| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹19.9 L+₹62,392 (3.23%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest bidder | |
| 3 | L3₹21.5 L+₹2.2 L (11.3%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest bidder | |
| 4 | L4₹22.0 L+₹2.7 L (13.8%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L4 | Rejected-Finance Being other than lowest bidder | |
| 5 | L5₹23.6 L+₹4.3 L (22.5%)Rejected-Finance FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | L5 | Rejected-Finance Being other than lowest bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Jun 2022, 6:00 pmClosed
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
REPAIR MAINT OF DG SET AND CONNECTED ACCESSORIES AT 257 TRANSIT CAMP AND ADJACENT AREA UNDER AOR OF AGE EM I OF GE 865 EWS
2022_MES_525026_1
865/EWS(NIT-49)/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹80,000
Yes
9 Jul 2022
20 May 2022
20 Jun 2022
20 May 2022
18 Jun 2022
4 Jun 2022
Amount
Checking, Inspection, maintanance and servicing complete including replacement of unserviceable spare parts of the DG set (comparising of Engine/ Alternator/ Control panel) of the following capacity for smoth functioning complete all as per manufacturers instructions and all as directed by Engineer-in-Charge A. (a) Checking of lubricating oil condition (b) Checking engine for oil, water leakage and correcting the same (c) Checking of all the nut bolts of engine and alternator (d) Checking of all belts and adjust the tenson properly (e) Cleaning of air filters (f) Checking and readjusting the valve clearance (g) Change of Oil/Fuel filters and engine oil if necessary (h) Checking of starter motor battery and charger (i) Checking of cooling system and fuel system (j) checking of all power cables and AVR connections and mounting bolt tightnees of alternator (k) checking the function of AVR genaral checks (l) Checking of control panel meters and gadgets functiong (m) Checking of all control and safety wirings B. (a) Checking of flexible coupling of engine and alternator (b) Cleaning of crank case ventilation pipe (c) Checking of injectors and fuel pump (d) Checking of alternator and carbon brushes of following capacity DG sets NOTE (1) Cost of Spares required will be paid and measured separately (2) Servicing/routine check up carried out through authorised service centre of manufacturer (4) Make of spare recommendation by auth service centre of manufacturer
1010 KVA DG Sets
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG Set
35 KVA DG set
M & L for changing /toping up of best quality of engine oil 20W40 type for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed . Make:-castrol/veedol/Valvoline.
S&F in replacement Oil filter element as per existing for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engineer-in-Charge. Make- Kirloskar/Mico/TVS
1010 KVA DG Sets
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG Set
35 KVA DG set
S&F in replacement Air cleaner element (inner and outer) suitable for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engineer-in-Charge.
1010 KVA DG Sets
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG Set
35 KVA DG set
S&F in replacement Fuel filter elements(primary & secoundery) for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engineer-in-Charge.
1010 KVA DG Sets
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG Set
35 KVA DG set
S&F in replacement 'V' belt for water pump suitable for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engineer-in-Charge.
1010 KVA DG Sets
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG Set
35 KVA DG set
S&F in replacement fuel pipe with banjo bolt at both side suitable for following capacity DG sets make: Kirloskar/Cummins/Greaves complete all as specified and directed by Engineer-in-Charge.
1010 KVA DG Sets
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG Set
35 KVA DG set
S&F in replacement of Dynamo Assy for following capacity DG Set Make Kirloskar/ cummins/Greavescomplete all as specified and directed by Engineer-in-Charge.
1010 KVA DG set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
S&F in replacement of auotmatic voltage regulator (AVR) 24 volt suitable for following capacity of DG Set. Cat Part No F680902000 Make -Kirloskar or equivalent in Cummins/ Greaves
1010 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
S&F in Replacement of self starter for following capacity DG Set Make Kirloskar/ cummins/Greaves complete all as specified and directed by Engineer-in-Charge.
1010 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
S&F in replacement water pump assembly for following capacity DG sets make : Kirloskar/Cummins/Greaves complete all as specified and directed by Engineer-in-Charge.
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG set
S&F in replacement Turbo charger assy.for following capacity DG sets make Kirloskar/ cummins/Greaves complete all as specified and directed by Engineer-in-Charge.
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG set
S&F in replacement Fan Hub assembely for following capacity DG set make cummins/Kirloskar/Greaves complete all as specified and directed by Engineer-in-Charge.
1010 KVA DG Sets
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG Set
35 KVA DG set
M&L for disconnecting the U/S DC alternator of following capacity DG Set, 3 phase of approved make & type from engine, transporting to workshop dismantling it for repairing and rewinding by taking out burnt armature winding aleaning the alternator coil with existing gauge/size of super enamelled copper winding wire, providing new insulation, sleeves, varnishing cotton taping etc reassembling the alternator complete including aligning with engine and testing in all aspects for smooth functioning all as specified and directed by Engineer-in-charge. Note : Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding, aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engineer-in-Charge.
1010 KVA DG set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG set
M&L for taking out burnt winding of exciter of following capaicity of DG sets including re-winding copper wire of super quality, of existing size, No of turns, varnishing, heating complete including testing on full load complete all as specified and directed by Engineer-in-charge.
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG set
Note : Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding, aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engineer-in-Charge.
S&F in Replacement of lub oil pump suitable for following Capacity DG Sets, make: Kirloskar/Cummins/Greaves complete all as specified and directed by Engineer-in-Charge.
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG set
S&F in Replacement of thermostate valve suitable for following Capacity DG Sets make Kirloskar/ cummins/Greaves complete all as specified and directed by Engineer-in-Charge.
1010 KVA DG Sets
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG Set
35 KVA DG set
S&F in Replacement of Oil seal front and rearsuitable side for following Capacity DG Sets make Kirloskar/ cummins/Greaves complete all as specified and directed by Engineer-in-Charge.
1010 KVA DG Sets
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG Set
35 KVA DG set
S&F in Replacement Battery 12 Volt 180 AH (Maint free heavy duty with initial charging.Make- Exide/Amaron/ Luminous all as specified and directed by Engineer-in-Charge
M &L for Removing the fuel injection pump (FIP) & injectors from following capacity of DG sets and carry out servicing and calibration including replacement of injectors nozzles, etc. and refitting the same for smooth and efficient functioning all as directed by Engineer-in-Charge. Note :-Repairs will be carried out from authorised workshop of MICO or manufacturer of DG set.
1010 KVA DG Sets
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG Set
35 KVA DG set
M & L for dismantling the defective radiator assembly and taking it to contractor workshop for cleaning of radiator , finding the leakages by pressure method and providing leak proof treatment to defective radiator assemble by welding/brazing/glazing suitable material for cohesiveness for following capacity DG sets cleaning radiator by using K oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and Re-assembling after painting of the same complete all as specified and directed by Engineer-in-Charge.
1010 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG Set
35 KVA DG set
S&F in replacement of battery charger 12 Volt,10 Amp and making all electrical connection testing complete all as directed
S&F in replacement of battery charger 24 Volt, 10 Amp and making all electrical connection testing complete all as directed
S&F in Replacement of broken door hinges/handles of acoustic enclosure of 1010 KVA DG Set complete with manufacturer recommended handles/hinges using nut bolts etc as per site requirement of any type and make of DG set all as directed at site.
S&F in Replacement of broken door hinges/handles of acoustic enclosure of 250 KVA DG Set complete with manufacturer recommended handles/hinges using nut bolts etc as per site requirement of any type and make of DG set all as directed at site.
Materials and labour for scraping removing and cleaning old rusty paint from body of DG set of following capacity any make by cleaning agents & painting the DG set complete with Polyurethane (PU) paint as specified and directed at site by Engineer-in-Charge.
1010 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
Taking down old rusted unserviceable silencer single/double with exhaust pipe and M&L for new silencer with Exhaust pipe complete bends, coupling etc suitable for following capacity of DG set including fixing arrangements and painting with silver paint and insulating with suitable size and length of asbestos rope complete all as specified and directed by Engineer-in-Charge.
1010 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
S&F in replacement on Load change over switch (front handle) 415 volt in sheet metal enclosure, 4 pole, 630 Amps capacity
S&F in replacement on Load change over switch (front handle) 415 volt in sheet metal enclosure, 4 pole, 400 Amps capacity
S&F in replacement Offload Changeover Switch- AC 21 (side handle) in sheet enclosure, 415V AC, 50 Hz, of capacity 320 AMP, TPN Havells cat part No : IHCFFE0320 or equivalent of Indo Asian/Standard complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Offload Changeover Switch- AC 21 (side handle) in sheet enclosure, 415V AC, 50 Hz, of capacity 400 AMP, TPN Havells cat part No : IHCFFE0400 or equivalent of Indo Asian/Standard complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Offload Changeover Switch- AC 21 (side handle) in sheet enclosure, 415V AC, 50 Hz, of capacity 630 AMP, TPN Havells cat part No : IHCFFE0630 or equivalent of Indo Asian/Standard complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Air pipe (Turbo to Radiator) for any capacity of DG Set
S&F in replacement of bty charging alternator (12 volt) with 2 wire system for any capacity of DG Set
S&F in replacement of Digital RPM meter with Hour meter for any capacity of DG Set
S&F in replacement Air cleaner assembly kit for 1010 KVA DG set
S&F in replacement Stainless steel, Grey colour anti-vibration support pads for isolating the DG Set engine and alternator from the mounting frame having weighing capacity upto 400 Kgs each for suitable capacity of DG set complete all as specified and directed by Engineer-in-Charge.
S&F in Replacement of battry terminal for DG Sets complete all as specified and directed by Engineer-in-Charge.
S&F in replacement battery cable assy. with copper conductor multistranded RED and BLACK colour 2mtr long 21sqmm for connection to self starter unit to Battery unit complete.
Supply & toping up of best quality anti freezing,Inhabitor Corrosion (Coolant) liquid for DG set at varrious capacity and locations complete all as specified and directed. Make-castrol/veedol/Valvoline.
M & L for changing /toping up of best quality of engine oil 15W40 type for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed . Make:-castrol/veedol/Valvoline.
Note : Make of spare parts to be replaced under this work and mentioned in relevant items in this BOQ here-in-before shall be of approved make and as per the manufacturer's recommendation of DG sets and other equipments.
Mangalam Trades
HEENA CONSTRUCTION CO
national engineering
VEDA INFRASTRUCTURE
PADMA ENTERPRISES
M/S TRADE LINK
Horizon Construction Company
SUMEET TRADING CORPORATION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .