Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC 96 1 HIMMATGANJ BEHIND UNANI MEDICAL COLLEGE PRAYAGRAJ 211001 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L1 | Accepted-AOC Accepted being lowest quoted tenderer | |
| 2 | L2₹30.0 L+₹10,056 (0.34%)Rejected-AOC | L2 | Rejected-AOC Rejected being other than lowest quoted tenderer | |
| 3 | L3₹33.9 L+₹4.0 L (13.6%)Rejected-AOC | L3 | Rejected-AOC Rejected being other than lowest quoted tenderer | |
| 4 | L4₹35.0 L+₹5.2 L (17.3%)Rejected-AOC VAIDHYA GALI KHERAGARH AGRA 283121 | AGRA | AGRA | UTTAR PRADESH | 283121 | L4 | Rejected-AOC Rejected being other than lowest quoted tenderer | |
| 5 | L5₹37.5 L+₹7.6 L (25.6%)Rejected-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L5 | Rejected-AOC Rejected being other than lowest quoted tenderer |
| Sl No | Description | Qty | Unit | Ambrish Builders L3 | ABHISHEK ENTERPRISES L5 | Madhu Electricals and Engineering Works L2 | M/S KAMAKHYA CONTRACTORS L4 | M/S SHIV BALLABH MISHRA L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in soft/ loose soil trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out for taking out/laying/ cleaning/ repairing of CI/GI pipe line, cable etc including making good to disturbed surfaces complete all as specified and directed. | 1,000 | Cum | 150 ₹1,50,000 | 175 ₹1,75,000 | 68 ₹68,000 Lowest | 120 ₹1,20,000 | 110 ₹1,10,000 |
| 2.00 | Returning, filling in & including spreading, levelling & well ramming in layers not exceeding 25 cm thick as in soft/loose soil complete all as specified and directed. | 800 | Cum | 30 ₹24,000 | 20 ₹16,000 | 18 ₹14,400 Lowest | 50 ₹40,000 | 40 ₹32,000 |
| 3.00 | Removal of surplus spoil to a distance not exceeding 50 mtr depositing where directed at a level not exceeding 1.5 mtr above ground level complete all as specified and directed. | 200 | Cum | 40 ₹8,000 | 30 ₹6,000 | 14 ₹2,800 Lowest | 50 ₹10,000 | 40 ₹8,000 |
| 4.00 | M&L for Boring of holes of 150 mm dia under the road/ hard standing with Trenchless technology boring method upto 2 mtr below the surface for fixing water supply line complete all as specified and directed.
Note:- All Equipments & Machinery required to carry out the work will be provided by the contractor (If due to any obstruction during boring, reboring has to be done the same will be done by the contractor at his own cost the rates deem to cover the same). | 50 | RM | 3,000 ₹1,50,000 | 900 ₹45,000 | 482 ₹24,100 | 250 ₹12,500 Lowest | 350 ₹17,500 |
| 5.00Taking up unserviceable CI/DI rusted/ broken pipe line (including all fittings) with spigot and socket/ Flanged ends and removal from site including burning out joints and recovering lead complete all as specified and directed for the following sizes/bores of pipes :-(Earth work shall be measured and paid separately). | ||||||||
| 5.01 | 150mm bore dia | 350 | RM | 40 ₹14,000 | 10 ₹3,500 Lowest | 33 ₹11,550 | 50 ₹17,500 | 60 ₹21,000 |
| 5.02 | 100mm bore dia | 350 | RM | 30 ₹10,500 | 5 ₹1,750 Lowest | 20 ₹7,000 | 50 ₹17,500 | 45 ₹15,750 |
| 6.00Relaying only in trenches of old pipe retrived and cleaning serviceable CI/DI pipe line apply stainless rod with spigot and socketed ends complete after cleaning properly/thoroughly & removal of all blockage removing all silt and deposited organics inside using bamboo or rod with brush complete all as specified and directed for the following sizes/bore of pipes :- | ||||||||
| 6.01 | 150mm bore dia | 300 | RM | 60 ₹18,000 | 125 ₹37,500 | 47 ₹14,100 Lowest | 85 ₹25,500 | 65 ₹19,500 |
| 6.02 | 100mm bore dia | 300 | RM | 50 ₹15,000 | 100 ₹30,000 | 44 ₹13,200 Lowest | 75 ₹22,500 | 50 ₹15,000 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
13 Jan 2026, 6:00 pmClosed
New Cantt Prayagraj
HQ CWE New Cantt Prayagraj
MAINT/ REPAIR/ UPKEEP OF WATER SUPPLY NETWORK AT EAST OF AKBAR ROAD AT NEW CANTT UNDER GE (WEST) PRAYAGRAJ.
2025_MES_745872_1
82053/W/E8
Open Tender
Civil Works
Item Rate
180 days
Prayagraj
Class D and Category a(ii)
6 documents required · 6 mandatory
₹500
GE (West) Pryagraj
₹1 L
Yes
17 Mar 2026
23 Dec 2025
20 Jan 2026
23 Dec 2025
13 Jan 2026
6 Jan 2026
Excavation in soft/ loose soil trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out for taking out/laying/ cleaning/ repairing of CI/GI pipe line, cable etc including making good to disturbed surfaces complete all as specified and directed.
Returning, filling in & including spreading, levelling & well ramming in layers not exceeding 25 cm thick as in soft/loose soil complete all as specified and directed.
Removal of surplus spoil to a distance not exceeding 50 mtr depositing where directed at a level not exceeding 1.5 mtr above ground level complete all as specified and directed.
M&L for Boring of holes of 150 mm dia under the road/ hard standing with Trenchless technology boring method upto 2 mtr below the surface for fixing water supply line complete all as specified and directed. Note:- All Equipments & Machinery required to carry out the work will be provided by the contractor (If due to any obstruction during boring, reboring has to be done the same will be done by the contractor at his own cost the rates deem to cover the same).
Taking up unserviceable CI/DI rusted/ broken pipe line (including all fittings) with spigot and socket/ Flanged ends and removal from site including burning out joints and recovering lead complete all as specified and directed for the following sizes/bores of pipes :-(Earth work shall be measured and paid separately).
150mm bore dia
100mm bore dia
Relaying only in trenches of old pipe retrived and cleaning serviceable CI/DI pipe line apply stainless rod with spigot and socketed ends complete after cleaning properly/thoroughly & removal of all blockage removing all silt and deposited organics inside using bamboo or rod with brush complete all as specified and directed for the following sizes/bore of pipes :-
150mm bore dia
100mm bore dia
Supply & laying in trenches ductile iron (DI) pipe with spigot and socketed ends centrifugally cast class 'K-7' in any length laid in trenches complete all as specified and directed for the following sizes/bore of pipes (DI fittings and jointing materials shall be measured and paid separately) :-
150 mm bore dia.
100 mm bore dia.
M&L for cutting of the CI/DI pipe in position for insert of new tee, branches such as Tees/Reducers/Tail pieces/collers/sluice valve/Air release valve etc.with suitable size of clamp of size 40 x 6 mm with nuts, bolts and washer of the following sizes complete all as specified and directed:-
150 mm bore.
100 mm bore.
M&L for upto 150 mm bore ductile iron (DI) fittings such as bends (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, “Y” junction, double branch, cross (all sockets or socket and spigot) collars, flanged spigot,caps and plugs complete all as specified and directed.
M&L for run lead joints for cast iron spigot and socketed pipes and filling of 80mm bore pipe joint complete all as specified and directed.
M&L for run lead joints for cast iron spigot and socketed pipes and filling of 100mm bore pipe joint complete all as specified and directed.
M&L for run lead joints for cast iron spigot and socketed pipes and filling of 150mm bore pipe joint complete all as specified and directed.
M&L for actual detecting the leakage of existing CI/DI pipe any type and repairing the joint with new lead & jute/wool refixing after testing for leakage proof pipe line for making good for detecting leakage of existing CI / DI Pipe line only laying and reparing :- Note :- Excavation and joiting material, earth work will be measured and paid separately.
150 mm bore.
100 mm bore.
80 mm bore.
All as per sl item No. 13 here-in-before but using old lead.
150 mm bore
100 mm bore
80 mm bore
M&L for actual detecting the leakage of existing GI pipe line any type laid in trenches/ wall/ floor including excavation upto one cum taking out existing pipeline and repair including replacement of GI fitting such as tee, socket, reducer, elbow, union, etc complete and refixing after testing for leakage proof pipe line and making good disturbed surface complete for following bore of GI pipe line :- Note :- Excavation and earth work will be measured and paid separately.
32 to 80 mm GI pipe.
15 to 25 mm GI pipe.
Supply, fixing, jointing and testing in repair of cast iron sluice valve class (ISI MARKED) PN-1.6 type latest IS 14846-2000 flanged ends, drilled having stainless steel spindle with cast iron wheel head at top complete with nuts, bolts, washer and rubber gasket etc complete including taking down unserviceable sluice valve complete all as specified and directed for following bore of CI pipe line :-
150 mm dia bore.
100 mm dia bore.
Dismantling old broken / damaged valve pit chamber and construct valve pit chamber of size 1050mm x 1050 mm x 1050 mm (internal dimention) complete including excavation and earth work, PCC 1:4:8, type D-2 using 40mm graded stone aggregate as in foundation, brick work in cement mortar 1:6, plastering in cement mortar 1:4 (internally) and including 3mm thick mild steel sheet cover fixed in frame of size 40x40x6mm with handle and locking arangement and painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
All as per sl item No 17 above but size of valve chamber is 900 x 900 x 900 mm (internal) and all as specified and directed.
All as per sl item No 17 above but size of valve chamber is 450x 450 x 450 mm (internal) and all as specified and directed.
M&L for packing pea gravels of size 3 to 5 mm natural shape brought direct from river bank packing around casing pipe to entire depth upto ground level complete all as specified and directed by Engineer-in-Charge.
M&L for development of tube well by means air compresser 600 PSI including equipment fitting and supply sodium hepta sulphate 60 Kg complete all as specified and directed by Engineer-in-Charge.
S&F submersible pump of capacity 40/41 HP with electric driven motors of suitable capacity as per design 3 Phasae 415 Volt with head 70.00 M to 110 Mtr and dicharge 1400 LPM to 2800 LPM complete including taking down unserviceable submersible pump complete all as specified and directed and making electrical connection and testing complete to eniter satisfaction of Enginer in charge :-
Taking up old rusted GI / UPVC / CPVC / PPR Pipes and connections including clearing the pipes free from scaling for reusing the same complete all as directed for the following sizes :- Note :-Excavation will be measured and paid separately.
75 mm dia bore.
50 mm dia bore.
40mm dia bore.
25 mm dia bore
20 mm dia bore.
15 mm dia bore.
Relaying/ refixing of old steel tubing and connection in new or old position including necessary cuttings, threading, and new fittings such as bends, elbows, socket nipples, tapers, and reducers etc all as specified and directed
50 mm dia bore.
.40 mm dia bore
25 mm dia bore.
20 mm dia bore.
15 mm dia bore.
Supply and lay steel water tubing GI medium grade ISI marked with all fittings laid in trenches or fixed to wall etc complete for the following all as specified. Note :- Excavation and earth work will be measured and paid separately.
50 mm dia bore.
40 mm dia bore.
25 mm dia bore.
20 mm dia bore.
15 mm dia bore .
Supply and laying in 3- layer PP-R Poly propylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches. PPR Pipes heavy duty pipes with working pessure 6 Kg/SqCm and certified with ISI standards with all fitting such as Union, reducers, elbow, tee, socket, brass insert , MTA complete of suitable size laid in trenches / upto service tank complete with solvent of the following size with all fitting complete all as specified and directed :-
75 mm outer dia.
50 mm outer dia.
40 mm outer dia.
25 mm outer dia.
20 mm outer dia.
Supply and fix PPR Gate Valves (Brass Insert) ISI marked head screwed both ends for PPR pipes and fixed for the following sizes
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.49 MB
BOQ_835175.xls
BOQ • 0.38 MB
Indexpageandfwdingpage.pdf
Tender Documents • 0.61 MB
Specialcondition.pdf
Additional Documents • 0.45 MB
Particularspecifications.pdf
Additional Documents • 1.07 MB
Makes.pdf
Additional Documents • 0.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .