants.
All work shall comply with the manufacturer's maintenance procedures and applicable industrial safety practices. | 1 | JOB | 2,01,000 ₹2,37,180 | 2,00,000 ₹2,36,000 | 1,65,000 ₹1,94,700 Lowest |
| 2.00M&L for A & B Preventive Maintenance Services of a Kirloskar Rotary Screw Air Compressor, Model KESe75-10, Serial No. SCR0009437 as per following detail. Technical Specification / Scope of Work for carrying out A & B Preventive Maintenance Services of a Kirloskar Rotary Screw Air Compressor, Model KESe75-10, Serial No. SCR0009437. The A Service shall include the following preventive maintenance activities: (a) General inspection of the compressor and associated equipment. (b) Cleaning of air filters, cooler fins, and compressor enclosure. (c) Inspection of inlet air filter element and replacement if required. (d) Checking and tightening of all electrical terminals and cable connections. (e) Inspection of belts/coupling for wear, alignment and tension. (f) Checking lubricating oil level and topping up if required. (g) Inspection for oil, air and condensate leakages. (h) Draining condensate from air receiver, moisture separator and drain valves.(j) Inspection of safety valve, minimum pressure valve and non-return valve.(k) Checking operation of pressure switch, temperature sensors and control panel indications. (l) Recording operating parameters including: Discharge pressure,Oil temperature,Motor current Running hours Voltage,Functional test of compressor under load. (m) Submission of service report with observations and recommendations. The B Service shall include all activities covered under A Service, plus the following: (a) Replacement of compressor lubricating oil (OEM approved) - 50 Ltrs . (b) Replacement of oil filter Element - 02 Nos (c) Replacement of air suction filter element - 01 No (d) Cleaning of oil cooler and after-cooler using compressed air or suitable cleaning method. (e) Inspection and cleaning of cooling fan. (f) Inspection of motor bearings and lubrication where applicable. (g) Inspection of flexible hoses, piping and joints. (k) Checking alignment and condition of drive system. (l) Calibration/verification of pressure and temperature instruments, if applicable. (m) Inspection and testing of safety devices and emergency shutdown functions. (n) Performance testing after servicing to verify: Rated pressure, Air delivery,Current consumption,Noise and vibration levels,Resetting service interval in the controller (if applicable). (p) Submission of detailed maintenance report indicating replaced parts, observations and future recommendations. Consumables (q) Service shall be carried out by trained service personnel using genuine Kirloskar spare parts and OEM-recommended lubricants. All work shall comply with the manufacturer's maintenance procedures and applicable industrial safety practices. | ||||||
| 3.00Note: 1. Old retrieved materials will be contractor’s property; hence, sch of credit Rs 1600.00 already deducted in the rate analysis. 2. GST % amount to be shown separately. | ||||||
Tender Value
Refer Docs
Closing Date
19 Aug 2026, 6:00 pmClosed
GE CENTRAL KHADKI
GE Central Khadki
JOB WORK REPAIR A and B PREVENTIVE MAINTENANCE SERVICES OF AIRCOMPRESSOR OFMODEL NO KESE 4510 AND KESE 7510 AT VRD PT I BUILDING AT 512 ABW AOR OFAGE EM II C UNDER GE C KHADKI
2026_MES_784039_1
3008/E-Qtn/05/E3
Limited
Job Works
Works
30 days
GE Central Khadki
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
27 Aug 2026
12 Aug 2026
21 Aug 2026
12 Aug 2026
19 Aug 2026
12 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for A & B Preventive Maintenance Services of a Kirloskar Rotary Screw Air Compressor, Model KESe45-10, Serial No. SCR0008590 as per following details :-
Technical Specification / Scope of Work for carrying out A & B Preventive Maintenance Services of a Kirloskar Rotary Screw Air Compressor, Model KESe45-10, Serial No. SCR0008590. The exact consumables and service intervals should always follow the OEM maintenance manual for the compressor.
The A Service shall include the following preventive maintenance activities:
(a) General inspection of the compressor and associated equipment.
(b) Cleaning of air filters, cooler fins, and compressor enclosure.
(c) Inspection of inlet air filter element and replacement if required.
(d) Checking and tightening of all electrical terminals and cable connections.
(e) Inspection of belts/coupling for wear, alignment and tension.
(f) Checking lubricating oil level and topping up if required.
(g) Inspection for oil, air and condensate leakages.
(h) Draining condensate from air receiver, moisture separator and drain valves.(j) Inspection of safety valve, minimum pressure valve and non-return valve.(k) Checking operation of pressure switch, temperature sensors and control panel indications.(l) Recording operating parameters including:
Discharge pressure,Oil temperature,Motor current Running hours
Voltage,Functional test of compressor under load.
(m) Submission of service report with observations and recommendations.
The B Service shall include all activities covered under A Service, plus the following:
(a) Replacement of compressor lubricating oil (OEM approved) - 30 Ltrs .
(b) Replacement of Spin-ON oil filter Element - 02 nos
(c) Replacement of air suction filter element - 01 No
(d) Cleaning of oil cooler and after-cooler using compressed air or suitable cleaning method.
(e) Inspection and cleaning of cooling fan.
(f) Inspection of motor bearings and lubrication where applicable.
(g) Inspection of flexible hoses, piping and joints.
(k) Checking alignment and condition of drive system.
(l) Calibration/verification of pressure and temperature instruments, if applicable.
(m) Inspection and testing of safety devices and emergency shutdown functions.
(n) Performance testing after servicing to verify:
Rated pressure, Air delivery,Current consumption,Noise and vibration levels,Resetting service interval in the controller (if applicable).
(p) Submission of detailed maintenance report indicating replaced parts, observations and future recommendations.
Consumables
(q) Service shall be carried out by trained service personnel using genuine Kirloskar spare parts and OEM-recommended lubricants.
All work shall comply with the manufacturer's maintenance procedures and applicable industrial safety practices. | 1 | JOB | - | - |
| 2 | M&L for A & B Preventive Maintenance Services of a Kirloskar Rotary Screw Air Compressor, Model KESe75-10, Serial No. SCR0009437 as per following detail.
Technical Specification / Scope of Work for carrying out A & B Preventive Maintenance Services of a Kirloskar Rotary Screw Air Compressor, Model KESe75-10, Serial No. SCR0009437.
The A Service shall include the following preventive maintenance activities:
(a) General inspection of the compressor and associated equipment.
(b) Cleaning of air filters, cooler fins, and compressor enclosure.
(c) Inspection of inlet air filter element and replacement if required.
(d) Checking and tightening of all electrical terminals and cable connections.
(e) Inspection of belts/coupling for wear, alignment and tension.
(f) Checking lubricating oil level and topping up if required.
(g) Inspection for oil, air and condensate leakages.
(h) Draining condensate from air receiver, moisture separator and drain valves.(j) Inspection of safety valve, minimum pressure valve and non-return valve.(k) Checking operation of pressure switch, temperature sensors and control panel indications.
(l) Recording operating parameters including:
Discharge pressure,Oil temperature,Motor current Running hours
Voltage,Functional test of compressor under load.
(m) Submission of service report with observations and recommendations.
The B Service shall include all activities covered under A Service, plus the following:
(a) Replacement of compressor lubricating oil (OEM approved) - 50 Ltrs .
(b) Replacement of oil filter Element - 02 Nos
(c) Replacement of air suction filter element - 01 No
(d) Cleaning of oil cooler and after-cooler using compressed air or suitable cleaning method.
(e) Inspection and cleaning of cooling fan. (f) Inspection of motor bearings and lubrication where applicable.
(g) Inspection of flexible hoses, piping and joints. (k) Checking alignment and condition of drive system.
(l) Calibration/verification of pressure and temperature instruments, if applicable.
(m) Inspection and testing of safety devices and emergency shutdown functions.
(n) Performance testing after servicing to verify:
Rated pressure, Air delivery,Current consumption,Noise and vibration levels,Resetting service interval in the controller (if applicable).
(p) Submission of detailed maintenance report indicating replaced parts, observations and future recommendations.
Consumables
(q) Service shall be carried out by trained service personnel using genuine Kirloskar spare parts and OEM-recommended lubricants.
All work shall comply with the manufacturer's maintenance procedures and applicable industrial safety practices. | - | - | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.06 MB
BOQ_878485.xls
BOQ • 0.28 MB
Appendix_A.pdf
Additional Documents • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .