| 1 | L1₹200.7 CrAccepted-AOC 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹200.7 Cr | L1 | Accepted-AOC L1 Accepted |
| 2 | L2₹207.2 CrRejected-Finance 3RD FLOOR PLANT 11 ALTERNATE MOBILE NO 98749 32329 GITESH VERMA AIR CONDITIONER REFRIGERATOR VIKHROLI WEST MUMBAI MAHARASHTRA 400079 | MUMBAI SUBURBAN | MAHARASHTRA | 400079 | ₹207.2 Cr | L2 | Rejected-Finance L2 Rejected |
Tender Value
₹200.7 Cr
EMD Value
₹1.0 Cr
Closing Date
11 Oct 2021, 11:00 amClosed
Executive Engineer Central Mumbai pwd ele Worli Mu
Executive Engineer Central Mumbai pwd ele Worli Mumbai
Supplying, Installation, Testing and Commissioning of Complete Electrical Installation including all building services with necessary allied building works for proposed 2 BasementG10 Storey Super Speciality Hospital 1200 Bedded at Sir JJ Group
2021_PWDM_711892_1
Est no.6160/JJH-1/11/21-22
Open Tender
Electrical Works
730 days
JJ subdivision Byculla Mumbai
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,600
₹1.0 Cr
CE(Ele) office Bandhakam Bhavan
17 Nov 2022
10 Aug 2021
14 Oct 2021
10 Aug 2021
11 Oct 2021
10 Aug 2021
15 Sept 2021
Amount
Supplying, erecting and commissioning of diesel generating set with alternator of 2000 kVA input continuous rating, 3 phase, 415 V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722- 2001 with voltage regulation +/- 5 %. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising of meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level upto 75 dB at 1.0 m, provided with first filling of oil, diesel day tank, exaust piping with support upto the terrace, control cabling etc. and obtaining necessary approval from Electrical inspector / MPCB as per specification.As per specification no. GEN-DG
Supply, Installation, Testing & Commissioning of METER-1 PANEL (FORM4, TYPE6), METER-2 PANEL (FORM4, TYPE6), METER-4 PANEL (FORM4, TYPE6) each with I/C 800A, 4P, 36kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 1000A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 400A, FP, MP, 36kA. MCCB - 4 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supply, Installation, Testing & Commissioning of METER-3 PANEL (FORM4, TYPE6) each with I/C 800A, 4P, 36kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 1000A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 400A, FP, MP, 36kA. MCCB - 4 No O/G 100A, FP, MP, 36kA. MCCB - 1 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supply, Installation, Testing & Commissioning of METER-5 PANEL (FORM4, TYPE6) each with I/C 800A, 4P, 36kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 1000A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 400A, FP, MP, 36kA. MCCB - 2 No O/G 160A, FP, MP, 36kA. MCCB - 1 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supply, Installation, Testing & Commissioning of METER-6 PANEL (FORM4, TYPE6) each with I/C 800A, 4P, 36kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 1000A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 400A, FP, MP, 36kA. MCCB - 3 No O/G 250A, FP, MP, 36kA. MCCB - 1 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supply, Installation, Testing & Commissioning of METER-7 PANEL (FORM4, TYPE6) each with I/C 3200A, 4P, 36kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 4000A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 3200A, 4P, 36kA, EDO, LSIG ACB - 2 No O/G 1600A, 4P, 36kA, EDO, LSIG ACB - 1 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supply, Installation, Testing & Commissioning of METER-8 PANEL (FORM4, TYPE6) each with I/C 800A, 4P, 36kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 1000A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 400A, FP, MP, 36kA. MCCB - 3 No O/G 100A, FP, MP, 36kA. MCCB - 2 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supply, Installation, Testing & Commissioning of METER-9 PANEL (FORM4, TYPE6) each with I/C 1600A, 4P, 36kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 2000A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 800A, 4P, 36kA, EDO, LSIG ACB - 2 No O/G 630A, FP, MP, 36kA. MCCB - 1 No O/G 400A, FP, MP, 36kA. MCCB - 1 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring.
Supply, Installation, Testing & Commissioning of METER-10 PANEL (FORM4, TYPE6) each with I/C 400A, FP, MP, 36kA. MCCB - 2 No with Electrical & Mechanical Interlocking 500A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 250A, FP, MP, 36kA. MCCB - 2 No O/G 100A, FP, MP, 36kA. MCCB - 1 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supply, Installation, Testing & Commissioning of METER-11 PANEL (FORM4, TYPE6) each with I/C 800A, 4P, 36kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 1000A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 400A, FP, MP, 36kA. MCCB - 2 No O/G 250A, FP, MP, 36kA. MCCB - 2 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supply, Installation, Testing & Commissioning of METER-12 PANEL (FORM4, TYPE6) each with I/C 1250A, 4P, 36kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 1600A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 630A, FP, MP, 36kA. MCCB - 2 No O/G 400A, FP, MP, 36kA. MCCB - 1 No O/G 160A, FP, MP, 36kA. MCCB - 2 No O/G 63A, FP, MP, 36kA. MCCB - 2 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supply, Installation, Testing & Commissioning of METER-13 PANEL (FORM4, TYPE6) each with I/C 800A, 4P, 36kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 1000A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 400A, FP, MP, 36kA. MCCB - 4 No O/G 200A, FP, MP, 36kA. MCCB - 1 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supply, Installation, Testing & Commissioning of METER-14 PANEL (FORM4, TYPE6) each with I/C 800A, 4P, 36kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 1000A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 400A, FP, MP, 36kA. MCCB - 3 No O/G 200A, FP, MP, 36kA. MCCB - 1 No O/G 80A, FP, MP, 36kA. MCCB - 1 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supply, Installation, Testing & Commissioning of METER-15 PANEL (FORM4, TYPE6) each with I/C 1000A, 4P, 36kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 1250A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 1000A, 4P, 36kA, EDO, LSIG ACB - 2 No O/G 400A, FP, MP, 36kA. MCCB - 2 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supply, Installation, Testing & Commissioning of METER-16 PANEL (FORM4, TYPE6), METER-20 PANEL (FORM4, TYPE6) each with I/C 1000A, 4P, 36kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 1250A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 1000A, 4P, 36kA, EDO, LSIG ACB - 3 No O/G 630A, FP, MP, 36kA. MCCB - 1 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supply, Installation, Testing & Commissioning of METER-17 PANEL (FORM4, TYPE6) each with I/C 400A, FP, MP, 36kA. MCCB - 2 No with Electrical & Mechanical Interlocking 500A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 250A, FP, MP, 36kA. MCCB - 2 No O/G 160A, FP, MP, 36kA. MCCB - 1 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supply, Installation, Testing & Commissioning of METER-18 PANEL (FORM4, TYPE6) each with I/C 800A, 4P, 36kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 1000A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 400A, FP, MP, 36kA. MCCB - 3 No O/G 200A, FP, MP, 36kA. MCCB - 2 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supply, Installation, Testing & Commissioning of METER-19 PANEL (FORM4, TYPE6) each with I/C 1600A, 4P, 36kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 2000A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 800A, 4P, 36kA, EDO, LSIG ACB - 3 No O/G 400A, FP, MP, 36kA. MCCB - 1 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supply, Installation, Testing & Commissioning of METER-21 PANEL (FORM4, TYPE6) each with I/C 800A, 4P, 36kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 1000A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 250A, FP, MP, 36kA. MCCB - 4 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supply, Installation, Testing & Commissioning of METER-22 PANEL (FORM4, TYPE6) each with I/C 1600A, 4P, 36kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 2000A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 800A, 4P, 36kA, EDO, LSIG ACB - 2 No O/G 630A, FP, MP, 36kA. MCCB - 1 No O/G 63A, FP, MP, 36kA. MCCB - 2 No All incomer shall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring, CT for APFC panel, CT for DG Sync panel. All outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
S u p p l y ing and erecting 35 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection as per specification no CP-ED/APFC (Refer Schedule B in DTP for Detailed Item Description)
S u p p l y ing and erecting 50 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection as per specification no CP-ED/APFC (Refer Schedule B in DTP for Detailed Item Description)
S u p p l y ing and erecting 100 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection as per specification no CP-ED/APFC (Refer Schedule B in DTP for Detailed Item Description)
S u p p l y ing and erecting 150 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection as per specification no CP-ED/APFC (Refer Schedule B in DTP for Detailed Item Description)
S u p p l y ing and erecting 200 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection as per specification no CP-ED/APFC (Refer Schedule B in DTP for Detailed Item Description)
S u p p l y ing and erecting 65 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection.as per specification no CP-ED/APFC. (Refer Schedule B in DTP for Detailed Item Description)
S u p p l y ing and erecting 110 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection as per specification no CP-ED/APFC. (Refer Schedule B in DTP for Detailed Item Description)
S u p p l y ing and erecting 115 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection as per specification no CP-ED/APFC. (Refer Schedule B in DTP for Detailed Item Description)
S u p p l y ing and erecting 155 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection as per specification no CP-ED/APFC. (Refer Schedule B in DTP for Detailed Item Description)
S u p p l y ing and erecting 170 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection as per specification no CP-ED/APFC. (Refer Schedule B in DTP for Detailed Item Description)
S u p p l y ing and erecting 180 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection as per specification no CP-ED/APFC (Refer Schedule B in DTP for Detailed Item Description)
S u p p l y ing and erecting 215 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection as per specification no CP-ED/APFC. (Refer Schedule B in DTP for Detailed Item Description)
S u p p l y ing and erecting 235 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection as per specification no CP-ED/APFC. (Refer Schedule B in DTP for Detailed Item Description)
S u p p l y ing and erecting 635 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection as per specification no CP-ED/APFC (Refer Schedule B in DTP for Detailed Item Description)
OT UPS INPUT PANEL-1 & OT UPS INPUT PANEL-2 (FORM3B, TYPE2) I/C 400A, FP, MP, 25kA. MCCB - 1 No 500A AL. SLEEVED TP+2N BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 250A, FP, MP, 25kA. MCCB - 3 Nos All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. All outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
OT UPS OUTPUT PANEL-1 & OT UPS OUTPUT PANEL-2 (FORM3B, TYPE2) I/C 250A, FP, MP, 25kA. MCCB - 3 Nos 500A AL. SLEEVED TP+2N BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 400A, FP, MP, 25kA. MCCB - 2 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. All outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
OPERATION THEATRE PANEL-1 & OPERATION THEATRE PANEL-2 (FORM3B, TYPE2) I/C 400A, FP, ISOLATOR - 1 No 500A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 3A FP, MP, 25KA. MCCB - 14 No All incomer shall have RYB phase indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
CALORIFIER PANEL (FORM3B, TYPE2) I/C 250A, FP, ISOLATOR - 1 No 320A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 160A FP, MP, 25KA. MCCB - 4 No All incomer shall have RYB phase indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
X-RAY PANEL (FORM3B, TYPE2) I/C 630A, FP, ISOLATOR - 1 No 800A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 100A FP, MP, 25KA. MCCB - 8 No All incomer shall have RYB phase indicator lamp with MCB,Digital MFM compatible for BMS control, CT for metering, control wiring. .(Refer Schedule B in DTP for Detailed Item Description)
EXTERNAL LIGHTING & STAIRCASE LIGHTING PANEL (FORM3B, TYPE2) I/C 160A, FP, ISOLATOR - 1 No 200A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 63A FP, MP, 25KA. MCCB - 6 No All incomer shall have RYB phase indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Future Expansion Panel (FORM3B, TYPE2) I/C 800A, FP, ISOLATOR - 1 No 1000A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 400A FP, MP, 25KA. MCCB - 2 No O/G 160A FP, MP, 25KA. MCCB - 1 No O/G 80A FP, MP, 25KA. MCCB - 3 No O/G 63A FP, MP, 25KA. MCCB - 6 No All incomer shall have RYB phase indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
LIFT NORMAL PANEL ZONE-1 & LIFT NORMAL PANEL ZONE-2 (FORM3B, TYPE2) I/C 160A, FP, ISOLATOR - 1 No 200A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 80A FP,MP, 25KA. MCCB - 10 No All incomer shall have RYB phase indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
STAIRCASE LIGHTING PANEL ZONE-1 & STAIRCASE LIGHTING PANEL ZONE-2 (FORM3B, TYPE2) I/C 40A, FP, ISOLATOR - 1 No 63A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 32A DP MCB 16KA T&M BASED - 8 No All incomer shall have RYB phase indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
MAIN UV LIGTH ZONE-1 PANEL & MAIN UV LIGTH ZONE-1 PANEL ( FORM3B, TYPE2) I/C 80A, FP, ISOLATOR - 1 No 100A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 32A DP MCB 16KA T&M BASED - 15 No All incomer shall have RYB phase indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
MAIN CATH LAB PANEL ( FORM3B, TYPE2) I/C 160A, FP, ISOLATOR - 1 No 200A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 63A FP, MP, 25KA. MCCB - 6 No All incomer shall have RYB phase indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
LIFT EMER PANEL ZONE-1 & LIFT EMER PANEL ZONE-2 ( FORM3B, TYPE2) I/C 160A, FP, ISOLATOR - 1 No 200A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 80A FP, MP, 25KA. MCCB - 6 No All incomer shall have RYB phase indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
TYPICAL ELEVATOR / LIFT PANEL (FORM3B, TYPE2) I/C 80A, FP, ISOLATOR - 1 No 100A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 63A FP RCBO 16KA 300 mA TM BASED - 2 No O/G 25A DP RCBO 16KA 300 mA TM BASED - 5 No All incomer shall have RYB phase indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
EXTERNAL LIGHTING PANEL (FORM3B, TYPE2) I/C 63A, FP, ISOLATOR - 1 No 80A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 25A FP, MP, 16KA. MCCB with contractor & Astro Timer - 6 No All incomer shall have RYB phase indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
PLUMBING PANEL (FORM3B, TYPE2) I/C 200A, FP, ISOLATOR - 1 No 250A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 40A DP, MP, 25KA. MPCB WITH 5.5 HP DOL STARTER - 6 No O/G 25A DP, MP, 25KA. MPCB - 13 No O/G 100A FP, MP, 25KA. MCCB - 2 No O/G 32A FP, MP, 25KA. MCCB - 2 No All incomer shall have RYB phase indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
LBM VENTILATION PANEL ( FORM3B, TYPE2) I/C 400A, FP, ISOLATOR - 1 No 500A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 250A FP, MP, 25KA. MCCB - 3 No O/G 100A FP, MP, 25KA. MCCB - 6 No All incomer shall have RYB phase indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
UBM VENTILATION PANEL ( FORM3B, TYPE2) I/C 400A, FP, ISOLATOR - 1 No 500A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 250A FP, MP, 25KA. MCCB - 3 No O/G 100A FP, MP, 25KA. MCCB - 3 No All incomer shall have RYB phase indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
FIRE PANEL ( FORM3B, TYPE2) I/C 800A, 4P, 25kA, EDO, LSIG ACB - 2 No with Electrical & Mechanical Interlocking 1000A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 200A FP, MP, 25KA. MPCB WITH 100 HP STAR/DELTA STARTER - 9 No All incomer shall have RYB phase indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
ZONE-1 STAIRCASE PRESSURISATION & LIFT WELL PRESSURISATION PANEL ( FORM3B, TYPE2) & ZONE-2 STAIRCASE PRESSURISATION & LIFT WELL PRESSURISATION PANEL ( FORM3B, TYPE2) I/C 400A, FP, ISOLATOR - 1 No 500A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 40A FP, MP, 25KA. MCCB - 38 No All incomer shall have RYB phase indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z1 LBM L&P PANEL (FORM3B, TYPE2) I/C 80A, FP, MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 100A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 40A FP MCB 16KA T&M BASED - 2 No O/G 32A DP MCB 16KA T&M BASED - 2 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z1 UBM L&P PANEL (FORM3B, TYPE2) I/C 80A 4P MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 100A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 40A FP MCB 16KA T&M BASED - 4 No O/G 32A DP MCB 16KA T&M BASED - 3 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z1 GF L&P PANEL (FORM3B, TYPE2) I/C 160A 4P MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 200A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 40A FP MCB 16KA T&M BASED - 9 No O/G 32A DP MCB 16KA T&M BASED - 12 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z1 1F L&P PANEL (FORM3B, TYPE2) I/C 200A 4P MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 250A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 40A FP MCB 16KA T&M BASED - 24 No O/G 32A DP MCB 16KA T&M BASED - 8 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z1 2F L&P PANEL (FORM3B, TYPE2) I/C 250A 4P MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 320A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 40A FP MCB 16KA T&M BASED - 30 No O/G 32A DP MCB 16KA T&M BASED - 4 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z1 3F L&P PANEL (FORM3B, TYPE2) I/C 200A 4P MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 250A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 40A FP MCB 16KA T&M BASED - 21 No O/G 32A DP MCB 16KA T&M BASED - 4 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z1 4F L&P PANEL (FORM3B, TYPE2), Z2 4F L&P PANEL (FORM3B, TYPE2) I/C 80A 4P MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 100A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 40A FP MCB 16KA T&M BASED - 4 No O/G 32A DP MCB 16KA T&M BASED - 4 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z1 5F L&P PANEL (FORM3B, TYPE2) I/C 500A 4P MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 630A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 80A FP MCB 16KA T&M BASED - 2 No O/G 63A FP MCB 16KA T&M BASED - 9 No O/G 40A FP MCB 16KA T&M BASED - 14 No O/G 32A DP MCB 16KA T&M BASED - 6 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z1 6F L&P PANEL (FORM3B, TYPE2) I/C 250A 4P MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 320A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 63A FP MCB 16KA T&M BASED - 1 No O/G 40A FP MCB 16KA T&M BASED - 16 No O/G 32A DP MCB 16KA T&M BASED - 11 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z1 7F L&P PANEL, Z1 8F L&P PANEL, Z1 9F L&P PANEL, Z1 10F L&P PANEL (FORM3B, TYPE2) I/C 250A 4P MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 320A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 63A FP MCB 16KA T&M BASED - 2 No O/G 40A FP MCB 16KA T&M BASED - 13 No O/G 32A DP MCB 16KA T&M BASED - 8 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z2 LBM L&P PANEL (FORM3B, TYPE2) I/C 80A 4P MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 100A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 40A FP MCB 16KA T&M BASED - 13 No O/G 32A DP MCB 16KA T&M BASED - 8 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z2 UBM L&P PANEL (FORM3B, TYPE2) I/C 80A 4P MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 100A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 40A FP MCB 16KA T&M BASED - 19 No O/G 32A DP MCB 16KA T&M BASED - 0 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z2 GF L&P PANEL (FORM3B, TYPE2) I/C 250 A 4P MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 320A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 40A FP MCB 16KA T&M BASED - 25 No O/G 32A DP MCB 16KA T&M BASED - 16 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z2 1F L&P PANEL (FORM3B, TYPE2) I/C 200A 4P MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 250A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 63A FP MCB 16KA T&M BASED - 2 No O/G 40A FP MCB 16KA T&M BASED - 19 No O/G 32A DP MCB 16KA T&M BASED - 9 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z2 2F L&P PANEL (FORM3B, TYPE2) I/C 250A 4P MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 320A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 63A FP MCB 16KA T&M BASED - 1 No O/G 40A FP MCB 16KA T&M BASED - 34 No O/G 32A DP MCB 16KA T&M BASED - 13 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z2 3F L&P PANEL (FORM3B, TYPE2) I/C 250A 4P MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 320A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 40A FP MCB 16KA T&M BASED - 31 No O/G 32A DP MCB 16KA T&M BASED - 6 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z2 5F L&P PANEL (FORM3B, TYPE2) I/C 500A 4P MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 630A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 63A FP MCB 16KA T&M BASED - 7 No O/G 40A FP MCB 16KA T&M BASED - 25 No O/G 32A DP MCB 16KA T&M BASED - 11 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Z2 6F L&P PANEL, Z2 7F L&P PANEL, Z2 8F L&P PANEL, Z2 9F L&P PANEL, Z2 10F L&P PANEL (FORM3B, TYPE2) I/C 250A 4P MP, 16kA. MCCB - 2 No with Electrical & Mechanical Interlocking 320A 4P AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G 80A FP MCB 16KA T&M BASED - 2 No O/G 63A FP MCB 16KA T&M BASED - 4 No O/G 40A FP MCB 16KA T&M BASED - 9 No O/G 32A DP MCB 16KA T&M BASED - 14 No All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control, CT for metering, control wiring. (Refer Schedule B in DTP for Detailed Item Description)
Supplying, installation, testing & commisioning of 40A FP 16KA MP TM MCCB in IP-43 MS enclosure with RYB phase indicator lamp with MCB including iron frame for mounting of MCCB enclosure. MCCbs shall comply with standards IS/IEC 60947-1 & 2. and shall have to provide electric fault trip indication on panel and with thermal magnetic trip unit (with Adjustable Thermal - 0.7 - 1 Ir and Fixed Magnetic). It shall be current limiting type and shall have an encapsulated double break roto design having two fixed contacts, two moving contacts and two arc chutes per pole with Continuous rated Shunt trip coils & common & snap fit accessaries and should be ROHS & WEEE compliant
Supplying, installation, testing & commisioning of 63A FP 16KA MP TM MCCB in IP-43 MS enclosure with RYB phase indicator lamp with MCB including iron frame for mounting of MCCB enclosure. MCCbs shall comply with standards IS/IEC 60947-1 & 2. and shall have to provide electric fault trip indication on panel and with thermal magnetic trip unit (with Adjustable Thermal - 0.7 - 1 Ir and Fixed Magnetic). It shall be current limiting type and shall have an encapsulated double break roto design having two fixed contacts, two moving contacts and two arc chutes per pole with Continuous rated Shunt trip coils & common & snap fit accessaries and should be ROHS & WEEE compliant
Supplying, installation, testing & commisioning of 100A FP 16KA MP TM MCCB in IP-43 MS enclosure with RYB phase indicator lamp with MCB including iron frame for mounting of MCCB enclosure. MCCbs shall comply with standards IS/IEC 60947-1 & 2. and shall have to provide electric fault trip indication on panel and with thermal magnetic trip unit (with Adjustable Thermal - 0.7 - 1 Ir and Fixed Magnetic). It shall be current limiting type and shall have an encapsulated double break roto design having two fixed contacts, two moving contacts and two arc chutes per pole with Continuous rated Shunt trip coils & common & snap fit accessaries and should be ROHS & WEEE compliant
Supplying, installation, testing & commisioning of 160A FP 16KA MP TM MCCB in IP-43 MS enclosure with RYB phase indicator lamp with MCB including iron frame for mounting of MCCB enclosure. MCCbs shall comply with standards IS/IEC 60947-1 & 2. and shall have to provide electric fault trip indication on panel and with thermal magnetic trip unit (with Adjustable Thermal - 0.7 - 1 Ir and Fixed Magnetic). It shall be current limiting type and shall have an encapsulated double break roto design having two fixed contacts, two moving contacts and two arc chutes per pole with Continuous rated Shunt trip coils & common & snap fit accessaries and should be ROHS & WEEE compliant
Supplying, installation, testing & commisioning of 200A FP 16KA MP TM MCCB in IP-43 MS enclosure with RYB phase indicator lamp with MCB including iron frame for mounting of MCCB enclosure. MCCbs shall comply with standards IS/IEC 60947-1 & 2. and shall have to provide electric fault trip indication on panel and with thermal magnetic trip unit (with Adjustable Thermal - 0.7 - 1 Ir and Fixed Magnetic). It shall be current limiting type and shall have an encapsulated double break roto design having two fixed contacts, two moving contacts and two arc chutes per pole with Continuous rated Shunt trip coils & common & snap fit accessaries and should be ROHS & WEEE compliant
Supplying, installation, testing & commisioning of 250A FP 16KA MP TM MCCB in IP-43 MS enclosure with RYB phase indicator lamp with MCB including iron frame for mounting of MCCB enclosure. MCCbs shall comply with standards IS/IEC 60947-1 & 2. and shall have to provide electric fault trip indication on panel and with thermal magnetic trip unit (with Adjustable Thermal - 0.7 - 1 Ir and Fixed Magnetic). It shall be current limiting type and shall have an encapsulated double break roto design having two fixed contacts, two moving contacts and two arc chutes per pole with Continuous rated Shunt trip coils & common & snap fit accessaries and should be ROHS & WEEE compliant
Supplying, installation, testing & commisioning of 200A FP 25KA MP MCCB in IP-43 MS enclosure with RYB phase indicator lamp with MCB including iron frame for mounting of MCCB enclosure. MCCB shall be with microprocessor trip units & shall comply with standards IS/IEC 60947-1 & 2. and shall have to provide electric fault trip indication on panel and with thermal magnetic trip unit (with Adjustable Thermal - 0.7 - 1 Ir and Fixed Magnetic). It shall be current limiting type and shall have an encapsulated double break roto design having two fixed contacts, two moving contacts and two arc chutes per pole with Continuous rated Shunt trip coils & common & snap fit accessaries and should be ROHS & WEEE compliant
Supplying, installation, testing & commisioning of 250A FP 25KA MP MCCB in IP-43 MS enclosure with RYB phase indicator lamp with MCB including iron frame for mounting of MCCB enclosure. MCCB shall be with microprocessor trip units & shall comply with standards IS/IEC 60947-1 & 2. and shall have to provide electric fault trip indication on panel and with thermal magnetic trip unit (with Adjustable Thermal - 0.7 - 1 Ir and Fixed Magnetic). It shall be current limiting type and shall have an encapsulated double break roto design having two fixed contacts, two moving contacts and two arc chutes per pole with Continuous rated Shunt trip coils & common & snap fit accessaries and should be ROHS & WEEE compliant
Supplying, installation, testing & commisioning of 400A FP 25KA MP MCCB in IP-43 MS enclosure with RYB phase indicator lamp with MCB including iron frame for mounting of MCCB enclosure. MCCB shall be with microprocessor trip units & shall comply with standards IS/IEC 60947-1 & 2. and shall have to provide electric fault trip indication on panel and with thermal magnetic trip unit (with Adjustable Thermal - 0.7 - 1 Ir and Fixed Magnetic). It shall be current limiting type and shall have an encapsulated double break roto design having two fixed contacts, two moving contacts and two arc chutes per pole with Continuous rated Shunt trip coils & common & snap fit accessaries and should be ROHS & WEEE compliant
Supplying, installation, testing & commisioning of 400A FP MCCB including MS enclosure and iron frame as isolators. MCCB shall be with microprocessor trip units & shall comply with standards IS/IEC 60947-1 & 2. and shall have to provide electric fault trip indication on panel and with thermal magnetic trip unit (with Adjustable Thermal - 0.7 - 1 Ir and Fixed Magnetic). It shall be current limiting type and shall have an encapsulated double break roto design having two fixed contacts, two moving contacts and two arc chutes per pole with Continuous rated Shunt trip coils & common & snap fit accessaries and should be ROHS & WEEE compliant
Supplying, installation, testing & commisioning of air circuit breaker of 800A, 500V, 4 pole having inbuilt ZSI module with standard accessories enclosed in a IP-43 MS enclosure and iron frame as isolators.The Air circuit breakers (ACB) shall comply with standards IS/IEC 60947-(1 & 2) & IS/IEC 60664-1 & shall have ICS=ICU=ICW for 1 Sec. ACB shall not derate up to 50’C & shall have break time <30ms & shall have 100% rated neutral pole.The provided ACB shall suitable for terminating aluminum bus bars and shall have ROHS & WEEE Certifications
Supplying, installation, testing & commisioning of air circuit breaker of 1000A, 500V, 4 pole with inbuilt ZSI module with standard accessories enclosed in a IP-43 MS enclosure and iron frame as isolators.The Air circuit breakers (ACB) shall comply with standards IS/IEC 60947-(1 & 2) & IS/IEC 60664-1 & shall have ICS=ICU=ICW for 1 Sec. ACB shall not derate up to 50’C & shall have break time <30ms & shall have 100% rated neutral pole.The provided ACB shall suitable for terminating aluminum bus bars and shall have ROHS & WEEE Certifications
Supplying, installation, testing & commisioning of air circuit breaker of 1250A, 500V, 4 pole with inbuilt ZSI module with standard accessories enclosed in a IP-43 MS enclosure and iron frame as isolators.The Air circuit breakers (ACB) shall comply with standards IS/IEC 60947-(1 & 2) & IS/IEC 60664-1 & shall have ICS=ICU=ICW for 1 Sec. ACB shall not derate up to 50’C & shall have break time <30ms & shall have 100% rated neutral pole.The provided ACB shall suitable for terminating aluminum bus bars and shall have ROHS & WEEE Certifications
Supplying, installation, testing & commisioning of air circuit breaker of 1600A, 500V, 4 pole with inbuilt ZSI module with standard accessories enclosed in a IP-43 MS enclosure and iron frame as isolators.The Air circuit breakers (ACB) shall comply with standards IS/IEC 60947-(1 & 2) & IS/IEC 60664-1 & shall have ICS=ICU=ICW for 1 Sec. ACB shall not derate up to 50’C & shall have break time <30ms & shall have 100% rated neutral pole.The provided ACB shall suitable for terminating aluminum bus bars and shall have ROHS & WEEE Certifications
Supplying, installation, testing & commisioning of air circuit breaker of 3200A, 500V, 4 pole with inbuilt ZSI module with standard accessories enclosed in a IP-43 MS enclosure and iron frame as isolators.The Air circuit breakers (ACB) shall comply with standards IS/IEC 60947-(1 & 2) & IS/IEC 60664-1 & shall have ICS=ICU=ICW for 1 Sec. ACB shall not derate up to 50’C & shall have break time <30ms & shall have 100% rated neutral pole.The provided ACB shall suitable for terminating aluminum bus bars and shall have ROHS & WEEE Certifications
Supply, installation, testing and commissioning of Aluminum 400A/630 A 40kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5mm Electro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition
Supply, installation, testing and commissioning of Flange end with Adaptor box, Copper flexibles as per design requirement & site condition suitable for Aluminum 400A/630 A 40kA Sandwich type BBT.
Supply, installation, testing and commissioning of 90 Degree Elbow / T Elbow as per design requirement & site condition suitable for Aluminum 400A/630 A 40kA Sandwich type BBT.
Supply, installation, testing and commissioning of Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 400A/630 A 40kA Sandwich type BBT.
Supply, installation, testing and commissioning of Support hanger as per site condition suitable for vertical Aluminum 400A/630 A 40kA Sandwich type BBT.
Supply, installation, testing and commissioning of Fabrication Support & hardware suitable for Aluminum 400A/630 A 40kA Sandwich type BBT.
Supply, installation, testing and commissioning of Aluminum 800A 40kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5mm Electro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition
Supply, installation, testing and commissioning of Flange end with Adaptor box, Copper flexibles as per design requirement & site condition suitable for Aluminum 800A 40kA Sandwich type BBT.
Supply, installation, testing and commissioning of 90 Degree Elbow / T Elbow as per design requirement & site condition suitable for Aluminum 800A 40kA Sandwich type BBT.
Supply, installation, testing and commissioning of Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 800A 40kA Sandwich type BBT.
Supply, installation, testing and commissioning of Support hanger as per site condition suitable for vertical Aluminum 800A 40kA Sandwich type BBT.
Supply, installation, testing and commissioning of Fabrication Support & hardware suitable for Aluminum 800A 40kA Sandwich type BBT.
Supply, installation, testing and commissioning of Aluminum 1000A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5mm Electro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition
Supply, installation, testing and commissioning of Flange end with Adaptor box, Copper flexibles as per design requirement & site condition suitable for Aluminum 1000A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of 90 Degree Elbow / T Elbow as per design requirement & site condition suitable for Aluminum 1000A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 1000A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Support hanger as per site condition suitable for vertical Aluminum 1000A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Fabrication Support & hardware suitable for Aluminum 1000A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Aluminum 1250A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5mm Electro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition
Supply, installation, testing and commissioning of Flange end with Adaptor box, Copper flexibles as per design requirement & site condition suitable for Aluminum 1250A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of 90 Degree Elbow / T Elbow as per design requirement & site condition suitable for Aluminum 1250A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 1250A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Support hanger as per site condition suitable for vertical Aluminum 1250A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Fabrication Support & hardware suitable for Aluminum 1250A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Aluminum 1600A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5mm Electro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition
Supply, installation, testing and commissioning of Flange end with Adaptor box, Copper flexibles as per design requirement & site condition suitable for Aluminum 1600A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of 90 Degree Elbow / T Elbow as per design requirement & site condition suitable for Aluminum 1600A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Support hanger as per site condition suitable for vertical Aluminum 1600A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Fabrication Support & hardware suitable for Aluminum 1600A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Aluminum 3200A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5mm Electro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers as per design requirement & site condition
Supply, installation, testing and commissioning of Aluminum 3200A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5mm Electro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 65 for outdoor with canopy. The total bus bar assembly & installaion at site must comply Seismic zone 4 or above. Straight length of feeder / plug in type with hanging brackets, end covers as per design requirement & site condition
Supply, installation, testing and commissioning of Flange end with Adaptor box, Copper flexibles as per design requirement & site condition suitable for Aluminum 3200A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of 90 Degree Elbow / T Elbow as per design requirement & site condition suitable for Aluminum 3200A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 3200A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Support hanger as per site condition suitable for vertical Aluminum 3200A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Fabrication Support & hardware suitable for Aluminum 3200A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Tap off box tested as per IEC 61439-6 of 100 A Tap off box (IP-54) made of 1.6mm thick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4P LSI with earthing connection point & safelty interlock
Supply, installation, testing and commissioning of Tap off box tested as per IEC 61439-6 of 160 A Tap off box (IP-54) made of 1.6mm thick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4P LSI with earthing connection point & safelty interlock
Supply, installation, testing and commissioning of Tap off box tested as per IEC 61439-6 of 250 A Tap off box (IP-54) made of 1.6mm thick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4P LSI with earthing connection point & safelty interlock
Supply, installation, testing and commissioning of Tap off box tested as per IEC 61439-6 of 320 A Tap off box (IP-54) made of 1.6mm thick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4P LSI with earthing connection point & safelty interlock
Supply, installation, testing and commissioning of Tap off box tested as per IEC 61439-6 of 500 A Tap off box (IP-54) made of 1.6mm thick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4P LSI with earthing connection point & safelty interlock
Supplying, erecting & terminating XLPE armoured cable 4 core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification No. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification No. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification No. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification No. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 95 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification No. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 120 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification No. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 150 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification No. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 1100 V. 4 core 185 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification No. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4core 240 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification No. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 300 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification No. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4core 400 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification No. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification No. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 3 core 6 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification No. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 3 core 10 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification No. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification No. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification No. CB-LT/CU
Supplying, erecting & terminating of Fire survival XLPE armoured cable 3 core 4 sq. mm. Stranded Copper conductor, 2 Layer of Mica Tape wrapped, XLPE Insulated, Glass Fibre Tape, LSZH (Thermoplastic) Inner sheathed, Single Layer of GI Wire Armour, Overall LSZH (Thermoplastic) sheathed Fire Survival cables as per BS 7846 (CWZ test approved) (950 Degree C for 3 hour) complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe.
Supplying, erecting & terminating of Fire survival XLPE armoured cable 3 core 6 sq. mm. Stranded Copper conductor, 2 Layer of Mica Tape wrapped, XLPE Insulated, Glass Fibre Tape, LSZH (Thermoplastic) Inner sheathed, Single Layer of GI Wire Armour, Overall LSZH (Thermoplastic) sheathed Fire Survival cables as per BS 7846 (CWZ test approved) (950 Degree C for 3 hour) complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe.
Supplying, erecting & terminating of Fire survival XLPE armoured cable 3 core 10 sq. mm. Stranded Copper conductor, 2 Layer of Mica Tape wrapped, XLPE Insulated, Glass Fibre Tape, LSZH (Thermoplastic) Inner sheathed, Single Layer of GI Wire Armour, Overall LSZH (Thermoplastic) sheathed Fire Survival cables as per BS 7846 (CWZ test approved) (950 Degree C for 3 hour) complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe.
Supplying, erecting & terminating of Fire survival XLPE armoured cable 4 core 10 sq. mm. Stranded Copper conductor, 2 Layer of Mica Tape wrapped, XLPE Insulated, Glass Fibre Tape, LSZH (Thermoplastic) Inner sheathed, Single Layer of GI Wire Armour, Overall LSZH (Thermoplastic) sheathed Fire Survival cables as per BS 7846 (CWZ test approved) (950 Degree C for 3 hour) complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe.
Supplying, erecting & terminating of Fire survival XLPE armoured cable 4 core 25 sq. mm. Stranded Copper conductor, 2 Layer of Mica Tape wrapped, XLPE Insulated, Glass Fibre Tape, LSZH (Thermoplastic) Inner sheathed, Single Layer of GI Wire Armour, Overall LSZH (Thermoplastic) sheathed Fire Survival cables as per BS 7846 (CWZ test approved) (950 Degree C for 3 hour) complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe.
Supplying, erecting & terminating of Fire survival XLPE armoured cable 4 core 35 sq. mm. Stranded Copper conductor, 2 Layer of Mica Tape wrapped, XLPE Insulated, Glass Fibre Tape, LSZH (Thermoplastic) Inner sheathed, Single Layer of GI Wire Armour, Overall LSZH (Thermoplastic) sheathed Fire Survival cables as per BS 7846 (CWZ test approved) (950 Degree C for 3 hour) complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe.
Supplying, erecting & terminating of Fire survival XLPE armoured cable 4 core 50 sq. mm. Stranded Copper conductor, 2 Layer of Mica Tape wrapped, XLPE Insulated, Glass Fibre Tape, LSZH (Thermoplastic) Inner sheathed, Single Layer of GI Wire Armour, Overall LSZH (Thermoplastic) sheathed Fire Survival cables as per BS 7846 (CWZ test approved) (950 Degree C for 3 hour) complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe.
Supplying, erecting & terminating of Fire survival XLPE armoured cable 4 core 120 sq. mm. Stranded Copper conductor, 2 Layer of Mica Tape wrapped, XLPE Insulated, Glass Fibre Tape, LSZH (Thermoplastic) Inner sheathed, Single Layer of GI Wire Armour, Overall LSZH (Thermoplastic) sheathed Fire Survival cables as per BS 7846 (CWZ test approved) (950 Degree C for 3 hour) complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe.
Supplying, erecting & terminating of Fire survival XLPE armoured cable 4 core 150 sq. mm. Stranded Copper conductor, 2 Layer of Mica Tape wrapped, XLPE Insulated, Glass Fibre Tape, LSZH (Thermoplastic) Inner sheathed, Single Layer of GI Wire Armour, Overall LSZH (Thermoplastic) sheathed Fire Survival cables as per BS 7846 (CWZ test approved) (950 Degree C for 3 hour) complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe.
Supplying, erecting & terminating of Fire survival XLPE armoured cable 4 core 185 sq. mm. Stranded Copper conductor, 2 Layer of Mica Tape wrapped, XLPE Insulated, Glass Fibre Tape, LSZH (Thermoplastic) Inner sheathed, Single Layer of GI Wire Armour, Overall LSZH (Thermoplastic) sheathed Fire Survival cables as per BS 7846 (CWZ test approved) (950 Degree C for 3 hour) complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe.
Supplying, erecting & terminating of Fire survival XLPE armoured cable 4 core 240 sq. mm. Stranded Copper conductor, 2 Layer of Mica Tape wrapped, XLPE Insulated, Glass Fibre Tape, LSZH (Thermoplastic) Inner sheathed, Single Layer of GI Wire Armour, Overall LSZH (Thermoplastic) sheathed Fire Survival cables as per BS 7846 (CWZ test approved) (950 Degree C for 3 hour) complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe.
Supplying, installing, testing and commissioning of 700 VA digital pure sine wave inverter based on Insulated Gate Bipolar Transistor (IGBT) technology single phase 230V,50 Hz complete as per specification no. AP-INV (Without batteries)
Supplying, installing, testing and commissioning of 900 VA Digital pure sine wave inverter based on Insulated Gate Bipolar Transistor (IGBT) technology single phase 230V,50 Hz complete as per specification no. APINV (Without batteries)
Supplying, installing, testing and commissioning of 1500 VA Digital pure sine wave inverter based on Insulated Gate Bipolar Transistor (IGBT) technology single phase 230V,50 Hz complete as per specification no. APINV (Without batteries)
Supplying, installing, testing and commissioning of 2500 VA Digital pure sine wave inverter based on Insulated Gate Bipolar Transistor (IGBT) technology single phase 230V,50 Hz complete as per specification no. APINV (Without batteries)
Supplying and erecting 12 V/100Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete
Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supply, installation, Testing & commissioning of Smart 30KVA UPS with SMF battery bank for 15 minutes backup. as per IS 13314 & IS 11260 having following capacity & features:- Load 0.8 PF, Full wave / pure sine wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output. UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quoted price shall be inclusive of required rating single core copper conductor cable including terminations,connections of UPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge.
Supply, installation, Testing & commissioning of Smart 160KVA UPS with SMF battery bank for 15 minutes backup. as per IS 13314 & IS 11260 having following capacity & features:- Load 0.8 PF, Full wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output. UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quoted price shall be inclusive of required rating single core copper conductor cable including terminations,connections of UPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. Note:- 1) Standard accessories shall typically include : a) 'Z' section support -30 x 35 mm in size - 312 mm in length - 6 nos. support for one piece ladder of 2.5 m in length each. b) Anchor fastener & nut bolts of adequate size - 16 nos. ( 2 nos. per support) c) Coupler plates with hardware - 70 x 200 x 3 mm thick - 2 nos. for each piece of 2.5 m ladder complete with necessary accessories such as reducer, horizontal elbow & tee, up & down vertical elbow & bend, cross piece complete erected in approved manner. 2) Provision for resting arrangement or support for perforated type cable tray shall be made separately as per iron work Item. 3) Provision of cover for perforated type cable tray shall be made only where it is absolutely necessary and make sure for locking arrangement. 4) Both type of cable trays shall be earthed properly.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. Note:- 1) Standard accessories shall typically include : a) 'Z' section support -30 x 35 mm in size - 312 mm in length - 6 nos. support for one piece ladder of 2.5 m in length each. b) Anchor fastener & nut bolts of adequate size - 16 nos. ( 2 nos. per support) c) Coupler plates with hardware - 70 x 200 x 3 mm thick - 2 nos. for each piece of 2.5 m ladder complete with necessary accessories such as reducer, horizontal elbow & tee, up & down vertical elbow & bend, cross piece complete erected in approved manner. 2) Provision for resting arrangement or support for perforated type cable tray shall be made separately as per iron work Item. 3) Provision of cover for perforated type cable tray shall be made only where it is absolutely necessary and make sure for locking arrangement. 4) Both type of cable trays shall be earthed properly.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. Note:- 1) Standard accessories shall typically include : a) 'Z' section support -30 x 35 mm in size - 312 mm in length - 6 nos. support for one piece ladder of 2.5 m in length each. b) Anchor fastener & nut bolts of adequate size - 16 nos. ( 2 nos. per support) c) Coupler plates with hardware - 70 x 200 x 3 mm thick - 2 nos. for each piece of 2.5 m ladder complete with necessary accessories such as reducer, horizontal elbow & tee, up & down vertical elbow & bend, cross piece complete erected in approved manner. 2) Provision for resting arrangement or support for perforated type cable tray shall be made separately as per iron work Item. 3) Provision of cover for perforated type cable tray shall be made only where it is absolutely necessary and make sure for locking arrangement. 4) Both type of cable trays shall be earthed properly.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 500 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. Note:- 1) Standard accessories shall typically include : a) 'Z' section support -30 x 35 mm in size - 312 mm in length - 6 nos. support for one piece ladder of 2.5 m in length each. b) Anchor fastener & nut bolts of adequate size - 16 nos. ( 2 nos. per support) c) Coupler plates with hardware - 70 x 200 x 3 mm thick - 2 nos. for each piece of 2.5 m ladder complete with necessary accessories such as reducer, horizontal elbow & tee, up & down vertical elbow & bend, cross piece complete erected in approved manner. 2) Provision for resting arrangement or support for perforated type cable tray shall be made separately as per iron work Item. 3) Provision of cover for perforated type cable tray shall be made only where it is absolutely necessary and make sure for locking arrangement. 4) Both type of cable trays shall be earthed properly.
6 WAY SPN DB Supplying and erecting single pole and neutral distribution board (SPNDB) surface/flush mounted with 2 poles for incoming and 6 poles for outgoing SP MCB‟s on iron/ GI frame as per specification no. SW-SWR/MCBDB
12 WAY SPN DB Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with 2 poles for incoming and 10 poles for outgoing SP MCB‟s on iron/ GI frame as per specification no. SW-SWR/MCBDB
16 WAY SPN DB Supplying and erecting single pole and neutral distribution board (SPNDB) surface/flush mounted with 2 poles for incoming and 14 poles for outgoing SP MCB‟s on iron/ GI frame as per specification no. SW-SWR/MCBDB
4 WAY TPN DB Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SPMCB of 12 poles, on iron /GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
8 WAY TPN DB Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SPMCB of 24 poles, on iron/ GI frame/wooden board.(horizontal busbar type) as per specification no. SW-SWR/MCBDB
12 WAY TPN DB Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SPMCB of 36 poles on iron/ GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
16 WAY TPN DB Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SPMCB of 48 poles on iron/ GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
4 WAY VTPN DB Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted SP/TP MCBs of 12 poles/4 ways on iron / GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
8 WAY VTPN DB Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted SP / TP of 24 poles/ 8 ways on iron / GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
12 WAY VTPN DB Supplying & erecting triple pole and neutral distribution board(TPNDB) surface/ flush mounted SP / TP MCB of 36 poles/12ways on iron / GI frame (vertical busbar type) as per specificationno. SW-SWR/MCBDB
Supplying, erecting & marking SPMCB 6A to 32A, C-series (formotor/power) in provided distribution board as per specificationno. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/MCB
Supplying, erecting & marking TPMCB 6 A to 32A in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB
Supplying, fixing and commissioning 2 pole,RCBO (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 6/10/16/20/25A, as per specification no SWRCCB/RCBO
Supplying, fixing and commissioning 2 pole RCBO (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 32A/40A as per specification no SW-RCCB/RCBO
Supplying, fixing and commissioning 2 pole RCBO (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 63A, as per specification no SW-RCCB/RCBO
Supplying, fixing and commissioning 4 pole RCBO ( (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 32A/40A as per specification no SW-RCCB/RCBO
Supplying, fixing and commissioning 4 pole RCBO ( (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 63A as per specification no SW-RCCB/RCBO
Point wiring for light/fan/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ HW. Average Length 6M.
Point wiring for light/fan/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW. Average Length 8M.
Point wiring for light/fan/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW. Average Length 10M.
Secondary point wiring for additional light/ bell point, concealed type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FR/FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
Point wiring for light/fan/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, Controlled by provided MCB, earthing and required accessories as per specification No: WGPW/HW. Average Length 10M.
Point wiring for independent plug in ISI mark HMS PVC conduit with 1.5 sq.mm (2+1E )FR LSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Wiring for plug on board with modular Switch socket concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. Note: Add Rs 57/- for additional two module box with double mounting plate if required.
Supplying and erecting ISI mark modular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background..
Supplying and erecting lumiNous / modular type call bell indicator with plastic body, heavy duty coil and indicator lamp working on 230V A.C. supply with resetting arrangement complete erected on double wooden/ sunmica board
Supplying & erecting mains with 2x1.5 sq.mm. and earth wire 1.5 sq.mm FRLSH PVC copper wire, in HMS PVC conduit min. 20mm dia as per specification No: WG-MA/PC. (Surface Conduit)
Supplying & erecting mains with 2x2.5 sq.mm. and earth wire 1.5 sq.mm FRLSH PVC copper wire in HMS PVC conduit min. 20mm dia. as per specification No: WG-MA/PC. (Surface Conduit)
Supplying & erecting mains with 2x4 sq.mm. and earth wire 2.5 sq.mm FRLSH PVC copper wire in HMS PVC conduit min. 20mm dia, as per specification No: WG-MA/PC. (Surface Conduit)
Supplying & erecting mains with 2x6 sq.mm. and earth wire 4 sq.mm FRLSH PVC copper wire, in HMS PVC conduit min.20mm dia, as per specification No: WG-MA/PC. (Surface Conduit)
Supplying & erecting mains with 2x10 sq.mm. and earth wire 6 sq.mm FRLSH PVC copper wire, in HMS PVC conduit min. 25mm dia, as per specification No: WG-MA/PC. (Surface)
Concealing of provided G.I. pipe/H.G. screwed conduit/PVC pipe in wall/floor/false ceiling complete as per specification No: WG-PW/CW
Supplying and erecting square shaped CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) 600x600mm suitable for 50W with provision for plane front frame with translucent cover fixed to the housing complete for glare free light distribution.
Supplying and erecting CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) square / round shape 24 W with provision for plane front frame with translucent cover fixed to the housing complete.
Supplying and erecting LED square / circular 5 to 8W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED square / circular 16 to 20W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting square / rectangular shaped CRCA /diecast aluminium powder coated housing LED panel (slim edge-lit) light suitable for 30W with provision for planefront frame with translucent cover fixed to the housing complete.
Supplying & erecting LED 18W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic driver complete.
Supplying and erecting square shaped CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) 600x600mm suitable for 24W with provision for plane front frame with translucent cover fixed to the housing complete for glare free light distribution.
Supplying and erecting square shaped CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) 600x600mm suitable for 30W with provision for plane front frame with translucent cover fixed to the housing complete for glare free light distribution.
Supplying and erecting square shaped CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) 600x600mm suitable for 36 W-40W with provision for plane front frame with translucent cover fixed to the housing complete.
Supplying and erecting corridor/passage light fitting (2 feet) including 9W LED lamp, comprises of extruded channel in plastic silver grey colour & with same plastic end cap on provided PVC block / wooden board.
Supplying and erecting LED square / circular 16 to 20W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying & erecting LED 2X20W tube light fitting including LED tube lights with polycarbonate housing, heat sink, integrated HF electronic driver complete.
Supplying and erecting CRCA /die-cast aluminium powder coated housing Bottom Opening Clean Room LED Luminaries 24 W with provision for plane front frame with translucent cover fixed to the housing complete.
Supplying and erecting LED square / circular 13 to 15W down lighter having pressure die-cast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting square / round shaped CRCA /die-cast aluminium powder coated housing LED panel ( slim edge-lit) light suitable for 13W to18W with provision for plane front frame with translucent cover fixed to the housing complete
Supplying & erecting LED 36W tube light fitting including 36W LED lamp with polycarbonate housing, heat sink, integrated HF electronic driver complete.
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying & erecting LED BATTEN 16W tube light fitting with LED lamp with alluminium housing, heat sink, integrated HF electronic driver complete.
Supplying & erecting LED 20W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete.
Supplying and erecting LED square / circular 13 to 15W down lighter having pressure die-cast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED square / circular 13 to 15W down lighter having pressure die-cast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying & erecting LED BATTEN 5W including LED lamp with polycarbonate housing, heat sink, integrated HF electronic driver complete.
Supplying and erecting decorative oval bulk head edge-lit 10W LED luminaire comprising of high brightness LED Fitting on provided PVC block / wooden board.
Supplying and erecting five star rated energy saving Ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification No. FG-FN/CF
Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan.
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia.or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and within any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting „B‟ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Filling the holes and core cut with fire barrier sealants having minimum 3 hours fire rating to provide a tight and dependable seal against fire, smoke, toxic fumes and moisture and finishing in an approved manner etc complete.
Providing Core cut of 50 to 100 mm in Concrete ceiling / slab / column for thickness upto 2 feets in an approved manner etc complete.
Providing Core cut of 150 to 200 mm in Concrete ceiling / slab / column for thickness upto 2 feets in an approved manner etc complete.
Supply and erecting of Occupancy sensor light switch having a coverage of min. 6 metre dia at 3.6 metre with site adjustable off timing and instant ON / OFF.
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification No. EA-EP
Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. Specification No. EA-MOBI
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bitumiNous paint in an approved manner with joints required. As per specification No. EA-EP.
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bitumiNous paint in an approved manner with joints required. As per specification No EA-EP.
Supplying, erecting & terminating XLPE unarmoured cable 1 core 25 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CB-LT/CU (For 30KVA UPS earthing.)
Supplying, erecting & terminating XLPE unarmoured cable 1 core 50 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CB-LT/CU (For 160 KVA UPS earthing.)
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 & CPRI tested having 2 mm thickness upto 3.3 kV
Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm A/F, top 70 mm A/F on provided foundation as per specification no. OHPL/ OPL
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OHPL/ PBKT
Supplying and erecting LED street light fitting 150 W, including lamp, with PF > 0.95, class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification No FG-ODF/FLS-2.
Supplying & erecting water tight terminal box of 1.6 mm (16 gauge) CRCA sheet of size 150 x 100 x 100 mm complete on pole as per specification no. CB-SB with Bakelite connector.
Supplying, erecting & terminating XLPE armoured cable 3 core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supply, Installation, testing & commissioning of Earthing Copper Bar with supports, Earthing test link in 1.6 mm (16 gauge) CRCA sheet Enclosure Box.
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles)
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Constructing masonry Chamber 90x80x100 cm inside, in brick work in cement mortar 1:6 (1 cement : 6 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. The chamber shall be with heavy duty cover.
Supplying and erecting three phase 10 to 60 A net meter DLMS compliance of accuracy class 1.0, 3 x 240V, 50 Hz, with backlit LCD display, optical port and RJ 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh,V, I, kW, 6 months history of energy) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.
Supplying, installing, testing and commissioning of 101 kWp capacity on grid solar power pack with GI mounting structure and inter connecting wires / cables without battery bank SPV modules and solar power conditioning unit of required capacity complete, with 5 years on site performance warrantee. Specification no. ESD-RTONG
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on .provided stand/ wall hook complete
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Supplying, installing, testing and commissioning of UV ligt Fly killer with M.S. body, 2 X 20W tube and approx. area covered: 2000 sq.ft.
Supplying and erecting ISI mark modular safety power strip with one modular switch 16A and three sockets each 13A combination with overload and surge protection unit on double mounting plate, duly erected complete.
Supplying & erecting original 1.25 mm CRCA sheet metal enclosures with 20A, 2 pin plug & earth socket and 20A. 3 pin plug top with 20A/30A single pole MCB complete erected on angle iron/ GI frame.
Supplying, erecting, testing and commissioning selfcontained water cooler 230/250 V 50 cycles nominal cooling capacity of 80 litres/hr and storage capacity 120 litres with partially stainless steel body complete. specification no. AP-WCR/WC
Supplying and erecting ultra violet storage type water purifier ( RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water 7 to 8 litre/min with activated carbon filter and softener operating on 230 V single phase A.C. supply.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation in an approved manner.
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with insulating and non-corrosive bond in an approved manner with required joints As per specification no. EA-EP.
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond in an approved manner with required joints As per specification no. EAEP.
Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. Specification no. EA-MOBI
Supply, Installation, Testing and Commissioning of Microprocessor based required nos. of Intelligent Addressable multi Loop wireless FIRE ALARM PANELS compliant to IS Codes 2175:1988, 11360:1985 ( Both reaffirmed2000) and IS Code2189:1999(Reaffirmed 2004) Total loops shall be as per the no of detector & modules in complete project. PANELS should be modular, expandable, networkable and soft addressable type . The panel shall be able to give pin point location upto 3m radious of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The Fire Alarm Control Panel shall have following features • Microprocessor based wireless intelligent system • Supports multiple wireless fire alarm sensors and devices, •Indicates the status and alarm for supported devices • Works on standard input 230 V AC voltages. • In-built Hooter • In-built Real time Clock (RTC) with battery backup • Minimum Capacity up to 4500 devices per Panel • Event Recording up to 1500 events per Panel • RF Communication using Frequency Modulation • 7 inch Colour Display with touch screen • Works on Frequency: 433.9 MHz, 333 MHz, and 2.36GHz. • Inbuilt IOT gateway for web monitoring • Wi-Fi connectivity
Supplying, Erecting, Testing & Commissioning of rack mount servers suitable for 24x7 operation, one for FDA & other for VES having Cache Memory 15MB, Intel Processor & Chipset, Frequency Xeon 1.9GHz Processor, Internal Memory 16 GB DDR4, 8 DiMM Slots, 2x1TB Hard Drive 8 LFF (3.5inch) Hot Plug SAS/SATA Ethernet Ethernet 1Gb 2-port 36i Adapter with all necessary latest edition upgradable operating systems with SQL server database & softwares necessary for functioning of the FDA with RAID-3 Configuration with wireless keyboard & mouse with all necessary hardware-peripherals & softwares
Supply Installation testing & commissioning of A4 size Colour All-in-One Ink tank Printer supporting Print, Copy and Scan, Print speed up to 24 ppm (black) and 20 ppm (colour) , USB, 1 Host USB, Ethernet, Wi-Fi, 2 RJ-11 modem ports, fully automatic duplex ADF, print resolution black & white 1200 x 1200 , Colour 4800x1200 DPI with connecting USB cable and Power Cable.
Supplying, Erecting, Testing & Commissioning of Wireless Transreciever :- RF Trans-receiver with MESH protocol Two Way Communication Necessary wireless signal transmitter receiver RF Antena with Operating Frequency in 433.92MHz bandwidth +/-50Khz Operating Range up to 2km Alarm - Hooters & Strobe lights 2nos 110db output Hooter with Strobe light for Audio visual indiacations to operator to be installed in CMS
Supplying, Erecting, Testing & Commissioning of IoT Gateway - Hardware having the following features • Microprocessor based monitoring system with ARMv8, 64 bit processor • Inbuilt Real time Clock (RTC) with battery backup • PC based configuration software • Works on power supply Range 12 V to 24 V SMPS (In-built) • Data stored or sent with time stamp • Operating Temperature range -: -10 to 55 C • Wi-Fi / GSM gateway for internet connectivity • 2.4 GHz and 5GHz IEEE 802.11.b/g/n/ac wireless LAN • Quad-Band 850/900/1800/1900 MHz • GPRS multi-slot class 10/8 • SAIC (Single Antenna Interference Cancellation) support • Class 1 (1 W @ 1800/1900MHz) • Control via AT commands (GSM 07.07 ,07.05 and SIMCOM enhanced AT Commands) • Supply voltage range : 3.2 V • Low power consumption: 1.0mA (sleep mode & BS-PA- MFRMS=9) • Operation temperature: -40°C to +85 °C • GPRS class 10: max. 85.6 kbps (downlink)
Supplying, Erecting, Testing & Commissioning of Wireless Addressable Fire Alarm Hooter/Control Panel. • Standalone working in different zones • Uninterrupted communication link with Centralized Monitoring System over RF. • Works on standard input 230 V AC -12/24VDC • Battery backup up to 8 Hrs in case of power failure • RF Communication using Frequency Modulation • Up to 110 DB sounder • Works on Frequency: 433.9 MHz, 333 MHz, and 2.36GHz
Supplying & erecting on line UPS pure sine wave of 6 kVA capacity complete with standard features, along with necessary SMF batteries for 30 mins battery backup, as per specification no. AP-UPS
Supplying, Erecting, Testing & Commissioning wireless addressable programmable optical smoke cum heat detector having inbuilt Trans-receiver two-way communication module with adjustable temperature/smoke sensitivity necessary lithium battery, erected in position with necessary box in an approved manner. the detector having following specs & features Battery :Voltage range 3.6 V/9VDC(Lithium battery) 7.5AH with minimum 7 years of life Operating frequency: 433.93 MHz Ambient temperature range:- -10deg C to +55deg C Sensitivity setting : adjustment with inbuilt DIP Switch Wireless Protocol:- Two Way Mesh /Multi-loop Coverage Area :- 25 sq.mtr Data Transmission for :- a. Smoke b. Temp c. Dust accumulation d. Tamper /Detector Removal e. Low Bat f. Health check Handshaking mode with other detectors in loop Modulation method :- FM Alarm Output:- Inbuilt buzzer Indication :- LED The detector shall be complete with mounting base & accessories suitable for below false ceiling mount.
Supplying, Erecting, Testing & Commissioning wireless addressable programmable optical smoke cum heat detector having inbuilt Trans-receiver two-way communication module with adjustable temperature/smoke sensitivity necessary lithium battery, erected in position with necessary box in an approved manner. the detector having following specs & features • Standalone working in different zones. • Unique embedded addressing method. • Consistent communication with Centralized Monitoring System over RF • Works on standard 9V battery • Very Low standby current in range of 10-30 μA • Optical sensor for smoke detection. • RF Modulation type: Frequency Modulation • Works on Frequency: 433.9 MHz, 333 MHz, and 2.36GHz.
Supply, Installation, Testing and Commissioning of INTRINSICALLY SAFE addressable loop powered smoke detector including mounting base with LED… etc. FOR GAS STORAGE AREA OF HOSPITALS Include Back box for detector above false ceiling. (FOR GAS STORAGE AREA)
Supply, Installation, Testing and Commissioning of addressable Rate of Rise Heat Detector with mounting base. The detector shall have inbuilt isolator. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) The detector shall have operating temperature range from -20 °C to 50 °C. (For Kitchen & Pantry)
Supplying, erecting, testing, commissioning wireless addressable programmable IR 3 -flame or spark detector having inbuilt Trans-receiver two-way communication module with adjustable flame size sensitivity necessary lithium battery, erected in position with necessary box in an approved manner. the detector having following specs & features Battery :Voltage range 3.6 V/9VDC(Lithium battery) 7.5AH with minimum 7 years of life Operating frequency: 433.93 MHz Ambient temperature range:- -10deg C to +55deg C Wireless Protocol:- Two Way Mesh /Multi-loop Sensor type :- Ultraviolet-IR duel sensor Sensitivity Angle :- 120degree Sensivity Range :- 15mm flame size at 3mtr distance Sensitivity setting : adjustment with inbuilt DIP Switch Data Transmission for :- a. flame b. Tamper /Detector Removal c. Low Bat f. Health check Handshaking mode with other detectors in loop Modulation method :- FM Indication :- LED
Supplying, Erecting, Testing & Commissioning wireless addressable programmable optical smoke cum heat detector having inbuilt Trans-receiver two-way communication module with adjustable temperature/smoke sensitivity necessary lithium battery, erected in position with necessary box in an approved manner. the detector having following specs & features • Standalone working in different zones. • Unique embedded addressing method. • Consistent communication with Centralized Monitoring System over RF • Works on standard 9V battery • Very Low standby current in range of 10-30 μA • Optical sensor for smoke detection. • RF Modulation type: Frequency Modulation • Works on Frequency: 433.9 MHz, 333 MHz, and 2.36GHz.
Suppy, Installation,Testing,Commissioning of Conventional smoke projected beam detector with integrated transmitter and reciever with operating range 0 - 125 meters, to be made addressable via input monitor module. (For Double Height Area)
Supply,instalaltion,testing commisssioning of Addressable Module with one input & one output contact. The module shall have inbuilt isolator.
Supply,instalaltion,testing commisssioning of addressable 12 relay output transponder module to take care of 3rd party devices activations like AHU Units/PAVA system integration. The module shall have an inbuilt isolator.
Supply, Installation, Testing and Commissioning of wireless addressable Loop Powered sounder and Visual Alarm Device (VAD) with integrated signaling tones and red light flash for acoustic and optical alarm signaling having the following Features • Standalone working in different zones • Uninterrupted communication link with Centralized Monitoring System over RF. • Works on standard input 230 V AC -12/24VDC • Battery backup up to 8 Hrs in case of power failure • RF Communication using Frequency Modulation • Up to 110 DB sounder • Works on Frequency: 433.9 MHz, 333 MHz, and 2.36GHz
Supplying, Erecting, Testing & Commissioning wireless addressable programable Local Voice Evacuation control Panel (LVEP) having inbuilt Trans-receiver two-way communication module with necessary lithium battery back up the LVEP having following specs & features • Standalone working in different zones • Uninterrupted communication link with Centralized Monitoring System over RF. • Works on standard input 230 V AC -12/24VDC • Battery backup up to 8 Hrs in case of power failure • RF Communication using Frequency Modulation • Up to 110 DB sounder • Works on Frequency: 433.9 MHz, 333 MHz, and 2.36GHz
Supply, Installation, Testing & Commissioning of addressable Multisensor fire detector with integrated optical sensor and heat sensor with enhanced false alarm management. The optical measurement chamber provided with sensor technology using a high-sensitive blue LED (instead of the commonly used red LED in Optical smoke detectors), enabling the detection of open fires, smoldering fires and fires with high heat generation. The detector is capable of identifying the TF1 and TF6 test fires described in the EN 54-9:1982 specification. Well suited for sensitive environment, detection of invisible up to large aerosols.This multisensor is an intelligent detector with time-related signal analysis, signal correlation of the sensor data, decentralized intelligence, automatic function self-test, CPU failure mode, automatic adaptation to environmental conditions, alarm and operating data memory, alarm indicator and soft-addressing.This detector to have decentralised intelligence, soft addressable with inbuilt fault isolator. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) .(for Operation Theatres)
Supply Installation,Testing,Commissioning of LEL (LPG,H2) Gas detector for monitoring LPG gas solvents type catalyic combustion sensor,with built-in alarm,potention free relay contact,range 0-100% LEL,4-20mAh output and field back lighted LCD Display with IP66 rating ,Exproof to Gas Group IIA IIB,Temperature class T4 UL/ATEX/BASEEFA
Supply, Installation & Testing, Commissioning of O2 Gas Detector 0 - 25% Vol. type electrochemical sensor, with built-in annunciator, potential free relay contact, range 0 - 100% LEL, 4- 20mA Output and field back lighted LCD Display with IP66 rating, Exproof to Gas Group IIA IIB, Temperature Class T4, UL/ATEX/BASEEFA Listed--
Supply, Installation,Testing & Commisioning of wireless Addressable module for integration of abiove third part wired devices having the following features Unique embedded addressing method. • Consistent communication with Centralized Monitoring System over RF • Works on standard 9V battery • Very Low standby current in range of 10-30 μA • RF Modulation type: Frequency Modulation • Works on Frequency: 433.9 MHz, 333 MHz, and 2.36GHz
Supply, Installation,Testing & Commisioning of wireless Addressable Manual Call Point soft addressable type • Standalone working in different zones. • Unique embedded addressing method. • Consistent communication with Centralized Monitoring System over RF • Works on standard 9V battery • Very Low standby current in range of 10-30 μA • RF Modulation type: Frequency Modulation • Works on Frequency: 433.9 MHz, 333 MHz, and 2.36GHz.
Supplying, installing, testing and commissioning remote response indicators complete as per specification no. FF-FAAS/RRI
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CBLT/CU
Supply, Installation, testing & Commissioning Digital Matrix System with 9 Stereo / Mono Inputs Channels & 8 Stereo / Mono Output Channels. Digitally controlled ove rWeb Interface, Touch Screen Panel (optional), Wall Panel, Anroid or IOs app AUDAC Touch. Built in ALC; Noise Gate, 5 Band Parametric Equalizer, Phantom Power, Delay,Filters. 8 Output Relays, 10 Contract Inputs Programmable, 256Pre-programmed events; Fiber Optical Interface for expansion; APM Paging Console for flexible paging solution Note: Bidder need to calculate PAVA controller quantity as per OEM recommendation suitable to accomodate required single/multi channel digital audio amplifiers & shall suffice the PAVA zone requirement of project.
Call Station: Supply, Installation, testing & Commissioning Digital Matrix System with 9 Stereo / Mono Inputs Channels & 8 Stereo / Mono Output Channels. Digitally controlled ove rWeb Interface, Touch Screen Panel (optional), Wall Panel, Anroid or IOs app AUDAC Touch. Built in ALC; Noise Gate, 5 Band Parametric Equalizer, Phantom Power, Delay,Filters. 8 Output Relays, 10 Contract Inputs Programmable, 256Pre-programmed events; Fiber Optical Interface for expansion; APM Paging Console for flexible paging solution
Multipurpose Device and Power Supply: Supply, Installation, testing & Commissioning of the multifunction power supply shall contain independent mains power supply to provide backup supply to PAVA controller & amplifiers. The multifunction power supply shall have an integrated battery charger for a connected battery, and independent converters to use the battery as a backup power source for all connected loads in case of mains failures. Failover to the backup battery shall be without interruption of output power. The multifunction power supply shall be certified for EN 54‑4 and marked for CE and be compliant. Note: Bidder need to calculate power supply quantity as per OEM recommendation suitable to accomodate controller & amplifiers mentioned tender BOQ. Battery backup calculation shall be done as per OEM receommendation.
Supply, Installation, Testing & Commissioning of 6W ceiling mount speaker Supply, Installation, Testing and Commissioning of 6W Full Metal ceiling mount speaker with excellent speech & music reproduction - Max Power: 9W,Rated Power: 6Watts, Power Tapping: 6/3/1.5W - Effective frequency range(-10 dB) : 100 Hz to 20 kHz - SPL at rated power (1Khz at 1 m) 92 dB - Opening Angle 1 KHz (-6 dB): 180°
Supply, Installation, Testing & Commissioning of 6W Cabinet mount speaker Supply, Installation, Testing and Commissioning of - 6W wall mount speaker with excellent speech & music reproduction - Max Power: 9W,Rated Power: 6Watts, Power Tapping: 6/3/1.5W - Effective frequency range(-10 dB) : 200 Hz to 15KHz - SPL at rated power (1Khz at 1 m) 96 dB - Opening Angle 1 KHz (-6 dB): 150/70
Supply, Installation, Testing and Commissioning of - 10W wall mount speaker with excellent speech & music reproduction - Rated Power: 6Watts, Power Tapping: 12/6/3W - Effective frequency range(-10 dB) : 200 Hz to 15KHz - SPL at rated power (1Khz at 1 m) 101 dB - Opening Angle 1 KHz (-6 dB): 195°
Supply, Installation, Testing and Commissioning of Volume Controller upto 20 W
Supply, Installation, Testing and Commissioning of CD/DVD/USB Player. Connect and play content via USB, Multi-format DVD and CD media playback, AAC, CD, CD-R/RW, DVD-Video, JPEG, LPCM, MP3, MPEG-1, Simple MPEG4, SVCD, Video CD, WMA. Power requirement -110-240VAC 50/60Hz
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB?LT/CU
Supplying and erecting HMS PVC conduit 20 mm dia. With PVC accessories on wall / ceiling as per specification No: WGMA/CON.
Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC
Supply, Installation, Testing & Commissioning of rack-mountable Workstation minimum 500GB hard disk, 3Gb RAM, i5 processor as per specification & approved make
Supplying, fixing, and configuring GB managed ethernet layer 2 switch of 20 ports + 4 SFP combo and web View/CLI as per specification complete.
Supply Installation Testing & Commissioning of IP 67 Rated 5 MP Motorised Varifocal Vandalroof Dome Network camera having 5megapixel (2560 x 1920) resolution, 3.7 ~ 9.4mm (2.5x) motorized varifocal lens, Max. 30fps@ all resolutions (H.265,H.264), 120 db WDR, 2D+3D DNR, Motion detection, Privacy masking, BLC/HLC, Min. Illumination: Color : 0.07Lux (F1.3, 1/30sec), B/W : 0Lux (IR LED on), H.265, H.264, MJPEG codec supported, Multiple streaming ( 10 profiles ), Day & Night (ICR), WDR (120dB), Defog, Built in Intelligent Video analytics like Loitering, Directional detection, Fog detection, Audio detection, Digital auto tracking, Sound classification, Tampering, Motion detection, Handover between cameras, SDXC memory slot (Max. 512GB), Coridoor view, Wise Stream II support, IR viewable length 50m, IP67, NEMA 4X, IK10, PoE / 24V AC, 12V DC. The camera should have model specific UL,CE,FCC, IP-67, IK-10 & NEMA 4X certifications
Supply Installation Testing & Commissioning of IP 67 Rated 1/3" CMOS 2 MP Motorised Varifocal Vandalroof Bullet Network camera having 3.2 ~ 10mm (3.1x) motorized varifocal lens; Field of View:H : 109˚ ~ 33˚ / D9, Max. 60fps@ H.265 resolutions; H.265, H.264, MJPEG codec supported, Multiple streaming; Backlight Compensation: BLC, HLC, 3DNR, Day & Night (ICR); WDR(120dB), Defog; Built in Intelligent Video analytics : Motion Detection, Video Tampering, Object Abandoned,, Tripwire, Intrusion, SD slots (Min 128GB); Security: Password protection HTTPS, IP Filter, Digest authentication, TLS1.2, AES-256 ; IR viewable length 30m, IP67, IK10. PoE/POE+ and 24V AC /12V DC; Operating temp range : –30°C to 60° C; The camera should have ONVIF Profile S, G compliance, UL,CE/EN,FCC, RoHS, IP-67, IK-10 certifications
SITC of Outdoor Application Low Light IP HPOE Supported Hi speed Dome type PTZ camera with 1/3" CMOS 2 MP Resolution, mim 4.75 ~ 261.4mm (Optical 55x) lens, triple stream, Low Light Min. Illumination: Color: 0.02Lux(F1.6, 1/30sec) BW: 0Lux(IR LED), Angular Field of View : H: 58.6°(Wide)~1.23°(Tele) / V: 34.8°(Wide)~0.71°(Tele); Day/Night (ICR), Pan speed : Preset: 400°/sec, Manual: 0.024°/sec~250°/sec; Tilt Speed : Preset: 250°/sec, Manual: 0.024°/sec~250°/sec: Sequence : Preset(300ea), Swing, Group(6ea), Trace, Tour, Auto Run, Schedule; Wide dynamic range 120 dB, BLC, HLC, 3DNR, DIS with builtin Gyrosensor ; Memory 1024MB RAM, 256MB Flash; Min. IR length : 500m; H.265, H.264, MJPEG codec support; Multiple streaming, WiseStream II support; Intelligent Video Analytics (Defocus detection, Directional detection, Fog detection, Face detection, Motion detection,Digital auto tracking, Appear/Disappear, Enter/Exit, Loitering, Tampering, Virtual line,Audio detection, Sound classification, Shock detection); Defog (Optical); microSD /SDHC /SDXC memory 2 slots (Up to 512 GB); • IP66, IK10
Supply, installation, Testing & commissioning of System Controlled Key board having 5" TFT touch LCD; Network/Analog cameras / SSM / DVR control; User-friendly design and easy-to-use keypad; 3 Axis joystick to control PTZ function; Detachable joystick / jogshuttle for universe use (Right / Left hand use); USB interface support (1ea for SSM, 1ea for image snapshot / Upgrade); Fast camera-tile mapping, Config import / export
SITC of 55" colour , Flat Screen Type Professional CCTV Surveillance HD monitor for above client workstation
Supplying, fixing, and configuring Managed L2 Power over Ethernet Switch of 20 Ports + 4G Combo Port as per specification complete
Supplying, fixing, and configuring layer 3/ 20 10/100/1000 base-T ports + 4 combo 10/100/1000Base-T/SFP ports + 4 10GE SFP+ ports - SI Image as per specification complete.
Supplying, fixing, and configuring 1-port mini-GBIC SX mutli?mode fibre transceiver (up to 550m, support 3.3V power) as per specification complete.
Supplying, fixing, and configuring 10G Base -SR SFP plus MM transceiver as per specification complete.
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 42 U floor mount server Rack (Dimension-DxW – 800x1000 x2070mm) as per specification No. WG-NAS/RAK
Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC
Supplying and erecting HMS PVC conduit 20 mm dia. With PVC accessories on wall / ceiling as per specification No: WGMA/CON.
Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, with core dia 50/125 µm (OM4) suitable for 1 gbps ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC
Supplying and plugging FRLS duplex 3 meter length, fibre patch cord LC-LC MM(50) OM4 LSZH duplex complete as per specification No. WG-COC/FPC
Supplying and fixing wall mount 24 ports, light guide interconnect unit with adapter panel as per specification complete
Supplying and fixing SC/LC type multimode duplex adapter to couple two connectors between OFC & Fibre switch/Fibre module as per specification no. WG-NAS/MMA
Supplying and fixing SC/LC type multimode pigtails (OM4)as per specification complete.
SITC of 19" rack mount Server Hardware for MAIN MANAGEMENT SERVER based on the powerfull Xeon E3-1275 v5 (8M Cache 3.6GHz) Processor , 8GB RAM 2EA internal memory & Embedded Windows 10 IoT Enterprise operating System, Minimum 128 Channel video inputs; 520Mbps Recording bandwidth & 150 Mbps Playback Bandwidth ;supporting a resolution of 12MP ~ CIF; Minimum 16 hot swappable drive slots supporting 10 TB HDDin each slot; RAID 0/1 /5 & 6 support; Automatic device IP scanning, Add profile edit, Resolution, Fisheye dewarping mode, Hallway View Setup, Brightness/Contrast, Viewing the device settings(Device webpage), Exporting/Importing devices settings,, Updating the device firmware. The server shall support Simultaneous All Channel Live Monitoring and Playback, Calendar / Event / Bookmark / Smart Search; Dual Track Recording, Active-Active Failover Support; Server Clustering Support and shall Have Dual SMPS and Redundant Power support
SITC of 19" rack mount Server Hardware for Main Recording Server; Intel® Xeon Silver 4114 2.2G, 10C/20T, 9.6GT/s , 14M Cache, Turbo,HT (85W) DDR4-2400 x 1No or better; Minimum 32GB RAM; Dual, Hot-plug, Redundant Power Supply (1+1), 750W; OS drive: 2 SATA/SSD HDD, Protected by RAID 1; 12 field upgrade 4 TB or 8 TB or 10 TB or 12 TB SATA/SAS hard drive options, Data RAID Level: 0, 1, 5, 6, 10. Network: 4 x 1GbE supporting network throughput of 800 MBPS, Video Adapter - Integrated Intel® HD Graphics for local client rendering support, Windows 64-bit Server 2012/2016 /Windows 10, Microsoft SQL Express 2012.
Supply Installation Testing & commissioning of 3.5 inch 12TB Enterprise Hard Disks of 7200 RPM with a Sata 6 GBps Interface, 256Mb Cache,600000 load/ Unload cycles,2500000(MTBF), with 5 Year Manufacturers warranty,and with the following poweer management capacities7.1 Sequential read, 6.7- Sequential write, 6.8 -Random read/write, 5.0- Idle
Supply, Installation, Testing & Commissioning of Video Management Software supporting ONVIF Profile S & G. The software shall be designed for commercial and industrial use and installed in a single PC as a stand-alone or in multiple sites providing a fully distributed solution with applications for remote users. B. The technology involved in development of this software shall be standard and proven and the provider shall be responsible for rigorous testing prior to the release. C. The provider shall offer training on installation, functions, specification or any other aspects of the software to the users. In addition, there shall be technical support both online and offline and it shall include design of systems, configuration of software, and review of devices in a system on compatibility and requirements. D. The following modules shall be included in the system. Detailed information of these modules can be found in Section 2.03 VMS Software and specification in 2.04 Detailed Specification of this document. 1. System Manager: Administrator program for all devices and users in System Manager controls the flow of data including request and transmission of media information, management of media streaming and events. Up to one system manager can be installed in a system. 2. Media Gateway: A module to connect cameras, NVRs, DVRs, encoders and other devices in CMS and to transmit video and audio to other modules. Device control, and transmission and receiving of media must go through Media Gateway. In addition, all devices must be registered under Media Gateway. 3. Console Studio: A monitoring client for live viewing, playback of recorded video and event monitoring. 4. Configuration Manager: A program that provides a graphical user interface for configuration of CMS. E. The following modules shall be added optionally. Detailed information on these modules can be found in Section 2.03 VMS Software and specification in 2.04 Detailed Specification of this document. 1. Recording Server: A module to record videos. 2. CMS Mobile: A mobile application for CMS. 3. Transaction Server: A module for integration of third party systems. 4. Screen Capture: A module for streaming of PC screen. 5. Virtual Matrix: A module for video walls. F. It shall be able to connect network cameras through manufacturers proprietary protocols or ONVIF. The number of cameras that can be connected to the software shall depend on the license. 1. Enterprise license: a. Direct connection 128 cameras per Media Gateway Unlimited number of Media Gateways per license b. Connection through NVR 288 cameras per Media Gateway Unlimited number of Media Gateways per license 2. Professional license: a. Direct connection 128 cameras per Media Gateway Four media gateways per license b. Connection through NVR 288 cameras per Media Gateway Four media gateways per license G. It shall be able to connect analog cameras through digital video recorders or encoders. The number of analog cameras that can be connected shall be same as the number of network cameras that can be connected. H. It shall provide users or clients seamless operations of all registered devices including network cameras connected directly to CMS, through network video recorders, through digital video recorders, or recording servers I. It shall allow control of display from the client PC
SITC of Client PC Hardware with a minimum speicification of Intel® Core™ Intel Core i7-8700, 3.2 GHz, OS - Genuine Microsoft Windows® 10 Enterprise 64-bit, RAM - 16GB, Hard Drives - 500 GB 7200RPM SATA3, Video Adaptor - Integrated Intel UHD graphics 630 and NVIDIA Quadro P620 supporting 4 Monitors over HDMI/VGA, Network Connection - 1 Gbit/sec or greater, Two(2) PCI-Express Expansion Slots 2/4 USB, CD/DVD ROM, USB Keyboard and Mouse, UPS, associated cables etc complete as required
Supply, installation, Testing and Commissioning of 5 Meter GI powder coated poles for mouting of 2Nos. Of camera on each poles with necessary accessories incluiding require foundation for the same with IP66 rated outdoor housing for power supply point & media convertor.
SITC of 8U wall mount network rack Compatible with 19” International standards, Front Door with Toughened Glass, Adjustable Mounting rails - Front and Black, Top and bottom cable entry provision, Frame structure with max loading capacity up to 50kg, Enclosure size W600 x D450 x H501 (mm)
Supply, Installation, Testing and Commissioning of Thermographic Dual-Sensor Camera with AI Face and Body Temperature detection Camera:• Dual sensor camera with QVGA thermal & 2MP visible video outputs • Built-in 4.7mm fixed lens (thermal), 4mm fixed lens (visible) • AI Face & temperature detection analytics including temperature & face overlay and alerts, detects people even while wearing a mask • Estimated Body Temperature Mode: +30°C~+45°C (+86°F~+113°F) / ±0.5°C (±0.9°F), ±0.3°C (±0.54°F) with blackbody • Normal Radiometric mode: -20°C~+130°C (-4˚F~+266˚F) / ±5˚C(≤+100˚C), ±20%(>+100˚C)±9˚F(≤+212˚F), ±20%(>+212˚F) • Micro SD/SDHC/SDXC memory slot (Maximum 512GB) • Integration of visible camera face detection with thermal camera Elevated Body Detection • PoE+, 12VDC powered
Supply, Installation, Testing and Commissioning of Tripod
Supply, Installation, Testing and Commissioning of Tripod Adaptor
Supply, Installation, Testing and Commissioning of 4 port Unmanaged Network PoE Switch: 4, Unmanaged, 4 Gigabit POE ports, 1 Gigabit RJ45 uplink port, 802.3af/at, PoE power budget 60w
Supply, Installation, Testing and Commissioning of Video Management Software
SITC of PC/Laptop Hardware with a minimum speicification of Intel® Core™ Intel Core i7-8700, 3.2 GHz, OS - Genuine Microsoft Windows® 10 Enterprise 64-bit, RAM - 16GB, Hard Drives - 500 GB 7200RPM SATA3, Video Adaptor - Integrated Intel UHD graphics 630 and NVIDIA Quadro P620 supporting 4 Monitors over HDMI/VGA, Network Connection - 1 Gbit/sec or greater, Two(2) PCI-Express Expansion Slots 2/4 USB, CD/DVD ROM, USB Keyboard and Mouse, UPS, associated cables etc complete as required (For Installing Video Management Software)
Supply, Installation, Testing and Commissioning of 8ch Network Video Recorder- Connect Up to 8 IP Cameras, Dual OS, Up to 12 Megapixels Resolution, HDMI output with 4k output and VGA output with 2MP Output , Support H.265,H.264, MJPEG, Incoming Bandwidth 80 Mbps, 2 SATA Hard Disks, ANR Technology, 2 SATA interfaces for 2 HDDs and capacity of each HDD upto 8TB, 2 USB at least 1 × USB with 3.0, Alarm I/O 4/1, 1 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified.
Supply, Installation, Testing and Commissioning of 6TB Surveillance Hard Disk
Supply, Installation, Testing and Commissioning of Surveillance class Common Micro SD Card 128GB for camera
Supplying and erecting HMS PVC conduit 20 mm dia. With PVC accessories on wall / ceiling as per specification No: WGMA/CON.
Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC
Supply, Installation, Testing & Commissioning of 4K HDMI Matrix Switcher with min. 8 Nos. of 4K HDMI & 8 Nos. of 4K HDMI with inbuit or external Audio De-embedder. Matrix Switch should support preset saving and recalling option through TELNET, RS232, Front Panel Button, Web Browser and IR Remote.
Supply, Installation, Testing & Commissioning of 10.1 Inch Touch Panel with Table mount Kit and External Control system. Control system should control 2 IR/1-Way RS232, 2 Bi-Directional RS232, 4 Relay ports to control the screens/drapes. RJ45 port to communicate and control the TELNET controllable devices. System should include 2 Free license for IPAD/Android Tablets for control interface.
Supply, Installation, Testing & Commissioning of 4K HDR HDMI DA : 1:2 4K HDMI Splitter for up to 4K HDR, HDMI 2.0 signals that comply with HDCP 2.2 content protection standard
Supply, Installation, Testing & Commissioning of 4K Encoder with Minimum 1 HDMI and 1 Stereo Audio Input and 1 Nos Ethernet port at output with GBPS support with RS-232 control with less than 1sec transmission delay with locking connecter power supply. Encoder should have IR, RS232 and USB ports for control signal transmission
Supply, Installation, Testing & Commissioning of Media Processor. Should support upto 1080p 60fps video recording, should support inputs like HDMI/LAN with capability of Recording and Streaming minimum 4 Full Motion Video Inputs in single frame, Flexible scaling and window processing, supports PIP, PBP and up to 4 windows layout and mixing, should have min Built-in 1TB HDD storage, should support options to upload recordings to an external USB device or the FTP server, should support Streaming Protocol Pull: RTSP. Push: RTMP / RTMPS / MPEG-TS TCP, UDP, HTTP DHCP Client. Should be CE, ROHS and FCC certified.
Supply, Installation, Testing & Commissioning of Multi-Channel Video Streaming device on CDN Streaming media : Media Encoding,Trans-coding, Recording with extenal disk and Streaming Platform. Push out RTMP multicast. Stream directly to devices with CDN/RTMP Media Player like Youtube. Stream to content delivery networks like Youtube, Facebook Live and more. Record streams in Extenal Harddisk or Flash card for later on-demand playback. Player should support 2 Live sources with added Image and Text overlay. Extenal IPAD Pro required for Configuration.
Supply, Installation, Testing & Commissioning of Multi-Channels Video Streaming Server Software for deployment in cloud installation: Media Trans-coding, Decoding, Recording and Streaming Platform, Pull in RTMP, RTSP, HTTP, UDP and TCP; Push out RTMP, UDP unicast and multicast, Stream directly to devices with our white labelled web player, Stream to content delivery networks like Youtube, Facebook Live and more, Record streams in Device for later on-demand playback, Run a multi-channel on-demand IPTV network, Streaming server software one-lifetime license, Cloud installation, One year remote suppor t included
Supply, Installation, Testing & Commissioning of NAS for : Quad-Core Intel® Celeron® J3455 1.5GHz (upto 2.3 GHz), 4GB DDR3L (Max 8 GB), 2 x 1Gbe Ethernet Ports (Expandable up to: 4 x Gigabit LAN or 2 x 10 Gigabit + 2 x Gigabit LAN) with 80TB HDD usable after Raid 5 configuration
Supply Installation Testing & Commissioning of Two-way Coaxial In-ceiling Loudspeaker with 6.5” LF paper cone material & 1" HF Driver with Power handling 30W @ 8 Ohms & 100V Multi Taps 60W / 30W / 15W ; Frequency range 45Hz – 20Khz ; Sensitivity (1W/1M) 84 dB and max SPL 101 dB ; Conical dispersion of 155° . Twistfix Edgeless Grill & safelatch Mounting. Ceramic Screw Terminal with link through.The enclosure material ABS plastic and steel grill with Metal backan with Safelatch Mounting System with Multi-functional SourceCon™ Class-D Amplifier Power Output 2 x 80W @ 4 Ohms / 8 Ohms & 1 X 160W @ 70V / 100V; 2.8" TFT Display; 1 X Line Input ; 1 X Mic Input ; 4 X 4 Dante (Optional) ; Control Port : TCP/IP (RJ45), RS232, RS485; S/N Ratio > 90 dB; THD < 0.05% ; Frequency Response 20Hz - 20KHz; 19" Rack Mount Optional
Supply, installation, testing & commissioning of ceiling microphone with patented beamforming technology ,Optimize your digital workflows with software. The microphone can be easily controlled and monitored from anywhere in the network. For 100% connectivity - Connect the microphone via analogue or digital DANTE™ audio outputs to any conference system. Power-over-Ethernet (PoE) makes integration of the ceiling microphone very easy. An open media control protocol (API) allows you to make individual adjustments. With Min. 28 x pre-polarized condenser capsule.1 x 3-pin terminals ; 2 x Digital Dante Network Audio (RJ45).
Supply Installation Testing & Commissioning of PHIHONG Gigabit PoE+ Injector, IEEE802.3af compliant, IEEE802.3at classified, 90-264 VAC Input Voltage
Supply, Installation, Testing & Commissioning of Lavalier Microphone Microphone with smallest lavalier microphone set optimized for speeches and lectures. Automatic frequency and interference management, Digital transmission (1.9 GHz)Speech optimized condenser microphone capsule, Clear and easy focused user interface,Long operation time (up to 15 hours), Advanced power management and Li-Ion rechargeable, Secure 256 bit AES encryption, Remote controllable, Frequency response 20 to 20,000 Hz , Connection Audio out: XLR 3M Audio out: 2x RCA , RF output power adaptive, up to 250 mW (country-specific) Transducer principle Condenser ,All sets also come with rechargeable accupacks with up to 15 hrs. of operating time. The accupack is also USB rechargeable, the cable is in the box, the USB socket is presumably. Sound pressure level (SPL) 152 dB ,Audio output level (balanced) max. -18 dBu, typ. -24 dBu ,Audio output level (unbalanced) max. +6 dBu ,Lockable 3.5 mm jack socket
Supply, Installation, Testing & Commissioning of Enterprise Management Platform : an enterprise management platform that lets IT and AV professionals easily deploy, configure and manage an entire Pro AV installation from anywhere in the network, including 3rd party devices.
Supply Installation Testing & Commissioning of 20M High–Speed HDMI AOC Cable Max. Data Rate — 18Gbps. Max. Resolution — 4K@60Hz (4:4:4). Deep Color — Supports 24–bit, 30–bit, 36–bit and 48–bit (RGB or YCbCr) color depths. Best for multimedia applications or home cinema and surround systems. Multi–Channel Audio Support — Supports audio stream for external decoding by AV receivers and automatic audio syncing capabilities. High Quality Connectors — 24K gold–plated, corrosion–resistant and best possible connectivity.
Supplying & installing HDMI cable low voltage gradeas per specifications having 15 mtr cord length with male/female 19pin HDMI connectors as per requirements complete.
Supplying & installing HDMI cable low voltage grade as per specification as per specifications having 10 mtr cord length with male/female 19pin HDMI connectors as per requirements complete.
Supplying & installing HDMI cable low voltage grade as per specification as per specifications having 3 mtr cord length with male/female 19pin HDMI connectors as per requirements complete.
Supply, Installation, Testing & Commissioning of Passive Wall Plate — HDMI: Front Panel Connection — 1 HDMI (F). Rear Panel Connection — 1 HDMI (F) on a flat, flexible cable.
Supply Installation Testing & Commissioning of Dual HDMI Module Passive Wall Plate — HDMI: Front Panel Connection — 1 HDMI (F). Rear Panel Connection — 1 HDMI (F) on a flat, flexible cable.
Supply, Installation, Testing & Commissioning of 2 Core 20 AWG routing balanced, mono or unbalanced stereo mic or line level audio signals or Control signals cable with PVC conduit.
Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC
Supplying and erecting HMS PVC conduit 20 mm dia. With PVC accessories on wall / ceiling as per specification No: WGMA/CON.
Supplying and fixing 22 U floor mount rack (Dimension-DxW – 800x600x 1176mm) as per specification No. WG-NAS/RAK
Supply Installation, Testing & Commissioning of Full HD 1080p, minimum 20X Optical Zoom, min 100 Presets, 60 Frames per Second, Ethernet Out, HDMI Out, 3G-SDI Out Simultanious, Audio In, RS232/422 Controls, -170° ~ +170° Panning angle, -30° ~ +90° Tilting angle , Should support PoE+. Should be CE, ROHS and FCC certified.
Supply Installation Testing & Commissioning of Surgical Monitor having 24” Clinical Review Display with 1920x1200 native pixel resolution and LED backlight. Features high-quality/high bright LCD panel, 10-bit DICOM LUT, Front Consistency Sensor, QAWeb, Adjustable stand (height/tilt/swivel/pivot), Scratch-proof front glass, External power supply, White bezel.
Supply Installation Testing & Commissioning of 42'' Surgical Display, Resolution-1920 X 1080, Aspect Ration-16:9, Screen Technology- TFT AM LCD, Viewing angle H-V: 178, input: HDMI, DVI. Complaint-CE, ISO, RoHS
Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No.WG-COC/NC
Supplying and fixing tool-less information outlet (ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO for Data
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 1 meter length, UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying and fixing 3 meter length, UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting ISI mark modular type computer jack RJ 45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting FR grade, pvc armoured multimode optical fibre cable with 6 fibres, with core dia 50/125 µm (OM3) suitable for 1 gbps ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC LSZH
Supplying and fixing rack mounted type 12 ports, light guideunloaded interconnect unit for termination of optical fibre cables on wall/ provided U rackcomplete as per specification no. WG-NAS/ LIU
Supplying and fixing 1 x 6 duplex adapter panel - SC as per specification complete
Supplying and fixing SC/LC type multimode duplex adapter to couple two connectors between OFC & Fibre switch/Fibre module as per specification no. WG-NAS/MMA
Supplying and fixing SC/LC type multimode pigtails (OM3) for LIU to terminate OFC in LIU as per specification No. WGNAS/LIU2
Supplying & installing single mode fibre patch cord 3 m – duplex complete.
Supplying and fixing rack type 24 ports, light guideinterconnect unit of optical fibre cables on wall/ provided U rack complete as per specification no. WG-NAS/ LIU
Supplying and fixing 1 x 12 duplex adapter panel - SC as per specification complete
Supplying and fixing SC/LC type multimode duplex adapter to couple two connectors between OFC & Fibre switch/Fibre module as per specification no. WG-NAS/MMA
Supplying and fixing SC/LC type multimode pigtails (OM3) for LIU to terminate OFC in LIU as per specification No. WGNAS/LIU2.
Supplying & installing single mode fibre patch cord 3 m – duplex complete.
Supplying and fixing 42 U floor mount server Rack (Dimension-DxW – 800x1000 x2070mm) as per specification No. WG-NAS/RAK
Supplying and fixing 22 U floor mount rack (Dimension-DxW – 800x600x 1176mm) as per specification No. WG-NAS/RAK
Supplying & erecting HMS PVC conduit 25 mm. dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting ISI marked modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type T.V. Socket single outlet, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying & erecting jelly filled armoured telephone coppercable 50 pair with 0.5 mm dia. laid in provided trench as per specification No. WG-TW
Supplying & erecting jelly filled armoured telephone copper cable 100 pair with 0.5 mm dia. laid in provided trench as per specification No. WG-TW
Supplying & erecting copper jumper wire with 0.5 mm dia as per specification No. WG-TW
Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No.WG-COC/NC
Supplying & installing co-axial copper cable low voltage grade RG-6 as per specification No. WG-TW
Supplying, erecting & commissioning Main Distribution Frame (MDF) Box 50x50 pairs as per specification No. WG-TW
Supplying, erecting & commissioning Main Distribution Frame (MDF) Box 100x100 pairs as per specification No. WG-TW
Supplying, erecting & commissioning Main Distribution Frame (MDF) Box 2000x2000 pairs as per specification No. WG-TW
Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification No. WG-TW
Supplying, Installing, Testing & Commissioning of IP Based Unified Communication System having capacity of 820 Analogue Extensions, 08 Digital Extensions, 08 Analogue Trunks, 01 PRI, 100 IP Extensions. System should loaded with redundant CPU and Power supply from the day 1 for redundancy purpose. System should be networkable with other system and simultaneous 200 Calls can be working.
Supplying and installing testing & commissioning of EPBAX Gateway for segregation of Telephone lines with all necessory accessories & components.
Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID unit as per specification complete.
Supplying, installing, testing & commissioning approved type Digital key telephone / IP telephone instrument as per specification complete.
Supplying & erecting HMS PVC conduit 25 mm. dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supply, Installation, Testing & Commissioning of Switch: 16 Nos. Gigabit SFP+ Ports,Network Module slot for 8 SFP+ Fiber Uplink Ports, Stackable L3 Managed Enterprise Switch with Redundant Power Supply. Switch should support for Layer3 Routing: a. Class-less, b. Default, c. Static, d. Policy based e. Dynamic routing and route redistibution between multiple routing protocols for IP V4 and IP V6, The Switch should be supplied with required Stack Modules, Stack Cables etc. Detailed specifications as per specification sheet.
Supply, Installation, Testing & Commissioning of Access Network Switch: 24 Port 10/100/1000 Base-T with 2 Port 10G SFP+ Manage L2 Enterprise Switch. Flex-Stack Plus Capability ; should be capable of redundant power supply; 512MB or Higher DRAM, 600MHz Dual Core or Higher CPU; 208Gbps full-duplex or Higher switching bandwidth; 4K VLAN ID; 68 Mpps or higher forwarding rate; Detailed specifications as per Specification Sheet.
Supply, Installation, Testing & Commissioning of Access PoE Network Switch: 24 Port10/100/1000 Base-T PoE with 2 Port 10G SFP+ L2 Managed Enterprise Switch. PoE budget 370W or higher and should be capable of redundant power supply, FlexStack-Plus Capability; 512MB or Higher DRAM, 600MHz Dual Core or Higher CPU; 208Gbps full-duplex or Higher switching bandwidth; 4K VLAN ID; 68 Mpps or higher forwarding rate; Detailed specifications as per Specification Sheet.
Supply, Installation, Testing & Commissioning of 10G Base SFP+ Multimode Tranceiver for L2/L3 switch, Single mode, LC termination supporting distance upto 2000 mtrs SFP+ Module should be same make of Switch.
Supply, Installation, Testing & Commissioning of Wi-Fi access point with 1 GBIC Port, 3x3 MIMO, 2 Spatial Streams as per IEEE 802.11a/b/g/n/ac, should support throughput of 300Mbps on 802.11a/b/g/n and 867 Mbps on 802.11ac and PoE as per IEEE 802.3a/f.
Supply, Installation, Testing & Commissioning of Wireless Controller System, including Hardware Based Controller, capable of supporting min. 1000 access points from Day one, inclusive of licence cost for 325 access points. Controller should have minimum 2 × 1Gb Port or 2 × 10Gb Port; 01 mGig Port , capable of intrusion prevention system, application visibility control and should support High Availability.
Supply Installation Testing & Commissioning of Network Security Appliance for 2000 Concurrent Users Support and with 3 Years support from OEM
Supply, Installation, Testing & Commissioning of Application Server Platform with no user restriction; 5000 User license of Time Attendance which can be expandable as per customer requirement, support 65000 Conrollers.
Supply, Installation, Testing and Commissioning of Access Control License. Comprehensive Access Control Management. Perpetual Cost for Time, User & Zone Based Access Control, Access Zones, Access Modes & Access Levels. Advanced Access Control features like 2-Person Rule, First-in User Rule, Anti-pass Back, Guard Tour, Duress Detection & More. Various Reports Generation.
Supply, Installation, Testing and Commissioning of Time Attendance License.
Supply, Installation, Testing and Commissioning of Access Control Panel for Multiple Door Controllers, Ethernet, RS-485,USB, Aux Input & Output Port, Shall work as Standalone / Network Mode.
Supply, Installation, Testing & Commissioning of Fingerprint and EM Proximity Card Based Door Controller, IP65 Rating, 50,000 Events and 9,600 Fingerprint Template Storage, Built-in PoE, Built-in Door Lock / Door Sense / Exit Reader / Exit Switch Ports, RS-485 and Ethernet Interfaces. Tri-color LED & Buzzer.
Supply, Installation, Testing & Commissioning of Exit Switch with Metal Finish.
Supply, Installation, Termination & Commissioning of EM Magnetic Lock 600 LBS with Door Sense, Mounting Clamp.
Supply, Installation, Termination & Commissioning of Access Control Solution : Supply, Installation, Testing & Commissioning of Access Control Access System Monitoring Hardware Central Work Station Server with i5 Intel processor with minimum 500Gb HDD, 4 GB RAM, 21" TFT Monitor, DVD Writer, two serial and one parallel ports, multimedia speakers, infrared mouse; Work station shall be preloaded with requisite MS Windows Licensed software compatible with the Access Control platform
Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No.WG-COC/NC
Supplying & erecting HMS PVC conduit 25 mm. dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Conference Room Supply, installation, testing & commissioning of table top digital unit with delegate unit with super cardioids/ array microphone or better, good neck length minimum 40 MM , Twin/ Two way loudspeaker for better sound reinforcement, microphone on/off button, RJ-45 daisy chain,Pick-up Patten - super-cardioid,Headphone connection : 3.5 mm stereo jack socket with Frequency response of190Hz to 14.5 KHz The digital discussion system shall control up to 400 connected delegate and chairperson units. It shall offers full configuration in a quick and easy way over the menu display in several languages. Alternatively the integrated software package‚ Conference Manager‘ can be used directly on the Central Unit by connecting a Screen (VGA), Mouse and Keyboard (USB).The intuitive workflow of the conference manager shall allowsa fluent monitoring and control of the conference. With its low?noise fan the central unit can be used directly in the meeting without disturbing it and shall offer high speech-intelligibility in a modern design. The gooseneck microphone shall be equipped with a super-cardioid capsule that attenuates unwanted ambient noise efficiently. A twin-loudspeaker system guarantees a homogenous sound level in the meeting room. The cabling of the units, which is done by CAT5 cables and hidden connections can be optionally secured with strain reliefs for fixed installations.
Supply, installation, testing & commissioning of Table Top Digital Chairman unit with super cardioids/ array microphone or better, good neck length minimum 40 MM or better, Twin/ Two way loudspeaker for better sound reinforcement, microphone on/off button, priority switch for temporary muting delegates, RH-45 daisy chain pick-up Patten - super-cardioid,Headphone connection : 3.5 mm stereo jack socket with Frequency response of190Hz to 14.5 KHz The digital discussion system shall control up to 400 connected delegate and chairperson units. It shall offers full configuration in a quick and easy way over the menu display in several languages. Alternatively the integrated software package‚ Conference Manager‘ can be used directly on the Central Unit by connecting a Screen (VGA), Mouse and Keyboard (USB).The intuitive workflow of the conference manager shall allowsa fluent monitoring and control of the conference. With its low?noise fan the central unit can be used directly in the meeting without disturbing it and shall offer high speech-intelligibility in a modern design. The gooseneck microphone shall be equipped with a super-cardioid capsule that attenuates unwanted ambient noise efficiently. A twin-loudspeaker system guarantees a homogenous sound level in the meeting room. The cabling of the units, which is done by CAT5 cables and hidden connections can be optionally secured with strain reliefs for fixed installations.
Supply, installation, testing & commissioning of digital audio conference control unit for conference system supplies power for minimum for 40 Units and control up to minimum 400 discussion units with power supply. Redundant closed loop cabling, built in external USB audio recorder. An Ethernet port shall be provided for network connection and control units, Integrated external PC , pre-installed control software for management synoptic and audio recording etc. The digital discussion system comprised of a central control unit and remote delegate and chairperson discussion units is provided; optional power supplies/system expanders shall be provided. The digital discussion system shall be capable of powering and controlling up to 400 connected delegate and chairperson units (using optional power supplies/expander units). The digital discussion system central control unit shall provide an intuitive integrated software control display interface; the graphical user menu shall display in 13 languages and allow fault monitoring and error diagnostics, and control of the conference. Alternatively, the central control unit software shall be accessible by connecting a standard VGA monitor, keyboard and mouse (USB). An Ethernet port shall be provided for network connection and control through third party digital control systems (Crestron, AMX, etc.). USB recording capability shall be provided for the conferencing program audio. The central control unit shall include a low-noise cooling fan for use directly in meeting rooms without noise disturbance The digital discussion system central control unit shall be capable of powering and controlling up to 40 stand alone digital delegate units and/or the digital chairperson units (depending on cable length). The addition of optional cascadable pow?er supply units shall allow the expansion of the conferencing system to up to 400 digital delegate units and/or the digital chairperson units to the central control unit; use of the optional power supply unit shall allow redundant ring-cabling on its four conference ports, providing increased failure-safety between the central control unit and the digital delegate units and the digital chairperson units.The operating voltage of the proprietary control bus shall be 52.8 V⎓. Audio frequency response of the system shall be 100 – 14,000 Hz; total harmonic distortion shall be < 0.01% A-Weighted at +6 dBV in/out. Audio signal input voltage range shall be -18 to +18 dBu (XLR in); maximum output level shall be +10 dBV. Signal-to-noise ratio shall be >80 dB A-Weighted at +18 dBV.
Supply, installation, testing & commissioning of Flush Mount Kit for the above Chairman/Delegate
Supply, installation, testing & commissioning ofRJ 45 Cable with Shielded-Twisted-Pair (STP), AWG24, Gold-plated connectors, 3 mtrs
Supply, installation, testing & commissioning of RJ 45 Cable with Shielded-Twisted-Pair (STP), AWG24, Gold-plated connectors, 20 mtr
Supply, installation, testing & commissioning of two-channel audio output card for analog signals, complete with high-quality 32-bit digital to analog converters.
Supply, installation, testing & commissioning of 2ch input + 2ch output USB audio card. Occupies two (2) card slots.
Supply, installation, testing & commissioning of 8” programmable touch control, mounts into a US 2-gang box or included low voltage bracket. Portrait or landscape orientation. PoE powered, external power supply not included.
Supply, installation, testing & commissioning of 2-way Cabinet Loudspeaker, LF Driver 4” & HF Driver 1" Dome Tweeter; Max Power handling 70W @ 8 Ohms; Multiple 100V Taps : 24W / 12W / 6W; Frequency range 65Hz – 20Khz ; Sensitivity 86 dB and Max SPL 101 dB; Coverage of 130° x 130° (H X V) ; IP40 Rated; Operating Temperature -20°C to 60°C; ABS Plastic Housing with steel grill. Black.
Supply, installation, testing & commissioning of Single Channel Class D Amplifier; Power Output 240 W / CH @ 100V; Protection : DC Shorcuit, Over load, Over heat, Signal Limiting, Temperature controlled Fan; THD < 1%; SN Ratio > 90 dB; Crosstalk < 80 ; Input : XLR Connector with link ; Output : 4-pin Terminal; Switch Mode Power Supply The amplifier shall be professional single channel 100V power amplifier with a power of 240 Watt, especially designed for most common 100V PA systems, and perfect to be used in combination with a pre-amplifier. It is designed as a no-nonsense amplifier with only the necessary controls and connections. Tit shall have several power output taps available for use in 100V, 70V and even 4 Ohm Low impedance installations and shall be fitted with an advanced multipurpose protection circuit. The protection circuit shall detect DC malfunction, short circuit, overheating, overload and limits the signal when necessary. it shall support 24 V DC connection for powering the amplifier with emergency power when the main power is shut down. At the back of the amplifier, there shall be trim potentiometers to set the input level, a high pass filter switch and a ground lift switch provided. The input connection shall be made with balanced XLR connectors, and there’s a signal output for linking with other amplifiers.
Supply, Installation, Testing & Commissioning of Lavalier Microphone Microphone with smallest lavalier microphone set optimized for speeches and lectures. Automatic frequency and interference management, Digital transmission (1.9 GHz)Speech optimized condenser microphone capsule, Clear and easy focused user interface,Long operation time (up to 15 hours), Advanced power management and Li-Ion rechargeable, Secure 256 bit AES encryption, Remote controllable, Frequency response 20 to 20,000 Hz , Connection Audio out: XLR 3M Audio out: 2x RCA , RF output power adaptive, up to 250 mW (country-specific) Transducer principle Condenser ,All sets also come with rechargeable accupacks with up to 15 hrs. of operating time. The accupack is also USB rechargeable, the cable is in the box, the USB socket is presumably. Sound pressure level (SPL) 152 dB ,Audio output level (balanced) max. -18 dBu, typ. -24 dBu ,Audio output level (unbalanced) max. +6 dBu ,Lockable 3.5 mm jack socket. The system shall consist of a stationary receiver, a bodypack transmitter and a condenser clip-on microphone. Operating in the license-free 1.9 GHz band (frequency ranges are between 1,880 and 1,930 MHz, depending on country-specific regulations), the system shall use automatic frequency management to determine the best free available frequency and to automatically start the transmission. Additionally, the system shall incorporate automatic interference management, allowing the trans?mitter and receiver to move to an undisturbed, compat?ible frequency with no audio signal interruption, should interference occur. Furthermore, advanced 256-bit AES encryption shall be used for secure wireless transmission.The system’s AF frequency response shall range from 20 – 20,000 Hz. The dynamic range shall be > 120 dB(A). Total harmonic distortion (THD) at 1 kHz shall be typical 0.1 %. Signal-to-noise ratio shall be > 90 dB(A). Latency shall be 19 ms. Operating temperature shall range from -10 °C to +55 °C (+14 °F to +131 °F).The user interface of the receiver shall be operated by jog dial and OLED display. The receiver shall have dedicated pairing, escape and power buttons.The receiver shall feature a low-cut filter as well as speech-optimized sound profiles or custom settings with a 7-band graphic equalizer. The receiver’s RF sensitivity shall be -90 dBm. RF output power of the receiver’s back chan?nel shall be adaptive and up to 250 mW (country-specific). The receiver’s audio output shall utilize a balanced XLR?3M socket with a maximum output of +18 dBu along with two unbalanced RCA sockets with a maximum output of +6 dBu. The receiver shall feature automatic gain opti?mization. Two reverse SMA sockets shall be provided for connecting the antennas
Supply, Installation, Testing & Commissioning of Handheld Microphone Microphone with Automatic frequency and interference management, Digital transmission (1.9 GHz)Speech optimized condenser microphone capsule, Clear and easy focused user interface, Long operation time (up to 15 hours), Advanced power management and Li-Ion rechargeable, Secure 256 bit AES encryption, Remote controllable, Frequency response 20 to 20,000 Hz , Connection Audio out: XLR 3M Audio out: 2x RCA , RF output power adaptive, up to 250 mW (country-specific) Transducer principle Condenser ,All sets also come with rechargeable accupacks with up to 15 hrs of operating time. The accupack is also USB rechargeable, the cable is in the box, the USB socket is presumably. Sound pressure level (SPL) 152 dB ,Audio output level (balanced) max. -18 dBu, typ. -24 dBu ,Audio output level (unbalanced) max. +6 dBuThe system shall consist of a stationary receiver and a handheld transmitter with a condenser microphone head. Operating in the license-free 1.9 GHz band (frequency ran?ges are between 1,880 and 1,930 MHz, depending on coun?try-specific regulations), the system shall use automatic frequency management to determine the best free avai?lable frequency and to automatically start the transmis?sion. Additionally, the system shall incorporate automatic interference management, allowing the transmitter and receiver to move to an undisturbed, compatible frequen?cy with no audio signal interruption, should interference occur. Furthermore, advanced 256-bit AES encryption shall be used for secure wireless transmission. The system’s AF frequency response shall range from 20 – 20,000 Hz. The dynamic range shall be > 120 dB(A). Total harmonic distortion (THD) at 1 kHz shall be typical 0.1 %. Signal-to-noise ratio shall be > 90 dB(A). Latency shall be 19 ms. Operating temperature shall range from -10 °C to +55 °C (+14 °F to +131 °F). The user interface of the receiver shall be operated by jog dial and OLED display. The receiver shall have dedicated pairing, escape and power buttons.The receiver shall feature a low-cut filter as well as spe?ech-optimized sound profiles or custom settings with a 7-band graphic equalizer. The receiver’s RF sensitivity shall be -90 dBm. RF output power of the receiver’s back chan?nel shall be adaptive and up to 250 mW (country-specific).The receiver’s audio output shall utilize a balanced XLR- 3M socket with a maximum output of +18 dBu along with two unbalanced RCA sockets with a maximum output of +6 dBu. The receiver shall feature automatic gain opti?mization. Two reverse SMA sockets shall be provided for connecting the antennas.The receiver shall feature RJ-45 network connectivity com?patible with IPv4 and IPv6 networks. For remote control the receiver shall have media control protocol integration.The receiver shall operate on 12 V DC power supplied from the NT 12-4C
Supply, Installation, Testing & Commissioning of 2-bay table top charger with power supply The bi-color LED provides the status (charging or fully charged). Power consumption 2.5 A ,Operating temperature 5 °C to 35 °C (41 °F to 95 °F) Max. Charging current of max. 2 x 1000 mA (Model - CHG 2 Make - Sennheiser Or Equivalent)
Supply, installation, testing & commissioning of Video conferencing system with the following features Video standards: H.264 AVC, H.264 High Profile, H.265, RTV, H.239, H.264 video error concealment Support; Video Inputs:1 HDCI/1 HDMI/1 USB; VIDEO OUT: 2x HDMI, Touch display compatible; VIDEO RESOLUTION:{ Capable to support 4K, 30 fps (TX and RX) from 2048 Kbps, 1080p, 60 fps from 1740 Kbps, 1080p, 30 fps from 1024 Kbps, 720p, 60 fps from 832 Kbps, 720p, 30 fps from 512 Kbps, 4SIF/4CIF, 60 fps from 512 Kbps, 4SIF/4CIF, 30 fps from 128 Kbps, SIF (352 x 240), CIF (352 x 288), From 64 kbps, QCIF (176 x 144) from 64 kbps, w288p from 128 Kbps, w448 from 384 Kbps, w576p from 512 Kbps}: CONTENT VIDEO RESOLUTION { Input : UHD (3840 x 2160), HD (1920 x 1080p), WSXGA+ (1680x 1050), UXGA (1600 x 1200), SXGA (1280 x 1024), WXGA(1280 x 768), HD (1280 x 720p), XGA (1024 x 768), SVGA (800x 600).}; Output :{ UHD (3840 x 2160), WUXGA (1920 x 1200), HD (1920 x 1080), WSXGA+ (1680 x 1050), SXGA+ (1400 x 1050),SXGA (1280 x 1024), HD (1280 x 720), XGA (1024 x 768) }; { CONTENT SHARING: Poly Content App support, Apple Air Play, Miracast, 1x HDMI input} ; AUDIO INPUT: {Capability to support up to three 1x IP microphone arrays, Up to 4x Clink2 Microphones or Sound Structure }: AUDIO OUTPUT: { 1x HDMI, 1x 3.5 mm stereo line-out} ; OTHER INTERFACES: {3x USB , 1x USB-C, 1x RS-232, 8-pin mini-DIN, Bluetooth 5.0, WiFi 802.11a/b /g/n/ac (MIMO) Multichannel} ; AUDIO STANDARDS AND PROTOCOLS:{ 22 kHz bandwidth with Polycom Siren 22 technology, G.719 (M- Mode), 14 kHz bandwidth with Polycom Siren 14 technology, G.722.1, 7 kHz bandwidth with G.722, G.722.1, 3.4 kHz bandwidth with G.711, G.728, G.729A}; NETWORK: { IPv4 support, 1x 10/100/1G Ethernet, Auto- MDIX, 3x 10/100/1G LLN supporting POE+/PSE, H.323 and/or SIP up to 6 Mbps, Polycom Lost Packet Recovery (LPR)technology, Dynamic bandwidth allocation, Reconfigurable MTU size, RS232 with REST and CLI API support, Web Proxy support—Basic, Digest and NTLM, Simple Certificate Enrolment Protocol(SCEP)} , Single USB port functionality to use the system as an external camera, microphone and speaker when connected to a Laptop/PC.; SECURITY {Media encryption (H.323, SIP): AES-128,AES-256, H.235.6 support, Authenticated access to admin menus, web, interface and APIs, PKI /Certificate Management:- TLS 1.2, 1.1, 1.0, Self-signed and CA-signed certificate support, CRL and OCSP-based certificate revocation checking, Local account password policy configuration, Security profiles, Local account and login port lockout, Secure defaults, Remote logging with support for TLS
Supply installation testing and commissioning of 55 inch colour LED flat screen type professional-grade HD monitor / TV.
Supply, installation, testing & commissioning of 4 x 4 HDMI matrix switcher. Should have 4 HDMI inputs & 4 HDMI outputs. Should support resolution up to 4K@60Hz (4:2:0) & 4K@30Hz (4:4:4). Should have HDMI Deep Color, 3D,, up to 7.1 uncompressed audio channels. Should support HDCP 2.2 and HDMI 1.4a compliance. Should have Lock Button mechanisim for conneted HDMI Cables. Should have Flexible control options viz Front Panel,RS-232 & infrared remote contro
Supply, Installation, Testing & installation of Simultaneous Wired and Wireless Presentation and Collaboration Solution Wireless presentation device allows users with laptops or mobile to connect and present, HDMI input to connect a source with HDMI directly, 1 HDMI & 1 Mini DP/VGA output, one Gigabit LAN Ethernet port, audio de-embedding feature with one 3.5mm mini jack line out, Wireless Connection for up to 252 user devices, present minimum 4 users laptops or handheld devices on a single display at a time, capable of replicating any iOS device without any required app/device, 4 nos. of USB3.0 port for connecting peripheral devices like keyboard & mouse, share uninterrupted HD video of 1080p @ 60 FPS, feature to stop someone else from presenting to enable uninterrupted presentation, an audio de-embedding feature, annotation & white board feature on both wired & wireless source connected, DHCP support, inbuilt/external Wi-Fi, feature to call the output view of the wireless presenter on any of the connected devices for viewing or annotation, file sharing option for all participants, minimum 32GB (SSD) inbuilt memory, file viewing/downloading option from inbuilt memory, Powerful security features: user authentication, 1024–bit encryption, dynamic room code, Certification: CE, ISO 9001, ISO 14001, OHSAS 18001 Extra component or equipment maybe added to match the complete specs.
Supply, Installation, Testing & installation of 5m High Speed HDMI cable for signals up to 4K@60Hz (4:4:4), Deep Color. Should have 24k gold Plated pins.Should support Bend Radius 90°. 30 AWG Cable.
Supply, Installation, Testing & installation of 3M High Speed HDMI cable for signals up to 4K@60Hz (4:4:4), Deep Color. Should have 24k gold Plated pins.Should support Bend Radius 90°. 30 AWG Cable.
Supply, installation, testing & commissioning of High quality shielded pair cable support balanced mono or unbalanced stereo mic or line level audio signals, Conductors and drain wire are stranded 20AWG tinned copper, rugged and flexible jacket with sequential markings every meter, Easy Stripping - Exceptionally easy to strip because the foil shield is bonded to the inside of the jacket, conductor size: 2x20AWG, conductor diameter: 0.916mm, Drain wire size: 20AWG tinned copper, Insulation material: Polypropylene, Insulation Diameter: 1.8±0.09mm, Screening material: AL–foil/mylar, Screening overlap: 25% minimum, Jacket material: PVC of diameter: 5.4 ± 0.19mm, Temperature rating: 75˚C, Conductor resistance: 20AWG–34.6Ω/KM MAX. at 20℃, Insulation resistance: DC–500V 100MΩ/KM MIN. at 20℃, Impedance: 40~100Ω, certification: UL: CM, RoHS: 2011/65/ EU.
Supply, installation, testing & commissioning of High quality Twisted pair cable, 23 AWG bare copper conductor, Insulation material: insulated with plenum rated PVC color coded red & black with sequential markings every Inches. Flame test UL 1685 (CM rated), RoHS compliant
Supply, installation, testing & commissioning of Connectors, Cable tie etc.
Supply, installation, testing & commissioning of ceiling microphone with patented beamforming technology ,Optimize your digital workflows with software. The microphone can be easily controlled and monitored from anywhere in the corporate network. For 100% connectivity - Connect the microphone via analogue or digital DANTE™ audio outputs to any conference system. Power-over-Ethernet (PoE) makes integration of the ceiling microphone very easy. An open media control protocol (API) allows you to make individual adjustments. With 28 x Sennheiser KE10 pre-polarized condenser capsule.1 x 3-pin terminals (Phoenix contact MCVW 1.5-3-ST-3.81); 2 x Digital Dante Network Audio (RJ45). The ceiling mounted microphone array shall be designed for fixed installation in medium to large conference rooms. The microphone array shall fit within the space of a standard 600 mm (2 ft.) ceiling panel and shall be mountable either onto or flush with the ceiling itself. Several mounting accessories shall be available, including a ceiling suspension kit, a ceiling fixation bracket as well as mounting brackets for US size ceiling panels and for 625 mm ceiling panels. Additionally, a VESA adapter shall be available for all standard 100 mm and 200 mm VESA mounting material.The microphone array shall consist of 28 Sennheiser KE 10-237 pre-polarized condenser microphone capsules and shall use beamforming technology that automatically focuses on whoever is speaking in the room. The beam will automatical?ly detect the position of the person speaking and will follow the person around the room at all times. A threshold for the detection shall be adjustable. Live monitoring of the horizontal and vertical angle of the position shall be available in the control software. The microphone array shall have a Dante™ interface with two RJ 45 sockets (Primary and Secondary) for digital audio output, supporting both redundant and daisy-chain modes. The microphone array shall also feature a 3-pin terminal for analog audio output, which is compatible with Phoenix contact MCVW 1.5-3-ST-3.81 connectors. In addition, the microphone array shall have an RJ 45 Ethernet socket for network control and easy configuration and mo?nitoring using the Sennheiser Control Cockpit control software. The RJ 45 Ethernet socket shall also support Power over Ethernet, using the PoE IEEE 802.3af Class 3 standard. 802.1X network configuration shall be possible via SSH protocol. The microphone array shall feature a reset button for restoring the factory settings. The microphone sensitivity shall be 0 dBV/Pa (988 mV/Pa). The maximum sound pressure level shall be 104 dB SPL. The dynamic range shall be 93 dB(A). The microphone dimensions (L x W x H) shall be 590 x 590 x 43 mm (23.2" x 23.2" x 1.7"), weight shall be 5670 g (12.5 lbs). The operating temperature shall range from 0 °C to +40 °C (+32 °F to +104 °F). The storage temperature shall range from -10 °C to 60 °C (14 °F to 140 °F). The microphone array shall be tested according to UL 2043 rating.
Supply, installation, testing & commissioning of 2ch Line output card. 32-bit digital to analog converters.
Supply, installation, testing & commissioning of 2ch input + 2ch output USB audio card. Occupies two (2) card slots.
Supply, installation, testing & commissioning of 8” programmable touch control, mounts into a US 2-gang box or included low voltage bracket. Portrait or landscape orientation. PoE powered, external power supply not included.
Supply, installation, testing & commissioning of 2-way Cabinet Loudspeaker, LF Driver 4” & HF Driver 1" Dome Tweeter; Max Power handling 70W @ 8 Ohms; Multiple 100V Taps : 24W / 12W / 6W; Frequency range 65Hz – 20Khz ; Sensitivity 86 dB and Max SPL 101 dB; Coverage of 130° x 130° (H X V) ; IP40 Rated; Operating Temperature -20°C to 60°C; ABS Plastic Housing with steel grill. Black
Supply, installation, testing & commissioning of Dual Channel Energy Star Rated Class D Amplifier , 2 X 150W @ 4Ω, 2 X 80W @ 8Ω, 1 X 300W @ 8Ω Bridge, Active Crossover,Protection Circuit : DC, Overheating, Overload, Signal limiting, XLR Line Inputs , 2-Pin Terminal Outputs , 1U 19" Rackmountable. The energy efficient stereo amplifier shall automatically switch to a standby mode when no audio signals are detected (less than 1Watt power consumption in standby mode). it shall use of Class-D technology ensures excellent efficiency as well as outstanding sound quality while ensuring maximum reliability. it shall have specific functions and advanced circuitry of optimal protection against DC malfunctioning, short circuit, overheating and overload. Signal input connections shall be integrated with balanced XLR connectors
Supply, installation, testing & commissioning of Video conferencing system with the following features Video standards: H.264 AVC, H.264 High Profile, H.265, RTV, H.239, H.264 video error concealment Support; Video Inputs:1 HDCI/1 HDMI/1 USB; VIDEO OUT: 2x HDMI, Touch display compatible; VIDEO RESOLUTION:{ Capable to support 4K, 30 fps (TX and RX) from 2048 Kbps, 1080p, 60 fps from 1740 Kbps, 1080p, 30 fps from 1024 Kbps, 720p, 60 fps from 832 Kbps, 720p, 30 fps from 512 Kbps, 4SIF/4CIF, 60 fps from 512 Kbps, 4SIF/4CIF, 30 fps from 128 Kbps, SIF (352 x 240), CIF (352 x 288), From 64 kbps, QCIF (176 x 144) from 64 kbps, w288p from 128 Kbps, w448 from 384 Kbps, w576p from 512 Kbps}: CONTENT VIDEO RESOLUTION { Input : UHD (3840 x 2160), HD (1920 x 1080p), WSXGA+ (1680x 1050), UXGA (1600 x 1200), SXGA (1280 x 1024), WXGA(1280 x 768), HD (1280 x 720p), XGA (1024 x 768), SVGA (800x 600).}; Output :{ UHD (3840 x 2160), WUXGA (1920 x 1200), HD (1920 x 1080), WSXGA+ (1680 x 1050), SXGA+ (1400 x 1050),SXGA (1280 x 1024), HD (1280 x 720), XGA (1024 x 768) }; { CONTENT SHARING: Poly Content App support, Apple Air Play, Miracast, 1x HDMI input} ; AUDIO INPUT: {Capability to support up to three 1x IP microphone arrays, Up to 4x Clink2 Microphones or Sound Structure }: AUDIO OUTPUT: { 1x HDMI, 1x 3.5 mm stereo line-out} ; OTHER INTERFACES: {3x USB , 1x USB-C, 1x RS-232, 8-pin mini-DIN, Bluetooth 5.0, WiFi 802.11a/b /g/n/ac (MIMO) Multichannel} ; AUDIO STANDARDS AND PROTOCOLS:{ 22 kHz bandwidth with Polycom Siren 22 technology, G.719 (M- Mode), 14 kHz bandwidth with Polycom Siren 14 technology, G.722.1, 7 kHz bandwidth with G.722, G.722.1, 3.4 kHz bandwidth with G.711, G.728, G.729A}; NETWORK: { IPv4 support, 1x 10/100/1G Ethernet, Auto- MDIX, 3x 10/100/1G LLN supporting POE+/PSE, H.323 and/or SIP up to 6 Mbps, Polycom Lost Packet Recovery (LPR)technology, Dynamic bandwidth allocation, Reconfigurable MTU size, RS232 with REST and CLI API support, Web Proxy support—Basic, Digest and NTLM, Simple Certificate Enrolment Protocol(SCEP)} , Single USB port functionality to use the system as an external camera, microphone and speaker when connected to a Laptop/PC.; SECURITY {Media encryption (H.323, SIP): AES-128,AES-256, H.235.6 support, Authenticated access to admin menus, web, interface and APIs, PKI /Certificate Management:- TLS 1.2, 1.1, 1.0, Self-signed and CA-signed certificate support, CRL and OCSP-based certificate revocation checking, Local account password policy configuration, Security profiles, Local account and login port lockout, Secure defaults, Remote logging with support for TLS
Supply installation testing and commissioning of 55 inch colour LED flat screen type professional-grade HD monitor / TV.
Supply, installation, testing & commissioning of 4 x 4 HDMI matrix switcher. Should have 4 HDMI inputs & 4 HDMI outputs. Should support resolution up to 4K@60Hz (4:2:0) & 4K@30Hz (4:4:4). Should have HDMI Deep Color, 3D,, up to 7.1 uncompressed audio channels. Should support HDCP 2.2 and HDMI 1.4a compliance. Should have Lock Button mechanisim for conneted HDMI Cables. Should have Flexible control options viz Front Panel,RS-232 & infrared remote control,
Supply, Installation, Testing & installation of Simultaneous Wired and Wireless Presentation and Collaboration Solution Wireless presentation device allows users with laptops or mobile to connect and present, HDMI input to connect a source with HDMI directly, 1 HDMI & 1 Mini DP/VGA output, one Gigabit LAN Ethernet port, audio de-embedding feature with one 3.5mm mini jack line out, Wireless Connection for up to 252 user devices, present minimum 4 users laptops or handheld devices on a single display at a time, capable of replicating any iOS device without any required app/device, 4 nos. of USB3.0 port for connecting peripheral devices like keyboard & mouse, share uninterrupted HD video of 1080p @ 60 FPS, feature to stop someone else from presenting to enable uninterrupted presentation, an audio de-embedding feature, annotation & white board feature on both wired & wireless source connected, DHCP support, inbuilt/external Wi-Fi, feature to call the output view of the wireless presenter on any of the connected devices for viewing or annotation, file sharing option for all participants, minimum 32GB (SSD) inbuilt memory, file viewing/downloading option from inbuilt memory, Powerful security features: user authentication, 1024–bit encryption, dynamic room code, Certification: CE, ISO 9001, ISO 14001, OHSAS 18001. Extra component or equipment maybe added to match the complete specs.
Supply, Installation, Testing & installation of 5m High Speed HDMI cable that supports signals up to 4K@60Hz (4:4:4), Deep Color. Should have 24k gold Plated pins.Should support Bend Radius 90°. 30 AWG Cable.
Supply, Installation, Testing & installation of 3m High Speed HDMI cable that supports signals up to 4K@60Hz (4:4:4), Deep Color. Should have 24k gold Plated pins.Should support Bend Radius 90°. 30 AWG Cable.
Supply, installation, testing & commissioning of High quality shielded pair cable support balanced mono or unbalanced stereo mic or line level audio signals, Conductors and drain wire are stranded 20AWG tinned copper, rugged and flexible jacket with sequential markings every meter, Easy Stripping - Exceptionally easy to strip because the foil shield is bonded to the inside of the jacket, conductor size: 2x20AWG, conductor diameter: 0.916mm, Drain wire size: 20AWG tinned copper, Insulation material: Polypropylene, Insulation Diameter: 1.8±0.09mm, Screening material: AL–foil/mylar, Screening overlap: 25% minimum, Jacket material: PVC of diameter: 5.4 ± 0.19mm, Temperature rating: 75˚C, Conductor resistance: 20AWG–34.6Ω/KM MAX. at 20℃, Insulation resistance: DC–500V 100MΩ/KM MIN. at 20℃, Impedance: 40~100Ω, certification: UL: CM, RoHS: 2011/65/ EU.
Supply, installation, testing & commissioning of High quality Twisted pair cable, 23 AWG bare copper conductor, Insulation material: insulated with plenum rated PVC color coded red & black with sequential markings every Inches. Flame test UL 1685 (CM rated), RoHS compliant.
Supply, installation, testing & commissioning of Connectors, Cable tie etc.
AUDITORIUM Supply, Installation, Testing & installation of 2-way Cabinet Loudspeaker, LF Driver 12” & HF Driver 1" Compression driver ; Max power handling 600W @ 8 Ohms ; Frequency range 55Hz – 20Khz ; Sensitivity 100 dB and Max SPL 125 dB; Coverage of 90° x 75° (H X V) ; IP40 Rated; Operating Temperature -20°C to 60°C; MDF Cabinet. Mounting Bracket optional (MBK). Black (FOH)
Supply, Installation, Testing & installation of Mounting bracket for the above speaker
Supply, Installation, Testing & installation of 2-way Cabinet Loudspeaker, LF Driver 12” & HF Driver 1" Compression driver ; Max power handling 600W @ 8 Ohms ; Frequency range 55Hz – 20Khz ; Sensitivity 100 dB and Max SPL 125 dB; Coverage of 90° x 75° (H X V) ; IP40 Rated; Operating Temperature -20°C to 60°C; MDF Cabinet. Mounting Bracket optional (MBK). Black (SM)
Supply, Installation, Testing & installation of 2-way Cabinet Loudspeaker, LF Driver 8” & HF Driver 1" Compression driver Max Power handling 350W @ 8 Ohms ; Frequency range 55Hz – 20Khz ; Sensitivity 92 dB and Max SPL 115 dB; Coverage of 100° x 80° (H X V); IP40 Rated; Operating Temperature -20°C to 60°C; MDF Cabinet. Black
Supply, Installation, Testing & installation of Bass Reflex Subwoofer, 1 X 15" Ferrite with Low loss suspension LF Driver & 1.5" 4-Layer wounded Voice Coil; Max Power handling 1400W @ 8 Ohms ; Frequency range 34Hz – 1Khz ; Sensitivity 99 dB and Max SPL 127 dB; Nominal Impedance : 8 Ohms; Operating Temperature -20°C to 60°C ; Plywood Cabinet enclosure; Output Terminal Speakon (with Link Through); M6 / M10 Rigging Points on Cabinet.
Supply, Installation, Testing & installation of 2ch Line output card. 32-bit digital to analog converters.
Supply, Installation, Testing & installation of 2ch input + 2ch output USB audio card. Occupies two (2) card slots.
Supply, Installation, Testing & installation of UHF Wireless Handheld Microphone A wireless RF transmission system designed for presentation use and other applications where maximum speech intelli?gibility is required. The system shall consist of a stationary receiver, a handheld transmitter and a condenser microphone head. The system shall operate within ten UHF frequency ranges, with a switching bandwidth of up to 88 MHz: 470 – 558 MHz, 520 – 558 MHz, 558 – 608 MHz, 558 – 626 MHz, 606 – 678 MHz, 626 – 698 MHz, 718 – 790 MHz, 790 – 865 MHz, 806 – 810 MHz, 925 – 937.5 MHz; receiving frequencies shall be 3520 per range and shall be tunable in 25 kHz steps. The system shall feature 20 fixed frequency banks with up to 32 compatible frequency presets and 6 user banks with up to 32 user programmable frequencies.The receiver shall be menu-driven with a backlit OLED display showing the current frequency, frequency bank and chan?nel number, metering of RF level, metering of AF level, lock status, pilot tone evaluation, muting function, and battery status of the associated transmitter. An auto-lock feature shall be provided to prevent settings from being accidentally altered. The receiver shall provide a sound check mode. Some receiver parameters such as receiving frequency, receiver name and pilot tone setting shall be synchronizable with the associated transmitter via an integrated infrared interface. The receiver shall feature a balanced XLR-3M audio output with a maximum output of +18 dBu along with an unbalanced ¼“ (6.3 mm) audio output with a maximum output of +12 dBu. A headphone output with headphone volume control shall be provided and shall utilize a ¼“ (6.3 mm) stereo jack socket. The receiver shall have an Ethernet port (RJ-45) for remote network-based monitoring and control software. Two BNC-type input sockets shall be provided for connecting the antennas.Nominal/peak deviation shall be ±24 kHz/±48 kHz. Squelch threshold shall be defeatable (off) or adjustable from 5 - 25 dBμV in steps of 2 dB
Supply, Installation, Testing & installation of UHF Wireless Lavalier Microphone it shall have a wireless RF transmission system designed for presentation use and other applications where maximum speech intelli?gibility is required The system shall consist of a stationary receiver, a handheld transmitter and a condenser microphone head. The system shall operate within ten UHF frequency ranges, with a switching bandwidth of up to 88 MHz: 470 – 558 MHz, 520 – 558 MHz, 558 – 608 MHz, 558 – 626 MHz, 606 – 678 MHz, 626 – 698 MHz, 718 – 790 MHz, 790 – 865 MHz, 806 – 810 MHz, 925 – 937.5 MHz; receiving frequencies shall be 3520 per range and shall be tunable in 25 kHz steps. The system shall feature 20 fixed frequency banks with up to 32 compatible frequency presets and 6 user banks with up to 32 user programmable frequencies. The receiver shall be menu-driven with a backlit OLED display showing the current frequency, frequency bank and chan?nel number, metering of RF level, metering of AF level, lock status, pilot tone evaluation, muting function, and battery status of the associated transmitter. An auto-lock feature shall be provided to prevent settings from being accidentally altered. The receiver shall provide a sound check mode. Some receiver parameters such as receiving frequency, receiver name and pilot tone setting shall be synchronizable with the associated transmitter via an integrated infrared interface. The receiver shall feature a balanced XLR-3M audio output with a maximum output of +18 dBu along with an unbalanced ¼“ (6.3 mm) audio output with a maximum output of +12 dBu. A headphone output with headphone volume control shall be provided and shall utilize a ¼“ (6.3 mm) stereo jack socket. The receiver shall have an Ethernet port (RJ-45) for remote network-based monitoring and control software. Two BNC-type input sockets shall be provided for connecting the antennas. Nominal/peak deviation shall be ±24 kHz/±48 kHz. Squelch threshold shall be defeatable (off) or adjustable from 5 - 25 dBμV in steps of 2 dB
Supply, Installation, Testing & installation of UHF Wireless Head Mic Microphone it should be awireless RF transmission system designed for presentation use and other applications where maximum speech intelli?gibility is required.The system shall consist of a stationary receiver, a handheld transmitter and a condenser microphone head. The system shall operate within ten UHF frequency ranges, with a switching bandwidth of up to 88 MHz: 470 – 558 MHz, 520 – 558 MHz, 558 – 608 MHz, 558 – 626 MHz, 606 – 678 MHz, 626 – 698 MHz, 718 – 790 MHz, 790 – 865 MHz, 806 – 810 MHz, 925 – 937.5 MHz; receiving frequencies shall be 3520 per range and shall be tunable in 25 kHz steps. The system shall feature 20 fixed frequency banks with up to 32 compatible frequency presets and 6 user banks with up to 32 user programmable frequencies. The receiver shall be menu-driven with a backlit OLED display showing the current frequency, frequency bank and chan?nel number, metering of RF level, metering of AF level, lock status, pilot tone evaluation, muting function, and battery status of the associated transmitter. An auto-lock feature shall be provided to prevent settings from being accidentally altered. The receiver shall provide a sound check mode. Some receiver parameters such as receiving frequency, receiver name and pilot tone setting shall be synchronizable with the associated transmitter via an integrated infrared interface. The receiver shall feature a balanced XLR-3M audio output with a maximum output of +18 dBu along with an unbalanced ¼“ (6.3 mm) audio output with a maximum output of +12 dBu. A headphone output with headphone volume control shall be provided and shall utilize a ¼“ (6.3 mm) stereo jack socket. The receiver shall have an Ethernet port (RJ-45) for remote network-based monitoring and control software. Two BNC-type input sockets shall be provided for connecting the antennas. Nominal/peak deviation shall be ±24 kHz/±48 kHz. Squelch threshold shall be defeatable (off) or adjustable from 5 - 25 dBμV in steps of 2 dB
Supply, Installation, Testing & installation of Active antenna splitter built in a full metal housing and ships with 8 BNC cables included. The splitter shall run up to 4 receivers with two antennas. It shall havce the following features • Compatible with G4 and G3 systems ; Power supply via BNC cables ; No additional power supply needed; Up to 4 true diversity receivers can be used with two external antennas; Full metal housing
Supply, Installation, Testing & installation of UHF Passive directional antenna Passive directional transmitting and receiving antenna. Frequency range: 450-960 MHz; Apex angle: approx. 100°; Front-to-back ratio: ≥ 14 dB
Supply, Installation, Testing & installation of a pre-polarized condenser microphone designed for permanent installation or portable applications. It shall have a microphone capsule with a car?dioid polar pattern with uniform 120° angle of acceptance (-3 dB). The microphone shall include a green lighted LED ring below the capsule for indicating the activity of the microphone. It shall have a frequency response of 50 Hz to 20,000 Hz and be capable of handling sound input levels up to 130 dB SPL. Nominal equivalent noise level shall be 26 dBA (37 dB weighted as per CCIR 468-3). Output shall be low impe?dance balanced (< 100 Ω). Operating temperature shall be 0 °C to 40 °C (32 °F to 104 °F). The microphone shall operate from an external 12 V to 48 V DC phantom power source; current consumption shall be 3 mA. The lighted LED ring shall operate from an external 8 – 30 V AC or DC power source; current consumption shall be 3 mA. The microphone shall offer radio frequency interference (RFI) shielding against intermodulation from wireless equipment or devices. The microphone shall be a gooseneck design ensuring precise alignment of the microphone. It shall incorporate a self-contained power module with an XLR-5M connector at the base, which includes connection for the lighted LED ring power supply. The microphone shall be a small-diame?ter gooseneck design with a diameter of 8 mm (0.31") and an overall length of 457.2 mm (18"). Head diameter shall be 22.8 mm (0.9"). The microphone weight shall be 147 g (4.72 oz). Finish shall be matte black.
Supply, Installation, Testing & installation of The table stand for connecting and operating XLR gooseneck microphones shall be rugged and unobtrusive. It shall have a programmable microphone button (Toggle on/off, PTM, PTT and permanent on) and a bi-color LED ring for status indication shall be provided. The table stand shall feature an XLR-5F microphone input, an XLR-3M microphone output and a TTL logic connector with logic inputs and outputs. The logic output voltage shall be high level > 2.4 and low level < 0.4 V, the logic in?put voltage shall be high level > 2.0 V and low level < 0.8 V. The table stand shall operate on 48 V phantom power. Current consumption shall be 3.7 mA. Dimensions shall be 120 x 170 x 43 mm (4.72" x 6.69" x 1.69"). Weight shall be 1,200 grams (42.33 oz). Operating temperature shall range from -10 °C to +50 °C (+14 °F to +122 °F)
Supply, Installation, Testing & installation of 16-Channel Mixing Console. Low-noise, high-headroom analog mixer Six phantom-powered Mic Preamps comparable to stand-alone preamps; Six studio-grade compressors with easy "one-knob" functionality; Built-in stereo USB audio interface lets you connect directly to your computer; Neo-classic "British" 3-band EQ for warm and musical sound; 9-band stereo graphic EQ allows precise frequency correction of monitor or main mixes; FBQ Feedback Detection System instantly reveals critical frequencies; XPQ 3D stereo surround effect for more vitality and enhanced stereo image; Voice Canceller function for easy-to-use sing-along applications; 24-bit Klark Teknik FX processor with 100 presets, including; Reverb, chorus, flanger, delay, pitch shifter and various multi-effects; Three aux sends per channel:One pre-fader for monitoring applications; One pre/post-fader switchable for monitoring/FX; One post-fader for external FX devices; Two multi-function stereo aux returns with flexible routing; Two subgroups with separate outputs for added routing flexibility; Balanced main mix outputs with gold-plated XLR connectors; Separate control room, headphones, and 2-track outputs; Clip LEDs, mute, main mix and subgroup routing switches, solo and PFL functions on all channels ; "Planet Earth" switching power supply delivers: 100V-240V flexibility; Noise-free audio and superior transient response; Low power consumption for energy savings
Supply, Installation, Testing & installation of 8,500 lumens-class compact Solid Shine laser projector designed for intensive usage and long-lasting brightness for education, museums, exhibitions, and digital signage. Up to 20,000 hours maintenance-free, Digital Link, 10,000:1 contrast ratio, 360° flexible installation.
Supply, Installation, Testing & installation of 200" Motorized Tab-tensioned projection screen Elegant Hexagonal shaped housing. High contrast Matte White Fabric.Tubular Motor with 3 in 1 remote. View angle >160 °
Supply, Installation, Testing & installation of 2C X 4 sq.mm sheilded Speaker Cable
Supply, Installation, Testing & installation of Sheilded Cable for Mic
Supply, Installation, Testing & installation of various Connectors as required for interconnection
Supply, Installation, Testing & installation of HDMI Cable with male/female 19pin HDMI connectors as per requirements complete
Supply, Installation, Testing & installation of TSRX.
BMS Software Supplying, installation, testing and commissioning of IBMS Server Software suite: Multi Descipline Integrated BMS (IBMS software like HVAC control , Fire Alarm system, Access control system , CCTV monitoring system , ETC). The client license provided shall display actual graphics as represented in the server machine. Should be capable of interfacing with Bacnet/IP based DDC controllers, Bacnet/IP or modbus RTU 3rd party interface. Software shall have minimum 3 client license and 3500 Data points and expandable upto 5000 Data Points. Software should include atleast 5 years maintenance fee.Software should be capable to interact with SQL database. Software should have open protocols point with OPC client connectivity. Complete with Webserver for IBMS interface on Internet / Intranet. Software should have the following Key features: 1. High End Vector Graphics in 2D, 3D, DIN or DIN+ format. 2. Software should support for BACnet, OPC, Modbus, HTTP(S), SNMP, M-bus, KNX, IEC61850, HTML5, Haystack, Power, Power Quality, and S7 and S7 Plus standards 3. Native 64 bit system which supports latest IP technology (IP V4/V6). 4. Mobile access on Android/ iOS. 5. .Net Platform which compliance to latest IT trends in the market. IT security compliant with the ISA-99/IEC 62443 SL-1 for cyber security. 6. Software shal have feature of providing data to external applications and services via standard protocols (OPC and web services) 7. Software shall be able to communicate with BACnet & Modbus IP simultaneously withour any external hardware like protocol / integration convertor / controller. 8. Multi parameter trend should be configured. Trend Comparison for same parameter with graphical as well as tabular representation. 9. Assisted treatment of alarms which helps in Predefined & fast intervention steps for faster response. Alarm Escalation. 10. Import Auto Cad drawing directly. Autocad import of plan with Zoom In & Zoom Out facility through scroll mouse feature. 11. Energy dashboards having cockpit view of total energy utilized. Energy and Power reports. 12. SCADA Platform based software having Robust, Flexible and Reliable with multiple drivers for integrations with PLCs, ease of use in the industrial environment. 13. Seamless Integrated environment for advanced fire system management - UL Standards/EN Standards. 14. Online engineering should possible, including data discovery, CAD import, and automatic positioning of graphic symbols. Local and remote (web) engineering with full capabilities. 15. Reports - Customised reports for offline Trending and alarm with Graphic screen shots, Third Party System - Trending and Alarm Configuration for Third Party system. All required Software with original license competent with BMS software.
Supply, installation, testing and commissioning of hand held portable operator terminals.(POT) 10 inch. TFT display with capacitive touch screen type, shall be able to view graphs , alarms , parameters etc. POT shall have integrated web server and a BACnet/ IP web interface to connect a HTML5 browser to a device on the network. POT With all required connectors etc as per technical specification etc.
SITC of DDC Controller for Chiller Plant Room (Chiller, Pumps)
SITC of DDC Controller for Cooling Tower
SITC of DDC Controller for AHU (1 AHU/ Controller)
SITC of DDC Controller for FCU (5 FCU/ Controller)
SITC of DDC Controller for TFA (1 TFA/ Controller)
SITC of DDC Controller for Plumbing
SITC of DDC Controller for Fire Fighting
SITC of DDC Controller for Electrical HT/ LT Breaker
SITC of DDC Controller for DG
SITC of DDC Controller for Liftwell/ Lift Lobby Pressurization Fans
SITC of DDC Controller for Smoke Extraction Fans
SITC of DDC Controller for STP Ventilation
SITC of DDC for Basement Ventilation
SITC of DDC for Security System
Supply & install Bacnet Gateways for IP BASED Open protocol INTEGRATOR for CPO (TCP/IP , Bacnet /IP), VFD, Automatic Chemical Dosing, DG, Lifts, Escalators, ventilations, security systems with Inbuilt web browser, multiprotocol supported & should be of the same make as the DDC.Integrator should communicate on Modbus/IP and Modbus over RS485/RS232 concurrently.It should be possible for remotly restart and access all the functionality of integrator having 2 ethernet port. .
SITC of Air Differential Pressure switches the for indicating the Filter status in Air able to measure pressure at zero pascal pressure, 50-500 Pascal minimum pressure range, IP 54 rated, UL Listed.
SITC of Outdoor type Ambient Temperature with Humidity Sensor with radiation shield , IP65 rated (Temp Range -40 to +70 °C, RH : 0-100 %) UL Listed
SITC of Differential Pressure sensor for input to VFD in the AHU
SITC of Immersion Temperature Sensor of 150mm, IP 54 rated RTD type Range of temp -30 to 130°C) with Thermowell, UL Listed
SITC of Pump Run status (DPS across the pump)
SITC of Air Type Differential Pressure Transmitter (Range 0-1000Pa) for VFD pumps
SITC of Water Type Flow Switch having PN25 nominal pressure , (Temp range -20 to 80 °C) IP65 Rated, Brass valve body, Adjestable paddle without extra element.
SITC of Water Pressure Sensor,UL Listed
SITC of Water Bi- Level Switch,UL Listed
SITC of Outside Air CO2 Sensor,UL Listed
SITC of Duct Mount Temp. & RH Sensor,UL Listed
SITC of Flameproof Bi- Level Switch
SITC of Voltage Transducer
SITC of Duct CO2 Sensor,UL Listed
Supplying, installing, testing and commissioning of PVC Sheathed, insulated, Copper Conductor, 2 C x 1.0 Sqmm, armored, shielded twisted pair, signal cabling for connecting field devices
Supplying, installing, testing and commissioning of PVC Sheathed, insulated, Copper Conductor, 4C x 1.0 Sqmm, armored, shielded twisted pair, signal cabling for connecting field devices
Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No.WG-COC/NC
Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying, installing, testing and commissioning of 2 pair x 1.5 mm² screend twisted pair cable, with 1mm Annealed tinned copper & drain wire as per specification including glands, lugs, terminations on both end, flexible GI conduit for final termination as required. Cables as Tagged under "A20" of BH-A-SM-E-8001 in terrace in protective trunking.
Supplying and erecting PVC box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX .
Supplying and erecting PVC box trunking of size 50x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX.
Supplying, erecting & terminating XLPE armoured cable 3 core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no CB-LT/CU
SITC of FO Cable to CAT6 Converter
Supplying & erecting mains with 1x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW( For earthing for BMS Panels, SMPS / equipment safety)
Supply , instllation of Central Computer System - Intel Core i7-3770 Processor (up to 3,3 GHz), Quad-Core,16 GB RAM, 2 TB Hard disk, DVD Double Layer Burner, USB 3.0, NVIDIA GeForce GT640 Graphic card (3072 MB), HDMI, Windows 7 64 Bit, 32" LED Monitor , Optical Mouse, 104 Keys Keyboard including A4 colour Office jet printer.
Supply , instllation of a printer conforming to Contract Specificaiton to have all the proprietry / licensed drivers to work with the PC proiided unders these works. Unit to come with control cables necessary for connection to PC plus have a spare RJ45 port.
Supply , instllation of Network Switches required for completion of IT networking required for BMS Integration & DDC Connection with BMS Software
SITC of VDE 0834 approved Nurse calling Station decentralized communication node of a nurse call system for data exchange and power supply of the connected devices having separate bus supporting IP capable end all other system modules comprising of 1 no RJ45 socket, 100Mb IP Port (IEEE802.3 100BaseTX), galvanically isolated conforming to EN 60950 and VDE 0834, 7 x RJ45 sockets, each for a 100Mb IP system port (IEEE802.3 100BaseTX) for connecting all IP capable system modules with Control LEDs for indicating the current operating state; 4 Nos. RJ45 sockets for connection of the external data bus; POE IP modules and having required terminals for 24V DC supply voltage.
SITC of VDE 0834 approved VOIP Nurse Station based on a controller and FlashProm, 100BaseTX interface to the system switch, PC interface to the communications control panel, 2.8m connection cable with an RJ45 connection plug, which is protected, from disconnection, for connecting to a connection module with a 7“ large LCD 480 × 800 backlit colour touch screen , inbuilt SIP Phone, consisting of Set presences (green, yellow, blue),Call releasing (emergency call, doctor call, heart alarm etc.),Control interconnections & centralisation of wards, Managing care groups and call prioritisation of individual beds with hands-free and discrete speaking capability & displaying date and time, indication of all presence, all set reminders, indication of all calling stations ,Operating voltage: 17.5 – 30 V DC, Power consumption: 369.6 mA at 8,500 mW typ., Interfaces/system connection: 1 × Self disconnecting socket or plugs for plugging into an IP connection module (LAN interface with PoE), Protection class: IP 32, VDE 0834 Environmental class II, Ambient temperature: +5 °C to +40 °C, Relative air humidity: up to 95 % without condensation, Case: Plastic ABS, white RAL 9016
SITC of VDE 0834 approved Patient Handset without Speech Complete with Germ inhibiting membrane keypad, two call buttons with mechanical trigger., self-disconnecting plugs, Call button with nurse symbol with integrated finder and reassurance light on the top end of the unit with call key, lighting keys, 2.80 metre connection cable with auto-disconnecting RJ45 connector plug along with a clip.
SITC of VDE 0834 approved connection module with sockets for Patient Terminal with diagnostic socket, self-disconnecting socket, call and cancel button and four ports for connecting basic components or modules of a diagnostic device with safe isolation in accordance with DIN EN 60601-1 , Self-disconnecting socket for connecting a non-voice patient handset, Germ inhibiting membrane keypad with Answering button with status LED, Call button with locating and reassurance light, Rear basic interface for the connection of basic connection modules like code blue button or basic Light modules or toilet module or WC module, Connection module for patient handset shall consist of: with Germ inhibiting, 1 x RJ45 socket marked in colour and with measures to ensure that the push button is correctly connected, including auto disconnect mechanism , 1 membrane keypad with:- 1 call button including a finder/reassurance light, 1 presence key cum cancel button including a control LED, 1 DIN port for co connecting Medical devices
SITC of module providing DVI output consisting of hardware interface for the connection of one or two monitors for use as onscreen indicators (grouped indication of calls and reminders), with alphanumeric indication of the call location guides the staff to the location by the shortest route, complete with surface-mounted housing , countersunk mounting, a double connection box installed in the wall , 2 DVI-D sockets with the same image on both sockets, passive DVI-HDMI adapter , Image output with 1280 × 720 pixels and 60 Hz (720p60), call indication & reminders of several rooms under consideration of call priorities; alphanumeric indication of group/ward, room and bed in multicolour , simultaneous indication of two calls or reminders In case of more than two calls, all calls will be indicated alternately, Date & Time display, integrated sound generator for signaling
SITC of 20 “ LED-backlit LCD monitor of 1600 x 900 Resolution at 60 Hz, Aspect Ratio 16:9, Pixel Pitch : 0.27 mm, Contrast Ratio 1000:1, 16.7 million colours Support, DisplayPort 1.2, HDCP 1.2 Brightness 250 cd/m with a anti reflection coating
SITC of VDE 0834 approved Code Blue Call consisting of pushbuttons for call forwarding, for releasing calls and setting and deactivating code blue presences . , equipped with locating and reassurance light and status LED., media duct & wall mounting capability, countersunk mounting, wall mounted switchbox., supporting call forwarding for set presences with an Integrated sound generator for signalling , Germ inhibiting membrane keypad with Answering button with status LED & Doctor call or code blue button with locating and reassurance light with a piezo buzzer complete with installation frame for screw-free attachment & countersunk backbox
Supply of VDE 0834 approved fast-exchange 2 meter pull cord with snap hook consisting of pushbuttons for releasing calls with a pull cord, Equipped with moisture-proof circuit board and a locating and reassurance light, green presence or cancel button , Media duct as well as wall mounting capability complete with grip with nurse symbol, Microswitch with 2 meter pull cord, along with installation frame for screw-free attachment with countersunk back box.
Supply of VDE 0834 approved Lamp Module consisting of four indicator fields for colour-coded indication. 4 light chambers with light reflectors for homogeneous illumination with ultra bright red ,white green ,blue LED
SITC of Supply of Management centre rack mountable Management Server with the following configuration: Intel Xeon 3220 2,4GHz or equivalent, 2 GB RAM, 1 x 160GB HDD, 1 x DVD hard drive, 2 x Gbit LAN Ethernet RJ45, 1 x serial connection RS232 and 2 x USBV2.0, 1 x PCI or 1 x PICe socket, support for SUSE Linux enterprise Server from V10.1 including operating system connected via the network of backbone switches for connection with external systems like alarm server, fire alarm system, dementia , Safety system, VDECT, telephone server having a dongle protected software licenses, Central import of updates, Automatic configuration of components when plugged, Operation of a ward and centralised control panel, Using Audio Manager, Patient management, System Monitor.
Supplying, fixing, and configuring Managed L2 Power over Ethernet Switch of 20 Ports + 4G Combo Port as per specification complete.
Supplying, fixing, and configuring layer 3/ 20 10/100/1000 base-T ports + 4 combo 10/100/1000Base-T/SFP ports + 4 10GE SFP+ ports - SI Image as per specification complete
SITC of one time licenced Event Database for automatically logging all real time events in the entire communications system, such as, e.g., calls, presence markings, call acknowledgements, reminders.
SITC of Central Monitoring S/w for monitoring all the nurse station calls at central location with GUI option With Latest Config PC + Monitor
SITC of Software licence to forward the important Events from nurse call systems to Hospital EPABX i.e unified communication system using SIP Protocol for interfacing.
Supplying & installing UTP networking cat-6 cable with rodent proof jacket suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC
Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting SMPS with input voltage 230 V A.C. & output voltage 24 V DC, charging current 7 A suitablewith necessary connecting wires.
SITC OF VDE 0834 complied IO BUS pushbuttons with two status LED.( Green / yellow ), media duct & wall mounting Capability with a Germ inhibiting antimicrobial membrane keypad with Answering buttons with Green & Yellow status indication, 2 x RJ45 sockets for connecting to the IO bus complete .
SITC OF VDE 0834 complied cancel & Presence buttons with two status LED.( Green / yellow ), media duct & wall mounting Capability with a Germ inhibiting antimicrobial membrane keypad with Answering buttons with Green & Yellow status indication, 2 x RJ45 sockets for connecting to the IO bus complete
Supplying, Installation, Testing & Commissioning of Front-Loading designed microprocessor controlled Pneumatic tube Station Units with full RFID functionality, track and tracing of the carriers Operational on 60 Volt DC or lee with double shielded cables complying with the relevant EMC regulations with an in built LCD Display showing time Date, Destination, last carrier arrived from, fault indication etc, with wipeable membrane keypad & manufactured from hygienic ABS closed cell materials with smoked acrylic door with an ergonomic working height for all users. automatic speed reducing facility , capability of automatically returning the carrier to the sender once the receiving department removes the items receives and places the carrier back in the station., vertically single-side usage, automatic carrier departure without manually opening a door or pressing a start-push-button., fully-integrated carrier deceleration. Open receiving basket fixed under the station for Delivery of the carrier , fully automatic computer-controlled and the PC serves as a control and supervising centre that controls and monitors all transmissions within the whole system on a continuous basis. Supporting multiple languages, complete with telephone type key pad,4 lined display, function indication, arrival signification, service mode and repetition control
Supplying, Installation, Testing & Commissioning of microprocessor-controlled Auto unload station of 160mm size with dual channel connection with full RFID functionality, fully-integrated carrier deceleration Operational on 60 Volt DC or less with double shielded cables complying with the relevant EMC regulations having capability of automatically returning the carrier to the sender from the separate line once the samples drop automatically and carrier back in the sending port complete with Maintenance-free sensors and reed contacts
Supplying, Installation, Testing & Commissioning of Stations accessories like carrier arrival basket & cabinet of sufficient size, A lockable variant of the basket for public areas, carrier-rack for wall installation, horizontally storage of up to 5 carriers, Durable damping cushion Receiving Basket & a receiver basket with 4-5mm spokes finished with grey nylon and including a natural rubber damping matt & a recess for a tube duct Installation: wall or floor
Supply, Installation, Testing & Commissioning of Microprocessor based Central Control Unit capable of controlling monitoring all transmissions within the system on a real-time basis having an Intel 16 bit processor having ROM loaded Software capable to operate all station through SELV (separated extra-low voltage)., providing analysis the system day to day operations having real time monitoring and lithium ion battery to store operational data in event of power failure, 2 Nos. of RS232 with latest version Personal computer supporting the installed Windows version operating system with a 1 TB HDD, ethernet card and a 19” flat screen, with an indication of fault status, location of faulty station with alarm report generation feature., BMS connectivity, Fire Alarm Connectivity, capability to immediately stop blowers in case of a fire, The control software must be continuously monitors all sensors, switches, motors and other components, and gives early warning should the performance of any component start to degrade & provides full analyses based on self-created log files, Graphical representations of the system schematics together with the operating status of all zones and monitoring and carrier flow , a record of easily exportable log files stored in the hard disk for at least 3 months along with a simulation mode for training and testing, System-data, Topography and non-volatile memory for power-failure protection, potential-free contact for collective reports and Data-protection by code-number.
Supplying, Installation, Testing & Commission additional Power Supply for Voltage regulation having 115/230 Volt AC-input, 1 x 42 Volt DC-output, 4 A with short-circuit-proof with electronic fuse having IP 40 protection & prevention any voltage drops during operation of the system.
Supplying, Installation, Testing and Commissioning of 6 Way Diverter sealed with maintenance-free Teflon-bushings., fitted with a reliable industrial grade motor with overcurrent- release, radio-screened., Indication and as a standard connection for monitoring device and remote operation., having a solid Aluminium frame with heavy duty plastic covers with a provision to be installed in many positions with Diverter. Direct gear driven drive mechanism capable of moving carriers from one tube to another within the system with a minimum of shock, noise and vibration with Self-controlling and self-positioning mechanism that prevents the diverter to jam or lock.
Supplying, Installation, Testing and Commissioning of 3 Way Diverter sealed with maintenance-free Teflon-bushings., fitted with a reliable industrial grade motor with overcurrent- release, radio-screened., Indication and as a standard connection for monitoring device and remote operation., having a solid Aluminium frame with heavy duty plastic covers with a provision to be installed in many positions with Diverter. Direct gear driven drive mechanism capable of moving carriers from one tube to another within the system with a minimum of shock, noise and vibration with Self-controlling and self-positioning mechanism that prevents the diverter to jam or lock.
Supplying, Installation, Testing & Commissioning of Three-phase-blower having minimum air volume capacity of 8,83 m³/min, 4.6kW for air-supply of the system to achieve transport speed of at least 6 m/sec having Connecting-socket for fresh-air-suction included with 2 nos. of silencers of each blower with a heavy duty maintenance-free motor operated fully adjustable 5 positioning valve, to provide one system line with variable suction and pressure air. NO air diverter will be allowed to change the air., operational only during carrier transaction and remains idle otherwise, direct fitted air tubes with a silencer (s) for less noise emission& a contractor and thermal protection, IP54 protection.
Supplying, Erection, Testing & Commissioning of 5 zone linear coupler smart multi storage system conforming to CE standard guideline 2006/42/EC for mechanical engineering and the EMC standard 2004/108/EG with a system capacity up to 500 carriers per hour and configured to integrates all priority and slow speed transactions., silent and shockproof transport, suitable for blood transport and other bio hazard materials., designed for intensive use & Long lifespan, easy installation. , service and maintenance friendly with low energy consumption & should be further expandable up to 10-line steps of 5 with the same software.
Supplying, Erection, Testing & Commissioning of DIN 6660 / 666 certified Dispatch Tube having a outer diameter of 160 mm with internal diameter of 153.6mm and with minimum radius curvatures of 800 mm made of fire resistant Weather-proof, Wear-resistant, Sound absorbing, PVC-U according to class B1 with Special surface treatment for polished inside and outside wall with accessories such as fastening tube clamps, cable strips fitted with Motion detectors directly installed on tubes along the networks for tracking
Supplying, Erection, Testing & Commissioning of DIN 6660 / 6661 certified dispatch tube Bend NW 160mm having a Radius of 800mm with a 90 degree angular positionmade of Weather-proof, Wear-resistant, Sound absorbing, Hard-PVC-U according to class B1 with Special surface treatment for polished inside and outside wall with accessories such as fastening tube clamps, cable strips etc. complete.
Supplying, Erection, Testing & Commissioning of UPVC Sleeves NW160mm fixing the tube joints, diverters etc. to the tube run made of Weather-proof, Wear-resistant, Sound absorbing, Hard-PVC-U according to class B1 with Special surface treatment for polished inside and outside wall with accessories such as fastening tube clamps, cable strips etc. complete.
Supply & Erection of SS steel galvanized tube clamps with screw M6 x20 and square nut with 8 mm thread rod for mounting
Supply & Installation of 1.5 sq.mm 6 cores shielded, twisted & paired FRLSH control cable with twisted pairs data +/-20 pitches per meter and power +/-20 pitches per meter which leads good cross talk attenuation values in a unit. Temperature range: stationary: +70 degree Centigrade. Stationary: -5 degree C to + 50 degree Centigrade., Conductor resistance shall be: data pair max- 116 Ohm/km (loop); power lines max: 45Ohm/km (loop), Insulation resistance; > 1000 MOhm/km, - Test Voltage – 1500 V DC, - Working voltage – data pair: 5V max & power lines 48V DC max. , - Cable structure – Data pair: tinned copper standed wires AWG22 97x0,3 mm) (0,49 mm2), - Power lines: tinned copper standard wires AWG18 (7x0,4mm)(0,88mm2) , - Core insulation: data pair – Polyethene MS:314; Power lines : PVC- Cross twisted in pairs – Data pair: +/25 pitch /m & power lines: +/-20 pitch/m. 2 electro static screens of aluminium on Mylar polyester foils and drain wire tinned, (10x0,25) (0,49mm2) , Outer Jacket, extruded PVC compound colour grey. , Core Colours: Data pair: a-core white, b-core black; power lines: a-core red, b-core red/white
Supplying & installing Pneumatic Tube carrier having Robust / tough "swivel top" design, with coloured ends, and transparent body with Payload max.5 kg with 1/2 x swivel cap compatible to use in tube with radius ≥ R800 bends. made of material for casing / absorbers / slide rings –U-PVC with swing Lid opening having a built-in RFID tag for "Automatic Empty Carrier Return” facilities available., The normal speed of the transporting carrier shall be 5-6 m/s and blood samples & delicate items shall be 2-3 m/s., available in both long and short sizes.
Supplying & installing TNO Notified Certified body Leak-proof Carriers of size 160mm that certified by a (TNO) notified body..
Supply,installation,testing and Commissioning G.I. pipe above ground of „C‟ class ERW of size 25 mm dia with necessary fittings complete as per specification no. FF-PP
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 32mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 40mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 50 mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 65 mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 75/80 mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 100mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 150mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning of 15mm(1/2'') dia NBCM Body chrome finished quartzoid bulb pendent sprinkler having 68 C fixed temperture rating with deflector disc of conventional construction as per specification No FF-SPR
Supply,installation,testing and Commissioning of 15mm(1/2'') dia NBCM Body chrome finished quartzoid bulb Upright sprinkler having 68 C fixed temperture rating with deflector disc of conventional construction as per specification
Supply,installation,testing and Commissioning of 15mm(1/2'') dia NBCM Body chrome finished quartzoid bulb Side Wall Upright sprinkler having 68 C fixed temperture rating with deflector disc of conventional construction as per specification
Supply,installation,testing and Commissioning of cast iron double flange butterfly valve of size 150 mm dia. complete as per specification no. FF-VL/BFV
Supply,installation,testing and Commissioning of cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF-VL/BFV
Supply,installation,testing and Commissioning of cast iron double flange butterfly valve of size 50 mm dia. complete as per specification no. FF-VL/BFV
Supply,installation,testing and Commissioning 100mm Flow Switch
Supply,installation,testing and Commissioning White/SS Rosette plate
Supply,installation,testing and Commissioning 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Providing & fixing of approved corrugated SS-304 Braided flexible sprinkler pipe droplet of for 12 kg/ sq. cm. working pressure of length 1.0m & 1.5m length , with 1/2" or 3/4" BSP threaded outlet & 1" BSP threaded inlet with reducer nipple, snap, clamp, T-bar bracket etc. with necessary fitting complete as required. SS-304 Braided flexible sprinkler pipe droplet
Supply,installation,testing and Commissioning of 150mm GI Fire alarm valve ( installation control valve) for 250 PSI operating pressure epoxy coated internally and externally.
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS780 of following sizes as required (Zonal Control Valve)
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 150mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 100mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 75/80 mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 50 mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specificationno. FF-VL/HV
Supply,installation,testing and Commissioning wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) fitted with necessary accessories complete as per specification no. FF-FFA/HV
Supply,installation,testing and Commissioning fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supply,installation,testing and Commissioning stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour
Supply,installation,testing and Commissioning 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supply,installation,testing and Commissioning of cast iron double flange butterfly valve of size 150 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF-VL/BFV
Supply,installation,testing and Commissioning cast iron double flange NRV of size 150 mm dia complete as per specification no. FF-VL/NRV
Supply,installation,testing and Commissioning pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Supply,installation,testing and Commissioning pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 150mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 75/80 mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supply,installation,testing and Commissioning fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supply,installation,testing and Commissioning stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour
Supply,installation,testing and Commissioning of cast iron double flange butterfly valve of size 150 mm dia. complete as per specification no. FF-VL/BFV
Supply,installation,testing and Commissioning cast iron double flange butterfly valve of size 75/80 mm dia. complete as per specification no. FF-VL/BFV
Supply,installation,testing and Commissioning fire brigade header of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/ FBC
Supply,installation,testing and Commissioning fire brigade header (Siamese connection) of 150 mm dia for supplying water to wet riser system complete as per specification no. FF-FFA/SMC
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 250mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 200mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 150mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 100mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 75/80 mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size 50 mm dia with necessary fittings as per Specification no FF PP
Supply,installation,testing and Commissioning G.I. pipe above ground of „C‟ class ERW of size 25 mm dia with necessary fittings complete as per specification no. FF-PP
Supply,installation,testing and Commissioning cast iron double flange sluice valve 200 mm dia. complete as per specification no. FF-VL/SV
Supply,installation,testing and Commissioning of cast iron double flange butterfly valve of size 150 mm dia. complete as per specification no. FF-VL/BFV
Supply,installation,testing and Commissioning of cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF-VL/BFV
Supply,installation,testing and Commissioning cast iron double flange butterfly valve of size 75/80 mm dia. complete as per specification no. FF-VL/BFV
Supply,installation,testing and Commissioning cast iron double flange butterfly valve of size 65 mm dia. complete as per specification no. FF-VL/BFV
Supply,installation,testing and Commissioning of cast iron double flange butterfly valve of size 50 mm dia. complete as per specification no. FF-VL/BFV
Supply,installation,testing and Commissioning cast iron double flange NRV of size 200mm dia complete as per specification no. FF-VL/NRV
Supply,installation,testing and Commissioning cast iron double flange NRV of size 150 mm dia complete as per specification no. FF-VL/NRV
Supply,installation,testing and Commissioning cast iron double flange NRV of size 100 mm dia complete as per specification no. FF-VL/NRV
Supply,installation,testing and Commissioning cast iron double flange NRV of size 75/80 mm dia complete as per specification no. FF-VL/NRV
Supply,installation,testing and Commissioning 150 mm dia end line strainer for positive suction complete as per specification no. FF-VL/ELS
Supply,installation,testing and Commissioning 200 mm dia end line strainer for positive suction complete as per specification no. FF-VL/ELS
Supply,installation,testing and Commissioning 75/80mm dia end line strainer for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 200 mm dia with necessary fittings complete as per specification no. FF-PP
Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration of 200 mm Dia eliminators suitable for raw water up to 45 deg. C temperature, working pressure 16Kg/cm2 and test pressure 24 Kg/cm2 to provide relief from stresses at pipe flanges. It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge.
Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration of 150 mm Dia eliminators suitable for raw water up to 45 deg. C temperature, working pressure 16Kg/cm2 and test pressure 24 Kg/cm2 to provide relief from stresses at pipe flanges. It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge.
Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration of 100 mm Dia eliminators suitable for raw water up to 45 deg. C temperature, working pressure 16Kg/cm2 and test pressure 24 Kg/cm2 to provide relief from stresses at pipe flanges. It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge.
Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration of 80mm Dia eliminators suitable for raw water up to 45 deg. C temperature, working pressure 16Kg/cm2 and test pressure 24 Kg/cm2 to provide relief from stresses at pipe flanges. It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge.
Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration of 65mm Dia eliminators suitable for raw water up to 45 deg. C temperature, working pressure 16Kg/cm2 and test pressure 24 Kg/cm2 to provide relief from stresses at pipe flanges. It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge.
Supply,installation,testing and Commissioning of GI pipe above Ground of ' C' class ERW of size100mm dia with necessary fittings as per water Flow Meter
Supply,installation,testing and Commissioning air vessel of 300 mm dia 1.5m in height M.S. tank installed inside pump house / on terrace complete as per specification no. FF-FFA/ACT
Supply,installation,testing and Commissioning pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Supply,installation,testing and Commissioning pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of fire service main multi stage pump, of 2800 LPM at 105 m Head centrifugal type, 120 HP, (90 kW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/MSC (Hydrant Pump)
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of fire service main multi stage pump, of 2800 LPM at 105 m Head centrifugal type, 120 HP, (90 kW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/MSC (Sprinkler Pump)
FIRE PUMPS - DIESEL ENGINE DRIVEN Supply, installation, testing and commissioning of Diesel Engine driven fire pump suitable for automatic operation comprising of the following : Horizontally mounted end suction single/multi stage, single/multi outlet centrifugal pump, suitable for operation on 415 volts ± 10%, 3 phase, 50 HZ A.C supply, complete with flexible coupling and coupling guard as required. Fire pump having C.I. body, bronze impeller and S.S. Shaft with mechanical seal, capable for delivering 2800 LPM of water at 105 mts. head to ensure a minimum pressure of 3.5.kg/cm2 at the terrace/farthest hydrant. The pump should meet the condition of Local fire Authority/NBC). Water/Air Cooled Diesel engine (4/6 CYLINDER ENGINE) of speed 1800 RPM for the above pump with automatic starting mechanism (AMF autostart panel complete with necessary relays like no volt relay, over voltage and low voltage relays, contactors, timer, pressure switch etc. as required for the auto start of the diesel engine in case of power failure complete with all accessories, wiring & cabling) and other accessories including fuel tank (fabricated from 3mm MS sheet painting with two coats of synthetic enamel paint over a coat of primer)
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of jockey pump of 240 LPM at 105 m head 20 HP (15 kW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/JP (Hydrant Pump)
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of jockey pump of 240 LPM at 105 m head 20 HP (15 kW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/JP (Sprinkler Pump)
Supplying & erecting cast iron double flange butterfly valve of size 150 mm dia. complete as per specification no. FF-VL/BFV.
Supplying and erecting D.C.P. type fire extinguisher 6 kg capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985/ IS 15683 and complete erected with necessary clamps made from 50x6 mm M.S. flat with nuts & bolts grouted in wall complete
Supplying and erecting D.C.P. type fire extinguisher 9kg capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985/ IS 15683 and complete erected with necessary clamps made from 50x6 mm M.S. flat with nuts & bolts grouted in wall complete
Supplying, installing, testing and commissioning of Gun metal/Aluminum alloy/Stainless steel curtain type nozzle head with deflector with screw end, CFO/IS approved with approved chrome finish including joints to steel pipe work. The water curtain Nozzle shall be UL/FM approved Water Curtain Nozzle (K factor - 72) 15mm dia Page 76
Supplying, installing, testing and commissioning of 180° pattern type Cast iron Deluge Valve assembly 150mm with CFO/UL approved consisting of all related required controls ,trim assembly necessary by-pass piping , Orifice plate, isolation valves,solenoid valve, Local Releasing panel, control cable between releasing panel and DV to make the system functional.. Deluge valve shall be externally reset table by hydraulic means and mechanical. Inlet and outlet connections of deluge valve will be pipe thread (female) / flanged connection. Solenoid valve and all the accessories and controls required to make the assembly complete. Complete Should have pressure operated relief valve-venting device on the priming line to ensure that the deluge valve will not prematurely reset. Deluge valve shall have a working pressure up to 12-18 Bar. Deluge valve shall have orifce plate, as per the contractor's approved calculations. Flange Type - To suit the piping system Valve trim - Vertical Trim type - Electrical Approval - UL/FM APPROVED The trim assembly shall be complete with Isolation valves,Diapharm Supply valve, Manual control station , Automatic Shut-off valve, Automatic drain valve, pressure switch, Water Motor gong ,Releasing panel,
Supplying, Erecting, Testing & Commisisoning of FIRE FIGHTING PANEL with I/C 800 A 4P 50kA EDO ACB Microprossed Based - 1 No O/G 200 A 4P 50kA MCCB Microprossed Based - 9 Nos 100 HP STAR / DELTA STARTER - 9 Nos All incomer shall have SPD, RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital voltmeter, Digital Ammeter, Digital MFM compatible for BMS control, CT for metering, control wiring. All outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital voltmeter, Digital Ammeter, CT for metering, control wiring. Panel shall be operated during Fire mode and shall be Synchronized with Fire alarm panel. The panel shall be manufactured from CPR I approve panel manufacturer. Panel with 14/16 swg 7 tank process epoxy powder coated. Cable Entry / exit from bottom / top as per site requirement Copper/Aluminium busbar size be suitable for carrying current of 1.5 higher rating of breaker. Copper current density 1.6 ampere / sq. M & Aluminium current density 1 ampere / sq. M. Each phase duly covered with red yellow blue And black colour heat shrinkable sleeves. The panel shall be double door and indoor type. The panel shall be indoor type and floor mounted. Name tag plate shall be provided as per the requirement. Red Colour powder coated. The schematic drawing for the above panel shall be got approved from client / appointed electrical consultant before manufacturing the panel. The panel shall be inspected and tested and manufacturing place before dispatch at site from client/electrical consultant. All feederes with r y b phase indicator lamp and multifunction metres compatible for BMS control. The apfc panel shall be complete with all required protection accessories wiring extra. The form of saparation should be 4B type.
Supplying, erecting & terminating XLPE armoured cable 3½ core 95 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification No. CB-LT/AL
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete.
SITC of Indoor Escalator with following specifications: STEP WIDTH: 1000 mm HORIZONTAL/FLAT STEPS: 2/2 INCLINATION: 35 deg VERTICAL RISES: 3600mm Operational Speed: 0.5 m/s TRASPORTATION CAPACITY: 6000 P/H MAIN POWER SUPPLY: 3 × 415 V (-10% to +6%) at 50 Hz (±2 Hz), 240 V lighting supply BALUSTRADE TYPE: 10mm thick Tamperred Glass (Slim Type) BALUSTRADE HEIGHT: 1000mm HANDRAIL MATERIAL: Synthetic Rubber with Nylon Linning (Black) DECKING [INNER & OUTER]: Stainless steel SKIRTING: Sheet steel with black anti-friction coating ACCESS/LANDING COVER: Ribbed aluminum with natural color STEP TYPE: One piece die cast Aluminum STEP COLOR:Silver STEP DEMARCATION: Yellow painted lines at three sides COMB SEGMENT: Aluminum with plastic inlay LOAD DEFLECTION: Max 1:750 TRUSS STRUCTURE: Hollow profiles, L-profiles and U-profiles MOTOR: 3-phase, 6-pole induction motor and F insulation with IP55 protection Drive: VVVF GEAR BOX: Worm gear HANDRAIL DRIVE: Friction drive wheel via pressure rollers BRAKE : Operational brake DRIVE CHAIN: Duplex drive chain STEP CHAIN: Precision roller type, with heat-treated links CONTROLLER TYPE: Microprocessor based PCB CONTROLLER CABINET: Steel Cabinet with IP 54 protection OPERATION MODE: Automatic start / stop Other Features: Comb plate impact devices, Handrail inlet switches, Step sag switches, Broken step chain switches (chain tension control switches, lower), Motor speed monitor (overspeed, under-speed, unintentional reverse, and braking deceleration), Motor thermal protection, Mains supply isolator, Emergency stop buttons beside key switches, Stop switches within upper and lower maintenance pits, Handrail speed and breakage monitor, Access cover safety switches, Mechanical step band lock, Missing step detector, Brake lift monitoring switch, Broken drive chain device, Skirt switches, Anti climb barrier, Step reverse fences, Handrail anti-static roller, Step anti-static brush, Phase failure Indicator, Monitoring contacts, Buzzer alarm, Fire alarm relay, Wrong direction warning.Traffic light, Comb light.
Supply, installation, testing and commissioning of Water Cooled Screw 590 TR at AHRI Conditions. with motor, machine mounted / free standing VFD in NEMA1 enclosure (VFD should be provided & integrated with Chiller by the Chiller OEM) , water cooled condenser, flow switch at chiller and condenser, vibration isolators, integral refrigerant piping and wiring, BMS interface unit (Modbus/BacNET), grooved couplings for condenser and cooler water in/out connections, complete charge of refrigerant and oil, accessories as required and called for, automatic and safety controls mounted in central micro-processor based control panel and all mounted on a steel frame complete as per specifications. Motor shall be suitable for 415±10% 50 cycles. 3 phase AC supply. Refrigerant used shall be Ozone friendly HFC-134a as detailed in specifications. One chiller shall be factory tested at design conditions at 100%, 75%, 50% and 25% load as per AHRI standardChiller Operational Parameters shall be as under -Chiller Water In Temp of 12 deg C Chilled Water Out Temp of 7 deg C, Foul facto of 0.00025 FPS. -Condensor Water IN temp. of 32 deg C, cond water out temp. of 37 deg C, Fouling Factor of 0.001 FPS. IkW/TR at 100% load at tender conditions < 0.66@ Design Conditions. Max. Pressure drop on Evaportor and condensor side 10 mtr (0.98 bars). Chilling machine COP (at AHRI conditions) shall be min 6.Chilling machine COP (at AHRI conditions) shall be min 6 (without applying Kadj factor)
Supplying, erecting, testing, and commissioning of digital active 150 A harmonic filter cum power conditioner, with digital closed loop active filter with source current sensing, 32 bit digital signal processing with less than 1 millisecond response time, high speed IGBTs in power circuit with necessary CTs to be mounted on existing cable/bus and shunted to supply along with digital display showing voltage, current, frequency, kW, kVA, kVAr , PF, VTHD, ITHD and waveform with alarm for 3 phase 4 wire system as per specification No. CP-ED/DAHF
Supply, installation, testing and commissioning of vertical Inline Pump mounted on a common base with electric motor for re-circulation of water for the central air conditioning system. The pumps shall be flexible coupled protected by OSHA complaint coupling guard, with CI casing, SS (CF8) /bronze impeller, high strength steel shaft (prefarably SS 304) and MS fabricated base plate .The pump motor shall be suitable for 415± 10% volts, 50 cycles, 3 phase AC power supply of (IE3) efficiency class. Motor shall be squirrel cage, Class F insulation, 1500 RPM (Max.) Pump, base, coupling and motor shall be factory assembled. The capacity of motor shall be at least 10% in excess of BHP requirement of pump. The internal components of pumps including mechanical seal shall be suitable to sustain a temperature of 122 degree Fahrenheit. Minimum efficiency of pump shall be as mentioned below including pump foundation, suitable support/Mounting Arrangement including making connection of inlet & outlet with fittings including nut, bolts, packing etc.) with plaster, Anti vibration arrangement of cushy foot mountings is deemed to be included in this item cost. Suction guide to be provided by pump manufacturar for unit responsability. Pump curves & loss calculations shall be furnished during approval from competant authority. Pumps shall be BMS compatible.Pump rating shall be PN 16 preferably. Water flow rate: 1800USGPM, Static head: 20 mtr, Impeller: Bronze, Efficiency: NLT 80%
Supply, installation, testing and commissioning of Vertical Inline Pump mounted on a common base with electric motor for re-circulation of water for the central air conditioning system. The pumps shall be flexible coupled protected by OSHA complaint coupling guard, with CI casing, SS (CF8)/bronze impeller, high strength steel shaft (prefarably SS 304) and MS fabricated base plate .The pump motor shall be suitable for 415± 10% volts, 50 cycles, 3 phase AC power supply of (IE3) efficiency class. Motor shall be squirrel cage, Class F insulation, 1500 RPM (Max.). Pump, base, coupling and motor shall be factory assembled. adjustable The capacity of motor shall be at least 10% in excess of BHP requirement of pump. The internal components of pumps including mechanical seal shall be suitable to sustain a temperature of 122 degree Fahrenheit. Minimum efficiency of pump shall be as mentioned below. This includes pump foundation, suitable support/Mounting Arrangement including making connection of inlet & outlet with fittings including nut, bolts, packing etc.) with plaster. Pumps Shall be BMS & VFD compatible. Suction guide to be provided by pump manufacturar for unit responsability. Contractor to submit proposed pump model with duty curve. Pump rating shall be PN 16. The chilled water pumps shall also include the cost of thermal insulation. Secondary chilled water pumps shall be suitable for operation on variable frequency drives & conforming to the specifications of variable speed pumping system. The capacity of motor shall be at least 10% in excess of BHP requirement of pump wiht following specifications: Water flow rate: 2800 USGPM, Static head: 35 mtr, Impeller: Bronze, Efficiency: NLT 80%
Supply, installation, testing and commissioning of VSPS (variable Speed Pumping System) consisting of 03 No. 75 HP variable frequency drive (VFD) having IP 54/IP-55 enclosure with heat sink suitably interfaced with other system components, hand / auto macro designed for pumping application, 01 No. dedicated microprocessor based pump logic controller, parallel pumping software duly downloaded, 03 No. Differential Pressure Sensor / Transmitters (or as required to meet the functional requirements), interfacing amongst all components and compatibility of I/O signals etc. complete with other accessories as required. It should be BMS compatible complete with other accessories as required. It should be complete as per manufacturer's Specifications & as directed by Engineer-in-charge. For 5 No. of 75 H.P Secondary Chilled Water Pumps (4W+1 S)
Supplying, installing, testing and commissioning of PRESSURISED COLD WATER EXPANSION TANK WITH AIR SEPARATER with S.S braided pipe flexible connector suitable for total volume of water in cold water circuits along with necessary accessories such as centrifugal air separator, pumps etc. in order to keep cold water system under (+) pressure and to prevent entrapment of pressure and to prevent entrapment of air in the system. The tank shall be precharged steel expansion tank with replaceable heavy duty butyl rubber bladder. The tank shall have 50 MM system connection and 20 mm drain and charging valve connection to facilitate the on site charging of the tank to meet system requirement. The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank and air separator must be constructed in accordance with section VIII of the ASME Boiler and pressure vessel (Unfired)code and stamped 125 PSI working pressure. The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures and safety fixtures required for proper functioning of the complete hydronic system. The expansion tank shall be supplied along with pressurization unit. The pressurization unit shall consist of two No.(1 working+1 stand-by) high pressure pumps of suitable pressure rating mounted on M.S. frame, complete with interconnecting piping, isolation valves, NRV, Y-strainer, Pressure gauge, pressure transmitter, auto-logic panel(IP 55) with dry-run protection, electrical MCB and interconnecting wiring. The unit shall be housed in powder-painted canopy suitable for external installation, if required.The capacity of tank shall be 4000 GPM approx. (for chilled water system).
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning of Decorative High Wall Mounted type Chilled Water based High Wall type Fan Coil Units, EUROVENT certified, with energy efficient 3 speed motor, ABS plastic decorative casing, Low noise fan-motor combination, Filter with 70% dt 20 micron, Hydrophilic Al fins and Copper Chilled Water 2 row, multi-step C shaped Cooling Coil section with minimum 2 Row and minimum 13 FPI Chilled Water Cooling Coil, an in-built 2 way On/ Off control valve of minimum PN16 rating duly connected and wired, with combination of pair of brass ball valve with "Y" strainer set fixed outside FCU, Cu piping with required couplings to fit CHW field In / Out piping; All piping are to be insulated with closed cell elastomeric rubber insulation. Unit shall be equipped with self-diagnostic function, temperature display and supplied with Digital Display type cordless remote with 3 speed fan switch & Temp Edit facility & Digital Temp Display, supplied with relevant power supply cable from nearest point to FCU as required. Units should be compatible with Modbus and extra items for BMS. 2.60 kW / 425 CMH
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning of Decorative High Wall Mounted type Chilled Water based High Wall type Fan Coil Units, EUROVENT certified, with energy efficient 3 speed motor, ABS plastic decorative casing, Low noise fan-motor combination, Filter with 70% dt 20 micron, Hydrophilic Al fins and Copper Chilled Water 2 row, multi-step C shaped Cooling Coil section with minimum 2 Row and minimum 13 FPI Chilled Water Cooling Coil, an in-built 2 way On/ Off control valve of minimum PN16 rating duly connected and wired, with combination of pair of brass ball valve with "Y" strainer set fixed outside FCU, Cu piping with required couplings to fit CHW field In / Out piping; All piping are to be insulated with closed cell elastomeric rubber insulation. Unit shall be equipped with self-diagnostic function, temperature display and supplied with Digital Display type cordless remote with 3 speed fan switch & Temp Edit facility & Digital Temp Display, supplied with relevant power supply cable from nearest point to FCU as required. Units should be compatible with Modbus and extra items for BMS. 4.25 kW/ 850 CMH
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Eurovent certified Ceiling suspended Chilled Water based 4 way flow Cassette type Fan Coil Units 2.0 TR / 800 CFM with Single Phase 3 speed AC motor/ Filter section with prefilters 90% dt 20 micron / Coil section with minimum 2 Row and minimum 13 FPI Chilled Water Cooling Coil / factory fitted pair of brass ball valve with "Y" strainer set/ Insulated Drain Pan / supplied with factory fitted matching size 2 way on/off valve of minimum PN16 rating fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping; Unit shall be Modbus compatible (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with cable from Controller to FCU as required. Relevant additional items if any shall be included in the price scope. Units shall be self-diagnostic type with relevant safety interlocks.
Supply, Installation, testing and commissioning of Eurovent certified factory fabricated double skin type Air Handling Units (BMS compatible) for Operation Theatres as per specifications given below:- AHU Construction:- It shall be made out of 0.8 mm pre -coated Galvanised steel sheet outside & 0.8 mm plain steel sheet inside with 40 mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 40 kg/Cum between them. Drain pan (made out of 1.2 mm stainless steel (SS Grade 304) sheet insulated with 19 mm think closed cell insulation nitrile rubber with thermal brake profile. AHUs Inner skin of panels & all parts which comes with air contact shall be minimum 22 G anodized aluminum. Necessary foundation required & Inertia Bases shall be provided & cost for the same shall be included in this item. (Refer Schedule B in DTP for Detailed item description) F/MOT ,3500 CFM,30 TR, 65 mm ESP,Fan motor of 3.0 HP SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
Supply, Installation, testing and commissioning of Eurovent certified factory fabricated double skin type Air Handling Units (BMS compatible) for Operation Theatres as per specifications given below:- AHU Construction:- It shall be made out of 0.8 mm pre -coated Galvanised steel sheet outside & 0.8 mm plain steel sheet inside with 40 mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 40 kg/Cum between them. Drain pan (made out of 1.2 mm stainless steel (SS Grade 304) sheet insulated with 19 mm think closed cell insulation nitrile rubber with thermal brake profile. AHUs Inner skin of panels & all parts which comes with air contact shall be minimum 22 G anodized aluminum. Necessary foundation required & Inertia Bases shall be provided & cost for the same shall be included in this item. (Refer Schedule B in DTP for Detailed item description) F/M OT 1 , 4400CFM, 37TR,65 mm ESP,Fan motor of 5.0 HP SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
Supply, Installation, testing and commissioning of Eurovent certified factory fabricated double skin type Air Handling Units (BMS compatible) for Other critical Areas like ICU, CT/MRI etc. areas as per specifications given below:- AHU Construction:- It shall be made out of 0.8 mm pre -coated Galvanised steel sheet outside & 0.8 mm plain steel sheet inside with 40 mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 40 kg/Cum between them. Drain pan (made out of 1.2 mm stainless steel (SS Grade 304) sheet insulated with 19 mm think closed cell insulation nitrile rubber with thermal brake profile.AHUs Inner skin of panels & all parts which comes with air contact shall be minimum 22 G anodized aluminum. Necessary foundation required & anti vibration pads shall be provided & cost for the same shall be included in this item. F/M AHU-02 ,10000 CFM,25 TR,65 mm ESP,Fan motor of 2.0 HP SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
Supply, Installation, testing and commissioning of Eurovent certified factory fabricated double skin type Air Handling Units (BMS compatible) for Other critical Areas like ICU, CT/MRI etc. areas as per specifications given below:- AHU Construction:- It shall be made out of 0.8 mm pre -coated Galvanised steel sheet outside & 0.8 mm plain steel sheet inside with 40 mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 40 kg/Cum between them. Drain pan (made out of 1.2 mm stainless steel (SS Grade 304) sheet insulated with 19 mm think closed cell insulation nitrile rubber with thermal brake profile.AHUs Inner skin of panels & all parts which comes with air contact shall be minimum 22 G anodized aluminum. Necessary foundation required & anti vibration pads shall be provided & cost for the same shall be included in this item. (Refer Schedule B in DTP for Detailed item description) F/M AHU-FF-01, 6000 CFM,14.0 TR, 65 mm ESP ,Fan motor of 5.0 HP SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
Supply, Installation, testing and commissioning of Eurovent certified factory fabricated double skin type Air Handling Units (BMS compatible) for Other critical Areas like ICU, CT/MRI etc. areas as per specifications given below:- AHU Construction:- It shall be made out of 0.8 mm pre -coated Galvanised steel sheet outside & 0.8 mm plain steel sheet inside with 40 mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 40 kg/Cum between them. Drain pan (made out of 1.2 mm stainless steel (SS Grade 304) sheet insulated with 19 mm think closed cell insulation nitrile rubber with thermal brake profile.AHUs Inner skin of panels & all parts which comes with air contact shall be minimum 22 G anodized aluminum. Necessary foundation required & anti vibration pads shall be provided & cost for the same shall be included in this item. (Refer Schedule B in DTP for Detailed item description) F/M AHU-FF-03,18473CFM,44.0 TR, 65 mm ESP ,Fan motor of 5.0 HP SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
Supply, Installation, testing and commissioning of Eurovent certified factory fabricated double skin type Air Handling Units (BMS compatible) for Other critical Areas like ICU, CT/MRI etc. areas as per specifications given below:- AHU Construction:- It shall be made out of 0.8 mm pre -coated Galvanised steel sheet outside & 0.8 mm plain steel sheet inside with 40 mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 40 kg/Cum between them. Drain pan (made out of 1.2 mm stainless steel (SS Grade 304) sheet insulated with 19 mm think closed cell insulation nitrile rubber with thermal brake profile.AHUs Inner skin of panels & all parts which comes with air contact shall be minimum 22 G anodized aluminum. Necessary foundation required & anti vibration pads shall be provided & cost for the same shall be included in this item. (Refer Schedule B in DTP for Detailed item description) CSU AHU-FF-01, 6000 CFM,14.0 TR, 65 mm ESP ,Fan motor of 5.0 HP SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
Supply, Installation, testing and commissioning of Eurovent certified factory fabricated double skin type Air Handling Units (BMS compatible) for Other critical Areas like ICU, CT/MRI etc. areas as per specifications given below:- AHU Construction:- It shall be made out of 0.8 mm pre -coated Galvanised steel sheet outside & 0.8 mm plain steel sheet inside with 40 mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 40 kg/Cum between them. Drain pan (made out of 1.2 mm stainless steel (SS Grade 304) sheet insulated with 19 mm think closed cell insulation nitrile rubber with thermal brake profile.AHUs Inner skin of panels & all parts which comes with air contact shall be minimum 22 G anodized aluminum. Necessary foundation required & anti vibration pads shall be provided & cost for the same shall be included in this item. (Refer Schedule B in DTP for Detailed item description) CSU AHU-FF-01, 2500 CFM,6 TR, 10 mm ESP ,Fan motor of 5.0 HP SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
Supply, Installation, testing and commissioning of Eurovent certified factory fabricated double skin type Air Handling Units (BMS compatible) for Other critical Areas like ICU, CT/MRI etc. areas as per specifications given below:- AHU Construction:- It shall be made out of 0.8 mm pre -coated Galvanised steel sheet outside & 0.8 mm plain steel sheet inside with 40 mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 40 kg/Cum between them. Drain pan (made out of 1.2 mm stainless steel (SS Grade 304) sheet insulated with 19 mm think closed cell insulation nitrile rubber with thermal brake profile.AHUs Inner skin of panels & all parts which comes with air contact shall be minimum 22 G anodized aluminum. Necessary foundation required & anti vibration pads shall be provided & cost for the same shall be included in this item. (Refer Schedule B in DTP for Detailed item description) CSU AHU-FF-01, 3200 CFM,10.0 TR, 15 mm ESP ,Fan motor of 5.0 HP SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
Supplying, installing, testing and commissioning of HEAT RECOVERY UNIT consisitng of HEAT RECOVERY PIPE, with 50mm thick double skin construction with Thermal Break Profile as per specification, each complete with pre-filter section (90% down to 10 microns) with MERV-13, min 8 Row Deep water coil of copper tube & aluminium fins construction and base frame. The coil shall be sized for the actual capacity considering with out heat pipe unit. The unit shall comprise of filter section, heat recovery unit, fresh air inlet / exhaust air outlet, fan section with DIDW fan with motor and drive package. (Refer Schedule B in DTP for Detailed item description) F/M GF-AHU-01,10500 CFM,23TR,50 mm ESP,Fan motor of 7.5 HP SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
Supplying, installing, testing and commissioning of HEAT RECOVERY UNIT consisitng of HEAT RECOVERY PIPE, with 50mm thick double skin construction with Thermal Break Profile as per specification, each complete with pre-filter section (90% down to 10 microns) with MERV-13, min 8 Row Deep water coil of copper tube & aluminium fins construction and base frame. The coil shall be sized for the actual capacity considering with out heat pipe unit. The unit shall comprise of filter section, heat recovery unit, fresh air inlet / exhaust air outlet, fan section with DIDW fan with motor and drive package. (Refer Schedule B in DTP for Detailed item description) F/M GF-AHU-03,2000 CFM,15 TR,50 mm ESP,Fan motor of 7.5 HP SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
Supply, installation, testing & commissioning of VFDs.VFD designed for HVAC applications with built-in PID controller, control panel (keypad & display) , IP-65 enclosure (for outdoor applications) & IP-20 enclosure (for indoor applications) for use on AHU fans. The display should be in alpha-numeric characters and programming facility should be in user-friendly HVAC terminology. VFD’s shall have built-in harmonic filters with THDI less than 5%. No. VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption. No. VFD shall be installed in a dedicated external/internal enclosure and the inter connecting wires between driver and MCC shall be included. Necessary transformer, power adapters, sensors, relay etc. as required for satisfactory operation shall be in the scope of VFD supplier. It should be BMS Compatible. 10.0 HP/ 7.5 KW
Supply, installation, testing & commissioning of VFDs.VFD designed for HVAC applications with built-in PID controller, control panel (keypad & display) , IP-65 enclosure (for outdoor applications) & IP-20 enclosure (for indoor applications) for use on AHU fans. The display should be in alpha-numeric characters and programming facility should be in user-friendly HVAC terminology. VFD’s shall have built-in harmonic filters with THDI less than 5%. No. VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption. No. VFD shall be installed in a dedicated external/internal enclosure and the inter connecting wires between driver and MCC shall be included. Necessary transformer, power adapters, sensors, relay etc. as required for satisfactory operation shall be in the scope of VFD supplier. It should be BMS Compatible. 7.5 HP/ 5.6 KW
Supply, installation, testing & commissioning of VFDs.VFD designed for HVAC applications with built-in PID controller, control panel (keypad & display) , IP-65 enclosure (for outdoor applications) & IP-20 enclosure (for indoor applications) for use on AHU fans. The display should be in alpha-numeric characters and programming facility should be in user-friendly HVAC terminology. VFD’s shall have built-in harmonic filters with THDI less than 5%. No. VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption. No. VFD shall be installed in a dedicated external/internal enclosure and the inter connecting wires between driver and MCC shall be included. Necessary transformer, power adapters, sensors, relay etc. as required for satisfactory operation shall be in the scope of VFD supplier. It should be BMS Compatible. 5.0 HP/ 3.73 KW
Supply, installation, testing & commissioning of VFDs.VFD designed for HVAC applications with built-in PID controller, control panel (keypad & display) , IP-65 enclosure (for outdoor applications) & IP-20 enclosure (for indoor applications) for use on AHU fans. The display should be in alpha-numeric characters and programming facility should be in user-friendly HVAC terminology. VFD’s shall have built-in harmonic filters with THDI less than 5%. No. VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption. No. VFD shall be installed in a dedicated external/internal enclosure and the inter connecting wires between driver and MCC shall be included. Necessary transformer, power adapters, sensors, relay etc. as required for satisfactory operation shall be in the scope of VFD supplier. It should be BMS Compatible. 3.0 HP/ 2.2 KW and below rating
Supply, installation, testing and commissioning of latest generation digital display type BMS compatible thermostat / humidistat with controller for cool / heat application suitable for two/four pipe system & humidistat suitable for working with humidifier and hot water coil control valves for various air handling Units. The thermostat shall have provision of setting of space temperature and display of the same. The humidistat shall have provision of setting space RH and display of the same. The quoted price of thermostat / humidistat shall include the cost of 20mm MS conduits, control cabling, MS Box etc. as required. The cost quoted shall be excluding the control valves and humidifier. It shall include all accessories ,mountings, wiring between thermostat & unit, terminations etc.(BMS Compatibility to be provided).
Supply, Installation, testing and commissioning of Two way , high range ability / Pressure independent dynamic Balancing cum Control valves fitted with motorised,modulating actuators with linear stroke of minimum 15 mm, in chilled water lines at No. air handling unit. The actuator shall have shut off capability of minimum 4 bar rating. The actuator shall be controlled by BMS & should accept a signal of 4-20mA/2-10 VDC.The valves shall be suitable for following flow rate and confirming to specifications. 40 mm Dia
Supply, Installation, testing and commissioning of Two way , high range ability / Pressure independent dynamic Balancing cum Control valves fitted with motorised,modulating actuators with linear stroke of minimum 15 mm, in chilled water lines at No. air handling unit. The actuator shall have shut off capability of minimum 4 bar rating. The actuator shall be controlled by BMS & should accept a signal of 4-20mA/2-10 VDC.The valves shall be suitable for following flow rate and confirming to specifications. 50 mm Dia
Supply, Installation, testing and commissioning of Two way , high range ability / Pressure independent dynamic Balancing cum Control valves fitted with motorised,modulating actuators with linear stroke of minimum 15 mm, in chilled water lines at No. air handling unit. The actuator shall have shut off capability of minimum 4 bar rating. The actuator shall be controlled by BMS & should accept a signal of 4-20mA/2-10 VDC.The valves shall be suitable for following flow rate and confirming to specifications. 65 mm Dia
Supply, Installation, testing and commissioning of Two way , high range ability / Pressure independent dynamic Balancing cum Control valves fitted with motorised,modulating actuators with linear stroke of minimum 15 mm, in chilled water lines at No. air handling unit. The actuator shall have shut off capability of minimum 4 bar rating. The actuator shall be controlled by BMS & should accept a signal of 4-20mA/2-10 VDC.The valves shall be suitable for following flow rate and confirming to specifications. 80 mm Dia
Supply, Installation, testing and commissioning of Two way , high range ability / Pressure independent dynamic Balancing cum Control valves fitted with motorised,modulating actuators with linear stroke of minimum 15 mm, in chilled water lines at No. air handling unit. The actuator shall have shut off capability of minimum 4 bar rating. The actuator shall be controlled by BMS & should accept a signal of 4-20mA/2-10 VDC.The valves shall be suitable for following flow rate and confirming to specifications. 100 mm Dia
Supply installation testing & commissioning of digital electronic controller for AHU with Thermostat & with LCD display capable of accepting 0-10v dc signal from BMS and water water temperature signal from coil inlet and outlet sensors confirming to detailed specification. All other accessories i.e. Temperature sensors-3nos,230V/24VAC power supply-1No.thermowell-1no should be included in this item. 40 mm Dia
Supply installation testing & commissioning of digital electronic controller for AHU with Thermostat & with LCD display capable of accepting 0-10v dc signal from BMS and water water temperature signal from coil inlet and outlet sensors confirming to detailed specification. All other accessories i.e. Temperature sensors-3nos,230V/24VAC power supply-1No.thermowell-1no should be included in this item. 50 mm Dia
Supply installation testing & commissioning of digital electronic controller for AHU with Thermostat & with LCD display capable of accepting 0-10v dc signal from BMS and water water temperature signal from coil inlet and outlet sensors confirming to detailed specification. All other accessories i.e. Temperature sensors-3nos,230V/24VAC power supply-1No.thermowell-1no should be included in this item. 65 mm Dia
Supply installation testing & commissioning of digital electronic controller for AHU with Thermostat & with LCD display capable of accepting 0-10v dc signal from BMS and water water temperature signal from coil inlet and outlet sensors confirming to detailed specification. All other accessories i.e. Temperature sensors-3nos,230V/24VAC power supply-1No.thermowell-1no should be included in this item. 80 mm Dia
Supply installation testing & commissioning of digital electronic controller for AHU with Thermostat & with LCD display capable of accepting 0-10v dc signal from BMS and water water temperature signal from coil inlet and outlet sensors confirming to detailed specification. All other accessories i.e. Temperature sensors-3nos,230V/24VAC power supply-1No.thermowell-1no should be included in this item. 100 mm Dia
Supply, installation, testing and commissioning of duct mounted air purification system/ cell based on Photohydroionization cell with the capability to produce friendly oxidizers like Ionized Hydro Peroxides, Super Oxide Ions, Hydroxides Ions with quad metalic coating (Rohdium, silver, copper and titanimum) and duly enclosed by a poly casing tube that should prevent glass or mercury leakage into the conditioned/ served space. The honeycomb matrix shall not be accepted. The units should be designed after undertaking a load factor calculation for No. specific area where the equipment is to be installed. The load shall clearly state the number of units required vis-à-vis the wattage of the units for submital. The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall conform to UL 1598 CAN/CSA C222 EN60335-1, EN60335-2-65, EU standards, certifications shall be submitted along with the technical submital. OT 3500 CFM
Supply, installation, testing and commissioning of duct mounted air purification system/ cell based on Photohydroionization cell with the capability to produce friendly oxidizers like Ionized Hydro Peroxides, Super Oxide Ions, Hydroxides Ions with quad metalic coating (Rohdium, silver, copper and titanimum) and duly enclosed by a poly casing tube that should prevent glass or mercury leakage into the conditioned/ served space. The honeycomb matrix shall not be accepted. The units should be designed after undertaking a load factor calculation for No. specific area where the equipment is to be installed. The load shall clearly state the number of units required vis-à-vis the wattage of the units for submital. The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall conform to UL 1598 CAN/CSA C222 EN60335-1, EN60335-2-65, EU standards, certifications shall be submitted along with the technical submital. OT 1 4400 CFM
Supply, installation, testing and commissioning of the UVGI unit to be fitted downstream (supply air side) portion of Chilled Water coil (for Cooling Coil Treatment & to Improve Indoor Air Quality ) with Reflector, lamp status display, audio-visual lamp failure alarm , lamp lifetime counter, lamp replacement reminder & SS stand.UVGI System shall be designed with scientifically developed UV sizing software in reference with CFD analysis & generate a report to prove the UV delivery of designed intensity.UVGI system for disinfection shall utilize high output UV lamp. The parabolic reflector shall be of semi circle Shape to utilize 100% of UV & it MOC will be Anodized Aluminum. The electrical control system should utilize high frequency electronic ballasts and provide efficiency of more then 90%. System shall have a Dry Contacts or A 4-20 mA output shall also be provided for BMS compatibility. Control Power panel with necessary wiring & cabling to UVGI system upto 15 Mtr.length shall be inclusive in the cost.The UVGI System shall have ETL certification. UVGI system shall be provided for following AHUS for Air capacities as mentioned below respectively. F/MOT ,3500 CFM,30 TR, 65 mm ESP,Fan motor of 3.0 HP SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
Supply, installation, testing and commissioning of the UVGI unit to be fitted downstream (supply air side) portion of Chilled Water coil (for Cooling Coil Treatment & to Improve Indoor Air Quality ) with Reflector, lamp status display, audio-visual lamp failure alarm , lamp lifetime counter, lamp replacement reminder & SS stand.UVGI System shall be designed with scientifically developed UV sizing software in reference with CFD analysis & generate a report to prove the UV delivery of designed intensity.UVGI system for disinfection shall utilize high output UV lamp. The parabolic reflector shall be of semi circle Shape to utilize 100% of UV & it MOC will be Anodized Aluminum. The electrical control system should utilize high frequency electronic ballasts and provide efficiency of more then 90%. System shall have a Dry Contacts or A 4-20 mA output shall also be provided for BMS compatibility. Control Power panel with necessary wiring & cabling to UVGI system upto 15 Mtr.length shall be inclusive in the cost.The UVGI System shall have ETL certification. UVGI system shall be provided for following AHUS for Air capacities as mentioned below respectively. F/M OT 1 , 4400CFM, 37TR,65 mm ESP,Fan motor of 5.0 HP SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
Supply, installation, testing and commissioning of the UVGI unit to be fitted downstream (supply air side) portion of Chilled Water coil (for Cooling Coil Treatment & to Improve Indoor Air Quality ) with Reflector, lamp status display, audio-visual lamp failure alarm , lamp lifetime counter, lamp replacement reminder & SS stand.UVGI System shall be designed with scientifically developed UV sizing software in reference with CFD analysis & generate a report to prove the UV delivery of designed intensity.UVGI system for disinfection shall utilize high output UV lamp. The parabolic reflector shall be of semi circle Shape to utilize 100% of UV & it MOC will be Anodized Aluminum. The electrical control system should utilize high frequency electronic ballasts and provide efficiency of more then 90%. System shall have a Dry Contacts or A 4-20 mA output shall also be provided for BMS compatibility. Control Power panel with necessary wiring & cabling to UVGI system upto 15 Mtr.length shall be inclusive in the cost.The UVGI System shall have ETL certification. UVGI system shall be provided for following AHUS for Air capacities as mentioned below respectively. F/M AHU-02 ,10000 CFM,25 TR,65 mm ESP,Fan motor of 2.0 HP SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
Supply, installation, testing and commissioning of the UVGI unit to be fitted downstream (supply air side) portion of Chilled Water coil (for Cooling Coil Treatment & to Improve Indoor Air Quality ) with Reflector, lamp status display, audio-visual lamp failure alarm , lamp lifetime counter, lamp replacement reminder & SS stand.UVGI System shall be designed with scientifically developed UV sizing software in reference with CFD analysis & generate a report to prove the UV delivery of designed intensity.UVGI system for disinfection shall utilize high output UV lamp. The parabolic reflector shall be of semi circle Shape to utilize 100% of UV & it MOC will be Anodized Aluminum. The electrical control system should utilize high frequency electronic ballasts and provide efficiency of more then 90%. System shall have a Dry Contacts or A 4-20 mA output shall also be provided for BMS compatibility. Control Power panel with necessary wiring & cabling to UVGI system upto 15 Mtr.length shall be inclusive in the cost.The UVGI System shall have ETL certification. UVGI system shall be provided for following AHUS for Air capacities as mentioned below respectively. F/M AHU-FF-01, 6000 CFM,14.0 TR, 65 mm ESP ,Fan motor of 5.0 HP SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
Supply, installation, testing and commissioning of the UVGI unit to be fitted downstream (supply air side) portion of Chilled Water coil (for Cooling Coil Treatment & to Improve Indoor Air Quality ) with Reflector, lamp status display, audio-visual lamp failure alarm , lamp lifetime counter, lamp replacement reminder & SS stand.UVGI System shall be designed with scientifically developed UV sizing software in reference with CFD analysis & generate a report to prove the UV delivery of designed intensity.UVGI system for disinfection shall utilize high output UV lamp. The parabolic reflector shall be of semi circle Shape to utilize 100% of UV & it MOC will be Anodized Aluminum. The electrical control system should utilize high frequency electronic ballasts and provide efficiency of more then 90%. System shall have a Dry Contacts or A 4-20 mA output shall also be provided for BMS compatibility. Control Power panel with necessary wiring & cabling to UVGI system upto 15 Mtr.length shall be inclusive in the cost.The UVGI System shall have ETL certification. UVGI system shall be provided for following AHUS for Air capacities as mentioned below respectively. CSU AHU-FF-01, 2500 CFM,6 TR, 10 mm ESP ,Fan motor of 5.0 HP SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
Supply, installation, testing and commissioning of the UVGI unit to be fitted downstream (supply air side) portion of Chilled Water coil (for Cooling Coil Treatment & to Improve Indoor Air Quality ) with Reflector, lamp status display, audio-visual lamp failure alarm , lamp lifetime counter, lamp replacement reminder & SS stand.UVGI System shall be designed with scientifically developed UV sizing software in reference with CFD analysis & generate a report to prove the UV delivery of designed intensity.UVGI system for disinfection shall utilize high output UV lamp. The parabolic reflector shall be of semi circle Shape to utilize 100% of UV & it MOC will be Anodized Aluminum. The electrical control system should utilize high frequency electronic ballasts and provide efficiency of more then 90%. System shall have a Dry Contacts or A 4-20 mA output shall also be provided for BMS compatibility. Control Power panel with necessary wiring & cabling to UVGI system upto 15 Mtr.length shall be inclusive in the cost.The UVGI System shall have ETL certification. UVGI system shall be provided for following AHUS for Air capacities as mentioned below respectively. F/M AHU-FF-03,18473CFM,44.0 TR, 65 mm ESP ,Fan motor of 5.0 HP SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
Supply, installation, testing & commisioning of magnehelic gauges across OT rooms & Critical areas AHU Filters for differential pressure. This includes SS box to mount these units & neessary tubing & other accessories to get these units functioning (-6 to +6 mm of WG). It should be complete in all respect.
Supplying, installing, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity having ISEER minimum 4.50 suitable to operate on250V, 50 cycles, A.C. supply having 1 no of air handling unit hiwall / floor mounting type complete with refrigerant R410 A/R32 and copper condensor at position. specification no.APAC/ SAC
Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 16 mm complete.
Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 22 mm complete.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for over coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater system.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for over coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 19 mm for solar water heater system.
Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supply, installation, testing and commissioning of FRP induced draft cooling tower with FRP water basin, PVC fills with integral louvers and drift eliminators complete with hot water basin either fitted with spray nozzles or having self rotating sprinklers, statically & dynamically balanced axial flow, gear/direct driven fans with TEFC induction motor of class F insulation, efficiency class EFF-1 suitable for operation on 415 + 10% volts, 50 Hz. AC supply; suction screen, make up-quick fill arrangement, overflow and drain connections with all necessary valves & foot valves, suitable inspection ladder, access arrangement for cooling tower interior, steel /masonary supporting structure with proper design, anti-vibration mountings, suitable civil foundation as per manufacturer's standard with foundation nuts, bolts, painting etc. complete as required with RCC Foundation and as per specification with the following: VFD Driven Cooling Tower(CTI APRROVED), Capacity : 1000 TR x 4 Nos. (3 working & 1 standby), Wet bulb temp: 29.0deg C, Entering water temp : 36.00 deg C , Leaving water temp : 32.00 deg C,Each Tower Capacity : 1000 TR , Flow rate /Cell : 3300 GPM
Supply, installation, testing and commissioning of 4 [3w+1s] numbers End suction back pull out water circulation pump in cast iron body & Bronze impeller, mechanical seals,complete driven with TEFC squirrel cage induction motor with class-F insulation & efficiency class EFF-1 suitable for operation on 415 + 10% volts, 3 phase, 50 Hz., AC supply, base plate, MS fabricated mounting channel frame, all required fittings & accessories including coupling, coupling guard, vibration isolation arrangement by means of rubber type mounting, necessary civil foundation with foundation bolts&nuts complete as required & as per specification with following capacities with RCC foundation: Water flow rate: 3300 USGPM, Static head: 45 mtr , Impeller: Bronze , Efficiency: NLT 80%
Supply, Installation, Testing and Commissioning of On line, Non-Chemical Water Treatment Scale Preventer System : For 2000 TR AC plant 500 TR - 4 NOS (3W+1S) Each condensor line having 300 MM dia.
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) with Grooved couplings - Flexible with Grooving on the pipes ( The valve stations for the AHU & FCU can be one whole welded section ) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 500 mm dia. (32 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) with Grooved couplings - Flexible with Grooving on the pipes ( The valve stations for the AHU & FCU can be one whole welded section ) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 450 mm dia. (32 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) with Grooved couplings - Flexible with Grooving on the pipes ( The valve stations for the AHU & FCU can be one whole welded section ) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 400 mm dia. (32 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) with Grooved couplings - Flexible with Grooving on the pipes ( The valve stations for the AHU & FCU can be one whole welded section ) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 350 mm dia. (32 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) with Grooved couplings - Flexible with Grooving on the pipes ( The valve stations for the AHU & FCU can be one whole welded section ) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 300 mm dia. (32 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) with Grooved couplings - Flexible with Grooving on the pipes ( The valve stations for the AHU & FCU can be one whole welded section ) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 250 mm diameter with insulation of 32mm thk nitrile rubber insulation
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) with Grooved couplings - Flexible with Grooving on the pipes ( The valve stations for the AHU & FCU can be one whole welded section ) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 200 mm diameter with insulation of 32 mm thk nitrile rubber
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) with Grooved couplings - Flexible with Grooving on the pipes ( The valve stations for the AHU & FCU can be one whole welded section ) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 150 mm diameter with insulation of 32mm thk nitrile rubber insulation
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) with Grooved couplings - Flexible with Grooving on the pipes ( The valve stations for the AHU & FCU can be one whole welded section ) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 125 mm diameter with insulation of 32mm thk nitrile rubber insulation
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) with Grooved couplings - Flexible with Grooving on the pipes ( The valve stations for the AHU & FCU can be one whole welded section ) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 100 mm diameter with insulation of 32 mm thk nitrile rubber insulation
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) with Grooved couplings - Flexible with Grooving on the pipes ( The valve stations for the AHU & FCU can be one whole welded section ) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 75 mm diameter with insulation of 19 mm thk nitrile rubber insulation
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) with Grooved couplings - Flexible with Grooving on the pipes ( The valve stations for the AHU & FCU can be one whole welded section ) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 65 mm diameter with insulation of 19 mm thk nitrile rubber insulation
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) with Grooved couplings - Flexible with Grooving on the pipes ( The valve stations for the AHU & FCU can be one whole welded section ) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 50 mm diameter with insulation of 19 mm thk nitrile rubber insulation
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) with Grooved couplings - Flexible with Grooving on the pipes ( The valve stations for the AHU & FCU can be one whole welded section ) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 40 mm diameter with insulation of 19 mm thk nitrile rubber insulation
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) with Grooved couplings - Flexible with Grooving on the pipes ( The valve stations for the AHU & FCU can be one whole welded section ) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 32 mm diameter with insulation of 19 mm thk nitrile rubber insulation
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) with Grooved couplings - Flexible with Grooving on the pipes ( The valve stations for the AHU & FCU can be one whole welded section ) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 25 mm diameter with insulation of 19 mm thk nitrile rubber insulation
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) with Grooved couplings - Flexible with Grooving on the pipes ( The valve stations for the AHU & FCU can be one whole welded section ) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 20 mm dia (19 mm thick insulation)
Supplying, fixing, testing and commissioning of Butterfly Valve(Manual) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot water circulation as specified. 500 mm dia Gear Type
Supplying, fixing, testing and commissioning of Butterfly Valve(Manual) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot water circulation as specified. 450 mm dia Gear Type
Supplying, fixing, testing and commissioning of Butterfly Valve(Manual) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot water circulation as specified. 400 mm dia Gear Type
Supplying, fixing, testing and commissioning of Butterfly Valve(Manual) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot water circulation as specified. 300 mm dia Gear Type
Supplying, fixing, testing and commissioning of Butterfly Valve(Manual) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot water circulation as specified. 250 mm dia Gear Type
Supplying, fixing, testing and commissioning of Butterfly Valve(Manual) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot water circulation as specified. Supplying & erecting cast iron double flange butterfly valve of size 200 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 150 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 75/80 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 65 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 50 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 40 mm dia. complete as per specification no. FF-VL/BFV
Supplying, fixing, testing and commissioning of Pressure independent Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 450 mm dia - Balancing valve
Supplying, fixing, testing and commissioning of Pressure independent Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 400 mm dia
Supplying, fixing, testing and commissioning of Pressure independent Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 350 mm dia
Supplying, fixing, testing and commissioning of Pressure independent Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 300 mm dia
Supplying, fixing, testing and commissioning of Pressure independent Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 250 mm dia
Supplying, fixing, testing and commissioning of Pressure independent Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 200 mm dia
Supplying, fixing, testing and commissioning of Pressure independent Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 125 mm dia
Supplying, fixing, testing and commissioning of Pressure independent Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 100 mm dia
Supplying, fixing, testing and commissioning of Pressure independent Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 80 mm dia
Supplying, fixing, testing and commissioning of Pressure independent Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 65 mm dia
Supplying, fixing, testing and commissioning of Pressure independent Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 50mm dia
Supplying, fixing, testing and commissioning of Pressure independent Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 40 mm dia
Supplying, fixing, testing and commissioning of Pressure independent Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 32 mm dia
Supplying, fixing, testing and commissioning of Non Return Valve with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. It shall be of wafer type preferably with flanged ends. It should be tested for required hydrostatic pressure for shell & seat as per OEM & shall be suitable for maximum working temperature of 80 degree C (approx.).250 mm dia
Supplying, fixing, testing and commissioning of Non Return Valve with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. It shall be of wafer type preferably with flanged ends. It should be tested for required hydrostatic pressure for shell & seat as per OEM & shall be suitable for maximum working temperature of 80 degree C (approx.). 200 mm dia
Supplying, fixing, testing and commissioning of Non Return Valve with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. It shall be of wafer type preferably with flanged ends. It should be tested for required hydrostatic pressure for shell & seat as per OEM & shall be suitable for maximum working temperature of 80 degree C (approx.). 125 mm dia
Y - Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 600 mm Dia Pot strainner
Y - Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 200 mm dia
Y - Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 150 mm dia
Y - Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 100 mm dia
Y - Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 80 mm dia
Y - Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 65 mm dia
Y - Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 50 mm dia
Y - Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 40 mm dia
Y - Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 32 mm dia
Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
SITC of Mercury in glass industrial thermometer in SS-304 casing with 0.5C least count, range 0-50 C. Brass oil filled thermowell of 1/2" size.
Supplying, fixing, testing and commissioning of following sizes Motorized 300 mm Butterfly Valve (UL Approved actuators) with CI Body, SS Disc, O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC ,and upto 20 mA electric signal and providing similar transduced feedback output to control system ,BMS compatable as required
Providing, fixing, testing & commissioning of resilient rubber lined double arch vibration eliminators suitable for raw water up to 45 deg. C temperature to provide relief from stresses at pipe flanges. It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge.(PN 16 rating) 200 mm dia
Providing, fixing, testing & commissioning of resilient rubber lined double arch vibration eliminators suitable for raw water up to 45 deg. C temperature to provide relief from stresses at pipe flanges. It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge.(PN 16 rating) 350 mm dia
Providing, fixing, testing & commissioning of resilient rubber lined double arch vibration eliminators suitable for raw water up to 45 deg. C temperature to provide relief from stresses at pipe flanges. It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge.(PN 16 rating) Providing and fixing 20m dia Auto air vents (Brass MOC).
Providing, fixing, testing & commissioning of resilient rubber lined double arch vibration eliminators suitable for raw water up to 45 deg. C temperature to provide relief from stresses at pipe flanges. It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge.(PN 16 rating) Providing and fixing in position the following 300mm dia water flow switch.
Supplying and erecting ISI mark GI pipe 20 mm dia.„B‟ class at position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting ISI mark GI pipe 25 mm dia.„B‟ class at position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting ISI mark GI pipe 32 mm dia.„B‟ class at position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting ISI mark GI pipe 40 mm dia.„B‟ class at position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for over coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 19mm for solar water heater system
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for over coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22mm for solar water heater system
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for over coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22mm for solar water heater system
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for over coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 42mm for solar water heater system
Supplying and erecting GI sheet 0.6 mm (24 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying and erecting GI sheet 0.8 mm (22 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying and erecting GI sheet 1 mm (20 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying and erecting GI sheet 1.25 mm (18 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supply, fabrication, installation and testing of 20 gauge Aluminium Ducting for OT's in accordance with the approved shop floor drawing complete with all accessories, bends, fittings, specials, chutes, vanes, necessary supports etc. as per specification.
Supply, installation, testing and commissioning of opposed blade aluminium volume control dampers with black mat finish in supply air duct collars,Damper shall be with 16G GSS body and blades shall be with aluminium airfoil construction. complete with neoprene rubber gaskets,nuts, bolts, screws linkages, flanges etc. as per approved shop drawings and specifications.
Supply, fabrication, installation and testing the non-porous flexible connections constructed of fire resistance flexible, double canvas connection with resistoflex material as per the approved shop drawings.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & erecting tile type modular diffuser made from aluminium sheet complete with powder coated matching to the ceiling shade for provided suuply and return air.
Supplying, fixing testing commissioning of supply air diffusers (Flat face type) of powder coated & made from extruded aluminium section with aluminium volume control dampers with anti smudge ring.All extruded aluminium diffusers shall be provided with removable central core and concealed key operation for volume control damper.Complete as required.
Supplying, fixing testing commissioning of return air diffusers (Flat face type) of powder coated & made from extruded aluminium section without aluminium volume control dampers with anti smudge ring.All extruded aluminium diffusers shall be provided with removable central core..Complete as required.
Supply, installation, testing and balancing of Powder Coated AluminiumRisers for return air with SS grilles & SS antirust screws ,washers , gasket joints complete with Hit & Miss volume control damper as per specifications and approved drawings.
Supplying, installation, testing and commissioning of Motorized Smoke & fire dampers, the blades and frame shall be min. 1.6 mm thick GI sheet and factory fitted in a sleeve made out of 1.6 mm thick GS Sheet of min. 400 mm long, with logic Control Panel & required size of Control cabling from control panel to dampers to evacuation fans and roof top units & fire panel to control panel. The damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. (Refer DTP for Detailed ITem Description)
Supplying and fixing of actuator & Control Panel. The actuator should be interlinked with Control panel. Cost should include necessary control wire (minimum 1.5 sqmm) upto 2m
Supply, installation ,testing and balancing of extruded aluminium powder coated door transfer grilles of size 600 X 150 MM.
Supply, installation and balancing of extruded aluminium powder coated air louvers complete with aluminium wire mesh birdscreen as per specifications.Fresh air louvers (with collar dampers)
Supply, installation and balancing of extruded aluminium powder coated air louvers complete with aluminium wire mesh birdscreen as per specifications. Exhaust air louvers (without volume control dampers)
Supply, installation, testing and commissioning of pressure relief damper to be installed in Lift Lobbies,Staircase & OT rooms with pre set pressure rating
Supplying and fixing of External Thermal duct insulation with 2 layer protective coating over closed cell Nitrile rubber (Class “O”) insulation on ducting after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation.All air ducts be it supply air in the return air path, both the supply and return air above the false ceiling of the conditioned space, in the conditioned space or in the non conditioned area inside the building and outside the building, shall be coated with STARBOND 30-36 / FOSTER 30-36 in conjunction with facotry laminated 7 mil woven fiber glass cloth on insulation finally finished with 2 layers of STARBOND 30-36 to provide complete seal against air and moisture complete as per specifications and as required. Insulation material for Duct shall be anti-microbial closed cell Elastomeric Nitrile Rubber. Thermal conductivity of the insulation material shall not exceed 0.038 W/moK or 0.212 BTU / (Hr-ft2-oF/inch) at an average temperature of 30oC. Density of the nitrile rubber shall be 40-60 Kg/m3. The product shall have temperature range of –40 oC to 105oC. The insulation material shall be fire rated for Class 0 as per BS 476 Part 6 : 1989 for fire propagation test and for Class 1 as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability shall be not less than 0.024 perm inch (2.48 x 10-14 Kg/m.s.Pa i.e. µ=7000: Water vapour diffusion resistance). Thermal conductivity of the material shall not be affected by ageing, as per DIN 52616 The smoke density of the material as per AS-1530.3 shall not exceed 1.The material shall be antimicrobial as per ISO 22196, C1338 and ASTM G21-96. There shall be no growth of fungus and mold. 19 mm thick (In Condition Space) with protective coating
Supplying and fixing of External Thermal duct insulation with 2 layer protective coating over closed cell Nitrile rubber (Class “O”) insulation on ducting after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation.All air ducts be it supply air in the return air path, both the supply and return air above the false ceiling of the conditioned space, in the conditioned space or in the non conditioned area inside the building and outside the building, shall be coated with STARBOND 30-36 / FOSTER 30-36 in conjunction with facotry laminated 7 mil woven fiber glass cloth on insulation finally finished with 2 layers of STARBOND 30-36 to provide complete seal against air and moisture complete as per specifications and as required. Insulation material for Duct shall be anti-microbial closed cell Elastomeric Nitrile Rubber. Thermal conductivity of the insulation material shall not exceed 0.038 W/moK or 0.212 BTU / (Hr-ft2-oF/inch) at an average temperature of 30oC. Density of the nitrile rubber shall be 40-60 Kg/m3. The product shall have temperature range of –40 oC to 105oC. The insulation material shall be fire rated for Class 0 as per BS 476 Part 6 : 1989 for fire propagation test and for Class 1 as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability shall be not less than 0.024 perm inch (2.48 x 10-14 Kg/m.s.Pa i.e. µ=7000: Water vapour diffusion resistance). Thermal conductivity of the material shall not be affected by ageing, as per DIN 52616 The smoke density of the material as per AS-1530.3 shall not exceed 1.The material shall be antimicrobial as per ISO 22196, C1338 and ASTM G21-96. There shall be no growth of fungus and mold. 25 mm thick (In Non - Condition Space) with protective coating
Supply & Installation of Acoustic Insulation of ducts with Open Cell Nitrile rubber Insulation Material with density 140-160 kg/m3 10 mm thick
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.
Supplying and erecting metal work in CRCA sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying and erecting Intelligent flush mounted panel meter three phase four wire (IPM) input voltage measurement range 50-550V AC (P-P) 415V, aux. supply 90-300 V AC/DC, flush mounted (96 x 96 mm) meter constant Wh viewing in LCD multifunction meters in auto scroll mode with voltage, current, frequency, power factor kW, kVA, kVAR, kWh, kVAh, kVARh, phase angle, interrupts, THD, complete with RS 485 communication protocol, class 1 accuracy and wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity with 99.9% aluminium purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
Providing & erecting 4 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Supplying, erecting & marking FPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 6A to 32A in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting mains with 4x25 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW
Supplying & erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW
Providing & erecting 4 Pole MCCB of 200A,415V capacity with short circuit rating 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Supplying, erecting & terminating XLPE armoured cable 4 core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 400 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standardaccessories
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 500 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Supplying, erecting & terminating XLPE armoured cable 3½ core 300 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 150 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
SITC of Oxygen Manifold System - Class-D type bulk cylinders. having Size = 20 x 20 cylinder bank system for Jumbo Cylinders as per HTM 02-01/NFPA 99/ DIN / EN / ISO-7396-1 standards, with Two high pressure header bar assemblies to facilitate connection of primary and secondary cylinder supplies & having required numbers of cylinder pigtails and NRV connections & Extension facility for additional cylinder connections with a high pressure shut off valve on each header bar and should be hydraulically tested to 3000 psig.complete along with accessories like Cylinder brackets and galvanized fixing chains
SITC of Fully Automatic Manifold Control Panel as per HTM 02-01/NFPA 99/ DIN / EN / ISO-7396-1 standards with a Minimum flow capacity should be 1500 LPM @ 50 to 60 PSI having pressure switches with actuate designated signals for Service bank status, The display shall indicate the status of the bank i9n operation along with alarm if the primary bank is exhausted. The design should comprise of Separate gauges to indicate the pressure of each header & main line and shall ensure continued supply of gas to patients immaterial of failure of any component. Pressure Regulators of panels as per BS EN 10524-2 and gauges should operate without electricity. The panel should be CE CE certified as per Medical Device Directive 93/42/EEC with approval from British Standards Institute and shall be BS EN 13485 compliant with BMS integration cpability & shall be igntion tested or adbiatic testing as per ISO 10524-2.
SITC of Emergency Manifold Header - Class-D type bulk cylinders. having Size = 10 x 10 cylinder bank system for Jumbo Cylinders as per HTM 02-01/NFPA 99/ DIN / EN / ISO-7396-1 standards, with Two high pressure header bar assemblies to facilitate connection of primary and secondary cylinder supplies & having required numbers of cylinder pigtails and NRV connections & Extension facility for additional cylinder connections with a high pressure shut off valve on each header bar and should be hydraulically tested to 3000 PSIG complete along with accessories like Cylinder brackets and galvanized fixing chains
SITC of Oxygen Flow meter with humidifier bottle as per Class I of Medical Device Directives (93/42/EEC), ISO 13485:2003 with a Back Pressure Compensated flow meter Control within a range of 0-15 LPM, meeting strict precision and durability standards. flow meter body shall be made of brass chrome plated materials, The flow tube and shroud components shall be made of clear, impact resistant polycarbonate with a large and expanded 0-15 LPM range flow tube with a stainless steel inlet and wire mesh. The humidifier bottle shall be made of unbreakable & reusable polycarbonate /polysulfone/polypropylene material autoclavable at 121 degree centigrade
SITC of N2O Manifold System - Class-D type bulk cylinders. having Size = 10 x 10 cylinder bank system for Jumbo Cylinders as per HTM 02-01/NFPA 99/ DIN / EN / ISO-7396-1 standards, with Two high pressure header bar assemblies to facilitate connection of primary and secondary cylinder supplies & having required numbers of cylinder pigtails and NRV connections as per IS 3224/ BS/ ASME incorporating a check valve at the header connection & extension facility for additional cylinder connections with a high pressure shut off valve on each header bar and should be hydraulically tested to 3000 PSIG complete it suit easy cylinder changing and positioning. along with accessories like Cylinder brackets and galvanized fixing chains
SITC of Fully Automatic Manifold Control Panel as per HTM 02-01/NFPA 99/ DIN / EN / ISO-7396-1 standards with a Minimum flow capacity should be 1500 LPM @ 50 to 60 PSI having pressure switches with actuate designated signals for Service bank status, The display shall indicate the status of the bank i9n operation along with alarm if the primary bank is exhausted. The design should comprise of Separate gauges to indicate the pressure of each header & main line and shall ensure continued supply of gas to patients immaterial of failure of any component. Pressure Regulators of panels as per BS EN 10524-2 and gauges should operate without electricity. The panel should be CE CE certified as per Medical Device Directive 93/42/EEC with approval from British Standards Institute and shall be BS EN 13485 compliant with BMS integration cpability & shall be igntion tested or adbiatic testing as per ISO 10524-2.
SITC of Emergency Manifold Header - Class-D type bulk cylinders. having Size = 5 x 5 cylinder bank system for Jumbo Cylinders as per HTM 02-01/NFPA 99/ DIN / EN / ISO-7396-1 standards, with Two high pressure header bar assemblies to facilitate connection of primary and secondary cylinder supplies & having required numbers of cylinder pigtails and NRV connections & Extension facility for additional cylinder connections with a high pressure shut off valve on each header bar and should be hydraulically tested to 3000 PSIG complete along with accessories like Cylinder brackets and galvanized fixing chains
SITC of CO2 Manifold System of 10 x 10 cylinder bank system for Jumbo Cylinders as per technical specifications. - The manifold(s) shall be comply with HTM 02-01/NFPA 99/ DIN / EN / ISO-7396-1 standards. - It shall be compatible with Class-D type bulk cylinders. - Manifold shall be consist of two high pressure header bar assemblies to facilitate connection of primary and secondary cylinder supplies. - Each header bar shall be provided with respective numbers of cylinder pigtail connections to suit cylinder valves as per IS 3224/ BS/ ASME incorporating a check valve at the header connection. - The high-pressure header bar shall be designed in such a manner that it can be extended to facilitate additional cylinder connections. - Each header bar assembly shall be provided with a high pressure shut off valve. - The manifold shall be hydraulically tested to 3000 psig. - The manifold shall be so designed that it suit easy cylinder changing and positioning. - The system shall have non – return valves for easy changing of cylinders without closing the bank. - The cylinder shall be placed with the help of cylinder brackets and fixing chains which shall be galvanized.
SITC of CO2 Manifold System Class-D type bulk cylinders. having Size = 10 x 10 cylinder bank system for Jumbo Cylinders as per HTM 02-01/NFPA 99/ DIN / EN / ISO-7396-1 standards, with Two high pressure header bar assemblies to facilitate connection of primary and secondary cylinder supplies & having required numbers of cylinder pigtails and NRV connections as per IS 3224/ BS/ ASME incorporating a check valve at the header connection & extension facility for additional cylinder connections with a high pressure shut off valve on each header bar and should be hydraulically tested to 3000 PSIG complete it suit easy cylinder changing and positioning. along with accessories like Cylinder brackets and galvanized fixing chains
SITC of Fully Automatic Manifold Control Panel as per HTM 02-01/NFPA 99/ DIN / EN / ISO-7396-1 standards with a Minimum flow capacity should be 1500 LPM @ 50 to 60 PSI having pressure switches with actuate designated signals for Service bank status, The display shall indicate the status of the bank i9n operation along with alarm if the primary bank is exhausted. The design should comprise of Separate gauges to indicate the pressure of each header & main line and shall ensure continued supply of gas to patients immaterial of failure of any component. Pressure Regulators of panels as per BS EN 10524-2 and gauges should operate without electricity. The panel should be CE CE certified as per Medical Device Directive 93/42/EEC with approval from British Standards Institute and shall be BS EN 13485 compliant with BMS integration cpability & shall be igntion tested or adbiatic testing as per ISO 10524-2.
SITC of Emergency Manifold Header - Class-D type bulk cylinders. having Size = 5 x 5 cylinder bank system for Jumbo Cylinders as per HTM 02-01/NFPA 99/ DIN / EN / ISO-7396-1 standards, with Two high pressure header bar assemblies to facilitate connection of primary and secondary cylinder supplies & having required numbers of cylinder pigtails and NRV connections & Extension facility for additional cylinder connections with a high pressure shut off valve on each header bar and should be hydraulically tested to 3000 PSIG complete along with accessories like Cylinder brackets and galvanized fixing chains
SITC of Medical Air System Two-stage, oil-free, air cooled, safety relief valves, intercooler with moisture trap and automatic drain valve, after cooler with moisture trap and manual and automatic drain valve direct driven compressor with TEFC VSD motor 3 phase, 50hz compliant with NFPA99/HTM 02-01, HTM 2022, C11, BS EN 7396,Class IIb standard supporting configuration in Duplex /Triplex /Quadruplex /Pentaplex / Hexaplex. & shall be fully enclosed in sound attenuated steel panels .The gearbox includes an oil sump, pump, oil filter, bypass valve, drain connection, sight glass and cooler with a Air intake filter and integral shutoff/unloading valve., The air discharge for the compressor module shall be a pulsation damper, check valve and manual isolation valve. Ventilation for the module shall be supplied by a radial fan with a separate motor. The control system display the runtime hours, temperature readouts, pressure readouts, service indicators, safety warnings and safety shutdowns for the compressor module. The compressor modules and motors shall be fully isolated from the main compressor module base by means of a heavy-duty isolation system for a minimum of 95% isolation efficiency. The System shall have a Duplex AIR DRYER SYSTEM including desiccant dryers, filters, and regulators sized for peak calculated demand & dew point and carbon monoxide monitoring. Desiccant dryers producing a -40°F (-40°C) pressure dew point, Dryer purge flow control through an integral dew point based purge control, 1 micron coalescing filter and a 0.01 micron high efficiency coalescing filter, 1 micron particulate filter and one active carbon filter with automatic drain and element change indicator, ceramic type dew point transmitter with accuracy of minimum + 2°C for dew point and + 2 PPM (at 10 PPM) for carbon monoxide. The control system shall be control multiple compressors and a duplexed desiccant drying system with dew point and CO transmitters including Automatic lead/lag sequencing and alternation, Visual and audible reserve unit alarm with isolated contacts for remote alarm, Automatic alternation of all compressors based on a first-on/first-off principle with provisions for simultaneous operation, Visual and audible alarm indication for high discharge air temperature shutdown with isolated contacts for remote alarm, Automatic restart after voltage failure with simultaneous start prevention with corrosion resistant piping , ASME Coded, National Board Certified galvanized receiver rated for a minimum 150 PSIG design pressure. It shall be include a liquid level glass, pressure gauge, safety relief valve, manual drain valve, and an automatic solenoid drain valve.
SITC of Surgical/Instrument Air system having Oil injected rotary screw compressors as per NFPA99/HTM 02-01, HTM 2022, C11, BS EN 7396,Class IIb standards & having Primary system capacity = 2830 lpm or 100 cfm (+/-5%) configured in Duplex/Triplex /Quadruplex /Pentaplex /Hexaplex. Including multistage oil separator capable of achieving 2ppm oil carry over, EFF1 (CEMEP) rated TEFC, IP55 class F electric motors , Touchscreen HMI system for control and log record, BMS connectivity with a mechanical back-up facility . The Duplex Desiccant type Air Dryer should be with Filters, and purifiers as per compressor capacity. Water separators, Oil filters, Dust/activated carbon filters. Dew point monitoring - -40°F (-40°C) pressure dew point. The air receiver shall be as per BS EN/ASTM standards stamped /engraved with code no./lot no along with the test certification complete along with Auto drain Valve, Gaues and Safety Valve.as required
SITC of Medical Vacuum System comprising of 400 CFM (680 m3/hr) (+/-5%) screw type, air cooled and oil lubricating type Vacuum Pumps as per the NFPA99//HTM 02-01, HTM 2022, C11, BS EN 7396,Class IIb standards configured in Duplex/Triplex/Quadruplex/Pentaplex/Hexaplex pattern having Designed vacuum below 0.5 mbar (a) & Operating vacuum level- -450 mm of hg ( 310 mbar.a) to -660 mm of hg( 100 mbar.a) with a Variable frequency Drive Inverter based starter having overload trip, air/oil high temperature trip / alarm, Inbuilt protection for starting on load. The IP-55 rated totally enclosed direct drive fan cooled motor of IE3 standard with noise level below 70 db. It should have a microprocessor based control system supporting the following functions Dual Vacuum set point., Start/stop, Load/unload, Emergency stop, Reset, safety shutdowns, Service Alarm, Failure history data, Electronically controlled gas ballast and temperature management and shall be operational at 46 Deg.C ambient temperature. The duplex vacuum bacterial filters of at least 99.999% efficiency when tested by the sodium flame method in accordance with BS 3928:1969/as per required standard utilizing particles in the 0.02 to 2 micron size range shall be designed for removal of solid, liquid and bacterial contamination from the suction side of vacuum pump systems, preventing damage to the pump and the potential biological infection of the surrounding environment with a transparent sterilizable collection jar to collect condensate.
SITC of CE Certified Ward Vacuum Unit of 0-760 mm Hg range adhering to Class I of Medical Device Directives & ISO 13485:2003 with an 1 no of analog Suction Regulator and 1no of 1000 ml polysulfide /polycarbonate/polypropylene collection jar, autoclavable at 121º C, unbreakable, fitted with an anti-overflow safety device and equipped with a plastic antibacterial filter and an anti-overflow safety device & a wide membrane continuous suction controller & On/off knob for restoration of a readjusted vacuum level
SITC of CE certified Theatre Suction Trolley adhering to Class I of Medical Device Directives (93/42/EEC & ISO 13485:2003. With 1 regulator having trolley stand mounted gauge having reusable unbreakable trolley mounted plastic collection bottles of 2000 ml each fully auto-cleavable at 121°C.
SITC of Duplex AGSS Remote Switch panel with24V control and indication circuit having indicator lamps in different colours for Normal operation, Plant Emergency & PLANT FAULT
SITC AGSS Receiver & Transfer Hose assembly comprising of 22mm corrugated tube, 30mm male adaptor for disposal hose assembly, and a transfer hose assembly and a 10cm H2O pressure relief valve (PRV).
SITC of Gas Terminal Units for Oxygen as per technical specifications
SITC of Gas Terminal Units for Nitorus Oxide as per technical specifications
SITC of Gas Terminal Units for Medical Air as per technical specifications
SITC of Gas Terminal Units for Instrument Air as per technical specifications
SITC of Gas Terminal Units for Vacuum as per technical specifications
SITC of Gas Terminal Units for CO2 as per technical specifications
SITC of Compatabile Stainless Steel Probes/Adaters for Gas Outlets & Plastic Mounting Box for Oxygen
SITC of Compatabile Stainless Steel Probes/Adaters for Gas Outlets & Plastic Mounting Box for Nitorus Oxide
SITC of Compatabile Stainless Steel Probes/Adaters for Gas Outlets & Plastic Mounting Box for Medical Air
SITC of Compatabile Stainless Steel Probes/Adaters for Gas Outlets & Plastic Mounting Box for Instrument Air
SITC of Compatabile Stainless Steel Probes/Adaters for Gas Outlets & Plastic Mounting Box forVacuum
SITC of Compatabile Stainless Steel Probes/Adaters for Gas Outlets & Plastic Mounting Box for CO2
SITC of CE Certified Medical Gas Area Line Pressure Alarm conforming from notified body having 4 digit notified body number under class IIa category for HTM0201/ ISO DIN EN 7396 manufactured from impact resistance, rigid and inherently corrosion proof materials, with a LCD Touch screen simultaneously Monitoring 6 different gas services having an audible Alarm with a Mute facility which should automatically resound in 15 minutes if the gas service doesn’t return to normal, Self test function, BMS Compatibility, Brass Pressure and Vacuum Switches with high & Low pressure facility, SITC of Touch Screen Medical Gas Alarms for 2 Gas Services as per technical specifications
SITC of CE Certified Medical Gas Area Line Pressure Alarm conforming from notified body having 4 digit notified body number under class IIa category for HTM0201/ ISO DIN EN 7396 manufactured from impact resistance, rigid and inherently corrosion proof materials, with a LCD Touch screen simultaneously Monitoring 6 different gas services having an audible Alarm with a Mute facility which should automatically resound in 15 minutes if the gas service doesn’t return to normal, Self test function, BMS Compatibility, Brass Pressure and Vacuum Switches with high & Low pressure facility, SITC of Touch Screen Medical Gas Alarms for 3 Gas Services as per technical specifications
SITC of CE Certified Medical Gas Area Line Pressure Alarm conforming from notified body having 4 digit notified body number under class IIa category for HTM0201/ ISO DIN EN 7396 manufactured from impact resistance, rigid and inherently corrosion proof materials, with a LCD Touch screen simultaneously Monitoring 6 different gas services having an audible Alarm with a Mute facility which should automatically resound in 15 minutes if the gas service doesn’t return to normal, Self test function, BMS Compatibility, Brass Pressure and Vacuum Switches with high & Low pressure facility, SITC of Touch Screen Medical Gas Alarms for 4 Gas Services as per technical specifications
SITC of CE Certified Medical Gas Area Line Pressure Alarm conforming from notified body having 4 digit notified body number under class IIa category for HTM0201/ ISO DIN EN 7396 manufactured from impact resistance, rigid and inherently corrosion proof materials, with a LCD Touch screen simultaneously Monitoring 6 different gas services having an audible Alarm with a Mute facility which should automatically resound in 15 minutes if the gas service doesn’t return to normal, Self test function, BMS Compatibility, Brass Pressure and Vacuum Switches with high & Low pressure facility, .SITC of Touch Screen Medical Gas Alarms for 6 Gas Services as per technical specifications
SITC of CE Certified Maintenance free Microprocessor controlled Network based Master Alarm panel conforming from notified body having 4 digit notified body number under class IIa category for HTM0201/ ISO DIN EN 7396 as per latest NFPA99 standard. with American UL/ETL/ATL listed certificate., BMS Connectivity, Health monitoring of each gas separately on a built-in LCD Display indicating 0-250 psi for positive pressure and 0-30 inch Hg for vacuum, Field Expandable alarms up to 25-60 Local inputs. IOT based web server displaying web page, alarm signals, pressures, and other networked devices, bar graph trend indicator indicating a green “NORMAL”, yellow “CAUTION” and a red “HIGH” or “LOW” alarm condition having default set points with +/- 20% variation from normal condition.
SITC of Zone Valve Box with Valves & Gauges conforming NFPA 99/HTM 02-01, BS EN 18082 and C11 constructed of 18 gauge steel/aluminium with protective enamel finish sliding /door type, opaque door with pull ring and clear gauge window adjusting for variances in wall thickness up to 1”, 600 WOG rated Ball valves with Teflon seats and adjusting stem packing gland with Teflon stem seal actuate from full “ON” to full “OFF” by 90 degree turn of vinyl gripped valve handle with factory installed type K copper tubing extensions complete with a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum include a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum & piped left to right with right being on patient side, Gas venting as per BS EN 11197.SITCof Imported Zonal Valve Box for 2 Gas Services as per technical specifications.
SITC of Zone Valve Box with Valves & Gauges conforming NFPA 99/HTM 02-01, BS EN 18082 and C11 constructed of 18 gauge steel/aluminium with protective enamel finish sliding /door type, opaque door with pull ring and clear gauge window adjusting for variances in wall thickness up to 1”, 600 WOG rated Ball valves with Teflon seats and adjusting stem packing gland with Teflon stem seal actuate from full “ON” to full “OFF” by 90 degree turn of vinyl gripped valve handle with factory installed type K copper tubing extensions complete with a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum include a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum & piped left to right with right being on patient side, Gas venting as per BS EN 11197.SITCof Imported Zonal Valve Box for 3 Gas Services as per technical specifications.
SITC of Zone Valve Box with Valves & Gauges conforming NFPA 99/HTM 02-01, BS EN 18082 and C11 constructed of 18 gauge steel/aluminium with protective enamel finish sliding /door type, opaque door with pull ring and clear gauge window adjusting for variances in wall thickness up to 1”, 600 WOG rated Ball valves with Teflon seats and adjusting stem packing gland with Teflon stem seal actuate from full “ON” to full “OFF” by 90 degree turn of vinyl gripped valve handle with factory installed type K copper tubing extensions complete with a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum include a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum & piped left to right with right being on patient side, Gas venting as per BS EN 11197.SITCof Imported Zonal Valve Box for 4 Gas Services as per technical specifications.
SITC of Zone Valve Box with Valves & Gauges conforming NFPA 99/HTM 02-01, BS EN 18082 and C11 constructed of 18 gauge steel/aluminium with protective enamel finish sliding /door type, opaque door with pull ring and clear gauge window adjusting for variances in wall thickness up to 1”, 600 WOG rated Ball valves with Teflon seats and adjusting stem packing gland with Teflon stem seal actuate from full “ON” to full “OFF” by 90 degree turn of vinyl gripped valve handle with factory installed type K copper tubing extensions complete with a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum include a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum & piped left to right with right being on patient side, Gas venting as per BS EN 11197.SITCof Imported Zonal Valve Box for 6 Gas Services as per technical specifications.
SITC Line Isolation Valves (Medical Gas Valves) conforming NFPA 99/HTM 02-01, BS EN 18082 and C11, 600 WOG rated Ball valves with Teflon seats and adjusting stem packing gland with Teflon stem seal actuate from full “ON” to full “OFF” by 90 degree turn of vinyl gripped valve handle with factory installed type K copper tubing extensions complete with a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum include a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum & piped left to right with right being on patient side, Gas venting as per BS EN 11197.SITC of Imported Line Isolation/Shut off Valves 15mm as per technical specifications.
SITC Line Isolation Valves (Medical Gas Valves) conforming NFPA 99/HTM 02-01, BS EN 18082 and C11, 600 WOG rated Ball valves with Teflon seats and adjusting stem packing gland with Teflon stem seal actuate from full “ON” to full “OFF” by 90 degree turn of vinyl gripped valve handle with factory installed type K copper tubing extensions complete with a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum include a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum & piped left to right with right being on patient side, Gas venting as per BS EN 11197.SITC of Imported Line Isolation/Shut off Valves 22mm as per technical specifications.
SITC Line Isolation Valves (Medical Gas Valves) conforming NFPA 99/HTM 02-01, BS EN 18082 and C11, 600 WOG rated Ball valves with Teflon seats and adjusting stem packing gland with Teflon stem seal actuate from full “ON” to full “OFF” by 90 degree turn of vinyl gripped valve handle with factory installed type K copper tubing extensions complete with a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum include a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum & piped left to right with right being on patient side, Gas venting as per BS EN 11197.SITC of Imported Line Isolation/Shut off Valves 28mm as per technical specifications.
SITC Line Isolation Valves (Medical Gas Valves) conforming NFPA 99/HTM 02-01, BS EN 18082 and C11, 600 WOG rated Ball valves with Teflon seats and adjusting stem packing gland with Teflon stem seal actuate from full “ON” to full “OFF” by 90 degree turn of vinyl gripped valve handle with factory installed type K copper tubing extensions complete with a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum include a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum & piped left to right with right being on patient side, Gas venting as per BS EN 11197.SITC of Imported Line Isolation/Shut off Valves 42mm as per technical specifications.
SITC Line Isolation Valves (Medical Gas Valves) conforming NFPA 99/HTM 02-01, BS EN 18082 and C11, 600 WOG rated Ball valves with Teflon seats and adjusting stem packing gland with Teflon stem seal actuate from full “ON” to full “OFF” by 90 degree turn of vinyl gripped valve handle with factory installed type K copper tubing extensions complete with a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum include a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum & piped left to right with right being on patient side, Gas venting as per BS EN 11197.SITC of Imported Line Isolation/Shut off Valves 54mm as per technical specifications.
SITC Line Isolation Valves (Medical Gas Valves) conforming NFPA 99/HTM 02-01, BS EN 18082 and C11, 600 WOG rated Ball valves with Teflon seats and adjusting stem packing gland with Teflon stem seal actuate from full “ON” to full “OFF” by 90 degree turn of vinyl gripped valve handle with factory installed type K copper tubing extensions complete with a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum include a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum & piped left to right with right being on patient side, Gas venting as per BS EN 11197.SITC of Imported Line Isolation/Shut off Valves 76mm as per technical specifications.
SITC Line Isolation Valves (Medical Gas Valves) conforming NFPA 99/HTM 02-01, BS EN 18082 and C11, 600 WOG rated Ball valves with Teflon seats and adjusting stem packing gland with Teflon stem seal actuate from full “ON” to full “OFF” by 90 degree turn of vinyl gripped valve handle with factory installed type K copper tubing extensions complete with a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum include a 1 1/2 inch pressure gauge reading 0 to 100 psig for oxygen, air, nitrous oxide; 0 to 300 psig for nitrogen; and 0 to 30 HG for vacuum & piped left to right with right being on patient side, Gas venting as per BS EN 11197.SITC of Imported Line Isolation/Shut off Valves 108mm as per technical specifications.
SITC CE Certified Factory assembled Horizontal/ Vertical Bed Head Panel conforming to /HTM 02-01/ NFPA 99/EN/DIN/ISO 7396-1 standards, constructed in extruded aluminium section of 1200mm upto 2 Gas Outlets & 1500mm for up to 4/5 outlets configuration & 1800mm for 6/8 Outlet configurations along with electrical switches, Customised design with Smooth curved surfaces with integrated rail system, Segregation of services i.e. Low voltage supplies, High Voltage supply and Medical gases shall be maintained with minimum 2 tier/2 channel arrangements, individually removable front fascia plate with electrical and electrical outlets pre-fitted.SITC of Horizontal/Vertical Bed Head Panel 1200mm as per technical specifications.
SITC CE Certified Factory assembled Horizontal/ Vertical Bed Head Panel conforming to /HTM 02-01/ NFPA 99/EN/DIN/ISO 7396-1 standards, constructed in extruded aluminium section of 1200mm upto 2 Gas Outlets & 1500mm for up to 4/5 outlets configuration & 1800mm for 6/8 Outlet configurations along with electrical switches, Customised design with Smooth curved surfaces with integrated rail system, Segregation of services i.e. Low voltage supplies, High Voltage supply and Medical gases shall be maintained with minimum 2 tier/2 channel arrangements, individually removable front fascia plate with electrical and electrical outlets pre-fitted.SITC of Horizontal/Vertical Bed Head Panel 1800mm as per technical specifications.
Sitc of Copper Pipes Solid drawn, seamless, deoxidized, non-arsenical, half hard (hard can be accepted only for sizes 54mm or more), tempered and degreased copper pipe conforming to BS: EN 13348:2008 standards degreased & delivered capped at both ends along with Manufacturers test certification and third party inspection certificate (Eg. Lloyd’s or TUV or SGS). Copper fittings complying with EN 1254:1 & brazing filler metals complying with EN 1044 must be suitable for a working Pressure of up to 17bar fixed on suitable nonferrous or non-deteriorating plastic clamps , Inert gas welding technique shall be used by passing oxygen Free Nitrogen Gas inside the copper pipes during silver brazing without flux on joints brazed using a 5% silver-copper phosphorous brazing alloy CP104, The insides shall be clean and free from oxides and particulate matter and the minimum penetration of the brazing alloy at any point shall be three times the wall thickness of the tube. After erection, the pipes to be flushed with dry nitrogen gas and then pressure tested with dry nitrogen at a pressure equal to twice the working pressure or 150 psig, whichever is higher for a period of not less than 24 hours & must be painted with two coats of synthetic enamel paint and colour codification shall be as per standards followed and with consultation with competent authorities of the user department..SITC of Copper Pipes with Copper Fitings 108mm dia X 2.0mm thick as per technical specifications.
Sitc of Copper Pipes Solid drawn, seamless, deoxidized, non-arsenical, half hard (hard can be accepted only for sizes 54mm or more), tempered and degreased copper pipe conforming to BS: EN 13348:2008 standards degreased & delivered capped at both ends along with Manufacturers test certification and third party inspection certificate (Eg. Lloyd’s or TUV or SGS). Copper fittings complying with EN 1254:1 & brazing filler metals complying with EN 1044 must be suitable for a working Pressure of up to 17bar fixed on suitable nonferrous or non-deteriorating plastic clamps , Inert gas welding technique shall be used by passing oxygen Free Nitrogen Gas inside the copper pipes during silver brazing without flux on joints brazed using a 5% silver-copper phosphorous brazing alloy CP104, The insides shall be clean and free from oxides and particulate matter and the minimum penetration of the brazing alloy at any point shall be three times the wall thickness of the tube. After erection, the pipes to be flushed with dry nitrogen gas and then pressure tested with dry nitrogen at a pressure equal to twice the working pressure or 150 psig, whichever is higher for a period of not less than 24 hours & must be painted with two coats of synthetic enamel paint and colour codification shall be as per standards followed and with consultation with competent authorities of the user department..SITC of Copper Pipes with Copper Fitings 76mm dia X 1.5mm thick as per technical specifications.
Sitc of Copper Pipes Solid drawn, seamless, deoxidized, non-arsenical, half hard (hard can be accepted only for sizes 54mm or more), tempered and degreased copper pipe conforming to BS: EN 13348:2008 standards degreased & delivered capped at both ends along with Manufacturers test certification and third party inspection certificate (Eg. Lloyd’s or TUV or SGS). Copper fittings complying with EN 1254:1 & brazing filler metals complying with EN 1044 must be suitable for a working Pressure of up to 17bar fixed on suitable nonferrous or non-deteriorating plastic clamps , Inert gas welding technique shall be used by passing oxygen Free Nitrogen Gas inside the copper pipes during silver brazing without flux on joints brazed using a 5% silver-copper phosphorous brazing alloy CP104, The insides shall be clean and free from oxides and particulate matter and the minimum penetration of the brazing alloy at any point shall be three times the wall thickness of the tube. After erection, the pipes to be flushed with dry nitrogen gas and then pressure tested with dry nitrogen at a pressure equal to twice the working pressure or 150 psig, whichever is higher for a period of not less than 24 hours & must be painted with two coats of synthetic enamel paint and colour codification shall be as per standards followed and with consultation with competent authorities of the user department..SITC of Copper Pipes with Copper Fitings 54mm dia X 1.2mm thick as per technical specifications.
Sitc of Copper Pipes Solid drawn, seamless, deoxidized, non-arsenical, half hard (hard can be accepted only for sizes 54mm or more), tempered and degreased copper pipe conforming to BS: EN 13348:2008 standards degreased & delivered capped at both ends along with Manufacturers test certification and third party inspection certificate (Eg. Lloyd’s or TUV or SGS). Copper fittings complying with EN 1254:1 & brazing filler metals complying with EN 1044 must be suitable for a working Pressure of up to 17bar fixed on suitable nonferrous or non-deteriorating plastic clamps , Inert gas welding technique shall be used by passing oxygen Free Nitrogen Gas inside the copper pipes during silver brazing without flux on joints brazed using a 5% silver-copper phosphorous brazing alloy CP104, The insides shall be clean and free from oxides and particulate matter and the minimum penetration of the brazing alloy at any point shall be three times the wall thickness of the tube. After erection, the pipes to be flushed with dry nitrogen gas and then pressure tested with dry nitrogen at a pressure equal to twice the working pressure or 150 psig, whichever is higher for a period of not less than 24 hours & must be painted with two coats of synthetic enamel paint and colour codification shall be as per standards followed and with consultation with competent authorities of the user department..SITC of Copper Pipes with Copper Fitings 42mm dia x 1.0mm thick as per technical specifications.
Sitc of Copper Pipes Solid drawn, seamless, deoxidized, non-arsenical, half hard (hard can be accepted only for sizes 54mm or more), tempered and degreased copper pipe conforming to BS: EN 13348:2008 standards degreased & delivered capped at both ends along with Manufacturers test certification and third party inspection certificate (Eg. Lloyd’s or TUV or SGS). Copper fittings complying with EN 1254:1 & brazing filler metals complying with EN 1044 must be suitable for a working Pressure of up to 17bar fixed on suitable nonferrous or non-deteriorating plastic clamps , Inert gas welding technique shall be used by passing oxygen Free Nitrogen Gas inside the copper pipes during silver brazing without flux on joints brazed using a 5% silver-copper phosphorous brazing alloy CP104, The insides shall be clean and free from oxides and particulate matter and the minimum penetration of the brazing alloy at any point shall be three times the wall thickness of the tube. After erection, the pipes to be flushed with dry nitrogen gas and then pressure tested with dry nitrogen at a pressure equal to twice the working pressure or 150 psig, whichever is higher for a period of not less than 24 hours & must be painted with two coats of synthetic enamel paint and colour codification shall be as per standards followed and with consultation with competent authorities of the user department..SITC of Copper Pipes with Copper Fitings 28mm dia x 1.0mm thick as per technical specifications.
Sitc of Copper Pipes Solid drawn, seamless, deoxidized, non-arsenical, half hard (hard can be accepted only for sizes 54mm or more), tempered and degreased copper pipe conforming to BS: EN 13348:2008 standards degreased & delivered capped at both ends along with Manufacturers test certification and third party inspection certificate (Eg. Lloyd’s or TUV or SGS). Copper fittings complying with EN 1254:1 & brazing filler metals complying with EN 1044 must be suitable for a working Pressure of up to 17bar fixed on suitable nonferrous or non-deteriorating plastic clamps , Inert gas welding technique shall be used by passing oxygen Free Nitrogen Gas inside the copper pipes during silver brazing without flux on joints brazed using a 5% silver-copper phosphorous brazing alloy CP104, The insides shall be clean and free from oxides and particulate matter and the minimum penetration of the brazing alloy at any point shall be three times the wall thickness of the tube. After erection, the pipes to be flushed with dry nitrogen gas and then pressure tested with dry nitrogen at a pressure equal to twice the working pressure or 150 psig, whichever is higher for a period of not less than 24 hours & must be painted with two coats of synthetic enamel paint and colour codification shall be as per standards followed and with consultation with competent authorities of the user department.SITC of Copper Pipes with Copper Fitings 22mm dia X 1.0mm thick as per technical specifications.
Sitc of Copper Pipes Solid drawn, seamless, deoxidized, non-arsenical, half hard (hard can be accepted only for sizes 54mm or more), tempered and degreased copper pipe conforming to BS: EN 13348:2008 standards degreased & delivered capped at both ends along with Manufacturers test certification and third party inspection certificate (Eg. Lloyd’s or TUV or SGS). Copper fittings complying with EN 1254:1 & brazing filler metals complying with EN 1044 must be suitable for a working Pressure of up to 17bar fixed on suitable nonferrous or non-deteriorating plastic clamps , Inert gas welding technique shall be used by passing oxygen Free Nitrogen Gas inside the copper pipes during silver brazing without flux on joints brazed using a 5% silver-copper phosphorous brazing alloy CP104, The insides shall be clean and free from oxides and particulate matter and the minimum penetration of the brazing alloy at any point shall be three times the wall thickness of the tube. After erection, the pipes to be flushed with dry nitrogen gas and then pressure tested with dry nitrogen at a pressure equal to twice the working pressure or 150 psig, whichever is higher for a period of not less than 24 hours & must be painted with two coats of synthetic enamel paint and colour codification shall be as per standards followed and with consultation with competent authorities of the user department..SITC of Copper Pipes with Copper Fitings 15mm dia X 1.0mm thick as per technical specifications.
Sitc of Copper Pipes Solid drawn, seamless, deoxidized, non-arsenical, half hard (hard can be accepted only for sizes 54mm or more), tempered and degreased copper pipe conforming to BS: EN 13348:2008 standards degreased & delivered capped at both ends along with Manufacturers test certification and third party inspection certificate (Eg. Lloyd’s or TUV or SGS). Copper fittings complying with EN 1254:1 & brazing filler metals complying with EN 1044 must be suitable for a working Pressure of up to 17bar fixed on suitable nonferrous or non-deteriorating plastic clamps , Inert gas welding technique shall be used by passing oxygen Free Nitrogen Gas inside the copper pipes during silver brazing without flux on joints brazed using a 5% silver-copper phosphorous brazing alloy CP104, The insides shall be clean and free from oxides and particulate matter and the minimum penetration of the brazing alloy at any point shall be three times the wall thickness of the tube. After erection, the pipes to be flushed with dry nitrogen gas and then pressure tested with dry nitrogen at a pressure equal to twice the working pressure or 150 psig, whichever is higher for a period of not less than 24 hours & must be painted with two coats of synthetic enamel paint and colour codification shall be as per standards followed and with consultation with competent authorities of the user department..SITC of Copper Pipes with Copper Fitings 12mm dia x 1.0mm thick as per technical specifications.
SITC of Electrical Control Panel for Vacuum pumps & Air Compressors. Modular Compartmentalized floor mounted PMCC with IP 54, Form 3B type having NDO MO FROH 35 kA TPN MCCB 1 no.80 A incomer+4 no. Auto Star minimum 15 kW Delta starter complete with 40 A TP Curve C 10 kA MCB- 32 A Line -32 A Run – 12 A Star AC3 duty contactor electronic timer- 14-20 A O/L+SPP relay- A/M & L/R switch-R/G/A lamps-R/G/B pushbuttons etc for Air & Form 3B type having NDO MO FROH 35 kA TPN MCCB 1 no.80 A incomer+4 no. Auto Star minimum 7.5 kW Delta starter complete with 25 A TP Curve C 10 kA MCB- 25 A Line -25 A Run – 12 A Star AC3 duty contactors- electronic timer- 7.5-10 A O/L+SPP relay- A/M & L/R switch-R/G/A lamps-R/G/B pushbuttons etc for Vacuum
Supplying, erecting & terminating XLPE armoured cable 3½ core 150 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG)G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no.CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG)G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no.CB-LT/CU
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
SITC of Liquid Oxygen Tank of 20KL + 10KL with vaporiser Designed as per ASME Sec.VIII Div.I Latest Edition/EN 13458-2 Annexure –C/AD2000 MARKBLATTER 2004 Edition Max working pressure : 17 Bar G, Design temperature : - 196⁰C to + 50⁰C, Hydraulic test pressure : 26 bar G, Type of Insulation : Vacuum, Perlite filled, Safety Valve Set pressure : 17 Bar G (dual safety valve with three way diverter valve), Bursting Disc Set pressure : 23 Bar G (Bursting disc) having Capacity of Minimum 20000 ltrs water capacity- 1 No and Minimum 10000 litres water capacity – 1No , The double walled Vacuum Insulated Evaporator constructed of stainless steel inner vessel contained within a carbon steel outer vessel with annular space between the vessels filled with non-inflammable perlite insulation material to insulate under vacuum & self-pressurizing type VIE by partial evaporation of liquid oxygen through a pressure building coil by a non-ferrous imported pressure regulator supplied as a functional whole with all materials of construction & the cleaning regime suitable for medical grade liquid oxygen., complete with Standard fittings : Pressure rising coil, Pressure building regulator of adequate capacity and size, dual safety valve with three way diverter valve, bursting disc., pressure gauges, liquid over flow line, Liquid level gauge and adequate numbers of extended spindle glove valve etc & Maximum Evaporation Rate : <0.35% of net value , Constructed Inner shell and wetted parts of SS-304 Outer shell of CS ASTMA 516 Gr.70/CG3412002 EN13455 S275/S355, Radiography : 100% for inner, for outer spot, external piping : from LMO Tank to Vaporizer SS304 From Vaporizer to Inlet of Pressure Reducing Station SS304 From Outlet of Pressure Reducing Station to Main header Copper, & conforming to all international safety norms and standards applicable as implemented and certified by the CCOE., having the following Vessel low liquid level alarm, Vessel low pressure alarm, Pipeline low pressure alarm., Twin regulator, Non return valve and 3 way diverter (bypass) valve, Automatic changeover to manifolds with control panel, Alarm on indicating manifold in use in case the vessel is not in use., Alarm on low pressure back-upmanifold cylinders, Two safety valves for inner vessel fitted on pipe line with flow divert valve., Rupture disc for inner vessel, Safety valve for inlet pipeline, Safety valve for pipeline of pressurizing evaporator, One rupture disc/safety device on outer vessel, and having the following Approvals letter from CCOE along with approved drawing from CCOE., Approval letter from CCOE for use of cryogenic vessel(s) at site., Certificate from the authorized inspection agency., Heat chart for pressure parts., Dimension checks parts., Dished End reports., Mechanical properties test reports., Visual inspection report., Radiography examination report., Liquid penetrant examination., Cleaning inspection report., Hydro-pressure test report., Pneumatic pressure test report., Inner vessel rub-off sheet., Material test reports for pressure gauges, level gauge etc, All valves shall be long stem valves with SS body
GODREJ and BOYCE Mfg. Co. Ltd.