Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.3 LAccepted-AOC | 1 | Accepted-AOC Being lowest tenderer | |
| 2 | 2₹14.0 L+₹33,308.25 (2.44%)Rejected-AOC | 2 | Rejected-AOC 2nd | |
| 3 | 3₹15.0 L+₹1.3 L (9.59%)Rejected-AOC | 3 | Rejected-AOC 3rd | |
| 4 | 4₹15.1 L+₹1.4 L (10.4%)Rejected-AOC H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | 4 | Rejected-AOC 4th | |
| 5 | 5₹17.1 L+₹3.5 L (25.6%)Rejected-AOC | 5 | Rejected-AOC 5th |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
9 May 2020, 6:00 pmClosed
GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
Repair/replacement/maint of existing unserviceable LED post of lanterns, DG sets and connected underground cable with other miscellaneous works at AF Stn Najafgarh under GE (AF) Tughlakabad
2020_MES_327670_1
GE/TKD/NAJ EM/TOKEN-24/2019-20
Open Tender
Civil Works - Others
Item Rate
330 days
GE AF TUGHLAKABAD
MES contractor enlisted as Class E category b(i) having deposited Standing Security of Rs. 50000 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
8 documents required · 8 mandatory
₹500
Yes
GE AF TUGHLAKABAD
₹38,000
Yes
18 Sept 2020
22 Feb 2020
12 May 2020
6 Mar 2020
9 May 2020
6 Mar 2020
24 Feb 2020 - 6 Mar 2020
Amount
Taking out old unserviceable post light fitting of any capacity any make any type duly disconnecting all electrical connections complete all as specified and directed by Engr-in-charge.
Taking out old unserviceable bollard light fitting of any capacity any make any type duly disconnecting all electrical connections complete all as specified and directed by Engr-in-charge.
S&F LED post light 30 watt made in die cast aluminium body and with clear toughened glass diffuser and IP-65 Protection complete including necessary connection complete all as specified and directed by Engr-in-charge. Make: Cat No HLPT-04-30-CW of Halonix/Cat No LPTO-40-CDL of Crompton/Cat No CORALPT 25W LED757 PSYMPTOC of Havells
S&F LED post light 40 watt made in die cast aluminium body and with clear toughened glass diffuser and IP-65 Protection complete including necessary connection complete all as specified and directed by Engr-in-charge. Make: Cat No HLPT-04-40-CW of Halonix/Cat No LPTO-40-CDL of Crompton/Cat No CORALPT 35W LED757 PSYMPTOC of Havells
S&F LED based bollard 10 Watt with aluminium extruded housing with glare free opal diffuser IP 65 protection complete including necessary connection complete all as specified and directed by Engr-in-charge. Make: Cat No HLOB-02-10-WW of Halonix/Cat No LBLSR-10-WW of Crompton/Cat No BAMBOOL8WLED757 PSYMTOPCM of Havells
Dismantling the starting system of 250 KVA DG set including necessary wires and supply and fix starting system of maint free lead acid battery 12 V, 180 AH 02 Nos with copper terminal cable of 25 Sqmm single core approx length 1.5 mtr each for negative and positive terminal and 0.5 mtr for inter connection including necessary brush terminals complete of the DG set including commissioning, testing complete all as specified and directed by Engr-in-charge. Make: Cat No 131360923 of Exide/Cat No HC180D04R of Amaron/Cat No XL8000T of Okaya
Dismantling the starting system of 125 KVA DG sets including necessary wires and supply and fix starting system of maint free lead acid battery 12 V 160 AH 01 No, with copper terminal cable of 16 Sqmm single core approx length 1.5 Mtr each for negative and positive terminal including necessary bush terminals complete of the DG set including testing and commissioning complete all as specified and directed by Engr-in-charge.
Taking out self starter of 12/24 volt from the DG Set of capacity 250,125&40 KVA, transportation to workshop opening/ disconnecting all internal connection, cleaning the same taking out burnt armature, segregation serviceable parts for re-use, rewinding of armature with existing size of copper wire. Reassembling the same with replacement of carbon bush 01 Set, Beadex pinion 01 No, Half clutch assembly 01 No, Field coil 01 No, solenoid switch 01 No, commitator 01 No, fixing the self starter on the engine at site commissioning, testing complete all as specified and directed by Engr-in-charge.
Taking out the lubricating oil from the existing DG Set of any capacities and supply & filling the lubricating oil of grade 20W40 complete all as specified and directed by Engr-in-charge.
Supply, filling and top up of coolant in the DG sets of any capacity and any make complete all as specified and directed by Engr-in-charge.
Supply and replace the following parts from the diesel engine of capacity 125 KVA DG Set 440 volt 3 phase, 4 wire 50 Hz AC complete all as specified and directed by Engr-in-charge. Existing Make of Diesel Engine - Kirloskar :-
Element of fuel filter with 'O' ring gasket
Element of oil filter with 'O' ring
Fan belt off suitable size.
Hose pipe complete set.
Air cleaner filter
Supply and replace the following parts from the diesel engine of capacity 250 KVA DG Set 440 Volts 3 phase, 4 wire 50 Hz AC complete all as specified and directed by Engr-in-charge. Existing Make of Diesel Engine - Kirloskar :-
Element of fuel filter with 'O' ring gasket
Element of oil filter with 'O' ring
Fan belt off suitable size.
Hose pipe complete set.
Air cleaner filter
Supply and replace the following parts from the diesel engine of capacity 40 KVA DG Set 440 Volts 3 phase, 4 wire 50 Hz AC complete all as specified and directed by Engr-in-charge. Existing Make of Diesel Engine - Kirloskar:-
Element of fuel filter with 'O' ring gasket
Element of oil filter with 'O' ring
Fan belt off suitable size.
Hose pipe complete set.
Air cleaner filter
Battery charger
Detecting the fault by fault with locator machine of any size and type in HT/LT cable in 12 BRD including necessary excavation, jointing by the skill electrician, filling of soil and make good the disturbed surface complete all as specified and directed by Engr-in-charge. Note: Necessary jointing material shall be measured and paid separately in respective item.
S&F chequered rubber matting black colour of 11 KV rating of 25 mm thickness complete all as specified and directed by Engr-in-charge.
M&L for spray painting to the LT panel board with two coats of synthetic enamel paint of high glow 1st grade including preparation /cleaning of old steel surfaces over 10 cm width or girth complete all as specified and directed by Engr-in-charge. Note: Approximate area of surface 8 Sqm of each panel board.
M&L for painting the electrical equipments, steel sections, rolling shutters etc with one coat of synthetic enamel paint of high glow paint including preparation/cleaning of the old steel surfaces over 10 cm width or girth complete all as specified and directed by Engr-in-charge.
Taking down the unserviceable SMC kiosk pole box and S&F of non transparent looping SMC kiosk pole box single phase of size 150 x 100 x 75 mm made out of engineering plastic one piece moulding grey colour with hold fast including 2 Nos aluminium strips 30 Amps of required size fixed on unbreakable insulator and one NO single pole MCB 6 Amps, ‘C’ curve complete all as specified and directed by Engr-in-charge.
Taking out unserviceable MCCB's of any type any capacity by disconnecting all the electrical connection from the panel board / wall /FPB complete all as specified and directed by Engr-in-charge.
S&F MCCBs including necessary fitting arrangement and testing of the following sizes complete all as specified and directed by Engr-in-charge.
63 Amps 3 Pole breaking capacity 16 KA
100 Amps 3 Pole breaking capacity 16 KA
160 Amps 3 Pole breaking capacity 36 KA
250 Amps 34Pole breaking capacity 36 KA
400 Amps 34Pole breaking capacity 36 KA
S&F 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection one twin core cable flat or circular of size 06 Sqmm to be connected to the existing box / Main switches complete all as specified and directed by Engr-in-charge.
S&F 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection one twin core cable flat or circular of size 10 Sqmm to be connected to the existing box / Main switches complete all as specified and directed by Engr-in-charge. Note for sch item Nos 21 & 22: Necessary excavation if any required shall be measured and paid separately.
Dismantling of automatic power factor capacitor panel from main line and opening the panel for repair/ maint of the system and cleaning the contacts with CRC chemical and replacement of the following items, assembling the same after repair / maint and testing for smooth functioning complete all as specified and directed by Engr-in-charge. Note: Spare parts required for replacement will be measured and paid separately in respective items.
Supply only power factor correction capacitor 50 KVr 3 Phase, 440 Volt as per IS 13340:1993. Make: Cat No LTBCH350B2 of L&T/Cat No QHKTCB5050XO of Havells
Supply only Power factor correction capacitor 25 KVr 3 Phase 440 Volt as per IS 13340:1993. Make: Cat No LTBCD325 of L&T/Cat No QHKTCB5025XO of Havells
Supply only Power factor correction capacitor 15 KVr 3 Phase 440 Volt as per IS 13340:1993. Make: Cat No LTBCD315 of L&T/Cat No QHKTCB5015XO of Havells
Supply only Power factor correction capacitor 10 KVr 3 Phase 440 Volt as per IS 13340:1993. Make: Cat No LTCCD310 of L&T/Cat No QHKTCB5015XO of Havells
Supply only Automatic power factor relay type 1143. Make: Cat No CSPF-100 of C&S/Cat No MRPM 14000000 of L&T
Supply only Power contactor 3 Phase 50 Amps. Make: Cat No MNX50 of L&T/Cat No TC1D5011E of C&S/Cat No LC1D50A of Schneider
Supply only Power contactor 3 Phase 95 Amps. Make: Cat No MNX90 of L&T/Cat No TC1D9511E of C&S/Cat No LC1D95A of Schneider
M&L in replacement of Earthing complete with galvanised steel earth plate electrode, 600x600x6mm thick, buried directly in ground vertically to depth not less than 1.5 meters below normal ground level, connected to galvanised iron earthing strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, CGI watering pipe 20mm bore light grade with funnel and wire mesh, PCC chamber in cement concrete 1:3:6 type c1, 80mm thick pre-cast RCC 1:2:4, type B-1 cover reinforced earth plate surrounded by alternate layers of packed charcoal, salt oacked which shall not be less than 15cm in all side of earth plate complete all as shown in electrical plate No 3 of MES schedule Part-I complete all as specified and directed by Engr-in-charge.
Supply and jointing the outdoor cable end terminal joint heat shrinkable type joint complete suitable for aluminium conductor cable of size 2/4 Core upto 16 Sqmm complete all as specified and directed by Engr-in-charge. Make: Cat No XSE-01 of Denson/Cat No RPGEPKT0003 of Raychem/Cat No MHI/OX1.1KV (HESL-4C) of 3M
Ditto- All as per srl item No 32 but for cable of size 25 Sqmm 3½ Core to 50 Sqmm 3½ Core. Make: Cat No XSE-02 of Denson/Cat No RPGEPKT0019 of Raychem/Cat No MHI/OX1.1KV(HESL-4C) of 3M
S&F On-Load Change over switch with advance neutral, front operated with sheet steel enclosure, 415 Volt, AC 50 Hz 320 Amp- 4 Pole complete all as specified and directed by Engr-in-charge. Make: Cat No CO3204PEAY of HPL/Cat No ISCNFE0320 of Standard/Cat No 1HCNFE0320 of Havells
S&F On-Load Cange over switch with advance neutral, front operated with sheet steel enclosure, 415 Volt, AC 50 Hz 400 Amp- 4 Pole complete all as specified and directed by Engr-in-charge. Make: Cat No CO4004PEAY of HPL/Cat No ISCNFE0400 of Standard/Cat No 1HCNFE0400 of Havells
S&F Off load Change over switch side handle with sheet enclosure, 415 Volt, AC 50 Hz 320 Amp-4 Pole complete all as specified and directed by Engr-in-charge. Make: Cat No FS520AFBSE of HPL/Cat No ISCFFE0320 of Standard/Cat No 1HBFFE0320 of Havells
S&F Off load Change over switch side handle with sheet enclosure, 415 Volt, AC 50 Hz 400 Amp-4 Pole complete all as specified and directed by Engr-in-charge. Make: Cat No FS400AFBSE of HPL/Cat No ISCFFE0400 of Standard/Cat No 1HBFFE0400 of Havells
M&L for PCC 1:2:4 type B1 using 20 mm grade stone aggregate as in copping to the electric pole including necessary form work complete all as specified and directed by Engr-in-charge.
Excavation in trenches in soft/loose soil, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete all as specified and directed by Engr-in-charge.
M&L for sand cushioning in trenches for protection of LT underground cable including watering and consolidation all as per SSR Part-I complete all as specified and directed by Engr-in-charge. Note: Punned thickness shall be measured for payment purpose.
Supply and laying well burnt sub class ‘B’ bricks, locally available of size 23x11.5x7.5 CM in trenches for protection of the underground cable complete all as specified and directed by Engr-in-charge.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point complete all as specified and directed by Engr-in-charge.
Returning filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engr-in-charge.
M&L complete for drilling the hole under hard standing /road for laying of the pipe for protection of cable etc by means of manually by drilling and without disturbing the top surface and making good the disturbed surface complete all as specified and directed by Engr-in-charge.
Supply and laying the GI pipe light grade of 40 mm bore complete all as specified and directed by Engr-in-charge.
S&F street light feeder pillar box made out off MS sheet 3.15 mm thick with MS angle iron frame of size 40x40x6mm outdoor type front door opening with locking arrangement slanting roof and size of panel /feeder pillar box is 0.6mx0.45m and 0.35 m without legs including necessary PCC cutting and fixing with PCC 1:3:6 of size 0.3mx0.3mx0.2m for 04 Nos legs including necessary insulators and 04 Nos copper bus bar of size 30mmx5mm capacity, provn of inlet and outlet cables with glands and earth connection lead etc complete and connection of all incoming and outgoing cable using aluminium terminal sockets/lugs duly crimpled and necessary two coats of paints with approved colour and grade of first quality synthetic enameled paint over a coat of red oxide primer including necessary preparation of surfaces all as specified and testing complete of the following :- (i) S&F MCCB 4 pole415 volts 125 Amps 16 KA -01 No (ii) S&F modular indicator lamp LED type -01 set (R,B,Y) (iii) S&F timer switch type Alpharex 3D -21. Make: Astro Legrand Cat No-412654 -01 No (iv) S&F 40 Amps TP power contractor. Make: Legrand Cat No-412549 -01 No (v) S&F 32 Amps TPN MCB -01 No (vi) S&F 6-32 Amps SP MCB -06. (vii) S&F single phase preventer -01 No
Taking out old serviceable/unserviceable underground cable of following sizes from excavated trenches/pipes/pole complete. Note: Earth work and segregating cable cover shall be measured and paid separately.
16 Sqmm 4 core
35 Sqmm 3.5 core
Supply and lay or fixing or passing through pipe cable XLPE (FRLS) with aluminium conductor with heavy duty stranded1100 volts size of 16 Sqmm 4 Core. Note:- XLPE insulated PVC sheathing (heavy duty) armoured cable with aluminium conductor for working pressure up to and including 1100 volts to IS-7098 (Part-I) for PVC insulated cables with following features (a) Cable shall have fire retarded low smoke (FRLS) compound added to it in the out sheathing as per IEC 754(part-I) IEC-60332 part-2 IFEE 383 ASTM 2x43 and ASTM 2X63 flame retardant compound (PR) as per EIC specification. (b) Inner sheathing shall be of extruded PVC. (c) Heat resisting PVC shall also be added to extrude inner and outer sheathing. (d) Cable shall also be supplied with sequences hall marking at every meter as the outer sheathing.
Contd sl item No 48.00: (e) Ultra violet radiation resistances compounded comprising ton ASTMG-53. (f) Anti rodent and ant termite compound added (g) PVC compounds of various grades as IS-5831 (h) compaction conductors shall be shaped and arrangement for the same with be on the cable. Note:- (i) Each cable shall be tested for all applicable routine tests as per IS-5831,IS-7098 BS-6746,BS-5467 and IEC 60502 and test reports shall be provided to GE. (ii) Type test as per relevant specification shall produce to GE.
Ditto- All as per item No 48.0 & 48.1 but size of cable 35 Sqmm 3.5 core.
Note: The amount of Rs 38,758.00 against schedule of credit given on Tender Serial Page No 36 shall be deducted from the total amount quoted by the contractor against BOQ while deriving the contract sum for acceptance.
PARKASH ENTERPRISES
M/s Prakash Enterprises
J.P. Enterprises
M/s R P Enterprises
Parveen Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .