| Sl No | Description | Qty | Unit | Perennial Contractors Pvt. Ltd. L3 | Saraswati Electricals & Contractors L2 | Shiva Electricals Company L1 |
|---|---|---|---|---|---|---|
| 1.00fo|qr forj.k [k.M & nknjh ds {ks=kUrxZr okMZ ua0&5] nkSyrjke dkWyksuh esa Jh uhjt 'kekZ ds edku ls Jh jfoUnz HkkVh ds edku rd yEcs Lisu ds chp iksy yxkus ,oa ttZj rkj dks ,y0Vh0,0ch0 dsfcy@rkj cnyus dk dk;Za ,oa xzke vkuUniqj esa fHk[kkjh ds edku] futw dk edku] c`tiky ds edku ls nso flag ds edku rd iksy ,oa dsfcy Mkyus dk dk;Z ,oa xzke dSejkyk pØlSu iqj esa Vh0 IokWbUV eSu jksM yqgkjksa okys jkLrs ij iksy ,oa dsfcy dk dk;Z | ||||||
| 2.00Safe Cartage of following centralised stock material from any of the Store Center of PVVNL Discom to work site including Loading from Store and safe unloading at site for Item No. 3 to 10 | ||||||
| 3.00 | AB CABLE 3X95 SQMM | 1 | Mtr | 10 ₹10,600 Lowest | 10 ₹10,600 Lowest | 10 ₹10,600 Lowest |
| 4.00 | PCC POLE | 1 | Nos | 1,000 ₹15,000 | 1,000 ₹15,000 | 650 ₹9,750 Lowest |
| 5.00 | PIN INSULATOR | 1 | Nos | 5 ₹300 Lowest | 5 ₹300 Lowest | 5 ₹300 Lowest |
| 6.00 | DISC INSULATOR | 1 | Nos | 5 ₹150 Lowest | 5 ₹150 Lowest | 5 ₹150 Lowest |
| 7.00 | WEASAL CONDUCTOR | 1 | Mtr | 2 ₹300 Lowest | 2 ₹300 Lowest | 5 ₹750 |
| 8.00 | Dropper Channel | 1 | Nos | 5 ₹25 Lowest | 5 ₹25 Lowest | 15 ₹75 |
| 9.00 | T Channel 125x65x1300 mm | 1 | Nos | 200 ₹400 | 200 ₹400 | 15 ₹30 Lowest |
| 10.00 | Top Channel | 1 | Nos | 200 ₹1,000 | 200 ₹1,000 | 15 ₹75 Lowest |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
27 Sept 2025, 12:00 pmClosed
Superintending Engineer
Office of the S.E., EUDC-II, Sec-18 (Ansal) Noida
Work No. 16 related to the item of strengthening of LT line in the area of EUDC-II, Noida under Business Plan 2025-26.
2025_PVVNL_1071447_1
E-Tender No. 35/2025-26, EUDC-II, Noida
Open Tender
Electrical Works
Item Rate
45 days
Office of the S.E., EUDC-II, Sec-18 (Ansal) Noida
Attached in DOC
2 documents required · 2 mandatory
₹5,900
S.E., EUDC-II, Noida.
₹1.9 L
8 Oct 2025
5 Sept 2025
27 Sept 2025
5 Sept 2025
27 Sept 2025
5 Sept 2025
Amount
fo|qr forj.k [k.M & nknjh ds {ks=kUrxZr okMZ ua0&5] nkSyrjke dkWyksuh esa Jh uhjt 'kekZ ds edku ls Jh jfoUnz HkkVh ds edku rd yEcs Lisu ds chp iksy yxkus ,oa ttZj rkj dks ,y0Vh0,0ch0 dsfcy@rkj cnyus dk dk;Za ,oa xzke vkuUniqj esa fHk[kkjh ds edku] futw dk edku] c`tiky ds edku ls nso flag ds edku rd iksy ,oa dsfcy Mkyus dk dk;Z ,oa xzke dSejkyk pØlSu iqj esa Vh0 IokWbUV eSu jksM yqgkjksa okys jkLrs ij iksy ,oa dsfcy dk dk;Z
Safe Cartage of following centralised stock material from any of the Store Center of PVVNL Discom to work site including Loading from Store and safe unloading at site for Item No. 3 to 10
AB CABLE 3X95 SQMM
PCC POLE
PIN INSULATOR
DISC INSULATOR
WEASAL CONDUCTOR
Dropper Channel
T Channel 125x65x1300 mm
Top Channel
Errection of above Centralised material and Supply and errection of the below De-Centralised material for completing the works as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. Single Pole (a) PCC 8.5 Mtr Long Pole.
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) 11M Long ST/PCC Pole and 8.5 Mtr Long PCC Pole
Laying, Sagging and Re-Sagging of AB Cable 3x95sqmm at different locations of T/F as per site requirement.
Laying and Fixing of ACSR Weasel conductor for Jumpering as per site requirement.
FIXING OF PIN INSULATOR WITH PIN AS PER SITE REQUIREMENT.
FIXING OF DISC. INSULATOR WITH FITTING AS PER SITE REQUIREMENT.
FIXING OF DROPPER CHANNEL AS PER SITE REQUIREMENT.
FIXING OF T CHANNEL AS PER SITE REQUIREMENT.
FIXING OF TOP CHANNEL AS PER SITE REQUIREMENT.
Providing and Fixing of Clamps for LT T off with Bolts & Nut as per site requirement.
Providing and Fixing of Holding Clamps as per site requirement.
Providing and Fixing of Suspention Clamp with 1 Hook as per site requirement.
Providing and Fixing of Dead & Clamp with 1 Hook as per site requirement.
Providing and Fixing of Peircing Clamp as per site requirement.
Providing and Fixing of All. Lug 120 Sq mm as per site requirement.
Supply & Fixing of 3 Phase Distribution Box with Pad Lock under EUDD 3 Noida
Supply of PVVNL GTP Approved 3 Phase Distribution Box and Fixing the above Box at Pole as per site requirement with complete connections and work in all respect.
Supply and fixing of best quality LT Piercing connector 50 Sq. mm for above Distribution Box.
Supply and fixing of best quality HOLDING Clamp for 3 phase Distribution Box WTH NUT & BOLTS FOR HANGING OF DISTRIBUTION BOX AT POLE.
Supply PVVNL approved lead 1x16 Sq mm for Connections with complete work in all respect as per site requirement.
Supply & Fixing of best quality PAD LOCK WITH KEY for 3 Phase Distribution Box.
Dismentaling of old and Damaged Distribution Box from site and safe carriage of its from site to any store of PVVNL Discom including loading and unloading both ends.
Supply & Fixing of 3 Phase Distribution Box with Pad Lock under EDD DADRI
Supply of PVVNL GTP Approved 3 Phase Distribution Box and Fixing the above Box at Pole as per site requirement with complete connections and work in all respect.
Supply and fixing of best quality LT Piercing connector 50 Sq. mm for above Distribution Box.
Supply and fixing of best quality HOLDING Clamp for 3 phase Distribution Box WTH NUT & BOLTS FOR HANGING OF DISTRIBUTION BOX AT POLE.
Supply PVVNL approved lead 1x16 Sq mm for Connections with complete work in all respect as per site requirement.
Supply & Fixing of best quality PAD LOCK WITH KEY for 3 Phase Distribution Box.
Dismentaling of old and Damaged Distribution Box from site and safe carriage of its from site to any store of PVVNL Discom including loading and unloading both ends.
Supply & Fixing of 3 Phase Distribution Box with Pad Lock under EDD JEWAR
Supply of PVVNL GTP Approved 3 Phase Distribution Box and Fixing the above Box at Pole as per site requirement with complete connections and work in all respect.
Supply and fixing of best quality LT Piercing connector 50 Sq. mm for above Distribution Box.
Supply and fixing of best quality HOLDING Clamp for 3 phase Distribution Box WTH NUT & BOLTS FOR HANGING OF DISTRIBUTION BOX AT POLE.
Supply PVVNL approved lead 1x16 Sq mm for Connections with complete work in all respect as per site requirement.
Supply & Fixing of best quality PAD LOCK WITH KEY for 3 Phase Distribution Box.
Dismentaling of old and Damaged Distribution Box from site and safe carriage of its from site to any store of PVVNL Discom including loading and unloading both ends.
Saraswati Electricals & Contractors (BID ID -5560528)
Perennial Contractors Pvt. Ltd. (BID ID -5567288)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .