Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹4.0 L+₹26,693 (7.07%)Rejected-AOC | L2 | Rejected-AOC L1 being accepted | |
| 3 | L3₹4.1 L+₹31,912 (8.46%)Rejected-AOC NO 22 KUNNIJI NAGAR 1ST STREET EAST TAMBARAM CHENNAI 600 059 TAMIL NADU | CHENNAI | CHENNAI | TAMIL NADU | 600059 | L3 | Rejected-AOC L1 being accepted | |
| 4 | L4₹4.6 L+₹86,682 (23.0%)Rejected-AOC PLOT NO 15 JAYASURIYA STREET GANGAI NAGAR KALLIKUPPAM AMBATTUR CHENNAI 600053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | L4 | Rejected-AOC L1 being accepted |
Tender Value
₹4 L
EMD Value
₹8,000
Closing Date
4 Sept 2024, 6:00 pmClosed
CWE NAVY CHENNAI
Commander Works Engineers Navy Military Engineer Services Fort St George Rajaji Salai Chennai600 009
82606 COMPREHENSIVE MAINTENANCE OF DG SETS AT 2N DET UNDER AGE(I) (NAVY) CHENNAI
2024_MES_652131_3
CWE/NAVY/CHN/82606/E8 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Chennai
As per NIT
8 documents required · 8 mandatory
₹500
AGE I Navy Chennai
₹8,000
Yes
26 Sept 2024
11 Jul 2024
6 Sept 2024
11 Jul 2024
4 Sept 2024
18 Jul 2024
11 Jul 2024 - 15 Jul 2024
Amount
SCHEDULE 'A' PART-I [ E/M WORKS]
Comprehensive maintenance of DG set (No 1 &2) 62.5 KVA installed at 2N DET Vellachi including attending to jobs as mentioned under item No.2 to 2.16 here in complete all as specified and as directed.LOC 2 N DET- 02 NOS, Existing DG -02 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out A checks as detailed below.
Checking the fan belt and adjusting tension
Checking the fuel and oil filter
Checking the air filter including cleaning and refixing
Checking of FIP oil level
Tightening the base bolts and nuts
Checking the coupling bolts and adjustment checking the self starter and Dynamo
Checking the battery distilled water levels and topping upto the required level.
Checking the panels (Manual as well as AMF) attached to the DG set for loose connections, defects if any in the panel Board and replacement of spares all as directed.
Checking the anti vibration mounting and adjusting the bolt.
Checking the radiator and radiator hose and arresting leak if any
Checking the engine oil level and topping upto the required level
NOTES:- (i) Control switches , MCCB's, contactors, multi display meters , Engine control unit shall be out of scope of the item of work and the rate quoted shall be exlusive for servicing/ maintenance of the above item of work.
(ii) Servicing of DG set alongwith connected Alternator and Panel Board including 'A' check of the Engine shall be carried out once in every month (Except during the month when 'B' check is carried out) as directed by the Engineer-in-Charge and the Contractor shall carry out periodical inspections during the maintenenace period and shall be responsible for the smooth functioning of the DG set for a period of 30 days from the date of service and shall also attend all the maintenence / breakdown repairs as and when required in that period except in case of major repairs.
(iii) Spare parts required for replacement during the maintenance period shall be measured and paid separately at supply only rates and cost of labour for fixing these spares shall be deemed to be inluded in the rate quoted .
(iv) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item.
(v) List of checks to be carriedout under 'A' check is attached to the Particular specifications.
Comprehensive maintenance of DG set 500 KVA installed at SMU 2 N DET including attending to jobs as mentioned under item No.2.01 to 2.16 here in complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out A checks as detailed above.
Maintanance and servicing of following Diesel Generator sets by carrying out routine 'B' check of the engine including items covered in 'A' check complete for smooth functiuning all as per manufacturer's instructions and as directed for 62.5 KVA installed at 2 N DET . Existing DG -02 No Make: Kirloskar Note: Quoted Rates are deemed to be included for carrying out B checks as under.
NOTES:- (i) Control switches , MCCB's, contactors, multi display meters , Engine control unit shall be out of scope of the item of work and the rate quoted shall be exlusive for servicing/ maintenance of the above item of work.
(ii) 'B' check shall be carried out once in every six months or 250 hours of running of DG Set whichever is earlier. Servicing of DG Set alonwith connected Alternator and Panel Board including items covered in 'A' check of the Engine shall also be carried out in that month as directed by the Engineer-in-charge and the Contractor shall carry out periodical inspections during the maintenance period and he shall be responsible for the smooth functioning of the DG Set for a period of 30 days from the date of service and shall also attend all the maintenance / breakdown repairs as and when required in that period except in case of Major repairs.
(iii) Spare parts , engine oil and radiator coolant oil required during the maintenance period shall be measured and paid seperatly at supply only rates and cost of labour for fixing these spares/filling of oils shall be deemed to be included in the rate quoted for this item.
(iv) Cost of all consumables, diesel / oil filters etc., required during the maintenance period shall be deemed to be included in the rate quoted for this item.
(v) List of checks to be carriedout under 'B' check is attached to the Particular specifications.
Comprehensive maintenance of DG set 500 KVA installed at SMU 2N Det including attending to jobs as mentioned under item No.4.01 to 4.05 here in before complete all as specified and as directed. Existing DG -01 No Make: Greaves Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Checking the tappet clearance and adjustment of valve including replacement of tappet gasket for following DG Sets :-
DG Set of capacity 62.5 KVA
DG Set of capacity 500 KVA.
Supply only fuel filter pre and secondary including rubber gasket for following DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set)
DG Set of capacity 62.5 KVA
DG Set of capacity500 KVA.
Supply only lube oil filter including rubber gasket for following DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set)
DG Set of capacity 62.5 KVA
DG Set of capacity 500 KVA.
Supply only air filter element including rubber gasket for following DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set )
DG Set of capacity 62.5 KVA
DG Set of capacity 500 KVA.
Supply only fan belt of existing size for following DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set)
DG Set of capacity 62.5 KVA
DG Set of capacity 500 KVA.
Supply only Radiator hose with clip of existing size for following DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set)
DG Set of capacity 62.5 KVA
DG Set of capacity 500 KVA.
Supply only rubber coupling of existing size for DG sets of capacity 62.5 KVA (Cost of replacement deemed to be included in the maintenance part of the DG set)
Supply and toping up the following items for the DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set)
Engine oil 20 W 40
Distilled water
Battery acid
Coolant
Benzo bolt with washer
Jubilee clamp for fuel pipe
Fuel Flexible pipe with brass or GM adaptor
Oil Flexible pipe with brass or GM adaptor
Flexible reinforced pressure pipe 3/8" dia.
Flexible reinforced pressure pipe 1/2" dia.
Flexible reinforced pressure pipe 1" dia.
Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifold for DG Set of capacity 62.5 KVA including removing of existing asbestos rope or any other type of insulation.
Supply and fixing of Expansion bellow for exhaust manifold for DG Set of capacity 62.5 KVA including removing of existing complete all as specified and directed
Draining the engine oil from sump removing the tank cover cleaning the sludge and refixing the same including replacement sump gasket and filling oil for the following Gen sets as per manufactures instructions
DG Set of capacity 62.5 KVA
DG Set of capacity 500 KVA.
Dismantling the fuel pump from the Engine, transportng to the service center and complete servicing and overhauling of the pump including replacement of service kit ,element, delivery valve, plunger, copper washer etc all as required including re-calibration, refixing and testing complete.
DG Set of capacity 62.5 KVA
DG Set of capacity 500 KVA.
Dismantling the water pump from the Engine and supply and fixing new water pump of existing size and testing complete.
DG Set of capacity 62.5 KVA
DG Set of capacity 500 KVA.
Dismantling the fuel pump from the Engine and supply and fixing new fuel pump of existing size and testing complete.
DG Set of capacity 62.5 KVA
DG Set of capacity 500 KVA.
Draining out the diesel tank, cleaning / washing out the sludge and re-filling with diesel for following DG set:-
DG Set of capacity 62.5 KVA
DG Set of capacity 500 KVA.
Taking down radiator, servicing, cleaning of with suitable reagent, washing thoroughly,arresting leakage if any by welding / brazing and refixing the same (Necessary coolant and distilled water required will be measured and paid seperately .
DG Set of capacity 62.5 KVA
DG Set of capacity 500 KVA.
Removing and replacing of Fuel injector pipe for following DG set
DG Set of capacity 62.5 KVA
DG Set of capacity 320 KVA.
Heating and varnishing of alternator for following DG set
DG Set of capacity 62.5 KVA
DG Set of capacity 500 KVA.
Supply and replacement of anti vibration mounting pad for DG Set of capacity 62.5 KVA including removing of existing .
Supply and replacement of the following items for DG set any capacity
Replacement of AVR Suitable for 62.5 KVA Alternators
Replacement of AVR Suitable for 500 KVA Alternators
Removing dismantling and overhauling of 12 volt starter motor, replacement of armature coil, field coil, bush bearing etc to make the starter motor serviceable complete all as specified and as directed.
Spray painting of diesel generating set of capacity 62.5 to 125 KVA with with acoustic enclosure one coat of synthetic enamel paint including writing of SM/MES No on engine and alternator, body colour shall be apple green, black for foundation base frame, red for all guards all as specified and as directed.
Spray painting of diesel generating set of capacity 500 KVA open type with one coat of synthetic enamel paint including writing of SM/MES No on engine and alternator, body colour shall be apple green,black for foundation base frame, red for all guards for all as directed.
Removing and replacing the old unserviceable lead acid battery of size 12 Volt , 130 AH of reputed make including charging and shifting & depositing old battery to MES all as specified as directed.
Removing and replacing the old unserviceable lead acid battery of size 12 Volt , 180 AH of reputed make including charging and shifting & depositing old battery to MES all as specified as directed.
M & L for PCC (1:3:6) type C2 (using 40mm graded crusehd stone aggregate ) as in foundation/Copping of pole including necessary form work complete all as specified and directed.
SJM CONSTRUCTIONS (BID ID -3079889)
Sri Sankar Enterprises (BID ID -3083021)
Banyan Engineers and Contractors (BID ID -3080652)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .