Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹1.1 CrRejected-Finance | ₹1.1 Cr | L2 | Rejected-Finance Other than lowest bidder. |
| 3 | L3₹1.1 CrRejected-Finance | ₹1.1 Cr | L3 | Rejected-Finance Other than lowest bidder. |
| 4 | L4₹1.2 CrRejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹1.2 Cr | L4 | Rejected-Finance Other than lowest bidder. |
| 5 | L5₹1.2 CrRejected-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹1.2 Cr | L5 | Rejected-Finance Other than lowest bidder. |
| Sl No | Description | Qty | Unit | KULBHUSHAN AGGARWAL L2 | V K Sales and Construction Co L7 | Sarbat Construction Co L1 | vijay builders L5 | ASIA ENTERPRISES L8 | PROACH ASSOCIATES BUILDERS & ENGINEERS L3 | Ashoka Engineers L6 | ANIKET TRADERS L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor,11000 volts grade, of size 3 core 95 sq mm complete all as specified and as directed. | 2,411 | RM | 1,025 ₹24.7 L | 1,462 ₹35.2 L | 1,400 ₹33.8 L | 1,050 ₹25.3 L | 1,350 ₹32.5 L | 1,067 ₹25.7 L | 1,267 ₹30.5 L | 1,180 ₹28.4 L |
| 2.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4.0 core complete all as specified and as directed. | 780 | RM | 275 ₹2.1 L | 330 ₹2.6 L | 220 ₹1.7 L | 280 ₹2.2 L | 350 ₹2.7 L | 242 ₹1.9 L | 360 ₹2.8 L | 275 ₹2.1 L |
| 3.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and as directed. | 2,132 | RM | 235 ₹5.0 L | 370 ₹7.9 L | 250 ₹5.3 L | 320 ₹6.8 L | 450 ₹9.6 L | 295 ₹6.3 L | 400 ₹8.5 L | 305 ₹6.5 L |
| 4.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and as directed. | 160 | RM | 600 ₹96,000 | 764 ₹1.2 L | 450 ₹72,000 | 580 ₹92,800 | 650 ₹1.0 L | 540 ₹86,400 | 671 ₹1.1 L | 615 ₹98,400 |
| 5.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and as directed. | 1,260 | RM | 535 ₹6.7 L | 848 ₹10.7 L | 580 ₹7.3 L | 730 ₹9.2 L | 950 ₹12.0 L | 709 ₹8.9 L | 824 ₹10.4 L | 692 ₹8.7 L |
| 6.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and as directed. | 170 | RM | 925 ₹1.6 L | 1,210 ₹2.1 L | 790 ₹1.3 L | 930 ₹1.6 L | 1,250 ₹2.1 L | 876 ₹1.5 L | 1,024 ₹1.7 L | 912 ₹1.6 L |
| 7.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core complete all as specified and as directed. | 730 | RM | 835 ₹6.1 L | 1,245 ₹9.1 L | 940 ₹6.9 L | 1,080 ₹7.9 L | 1,450 ₹10.6 L | 965 ₹7.0 L | 1,136 ₹8.3 L | 1,080 ₹7.9 L |
| 8.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core complete all as specified and as directed. | 400 | RM | 1,100 ₹4.4 L | 1,576 ₹6.3 L | 1,180 ₹4.7 L | 1,050 ₹4.2 L | 1,600 ₹6.4 L | 1,298 ₹5.2 L | 1,500 ₹6 L | 1,301 ₹5.2 L |
| 9.00 | Material and Labours for shifting of Existing transformer 200 KVA from Main Power House Miran Sahib to 162 INF BDE Genrator Room with disconnecting the transformer indoor /out door from HT / LT side at site all the connected cables and earthing strips carefully for re-use and placing in position including installation testing and commissoning as per site requirement and re-connect the same alongwith its accessories and made functional Included 2.8 Mtr x 2.8 Mtre x 1.2 Mtr PCC Foundation complete all as specified and as directed. | 1 | Each Job | 10,000 ₹10,000 | 40,000 ₹40,000 | 30,000 ₹30,000 | 1,80,000 ₹1.8 L | 50,000 ₹50,000 | 20,000 ₹20,000 | 55,000 ₹55,000 | 80,000 ₹80,000 |
| 10.00 | Design, Supply, Erection, Testing and Commissioning of 11 KV, 630A, STC 21KA for 3sec, SF6 insulated, Manual, Outdoor, Non-extensible RMU , type tested in line with latest IEC standards. The RMU shall be suitable for operations at a height up to 1000 meters above sea level and at 40 degree ambient temperature without any derating. The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure. The RMU tank shall provide full insulation, making the switchgear insensitive to the environment with degrees of protection of IP67 . The switchgear operating mechanism shall have an IP2X protection and cable chamber shall have IP3X. Accidental overpressure due to an internal arc is limited by the opening of the safety valve, at the bottom of the metal enclosure, away from the operator. An operator situated in front, lateral (A-FLR 21kA – 1sec, downwards exhaust for tank and 0.2sec for cable compartment and 0.2sec. for breaker) of the RMU switchboard during an internal fault will not be exposed to the effects of arcing. Internal Arc Type Test Report for IAC AFL R21 kA for 1 sec for both tank & cable box should have been for minimum 3 way / 3 Function RMU, min. 40 nos. of dead short circuit operation at full load. Plug in type of extensibility must be provided and coupling busbar should not be exposed to air to avoid oxidation of busbars. Extension of cubicle should only require 450mm to handle and the gap between the coupled RMU’s must be within 10mm. All operations shall be from front of the RMU, including access to cable bushings. Cable bushings along the sides or the rear of the RMU are not acceptable.further manufacturer should ensure that their engineer should be at customer site for the supervision of commissioning of RMU. | 2 | Each Job | 9,15,000 ₹18.3 L | 10,10,000 ₹20.2 L | 11,40,000 ₹22.8 L | 8,50,000 ₹17 L | 15,00,000 ₹30 L | 9,98,000 ₹20.0 L | 10,88,255 ₹21.8 L | 9,92,000 ₹19.8 L |
Updated dates
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
23 Apr 2026, 6:00 pmClosed
Col Amit Bhardwaj
HQ CWE Jammu PIN-180003
SPECIAL REPAIR TO OVERHEAD LINE TO UNDERGROUND HT AND LT CABLE INF BRIGADE FAMILY QUARTER AND OFFICE AREA AT MIRAN SAHIB MIL STN UNDER GE JAMMU
2026_MES_756902_1
CWE/JP-97/2025-26
Open Tender
Civil Works - Others
270 days
GE Jammu
As Per Tender
9 documents required · 9 mandatory
₹1,000
Yes
GE Jammu
₹2.1 L
Yes
19 May 2026
19 Mar 2026
25 Apr 2026
19 Mar 2026
23 Apr 2026
9 Apr 2026
19 Mar 2026 - 21 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor,11000 volts grade, of size 3 core 95 sq mm complete all as specified and as directed. | |||||
| 2Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4.0 core complete all as specified and as directed. | |||||
| 3Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and as directed. | |||||
| 4Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and as directed. | |||||
| 5Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and as directed. | |||||
| 6Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and as directed. | |||||
| 7Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core complete all as specified and as directed. | |||||
| 8Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core complete all as specified and as directed. | |||||
| 9Material and Labours for shifting of Existing transformer 200 KVA from Main Power House Miran Sahib to 162 INF BDE Genrator Room with disconnecting the transformer indoor /out door from HT / LT side at site all the connected cables and earthing strips carefully for re-use and placing in position including installation testing and commissoning as per site requirement and re-connect the same alongwith its accessories and made functional Included 2.8 Mtr x 2.8 Mtre x 1.2 Mtr PCC Foundation complete all as specified and as directed. | |||||
| 10Design, Supply, Erection, Testing and Commissioning of 11 KV, 630A, STC 21KA for 3sec, SF6 insulated, Manual, Outdoor, Non-extensible RMU , type tested in line with latest IEC standards. The RMU shall be suitable for operations at a height up to 1000 meters above sea level and at 40 degree ambient temperature without any derating. The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure. The RMU tank shall provide full insulation, making the switchgear insensitive to the environment with degrees of protection of IP67 . The switchgear operating mechanism shall have an IP2X protection and cable chamber shall have IP3X. Accidental overpressure due to an internal arc is limited by the opening of the safety valve, at the bottom of the metal enclosure, away from the operator. An operator situated in front, lateral (A-FLR 21kA – 1sec, downwards exhaust for tank and 0.2sec for cable compartment and 0.2sec. for breaker) of the RMU switchboard during an internal fault will not be exposed to the effects of arcing. Internal Arc Type Test Report for IAC AFL R21 kA for 1 sec for both tank & cable box should have been for minimum 3 way / 3 Function RMU, min. 40 nos. of dead short circuit operation at full load. Plug in type of extensibility must be provided and coupling busbar should not be exposed to air to avoid oxidation of busbars. Extension of cubicle should only require 450mm to handle and the gap between the coupled RMU’s must be within 10mm. All operations shall be from front of the RMU, including access to cable bushings. Cable bushings along the sides or the rear of the RMU are not acceptable.further manufacturer should ensure that their engineer should be at customer site for the supervision of commissioning of RMU. | |||||
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
tender97_merged.pdf
Tender Documents • 1.56 MB
BOQ_847838.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid