Loading…
Loading…
Tender Value
₹57.5 L
EMD Value
₹57,500
Closing Date
22 Jun 2026, 3:00 pm
The Commissioner
Commissioner, Harur Municipality, Harur
CONSTRUCTION OF 5 TPD MICRO COMPOST CENTRE AT MAVERIPATTI COMPOST YARD IN HARUR MUNICIPALITY
2026_MAWS_679616_1
1227/2025/E1
Open Tender
Civil Works
Harur Municipality
CONSTRUCTION OF 5 TPD MICRO COMPOST CENTRE AT MAVERIPATTI COMPOST YARD IN HARUR MUNICIPALITY
5 documents required · 5 mandatory
₹0
₹57,500
Harur Municipality
5 Jun 2026
5 Jun 2026
22 Jun 2026
5 Jun 2026
22 Jun 2026
5 Jun 2026
9 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water wherever necessary refilling the sides of foundation with excavated soil other than sand in layers of 15cm thick well rammed and cleaning and levelling the site etc.,complete | 156 | M3 | - | - | BI01010001010000000000000515BI0100001126 |
| 1.01 | Plinth Beam short wall | 12 | M3 | - | - | BI01010001010000000000000515BI0100001127 |
| 2 | Supplying and filling in foundation and basement with filling sand in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. | 12.5 | M3 | - | - | BI01010001010000000000000515BI0100001128 |
| 3 | Plain Cement concrete 1:4:8 (one cement, four sand, eight aggregate) using 40mm gauge hard broken granite stone jelly for foundation including dewatering if found necessary and laid in layers of not more than 15cm thick and compacted,etc., complete complying with standard specification. | 26 | M3 | - | - | BI01010001010000000000000515BI0100001129 |
| 4 | Supplying and filling in foundation and basement with Well Gravel in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. | 287 | M3 | - | - | BI01010001010000000000000515BI0100001130 |
| 5 | Providing and laying, spreading and compacting graded stone aggregate to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage to mixed material by tipper to site laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achive the desired density complete as per clasue 406 of MORTH specifications. | 46 | M3 | - | - | BI01010001010000000000000515BI0100001131 |
| 6Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation | ||||||
| 6.01 | a) Without Strutting | 95 | M2 | - | - | BI01010001010000000000000515BI0100001133 |
| 6.02 | b) With Strutting | 69.5 | M2 | - | - | BI01010001010000000000000515BI0100001134 |
| 7 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. (No separate payment will be made by the Department for the excess usage of materials) - Upto Basement | 41.25 | M3 | - | - | BI01010001010000000000000515BI0100001135 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.42 MB
Tendernotice_2.pdf
PDF • 1.05 MB
BOQ_816523.xls
BOQ • 0.25 MB
Biddocument.pdf
Tender Documents • 1.03 MB
Download all tender documents and submit your bid