| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Air Conditioning Equipment Supply, installation, testing and commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled outdoor units suitable for Cooling, having all hermetically sealed inverter type multiple scroll compressors, minimum two compressors, microprocessor based controller, top discharge type condensing units complete with indoor and outdoor units with ,interconnecting refrigerant piping, full charge of refrigerant gas (R-410A) & oil, vibration isolators , internal control cabling and fittings complete as required and Outdoor unit connecting kit etc as per details given inspecifications and having following items. The outdoor units shall be suitable for 3 phase, 415V+10%, 50Hz AC supply and indoor shall be suitable for Single phase 220-240V, 50 Hz AC supply. The unit shall deliver the rated capacity at AHRI Conditions and work even at 52°C ambient temperature without tripping. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. Charges for Loading, unloading & shiftting of all outdoor units to Terrace is included in this item. Outdoor Units Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling. The modular VRV equipment, based on inverter technology and comprising multiple modules, should feature a 100% inverter-type hermetically sealed Inverter Scroll compressor with a 8-pole motor, minimum two compressors for above 14 HP modules. The outdoor unit must be factory-assembled, housed in a durable, weatherproof casing made from rust-proofed mild steel panels with a baked enamel finish. The VRV/VRF system should include automatic refrigerant charging and periodic leakage detection, ensuring efficient operation. It must have an outdoor fan capable of maintaining an external static pressure of at least 75 Pa. The electrical control box, rated IP-55, should house a PCB, while the outdoor fan motor should have an IP-44 rating for enhanced protection against foreign particles and environmental conditions. The unit should be designed to adjust the evaporative temperature within the range of 3°C to 11°C, tailored to individual building and climate requirements for enhanced comfort and energy efficiency, utilizing free-phase technology. The VRV system should incorporate intelligent technology to dynamically adjust the speed of the indoor fan, compressor, and outdoor fan based on operating load and external temperature, optimizing efficiency. To ensure seamless operation and ease of maintenance, the compressor and VRV outdoor unit should be of the same make. The system should also support multi-site control via a single monitoring device from the same OEM brand and allow integration with other building equipment for centralized monitoring and management. The unit shall deliver the rated capacity at AHRI Conditions and work even at 52°C ambient temperature without tripping. The Indian Seasonal Energy Efficiency Ratio (ISEER) and COP @ 50% is 10.35. COP @100% is 3.35 shall not be less than of : ISEER value to be not less than 8.38 Note: INSIDE DESIGN CONDITION (Min temperature 22.0 Deg C and maximum temperature 25.0 Deg C, RH should be 50 % +/- 10 %. | |||||
| 1.01 | 20HP | 10 | Each | - | - |
| 2Design, manufacturing, supply, installation , testing & commiissioning of following air cooling by variable refrigerant volume modular type indoor units comprising of EEV & all accessories as per the specifications. The indoor units shall be suitable to work on cooling mode having four directional air flow DX split type Indoor Air Conditioning Units of following capacity suitable for mounting inside false ceiling, each comprising of cooling coil,blower with multi speed motor, electronic expansion valve, supply & return air grilles,filter, insulated connection of refrigerant circuit, provision for fresh air intake ducting, condensate water drain pump with electronic level sensor, including wireless remote controller etc. The indoor units shall be suitable for operation on 220 ±6% volts, 50Hz, 1 phase AC power supply. Ductable indoor units shall be suitable to handle extent of ductwork and dehumidified air quantity and the indoor units shall be of following capacities. All Indoor Units shall have inbuilt Drain Pumps. All the indoor units shall be compatible to work with VRV / VRF type condensing unit. | |||||
| 2.01 | 8 TR High Static Ductable Unit | 17 | Each | - | - |
| 2.02 | 4.5 TR 4-way CASSETTE UNIT | 1 | Each | - | - |
| 3 | SITC for Stylish Wired Madoka Remotes for Ductable and Cassette. | 18 | Each | - | - |
| 4 | SITC of DGT Joints for Connectng ODUs with Copper Pipe and again with IDUs | 40 | Each | - | - |
| 5 | SITC of Centralised Controller with Itouch controller to control all system at One Place and compatible to BMS. | 1 | Each | - | - |
| 6 | Supply, Installation, Testing & Commissioning of Y Joints copper fittings to be provided in refrigerant pipe line all as per specified and directed by Engr-in-charge.. | 18 | Each | - | - |
| 7 | Supply, Installation, Testing and Commissioning of Loading, Unloading, Ligting, Shifting of ODUS and IDUs. | 18 | Lot | - | - |