Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-Finance | L1 | Accepted-Finance Lowest Bidder | |
| 2 | L2₹38.3 L+₹594.50 (0.02%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹38.5 L+₹18,356.90 (0.48%)Rejected-Finance 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹38.9 L+₹54,418.86 (1.42%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹39.7 L+₹1.3 L (3.49%)Rejected-Finance PEMASAR ROAD WARD NO 04 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹43.4 L
EMD Value
₹86,800
Closing Date
27 Nov 2021, 6:00 pmClosed
GE North Bikaner
GE North Bikaner
PROVN OF ROOF TREATMENT OF BLDG NO P20 P 21 AND P25 DHOBI GHAT AND PROVN OF INTER LOCKING TILE PATH AT CERTAIN UNITS AT MIL STN BIKANER.
2021_MES_484775_1
GE (N) BKN TOKEN NO 61/2021-2022
Open Tender
Civil Works
Item Rate
270 days
BIKANER
Class D category a i
8 documents required · 8 mandatory
₹500
GE North Bikaner
₹86,800
Yes
6 Dec 2021
29 Oct 2021
29 Nov 2021
29 Oct 2021
27 Nov 2021
13 Nov 2021
Amount
Dismantling of Roof tiles/Mud faska of any description or thickness in floor, apron etc laid, bedded and pointed in cement mortar complete all as specified and as directed by Engineer-in-Charge.
Demolition of lime concrete of any description over roof slab complete all as specified as directed by Engr-in-charge
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified.
Demolition of reinforced cement concrete Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work. complete all as specified and directed.
Demolition of brick work or stone boulder masonary of any description in and any position built in cement mortar or cement lime mortar complete.
Demolition and breaking up drain pipes of internal Dia 150mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.
Taking down cement plaster on brick , concrete or stone walll etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed
Dismantling floor, hearth or wall tiling any type including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the primises Complete.
Dismantling and disconnecting of existing CI soil vent pipe upto 100 mm bore fixed to wall,laid in trenches incl all fittings & accessories.
Taking down chowkhats or frames not exc. 1.50 Sqm each but with shutter (with out taking of shutter from the frame ) and making good the surface of walls as per existing with cement mortar complete.
Taking down chowkhats or frames exc. 1.50 Sqm each but n.exc 4 Sqm with shutter (with out taking of shutter from the frame ) and making good the surface of walls as per existing with cement mortar complete all as specified.
Taking down shutter of any description. exc. 1.00 sqm each complete all as specified.
Taking down shutter of any description exc. 1.00 sqm but not exc.2.00 sqm each and refixing the same door in same opening after easening etc complete.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete.
Taking up or down 20mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil.
M&L for RCC, M-25 (Design Mix) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC, M-25 (Design Mix) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for RCC, M-25 (Design Mix) as in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for RCC, M-25 (Design Mix) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use & waste of formwork (rough finished) to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work,
Use & waste of formwork (rough finished) to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
Use & waste of formwork (rough finished) to sides of pillars, posts, struts, piers, columns and stanchions square/ rectangular .
Use & waste of formwork (rough finished) to sides of pillars, posts, struts, piers, columns and stanchions square/ rectangular for rough finished surfaces.
Use & waste of formwork (rough finished) to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide .
M&L for TMT steel bars 10mm dia and over cut to length bent to shape reqd incl cranking bending spirally for hooping for columns hooking ends and binding with m.s wire annealed not less than 0.9mm dia
All as per item No 27 here in before but 6mm to 8mm dia.
All as per item No 27 here in before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil.
Returning filling in including spreading leveling and well ramming in layers n.exc 25 cm thick
Removal of surplus soil n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point.
M&L for Brick work with fly ash bricks (Old size) , straight or curved on plan exc. 6 m mean radius built in CM 1:6 complete all as specified as directed by Engineer-in-charge .
M&L for hard core of broken bricks /63mm broken stone of gauge not exceeding 63 mm spreading, leveling,watering and well ramming to a true surface as in plinth proctions etc.
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base 75mm thick in floors.
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base100mm thick in floors.
M&L for Machine pressed precast concrete interlocking paver block any shape and size with pigment(Coloured Blocks) confirming to IS 15658-2006 of 80 mm thickness M-40 Grade
Sand filling under floors or in foundation including watering and consolidation
M&L for rendering 15mm thick in CM (1:6) on other than fair faces of brick work finished surfaces even and smooth without using extra cement all as specified and directed.
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work , finished surfaces even and smooth without using extra cement all as specified and directed.
M&L for rendering 10mm thick in CM (1:3) on concrete ceiling surfaces finished even and smooth without using extra cement all as specified and directed.
M&L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection ,75mm thick finished even and smooth withoput using cement.
M & L for PCC 1:3:6 type B-1 (using 20mm Graded Stone Aggregate) as in fixing Holdfast, coping, filling of chowkhats etc., complete all as specified and as directed by Engr-in-Charge.
M&L for cement concrete 1:2:4 Type B-1 (using 20mm graded Aggr) as in surface channels and drain complete all as specified and directed.
M&L for cement concrete 1:2:4 Type B-1 (using 20mm graded Aggr) as foundations, filling and mass concrete complete all as specified and directed.
M & L for providing PCC 1:2:4 type B-0, using 12.5mm graded aggregate in roof kerb and mud stops rounded or champhered on edge incl form work complete all as specified and directed.
M&L for PCC, 1:3:6 type C-2 as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in PCC1:3:6 type C-2
M&L for 150mm drain pipe Salt glazed stoneware drain pipes, grade “A’ laid in trenches and jointed in CM 1:4. complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required
M&L for rendering 10mm thick in CM (1:4) on fair concrete / Brick surface , finished fair and even incl mixing of WPC as per manufacturer's instruction complete all as specified and directed.
M&L for applying a priming coat of cold bitumen primer @ 0.70 ltr/sqm as per para 11.44.5 of MES SSR Part-I complete.
Prepairing surface and cleaning of conc slab by bwire brushing and applying evenly a tack coat of 85/25 at the rate of 1.25 Kg /sqm incl cleaning surface complete all as specified and directed.
M & L for lime concrete terracing as on roof with mimimum thickness of edge 40 mm and increasing uniformly towards ridge to obtain a certain chain slope of (1:40) as described in para 11.27.2 of MES SSR part-I complete all as specified. NOTE:- For lime concrete, mudia kankar (source : NAL) and Kolayat coarse sand in lieu of brick aggregates and Surkhi respectively as specified in MES schedule Part-I shall be used.
M& L 40 mm thick brick tiles bedded on 15mm thick CM 1:3 and joints grouted flush in cement and sand mortar (1:3) mixed with 5% of crude oil by weight of cement complete
M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified
Providing precast reinforced cement concrete 1:2:4 Type B-1 (using 20mm graded Aggr) as in cover as in manhole sheelves etc set in cement mortar 1:4 and the like complete all as specified and Directed.
M & L for 18-20 mm thick Machine cut Kota stone slab flooring laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and Wax polishing including laid over 20 mm thick screed bed in cement mortar 1:4 complete all as specified.
M & L for 15-18 mm thick Machine cut Kota stone in riser to steps, skirting, dado and pillar etc on vertical surfaces laid over 10 mm thick cement plaster in 1:4 complete all as specified.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick set and jointed in neat cement slurry and pointed to match the surfaces in floors, area exc 0.06 sqm but n.exc 0.11sqm jointed in neat cment slurry and pointed with white cement mixed with pigments matching with tiles complete over 15mm thick cement screed in CM 1:6 all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick set and jointed in neat cement slurry and pointed to match the surfaces in floors, area exc 0.11 sqm but n.exc 0.18sqm jointed in neat cment slurry and pointed with white cement mixed with pigments matching with tiles complete over 15mm thick cement screed in CM 1:6 all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick set and jointed in neat cement slurry and pointed to match the surfaces in skirting/dado , area exc 0.16 sqm but n.exc 0.36sqm jointed in neat cment slurry and pointed with white cement mixed with pigments matching with tiles complete over 15mm thick cement screed in CM 1:6 all as specified and directed.
M&L for ceramic glazed coloured tiles350x 250x 7 mm/ 450X 350X 7mm thick in skirting/dado etc set and jointed in neat cement slurry over 10mm thick rendering in CM 1:4 and pointed to match the surfaces etc complete.
Supply only liquid water proofing compound ISI Mark complete. Make: Dr. Fixit or Equivalent.
S &F vitreous china squatting pan of orissa patten of size 630 x 450mm white, back inlet with integral foot rests including connection to trap and to flushing pipe, anti-syphonage pipe etc, fixed in repair complete and making good to floor in cement mortar 1:3 complete all as specified and as directed by Engineer-in-charge .
S & F for pressed steel frames of size 125 x 60 mm with one or more rebates including necessary fixing lugs hinges, locks trike plate etc (thickness of sheet shall be 1.25mm) and making good the plaster of wall in CM 1:6 complete all as specified.
S & F for pressed steel frames of size 105 x 60 mm with one or more rebates including necessary fixing lugs hinges, locks strike plate etc (thickness of sheet shall be 1.25mm) and making good the plaster of wall in CM 1:6 complete all specified.
S&F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified and approved.
S&F 35mm thick Second class hardwood plain ,framed, panelled shutter (any no panels) with panels of timber flat on both faces or of veneered particle board medium density wood particle board with commercial face , veneered supplied and fixed to chawkets complete.
S & F 2nd class HW 35mm thick glazed and skeleton shutters open rebated and prepared to receive glass gauge etc (w/o sash bars) complete all as specified.
S&F factory made solid panel PVC door shutter with MS square tube 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC sheet stirip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top,lock and bottom rail on either side & as gap insert for top rail & bottom rail .panelling of plain colour PVC sheet to be fitted in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement S&F in the steel frame at site as per specification.
S&F Steel ventilators with top hung shutter including hinges, steel peg stay complete.
S&F for steel window( Box Type windows )with side hung shutter including box type hinges with steel handle of MS flat 25x5mm and 2nos tower bolt of 100mm long fixed to shutter complete with glazing bar dovtailed or welded including one shop coat of primer complete all as specified.
All as per item No 71 above but without glazing bars.
M&L for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0
S&F for 3mm thick sheet glass, ordinary quality and glazing with oil putty in squares n. exc 0.5 Sqm in each pane complete all as specified.
S&F 4 mm thick figured glass and glazing with oil putty in squares not exceeding 0.5 sqm each pane.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
S&F wash hand basin vitreous china size 550x400mm white flat back includingbrackets as approved by GE ,waste,chain plug,pvc connection, pvc waste pipe complete all as specified.
S&F Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including all fixing acessoroies nuts washers etc .complete all as specified.
Flush pipe/ waste pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern/Wash Hand Basin/Urinal etc.
S&F in repairs Pillar taps, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed
S&F in repair , 15 mm bib taps, cast copper alloy chromium plated fancy type long body with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
S&F in repair , 15mm stop Angle valve s, cast copper alloy chromium plated fancy type with long shank and cup (concealed type) with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F in repair , 15mm bore stop cock chromium plated fancy type with long shank and cup (concealed type) with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F in repair , 15 mm bore chromium plate shower rose with or without swivel joint of size125mm incl fixing to pipe comolete all as specified and directed.
S&F PVC low level flushing cistern 10 litres capacity with long bend, white, with all fitting and fixtures including brackets and 32 mm bore PVC flush pipe, complete.
S&F PVC connection 15mm bore 450 mm long with brass nuts.
S & F GI tubing 15mm dia medium grade with all fittings and fixed to wall, floor and ceiling etc complete all as specified.
S & F for GI tubing 20mm dia medium grade with all fittings and fixed to wall, floor and ceiling etc complete all as specified.
S & F for GI tubing 25mm dia medium grade with all fittings and fixed to wall, floor and ceiling etc complete all as specified.
Fixing only of old steel GI tubing, 20mm bore and connections in new or old position (walls, ceiling, floors etc) complete all as specified.
S&F in repairs rotational moulded polyethylene water storage tanks of capacity 1000 litres, (cylindrical vertical tanks with closed top) ,three layered ISI marked/equilant in specifications ,hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified and as directed by Engineer-in-Charge
S&F ball valve of PTMT high pressure with polythene float and complete 20 mm bore for iron pipe or brass and fixed.
S & F 100 mm dia Cast Iron soil waste & vent pipes in any length with or without ears, with cement joints laid in trenches or in floors.
S & F in repairs 100 mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified.
S & F in repairs 100 mm dia branch piece single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door all as specified.
S&F in repairs 75mm dia CI soil waste and vent pipe in any length , sand cast pipe with or without ears laid in floors or in trenches all as specified.
S & F in repairs 75mm dia CI bends (any radius) with duck's foot or heel rest with cement joint and fixed .
S & F in repairs 75 dia branch piece single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door all as specified.
S & F for cast iron vent cowls 75mm dia complete all as specified.
S & F for PVC (SWR) 110 mm dia single socket in any length with rubber ring joints fixed to wall incl SS clamp complete all as specified.
PVC (SWR) bends any radius 110mm.
S & F in repairs, stop valve cast copper alloy with crutch or butter fly handle screwed both ends & screwed for iron pipe of 20mm dia complete all as specified.
S&F Gun metal gate valve with iron wheel head screwed down both ends for iron pipe and fixed to 20 mm bore pipe.
S&F Gun metal gate valve with iron wheel head screwed down both ends for iron pipe and fixed to 25 mm bore pipe.
M&L for Cast iron floor trap, 100/75mm incl CP grating.with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) .
S&F in repairs brass chromium plated tubular towel rail 20mm dia and 600mm long complete all as specified and directed
S&F mild steel sliding door bolt plate type stove enameled black with bright bolt not less than 12mm dia with and incl. A minimum of 6bolts and nuts four on bolt plate and two on staple plate of 250mm long.
S&F in repairs 300mm, ordinary rat tail rod pattern springs incl. roller and roller plate complete
S&F Aluminium anodised barrel tower bolts of extruded section, 200 mm long complete.
S&F Butt hinges, 100mm medium weight, cold rolled mild steel, and fixed
S&F Extruded aluminium alloy handles, fabricated type, anodised, 150 mm size complete.
S&F 20mm dia curtain rod mild steel chromomium plated incl brackets fitted in position.
S&F Butt hinges, 75mm medium weight, cold rolled mild steel, and fixed
M & L for preparing new plastered or surfaces of walls and applying two coats of distemper oil emulsion, white or tinted over & incl a coat of primer over & incl 3mm thick Birla white putty complete all as specified.
M&L for preparation to new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for Preparing new or previously untreated surfaces of wood and wood based materials of any decription exceeding 10 cm in width or girth when un-connected with other painting or when painted in different tint and applying two coats of synthetic enamel paint over & including a coat of pink primer.
M&L for Preparing old treated surfaces of wood and wood based materials of any decription exceeding 10 cm in width or girth when unconnected with other painting or when painted in different tint and applying one coats of synthetic enamel paint complete all as specified and directed.
M & L for preparation of new steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specied and directed.
M&L for preparation of steel old surfaces of any description over 10cm in width or girth and applying one coats of synthetic enamel paint complete all as specied and directed.
M&L for preparation to new plastered surfaces of walls and applying two coats of cement based paint complete all as specified and directed.
S&F in repairs (1.00/1.25mm thickness of laths) steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type.
Fixing only in repairs steel rolling shutters any thickness gear operated type with bevel gear box and crank handle ball bearing, as specified including top cover, anchoring rod, hasp and staple and erected in position as indicated, complete: push pull or manual type .Note : this item includes all necessary greasing, oiling and smooth functioning of the shutter as per the complete satisfaction of Engineer in charge.
Supp,ly only safety lever locks mild steel with 4 levers for rolling shutters
Supply only ball bearing for rolling shutters
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade witj gey cement and pigments complete all as specified and as directed by the Engr-in-Charge. ( Note:- Pigment & pattern of tiles will be as approved by GE.)
Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete in Type C1 1:3:6 using 20mm graded stone aggregate set in cement Set in cement mortar 1:4
Taking down carefully existing unserviceable Copper/aluminum batten/surface conduit/concealed conduit point wiring (light, fan, bell/buzzer, socket or power) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, pendents, sockets, lamp holders, shades, fan regulators, light fittings, bells etc (including old MS sunken boxes) and removing the retrieved materials from dismantling including making good the disturbed surface of walls, floors, ceilings etc complete all as specified and as directed by the Engr-in-Charge.
Taking down of unserviceable DBs/switch fuses/changeover in sheet steel enclosure complete with MCBs/Fuse/grips any capacity and removing from site and making good disturbed surface of wall, floor etc. Taking after disconnecting all cable complete all as specified and as directed by the Engr-in-Charge.
Point wiring with stranded copper conductor cable, 1100 volts grade (ISI marked) PVC insulated and unsheathed of size 1.5 Sq mm single core in and including new non-metallic rigid PVC concealed conduit, not less than 20 mm dia, medium duty ISI marked, including conduit fittings such as tees, bends etc terminating in and including new sunken box covered with and including 3 mm thick bakelite laminated sheet top cover of approved make for one fan or light or exhaust fan or bell/buzzer point controlled by one switch including provision of 1.5 Sqmm PVC insulated unsheathed copper conductor cable, multi stranded as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 127 here-in-before but socket point on the same board with other switches complete as specifed as directed by Engineer - In - Charge
All as per item No 127 here-in-before but socket point on indpendent board complete as specifed as directed by Engineer - In - Charge
All as per item No 130 here-in-before but cable 2.5 Sqmm for 15 Amps switch socket outlet on independent board complete as specifed as directed by Engineer - In - Charge
S&F Switch piano flush type, Single pole 5 Amps, one way ISI marked, complete all as specified and as directed by Engineer-in-Charge
S&F Socket outlet 2 in 1, flush type, 3 pin, 5 Amps, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F Lamp holder insulated body with back plate for conduit/casing capping fittings complete all as specified and as directed by Engineer-in-Charge Make CG/Havells/Phillips.
S&F Ceiling rose PVC/poly carbonate insulated body three terminal ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F bulk head luminaries LED Type 9 W , complete all as specified and directed .Make C.G /surya / Bajaj/CG
S&F switch socket combination 5 in 1, 5/16 amp flush type fixed on laminated sheet top cover (laminated sheet top cover is including in point wiring).
S&F Decorative ultra slim linear LED lightening fixture, energy efficent 18 Watt complete all as specified and directed by engineer-in-charge.Make SYSKA/BAJAJ/PHILIPS/C.G/wipro
S&F Decorative ultra slim linear LED lightening fixture, energy efficent 10 Watt complete all as specified and directed by engineer-in-charge.Make SYSKA/BAJAJ/PHILIPS/C.G/wipro
S&F Sheet metal enclosure for distribution boards, suitable for fixing MCBs 240 volts with 200 Amps rated bus bar, SPN, 8 ways double door , supplied and fixed in repair, including making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge. Make : Legrand / Schneider / ABB/ Havells
S&F MCB suitable for 6 to 32 Amps, 240 Volt AC supply single pole and neutral with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make : Legrand / Schneider / ABB/ Havells
S&F MCB single pole, 240 volts of rating 6-32 Amps, breaking capacity of 10 KA complete all as specified and as directed by Engineer-in-Charge Make : Legrand / Schneider / ABB/ Havells
Supply and laying in replacement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.00 sq mm 2 core
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 mtr in depth for route of cable and getting out complete all as specified and as directed by the Engr-in-charge.
Returning, filling in soft/loose soil including spreading, leveling watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by the Engr-in-charge.
Removing of surplus soil to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
Protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class 'B' bricks complete all as specified and directed by Engr-in-charge.
Local tibba dry sand cushioning for protection of cable complete all as specified and as directed by Engineer-in-charge. Note Local approved tibba dry sand after removal of vegetations, grass and other deleterious substances shall be used for sand cushioning.
M & L GI tubing light grade for protection of cables with pole/ in ground of size 40mm dia complete all as specified and as directed by Engineer-in-Charge.
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to main switch board, testing on completion including GI pipe 20 mm dia light grade for watering and bringing the same upto 30 cm above normal ground level with plug at top including pipe fittings etc complete and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 3 SSR Part-I.
GS BUILDERS AND ENGINEERS
Beenu Co. Company
ALPHA ENGINEERING COMPANY
SUBHAM ENTERPRISES
durga construction company
M/S BUDHRAM BISHNOI
JAGDAMBA CONSTRUCTION COMPANY
NAIRA CONSTRUCTIONS AND MANAGEMENT SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .