Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹17.6 L+₹1.8 L (11.1%)Rejected-Finance C 89 CECC VILL POST PATHOLI AGRA UP | AGRA | AGRA | UTTAR PRADESH | 283105 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹20.3 L+₹4.4 L (27.9%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹20.9 L+₹5.1 L (32.1%)Rejected-Finance EY 04 PODA WC CHANDIGARH A I A II B I | CHANDIGARH | CHANDIGARH | 160001 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹21.5 L+₹5.7 L (35.8%)Rejected-Finance 19 TAGORE PUBLIC SCHOOL COMPLEX SEWLA SARAI MALOOK CHAND GWALIOR ROAD AGRA UP 282001 | AGRA | AGRA | UP | 282001 | L5 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | K C ASSOCIATES L4 | m/s shanti consruction co L6 | C P Singh and Co L2 | MNR ASSOCIATES L10 | M/S RISHI RAJ AGRAWAL L3 | N.K. ENTERPRISES L8 | Lachman Das Govind Ram L9 | M/s Srijan Construction Company L5 | RAJESH ENTERPRISES L1 | Abhi Construction L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed. | 10.86 | Cum | 160 ₹1,737.6 | 150 ₹1,629 | 100 ₹1,086 Lowest | 120 ₹1,303.2 | 100 ₹1,086 Lowest | 280 ₹3,040.8 | 150 ₹1,629 | 200 ₹2,172 | 100 ₹1,086 Lowest | 250 ₹2,715 |
| 2.00 | M&L cement concrete type B-0, 1:2:4 mix ( 12.5 mm graded agg) in, padding, roof kerbs or mud stops, rounded or chamfered on edges coping and similar work all as specified and directed. | 1 | Cum | 3,500 ₹3,500 Lowest | 4,000 ₹4,000 | 5,000 ₹5,000 | 7,200 ₹7,200 | 4,000 ₹4,000 | 6,780 ₹6,780 | 6,000 ₹6,000 | 5,000 ₹5,000 | 3,800 ₹3,800 | 5,000 ₹5,000 |
| 3.00 | M&L for Cement concrete 1:2:4 type B-1 ( using 20mm graded crushed stone aggregate) as in floor etc and similar work all as specified and directed. | 1 | Cum | 4,000 ₹4,000 | 4,000 ₹4,000 | 5,000 ₹5,000 | 7,200 ₹7,200 | 4,000 ₹4,000 | 6,490 ₹6,490 | 5,900 ₹5,900 | 5,000 ₹5,000 | 3,000 ₹3,000 Lowest | 5,000 ₹5,000 |
| 4.00 | PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection ( 75 mm thick ) laying in alternate ways finished even and smooth without using extra cement plinth protection shall be laid to alternate bay system each bay shall exceed 3m in lentgth 12mm wide and 75mm deep joint sall be filed with hot blown bitumen 85/25 and sand complete all as specified and directed. | 68 | Sqm | 320 ₹21,760 | 250 ₹17,000 | 200 ₹13,600 | 270 ₹18,360 | 200 ₹13,600 | 320 ₹21,760 | 250 ₹17,000 | 450 ₹30,600 | 120 ₹8,160 Lowest | 270 ₹18,360 |
| 5.00 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar ficings, dressed stone work and pre-cast concrete articles complete all as specified and directed. | 15 | Cum | 220 ₹3,300 | 140 ₹2,100 | 100 ₹1,500 Lowest | 120 ₹1,800 | 100 ₹1,500 Lowest | 330 ₹4,950 | 250 ₹3,750 | 500 ₹7,500 | 150 ₹2,250 | 250 ₹3,750 |
| 6.00 | M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed | 10 | Cum | 6,500 ₹65,000 | 4,000 ₹40,000 | 3,500 ₹35,000 Lowest | 4,800 ₹48,000 | 3,500 ₹35,000 Lowest | 5,100 ₹51,000 | 5,000 ₹50,000 | 4,500 ₹45,000 | 3,800 ₹38,000 | 5,000 ₹50,000 |
| 7.00 | M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed but except brick.
Note:- Bricks obtained from item No 8 shall be reused after cleaning. | 5 | Cum | 6,000 ₹30,000 | 1,800 ₹9,000 | 500 ₹2,500 Lowest | 3,000 ₹15,000 | 2,500 ₹12,500 | 2,000 ₹10,000 | 1,500 ₹7,500 | 4,000 ₹20,000 | 2,000 ₹10,000 | 1,800 ₹9,000 |
| 8.00 | Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. | 560 | Sqm | 25 ₹14,000 | 10 ₹5,600 Lowest | 20 ₹11,200 | 24 ₹13,440 | 10 ₹5,600 Lowest | 45 ₹25,200 | 10 ₹5,600 Lowest | 20 ₹11,200 | 10 ₹5,600 Lowest | 15 ₹8,400 |
| 9.00 | M & L Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying ement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified (Payment for providing grooves shall be made separately). | 130 | Sqm | 450 ₹58,500 Lowest | 680 ₹88,400 | 600 ₹78,000 | 1,200 ₹1,56,000 | 630 ₹81,900 | 850 ₹1,10,500 | 670 ₹87,100 | 850 ₹1,10,500 | 650 ₹84,500 | 700 ₹91,000 |
| 10.00 | Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge | 180 | Rm | 280 ₹50,400 | 40 ₹7,200 | 30 ₹5,400 | 48 ₹8,640 | 78 ₹14,040 | 50 ₹9,000 | 40 ₹7,200 | 50 ₹9,000 | 20 ₹3,600 Lowest | 40 ₹7,200 |
Tender Value
₹25.3 L
EMD Value
₹50,509
Closing Date
25 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE West Agra
62 Station Road, Agra Cantt
SPL REPAIR TO BLDG NO T-60 OF 9 PARA FD REGT UNDER GE(W) AGRA.
2025_MES_712479_1
8012/1096/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Agra
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE West Agra
₹50,509
23 Sept 2025
4 Jun 2025
2 Jul 2025
4 Jun 2025
25 Jun 2025
18 Jun 2025
4 Jun 2025 - 11 Jun 2025
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
M&L cement concrete type B-0, 1:2:4 mix ( 12.5 mm graded agg) in, padding, roof kerbs or mud stops, rounded or chamfered on edges coping and similar work all as specified and directed.
M&L for Cement concrete 1:2:4 type B-1 ( using 20mm graded crushed stone aggregate) as in floor etc and similar work all as specified and directed.
PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection ( 75 mm thick ) laying in alternate ways finished even and smooth without using extra cement plinth protection shall be laid to alternate bay system each bay shall exceed 3m in lentgth 12mm wide and 75mm deep joint sall be filed with hot blown bitumen 85/25 and sand complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar ficings, dressed stone work and pre-cast concrete articles complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed
M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed but except brick. Note:- Bricks obtained from item No 8 shall be reused after cleaning.
Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M & L Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying ement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified (Payment for providing grooves shall be made separately).
Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge
M&L for 15mm thick rendering in CM 1:6 on any faces of brick or concrete surfaces of walls & finishing the surface even and fair without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on brick or concrete surface with water proofing compound finished other than fair complete all as specified and directed. Note : Water proofing compound will be measured and paid seperately under respective item of Sch ‘A’.
Supply only liquid water proofing compound complete all as specified and directed.
M&L Preparing newly plastered or un plastered surfaces of wall and applying two coats of oil bound distemper with roller application over a coat of primer over a coat of average 1mm thick wall care putty on new plastered surfaces complete all as specified and directed.
M&L for applying two coats of oil bound distemper with roller on old decorated wall surfaces over 1 mm thick white putty including complete removal of existing treatment with mechanical complete all as specified and directed.
M & L for applying 1mm thick water proofing putty and two coats of Acrylic weather proof Exterior paint on new plastered or unplastered surface of walls or concrete including preparation of surfaces at any height (not exc11 Mtr) including necessary scaffolding/centering etc complete all as specified and directed.
M&L for applying three coats of white wash on wall including preparation of new plastered or un-plastered surfaces of walls, complete all as specified and directed.
M&L for applying two coats of white wash on ceiling including complete removal of existing treatment with mechanical complete, complete all as specified and directed.
M&L in Making good in CM 1 :4 under cills or over arches, lintels and bressummers. including allpinning when necessary complete all as specified and directed
M & L cutting holes into or through brick wall built in cement mortar superfacial area exc 150 Sqcm not exc 400 Sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
Dismantling timber scantling 40 Sqcm and over in section framed work in any position complete all as specified and as directed.
Dismantling structural steel work in cluding doors, gates but excluding framed truss etc. complete all as specified and as directed by Engr-in-charge
Dismentling wall and ceiling board or insulation board /slabs/blanket any thickness including cover fillets.complete all as specified and as directed by Engr-in-charge
Dismentling of Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings
S&F rolled MS Fe 410W (Gde E-250) quality A for Roof truses (framed), trussed, purlins, crane grantries, rails and fasternings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, clests etc complete all as specified and directed.
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet AZ - 150 thickness of sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet AZ - 150 thickness of sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Providing & fixing false ceiling at all heights with fully perforated 12mm thick micro tegular edged GRG (Glass Fibre Reinforced Gypsum false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99%, NRCO 50 to 0.75 as per IS 8225:1987, Noncombustible as BS 476 (part4)-1970 and light reflected of 85% (minimum) to be laid in true horizontal level suspesded on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (glvanized @ 120 grams per sqm including both sides) compresing of maint runners of size 15x32 mm of length 3000mm, cross -T of size 15x32mm of length 1200mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to from grid module of size 600x600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm ) i.e 50mm long. 8mm outer diameter M-6 dash fasteners,6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm Galavanised iron perimeter wall angle of size 24x24x0.40mm of length 3000 mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood srews. complete all as specified and directed by Engineer-in Charge.
S&F Loouvers Prelam PVC wall panelling of rigiit Upvc foam profiles with integrated skin of size203x30x4.5mm of density 1000kg/cbm manufactured by an ISO 9001-2015 certified compony, having tounge and groove design with inter locking facility, will be fixed in perpendiculordirection at the face wallusing 8x38mm steel screwat every 450mm centre to centre covering to avoide leakage through joints.the profile are to b e jointed and finished so as to have a flush lock witch includes filling and finishing with joined comound(Adhesive) between brick wall & wall linninginclude L/T & C type bedding all as per manufacturers instruction and directed by Engieer -In Charge, complete all as specified and directed .
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
M&L for coloured glazed ceramic tiles (out door tiles ) in vertical surface 350 x 250 x 7 mm / 450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match tiles including 10mm thick rendering in CM 1:4 on brick wall complete all as specified and as directed .
M&L vertified ceramic tiles 10 mm thick (square/rectangular) area of each tile exceeding not exc. 0.36Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cment mortar (1:6) complete all as specified and directed.(toilet,bath,kitchen, passage floor)
M&L vertified ceramic tiles 10 mm thick (square/rectangular) area of each tile exceeding not exc. 0.36Sqm as in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 10mm thick rendering in CM (1:4) complete all as specified and directed.(toilet,bath,kitchen, passage floor)
M&L non skid joint free coloured tiles (1st quality/premium quality) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18Sqm but not exc. 0.38 Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cment mortar (1:6) complete all as specified and directed. (bed room and other room floor)
M&L 25 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in sub base of flooring finished even and fair without using extra cement complete all as specified & directed.
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete laid over and including 20mm thick screed bed CM (1:6) complete all as specified and directed.
M&L Machine cut kota stone 20-25 mm thick as in riser of step, skirting,dado and pillar etc. laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing laid over and including 15mm thick rendering CM (1:4) complete all as specified and directed.
M&L 18/20mm thick black granite (of any type) work (table rubbed and polished) in steps jambs, pillars, window cills, cooking plateforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of stone including rounding and moulding of edge and making hole for cooking gas pipe complete all as specified and as directed.
S&F in repair 1000 ltrs capacity rotational moulded polyethylene water storage tank double layered, ISI engraved (cylindrical vertical with closed top) hoisted and fixed in position incl dismantling of water tank complete all as specified & directed.
S&F 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20 mm dia (minimum weight - 210 gm) complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connection complete all as specified and directed.
S&F 20mm bore GI tubes medium grade, galvanised with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
S&F for framed work such as grills, grating etc. with ends of bars shouldered and/or riveted or forged into spike, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing framed work of water tank and similar work confirming to Fe 290 Gde E-165 complete all as specified and directed.
S & F for providing and fixing stainless steel (Grade 304) railing made of hollow tubes channels, plates etc. including welding, grinding, buffing, polishing and making curvature (where ever required ) and fitting the same with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of floor or the side of waist slab with suitable arrangements complete all as specified and dfirected.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n. exc 1.5 Sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 Sqm but not exc 4 sqm each complete all as specified and directed.
M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45X85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be madeetc complete all as specified and directed.
S&F for factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and including fixing with 100mm long stainless steel butt hinges -04Nos with necessary full body threaded star headed counter sunk S.S screws, complete all as per specified and directed.
S&F aluminium powder coated (50 micron thick) door shutter area exc 1.50sqm but nexc 2.5 sqm each fixed to wall with min four number steel fastners, partly glazed with 5 mm thick tinted glass and partly panelled with 8mm thick colouered aluminium composit panels incl rubber beading, joining cleat for fixing in position, with aluminium fixtures; 2 numbers door handle 250 mm long, 1 number barrel tower bolt 200 mm long ,1 number floor door spring & one No 4 liver mortice lock of Godrej of size 100 mm in each shutter all as specified and directed as per following specifications -- (a) Style Section shall be of size 85.00 x 44.45 x 1.50 mm (Section No 19560) (b) Top rail Section shall be of size 85.00 x 44.45 x 1.50 mm (Section No 19581) (c) Lock rail Section shall be of size 150.00 x 44.45 x 1.50 mm (Section No 19596) (d) Bottom rail Section shall be of size 150.00 x 44.45 x 1.50 mm (Section No 19584) (e) Glazing clip 0.80 mm thick (Section No 19370). (f) Top, Bottom and verticle member of shutters will be tightened with hexagonal nut and purpusly made bolt of 10mm dia MS round bar threaded on both the end . Note:-(i) Section make Jindal or equivelent from list.
S& F for aluminium anodised powder coated frame for doors, windows ventilator with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
S & F aluminium powder coated three track window as per Make: Jindal Series "C" of thickness 1.5mm ( two shutters glazed & one shutters wire gauge) with frame, glazed with 4 mm thick tinted glass and, wire gauge with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm including rubber bead joining cleat for fixing in position, concealed type lock for all three shutter, PVC roller etc all as specified and directed Note:-(i) Make Jindal or equivelent form other make mention in Appx B.
S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F 150 mm long aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F Floor door stopper 150 mm long of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor
S&F 100 mm long stainless steel hinges type B-12 complete all as specified and directed.
S & F Mild steel Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, clamps, plain angle cleats for securing purlins and similar small articles confirming to Fe 290 complete all as specified and directed.
M&L cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in bed blocks for fixing hold fasts etc. complete all as specified and directed.
M & L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10 cm width or girth, not otherwise described complete all as specified and directed.
M & L for applying one coat of synthetic enamel paint including preparation of old Iron surface of any discription not otherwise discribed over 10 cm width or girth, complete all as specified and directed.
Taking down and refixing of Aluminium door incuding all fittings , rubber packing etc etc, and repairing of existing surface. complete all as specified and directed. NOTE- full precaution should take while taking down and refixing ,0f aluminium glass door.
Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/ colour /plaster to match with the existing location spot complete all as specified & directed.
M&L for concealed point wiring for one light point/fan point/bell point controlled by one switch (using red, black and green colour coding) complete with 1.5 sqmm unsheathe and multi stranded copper conductor single core FRLSH PVC insulated, 1100 volts PVC insulated unsheathed cable with proper colour coding drawn in through and including PVC concealed conduit not less than 25 mm dia ( medium duty, ISI marked) with all fittings and accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc.,including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 60mm deep, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing modular switches/ socket/ regulator etc, including provn of sqmm single core FRLSH PVC insulated multi standed copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ ceiling/ floors etc by using CM (1:3) complete all as specified and as directed. NOTE:- Modular switches/ socket/ regulator shall be measured and paid separately under appropriate
All as per item No 63 here in before but One socket outlet 5/6 Amps on independent switch board controlled by one switch complete it with 2.5 sqmm unsheathed and multistranded copper conductor single core FRLSH PVC insulated, complete all as specified & directed.
All as per item No 63 here in before but One socket outlet 5/6 Amps controlled by one switch on same board with other switches complete it with 2.5 sqmm unshethed and multistranded copper conductor single core FRLSH PVC insulated, complete all as specified & directed.
All as per item No 63 here in before but using 2.5 sqmm PVC FRLS insulated stranded copper conductor cable and for one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed. NOTE-For item no 63 to 66 -: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (ii) Fittings like switches,sockets,regulators,lamp holders,light fittings shall be measured and paid for separately under appropriate item of schedule A. (iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 25 mm dia (medium grade).
All as per item No-66 above but using 4.0 sqmm PVC FRLS insulated stranded copper conductor cable and for one socket outlet 3/5/6 pin, 15/16A controlled by one way switch on an independent board complete all as specified and directed.
Supply and fixing modular switch piano single pole, one way 6 Amps 1 module, complete all as specified and directed.
Supply and fixing modular switch piano type 16 Amps single pole one way, one module, complete all as specified and directed.
Supply and fixing modular socket outlet 3 pin 6 Amps combined 2 module, complete all as specified and directed.
Supply and fixing modular socket multipurpose 3/5 pin 6/16 Amps combined 2 module, complete all as specified and directed.
Supply and fixing modular step type, 2 module electronic fan regulator heavy duty 120watts 240 volts,complete all as specified and directed.
Supply and fixing modular cover plate with metal frame (inner and outer) 2 module for mounting switch and sockets all as specified and as directed.
Supply and fixing modular cover plate with metal frame (inner and outer) 3 module for mounting switch and sockets all as specified and as directed.
Supply and fixing modular cover plate with metal frame (inner and outer) 4 module for mounting switch and sockets all as specified and as directed.
Supply and fixing modular cover plate with metal frame (inner and outer) 6 module for mounting switch and sockets all as specified and as directed.
Supply and fixing modular cover plate with metal frame (inner and outer) 8 module for mounting switch and sockets all as specified and as directed.
Supply & fixing for ceiling rose PVC Polycarbonate isolated body 62.5 x 25 mm, three terminals, complete all as specified & directed.
Supply & fix commissioning and testing of complete power cum starter unit compressing of ON/OFF switches socket 3 pin socket outlet with plug top modular type made out of white polycarbonate, fire retardant, UV stabilized power unit internally pre-wired with suitable size copper conductor cable with overload protective device (MCB) complete unit fixed in single polycarbonate housing with inlet & outlet cable port suitable for AC & geyser operated at single phase, 240 volts, 50 Hz AC supply of capacity 32 Amps load bearing capacity complete all as specified and directed.
Supply and fix lamp holder insulated body with back plate for batten fitting complete all as specified and directed.
Supply and fixing LED Bulb 12 watt, colour temp-6500K, lum output-945lm, Base cap- B22 single phase, 230 Volts AC supply suitable for lamp holder complete all as specified and directed.
S&F in replacement LED Batten surface/wall mounted with specially designed powder coated aluminium housing,high optically efficient polycarbonate diffuser,in built electronic driver duly wired up to terminal block,power consumption<20W,luminaire lumen >2000 lm,system efficiency of >120 lumens/W,LED make Nichia/Cree/Everlite/Eclison/Osram/lumiled,with LED binning as per ANSI Bin C78.377A,photo biological safety report as per IEC 624718& electrical insulation class 1 Ingress protection IP 20,color rendering index CRI> 80 ,temp range 0 to 450 C ,driver efficiency >85% Power factor >0.9 THD <20% as per IEC 61000-3-2 ,color temp -6500K,Surge protection 2.5 KV,50000 burning hrs (min) as per L7O criteria,two stages isolated constant current operated driver with range 150-270 V AC and safety extra low voltage safe level< 60 V DC as per IEC standard with LM70 & LM 80 certification.
S&F in replacement LED security with aluminum pressure die cast housing, high purity PC fresnel diffuser with silicon gaskets for IP-65 protection, power consumption < 35 W and system efficiency > 100lm /W, in built electronic driver pre-wired upto terminal block with driver efficiency > 85% power factor > 0.95, suitable for external pole upto 35mm LED Make :- Nichia/Cree/Osram, CRI > 70, ambient temperature range 0-450c, THD<10%, colour temperature 5700K, surge protection cm 3.5KV 50000burning hour as per L70 criteria, multistage constant current constant voltage operated driver with range 150 -270 V AC and safety extra low voltage safe level < 60V DC as per IEC standard including GI pipe light ISI mark of size 25 mm dia length not less than 1.5 mtrs bending to shape for fixing light and nuts, bolts, clamp as required to fix to wall all as specified and directed.
Taking down care fully sub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor .
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
Taking down distribution boards any size any type including MCB TPN/SPN/SP/DB etc and making good the disturbed surfaces.
Supply and fix MCB DB vertical type 4 way VTPN sheet metal enclosure 415 volts with 100 Amp fully insulated standard copper bus bar for each face & surrounded with neutral bars and two common neutral bar, two earth bar including cable ties for cable management suitable for housing MCCB TPN 415 Volts as incomer, IP-43, IK-09 as per IEC 61439-3 with metal doors all enclosed on standard steel sheet flush mounting type double door factory fabricated complete without MCB & MCCB but with enclosure blank plate complete all as specified and directed .
Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 12 way with 100 amps rated copper bus bar 240 volts IP-54, IK-09 with metal doors complete all as specified and directed.
Supply and fixing in replacement MCB SPN 240V, 50 Hz, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity SPN 40 to 63 Amp rating in the MCB DB complete with connection testing and commissioning complete all as specified & directed.
Supply & fix in replacement MCB SP, 40 Amps, 'C' Curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed.
Supply & fix MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN/FP and current carrying capacityTPN 40 to 100A in the DB complete with connection testing and commissioning.
Taking down and fixing only electric metres during the execution of work, complete all as specified and directed.
M&L for electrically disconnecting and taking down existing ceiling/Exhaust fans from any height or in any position from existing bldg and keeping in safe custody for reuse at site after necessary repair/ servicing & painting with one coat of synthetic enable paint and re hanging/ re-fixing in original position but including replacement of three cor flexible copper conductor cable from ceiling rose to fan connector block of size 0.75 Sqmm and hanging fan clamps, nuts, bolts and rubber reel bush etc & testing for proper functioning complete all as directed at site by Engr-in-Charge
M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanized steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Loose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 .
Disconnecting & taking up or down existing unserviceable UG cable/service wire aluminium conductor including GI wire any size and type, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 4 core.
Material and labour for cutting the road for laying of pipe and repair the same with cement concrete work in pavement/hard standing using 400kg of cement per cubic meter all as directed as site.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose/ soil for taking out/laying CI/GI pipe line and getting out soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed by Engineer-in-Charge.
Supplying and laying un-reinforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable.
M&L for sand cushioning dry fine for cable cushioning below and above the cable complete all as directed at site by Engr- in-Charge.
Supply and fixing GI Pipe 40mm Light grade , for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed at site.
C P Singh and Co (BID ID -3336739)
M/S RISHI RAJ AGRAWAL (BID ID -3336802)
K C ASSOCIATES (BID ID -3336233)
M/s Srijan Construction Company (BID ID -3333435)
m/s shanti consruction co (BID ID -3336695)
Abhi Construction (BID ID -3336088)
N.K. ENTERPRISES (BID ID -3336835)
Lachman Das Govind Ram (BID ID -3330682)
MNR ASSOCIATES (BID ID -3336758)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .