Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAccepted-AOC 4C 1 KESHAR VIHAR NEAR NSF INTER COLLEGE BALAJI PURAM SHAHGANJ AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | L1 | Accepted-AOC The L1 bidder is techno-commercially eligible and the rate quoted is reasonable and justified, which has been accepted by the Competent Authority, NK Area. | |
| 2 | L2₹2.7 L+₹3,617.42 (1.37%)Rejected-Finance AT DAKRA DIST RANCHI | DAKRA | RANCHI | JHARKHAND | L2 | Rejected-Finance L2 | |
| 3 | L3₹2.7 L+₹10,852.26 (4.11%)Rejected-Finance AT RAY COLLIERY POST CHURI DIST RANCHI 829209 | HAZARIBAGH | JHARKHAND | 829209 | L3 | Rejected-Finance L3 |
Tender Value
₹2.8 L
EMD Value
₹3,600
Closing Date
30 May 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO EnM NK
GM Office, NK Area
Partial diversion cum rearrangement of 6.6kV OHL along the main haul road and its junction in view to maintain safe ground clearance and safe pass way for HEMMs at Quarry No. 01 under Purnadih OCP, NK Area
2022_CCL_244141_1
GM (NK)/EnM/e-NIT/2022-23/10
Open Tender
Electrical and Maintenance Works
Item Rate
25 days
Purnadih OCP, NK Area
As per NIT
2 documents required · 2 mandatory
₹3,600
29 Jun 2022
18 May 2022
1 Jun 2022
19 May 2022
30 May 2022
19 May 2022
19 May 2022 - 26 May 2022
120 days
Amount
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required. Above 10.00 Metre and upto 12.00 Metre.
Supply and erection of stay set complete (galvanized) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle (20 mm x 60 cm), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Erection of all aluminum conductor of 7/1.96 mm to 7/3.10 mm diameter and above including binding etc as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 6.6kV/11 KV overhead line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm MS flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/fittings, bolts nuts and washer etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 6.6KV/11KV/22KV/33KV OH Lines as required.
Erection of pole top / straight two wire/ V shape two wire, angle iron / channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required.
Supplying and erection of a set of cross bracing FRL same work for 11 KV over head line double pole structure having four members fabricated out of 50mm x 50mm x 6mm angle iron to form a rectangle of minimum size 1400 mm width x 2500 mm height, complete with 50 mm x 6mm MS Flats iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts etc. (as per drawing) and painting with primer and finish paint ,as required.
Supplying and Erection of 11 KV disc insulator for 6.6KV/11 KV overhead lines with galvanized insulator fittings, ball and socket type and complete with galvanized strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of 6.6KV/11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Erection of disc / pin insulator for 6.6 KV/ 11 KV over head lines as required.
Supply of 8 / 6 SWG G.I. wire.
Erection of G.I. Wire No. 8 SWG including binding etc. as required.
Erection of cradle Guard as required.
Dismantling of pole / street light standard / strut embedded in cement concrete foundation etc as required.
Dismantling of over head lines comprising of copper / aluminium over head conductor, G.I. wire, cross arms, insulators etc as required.
Total impact of GST for the purpose of CTC
M/S MEHTA ELECTRONICS
M/S M. S. Construction
stage.html
html • 0.04 MB
techsummary_252203.pdf
PDF • 0.22 MB
finsummary_252203.pdf
PDF • 1.17 MB
AOC_10.pdf
PDF • 2.14 MB
finance_252203.pdf
PDF • 0.22 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .