| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 CrAccepted-AOC | ₹5.9 Cr Quoted ₹6.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹6.7 Cr+₹30.6 L (4.76%)Rejected-Finance N A | NA | NA | 121004 | ₹6.7 Cr+₹30.6 L (4.76%) | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical 12 B NIKKA SINGH COLONY RAM TIRATH ROAD AMRITSAR PUNJAB | - | - | Rejected-Technical Bid non-responsive |
Tender Value
₹4.8 Cr
EMD Value
₹9.5 L
Closing Date
13 Feb 2023, 11:00 amClosed
Executive Engineer
SPK dam and HR div no 2 shahpurkandi township
CONSTRUCTION OF BRIDGE AT RD 1135 MTR OVER BALANCE PORTION OF RAVI CANAL J and K SIDE
2022_WR_94301_2
03/2022
National Competitive Bid
Civil Works - Bridges
Item Rate
240 days
Near village basantpur lakhnpur thein road
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹9.5 L
Shahpurkandi Township Pathankot
3 May 2023
26 Dec 2022
13 Feb 2023
26 Dec 2022
13 Feb 2023
26 Dec 2022
4 Jan 2023
Amount
Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m including Loading+Unloading and total carriage upto 1000m ( Katcha) dumped suitable manner as per the satisfaction of the engineer.
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 25 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
Plain/Reinforced cement concrete in sub- structure complete as per drawing and Technical Specifications.PCC Grade M15, Height upto 5m including centering/ shuttering .
Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M-20 linning of Cup shape canal,Using Batching Plant, Transit Mixer and Concrete Pump, Height upto 5m including centering/shuttering.
Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M-35,Using Batching Plant, Transit Mixer and Concrete Pump, Height upto 5m including centering/shuttering.
Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M-35,Using Batching Plant, Transit Mixer and Concrete Pump, Height upto 5m to 10m including centering/shuttering.
Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M-35,Using Batching Plant, Transit Mixer and Concrete Pump, Height above 10m including centering/shuttering.
Plain/Reinforced cement concrete in super-structure complete as per drawing and Technical Specifications RCC Grade M-30,Using Batching Plant, Transit Mixer and Concrete Pump, Height upto 5m including centering/shuttering.
Plain/Reinforced cement concrete in super-structure complete as per drawing and Technical Specifications RCC Grade M-40,Using Batching Plant, Transit Mixer and Concrete Pump, Height upto 5m including centering/shuttering.
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia PVC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Rehandling , Screening of the excavated material to get the material having sizes not more than 150mm , loading , transporting & placing the screened material on embankments in the layers not exceeding 250 mm thick in the Compacted RBM filling area & suitably compacted to achieve minimum relative density of not less than 70% including Katcha as per instructions of the Engineer . Complete in all respects.
Construction of a metalled road 3.0 m wide on the inspection bank of Ravi Canal under the bridge at RD 1135m including all leads & lifts for all materials required for the road work strictly following the specification given as under as per direction of the Engineer, Complete as per technical Clause 406 , 502 , 503 , 504 & 508 of MORT& H Specifications respectively , complete in all respects..
Drainage Spouts complete as per drawing no. SD/205 and Technical specification with 0.6 meter long GI 100 mm dia drainage GI light grade pipe (For Bridges)
Providing and laying a burried expansion joint, expansion gap being 20 mm, covered with 12 mm thick, 200 mm wide galvanised weldable structural steel plate as per IS: 2062, placed symmetrical to centre line of the joint, resting freely over the top surface of the deck concrete, welding of 8 mm dia. 100 mm long galvanised nails spaced 300 mm c/c along the centre line of the plate, all as specified in clause 2604.
Supplying, fitting and placing HYSD Fe 500 bar reinforcement in sub/super-structure complete as per drawing and Technical Specifications.
Providing/Fixing in position the 100 mm thick POT-PTFE tye bearing plates/bearing mechanism including design complete up to the satisfaction of the engineer.
BALRAJ SINGH CONTRACTOR
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .