| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC 145 SAINIK NAGAR RAIBARELLI ROAD TELIBAGH LUCKNOW | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.9 L+₹1.5 L (5.58%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹28.9 L+₹1.6 L (5.83%)Rejected-Finance 58 SHAHEED NAGAR OPP BHIMRAO AMBEDEKAR UNIVERSITY RBL ROAD LUCKNOW 226025 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226025 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹29.8 L+₹2.4 L (8.77%)Rejected-Finance 93 SARASWATI PURAM COLONY SG PGI LUCKNOW UP 226 014 | LUCKNOW | LUCKNOW | UP | 226014 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹29.9 L+₹2.5 L (9.25%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
27 Jul 2022, 6:00 pmClosed
GE West Lucknow
GE West Lucknow, 11 Sardar Patel Marg, Lucknow Cantt-226002
REPAIR TO ROOF TREATMENT AND LEAKAGE/SEEPAGE IN ZONE A AREA OF AGE B/R I UNDER GE (WEST) LUCKNOW
2022_MES_534681_1
GE/W/LKO/38 OF 2022-23
Open Tender
Civil Works
Item Rate
270 days
Lucknow
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE West Lucknow
₹80,000
Yes
25 Aug 2022
29 Jun 2022
29 Jul 2022
29 Jun 2022
27 Jul 2022
13 Jul 2022
29 Jun 2022 - 6 Jul 2022
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc. 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for provn of roof treatment with polymeric water proofing membrane all as given below:- (a) Taking down existing water proofing treatment and cleaning of roof surface by washing and rubbing etc. and removing the retrieved material to a distance not exceeding 500m where directed. (b) Applying a coat of bituminous primer conforming to IS: 3384-1986 @ 0.25 Iit/sqm on prepared surface and allowed to dry. (c) Applying and laying 3mm thick APP membrane having non woven polyester matt at core and covered with high quality polymeric asphaltic protected thermo fusible HMHDPE film on both sides with over laps 10cm and 15cm at longitudinal and transverse direction respectively and sealed by flame, sealing all overlaps complete including treatment at all junctions and corners. The membrane shall be torched into groove on vertical plane and groove sealed with cement mortar 1:3. (d) M&L for applying two coats of aluminium paint on membrane @ 0.10 Kg/Sqm (each coat) complete all as specified and directed. Note:- (i) PCC padding or rendering for leveling of undulations on roof shall be measured and paid separately (ii) For filling undulation or levelling either PCC or rendering shall only be allowed for payment purpose.
M&L for provn of roof treatment with polymeric water proofing membrane all as given below:- (a) Taking down existing water proofing treatment and cleaning of roof surface by washing and rubbing etc. and removing the retrieved material to a distance not exceeding 500m where directed. (b) Applying a coat of bituminous primer conforming to IS: 3384-1986 @ 0.25 Iit/sqm on prepared surface and allowed to dry. (c) Applying and laying 3mm thick APP membrane having non woven polyester matt at core and covered with high quality polymeric asphaltic protected thermo fusible HMHDPE film on both sides with over laps 10cm and 15cm at longitudinal and transverse direction respectively and sealed by flame, sealing all overlaps complete including treatment at all junctions and corners. The membrane shall be torched into groove on vertical plane and groove sealed with cement mortar 1:3. (d) M&L for machine pressed chequered cement concrete tiles of size 250x250x20mm thick, set, jointed and pointed in neat cement slurry over and including 15mm thick screed in CM 1:4 complete all as specified and directed. Note:- (i) PCC padding or rendering for leveling of undulations on roof shall be measured and paid separately (ii) For filling undulation or levelling either PCC or rendering shall only be allowed for payment purpose.
M&L for provn of roof treatment with polymeric water proofing membrane all as given below:- (a) Preparation of old AC/Manglore tiles roof surfaces including cleaning of roof surface by washing and rubbing etc. and removing the retrieved material to a distance not exceeding 500m where directed. (b) Applying a coat of Bitumen, blown type, 85/25 grade on prepared surface of AC/Mangalore pattern roof . (c) Applying and laying 2 mm thick APP membrane having non woven polyester matt at core and covered with high quality polymeric asphaltic protected thermo fusible HMHDPE film on both sides with over laps 10cm and 15cm at longitudinal and transverse direction respectively and sealed by flame, sealing all overlaps complete including treatment at all junctions and corners. The membrane shall be torched into groove on vertical plane and groove sealed with cement mortar 1:3. (d) M&L for applying two coats of aluminium paint on membrane @ 0.10 Kg/Sqm (each coat) complete all as specified and directed.
M&L 10mm thick rendering in CM 1:4 using 100% coarse sand over roof slab, finished surface even and smooth without using extra cement and mixed with 3% integral water proofing compound complete all as specified and directed. NOTE: (i) WPC shall measured and paid seperately.. (ii) Wherever screed bed is provided, PCC padding shall not be provided.
M&L for plain cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate and mixed with 3% integral water proofing compound as in padding over roof slab, finished surface even and smooth without using extra cement complete all as specified and directed. NOTE: (i) WPC shall measured and paid seperately.
Supply only integral water proofing compound conforming to IS 2645 complete all as specified and directed.
M&L for repairing of cracks by cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
M&L for cleaning the exposed concrete surface of floor/ wall/ chajja by brushing & watering and applying one coat of TAPECRETE P-151 Acrylic Polymer Modified Cementitious slurry consisting 1:2 (1 part of tapecrete : 2 parts of cement by weight) and shall be allowed to dry for 4-6 hours, then applying second coat of 1.5mm thick tapecrete brush topping consisting 1:2:2 (1 part of tapecrete : 2 parts of cement : 2 parts of silica sand by weight) over the first coat and cured for next 2 days complete all as specified and directed.
M&L for cleaning and removal of vegetation plant of girth not exc. 20cm with roots from the roof surface and making good to disturbed surface in CM 1:4 or PCC 1:2:4 type B-0 as required at site including removal of same material to a distance not exc. 50m complete all as specified and directed. NOTE: The work shall be executed up to 12.50m height of bldg with all safety measures and no extra payment shall be paid to contractor on this account.
M&L Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other bands, plinth courses, string cources, lacing cources, parapets and railing upto 60cm in hight, copings, kneelers, apex stones, bed plates, water troughs, hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed.
Demolition and breaking up or taking down PVC/AC/CI/SSW 100mm bore pipe drain pipes, set in cement mortar including PCC haunching and bedding, complete.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls with PVC clamp complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls with PVC clamp complete all as specified and directed.
S&F PVC (SWR) bends of any radius, suitable for 110mm bore PVC pipes, fixed and jointed with solvent complete all as specified and directed.
S&F PVC (SWR) bends of any radius, suitable for 75mm bore PVC pipes, fixed and jointed with solvent complete all as specified and directed.
S&F PVC (SWR) junction single, (single T), equal or unequal suitable for 110mm bore PVC pipes, fixed and jointed with solvent complete all as specified and directed.
S&F in repair PVC (SWR) floor trap, plain with gratings including jointing with solvent cement, suitable for 75mm bore PVC pipes complete all as specified and directed.
S&F PVC (SWR) vent cowls suitable for 100mm bore pipes complete all as specified and directed.
S&F mild steel work as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintel hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290, Gde E-165 complete all as specified and directed.
M&L for cleaning all around at the mouth of existing rain water pipe properly at terrace, wetting and grouting with CM 1:4 and mixed with 3% water proofing compound, area of each grouting not exc. 0.10 sqm complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M & L brickwork with fly ash bricks, old size bricks straight or curved on plan exc 6m mean radius, built in, built in CM (1:6) , complete all as specified and directed.
M & L for Brickwork with fly ash old size bricks, straight or curved on plan to any radius in half brick thick walls, built in, in CM 1:4, complete, all as specified and directed.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair face of brick work of walls, finished even & smooth without using extra cement, all as per directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair face of brick work of walls, , finished even & smooth without using extra cement complete all as specified.
M&L for rendering 5 mm thick in cement mortar 1:3 on fair face of brick/concrete surfaces of ceiling, , finished even & smooth without using extra cement complete including all as directed.all as specified.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer complete all as specified & directed.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint over a coat of primer complete all as specified.
M&L preparation of new surfaces of of ceiling and applying three coat of white wash on ceiling complete all as specified and directed.
S&F in repairs 'E' board 600 x 600 x 4mm thick white, prelaminated sett embossed reinforced designer ceiling board tiles of approved texture at all height laid on hot dipped GI imposed grid with 24mm wide T sec exposed flanges which shall be pestered coated white. The frame work shall comprise of main runner made from 0.33 mm thick GI sheet of size 24x32x300mm and spaced at 1200 mm C/C securely fixed to be structural soffits by approved hangers at 1200mm C/C. Hanger of GI wire 4 mm dia to be fixed by approved recoil plug, screw etc. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall. flash fitting of 1200 mm long cross tec (with double sticking) to be interlocked bet wean main runner at 0600 mm centre from 1200x600 mm to modules cross tec longer than 600 mm to be supported independency 600x600 mm do duels to be formed by filling 600 mm long cross tec centrally between the 1200 mm cross tec. Tec perimeter wall angle shall be of 0.45 mm thick GS sheet of size 19x19 mm and 300 mm long of white colour all as per manufacture instruction complete all as specified and directed.
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors. Including taking up or down steel water tubing and connections of 15mm bore, fixed in walls, ceiling, floors, trenches etc. complete all as specified and directed
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors. Including taking up or down steel water tubing and connections of 20mm bore, fixed in walls, ceiling, floors, trenches etc.complete all as specified and directed
Dismantling PVC water tanks and removing for capacity exceeding 250 litres & not exceeding 500 litres etc., all as directed.
Dismantling PVC water tanks and removing for capacity exceeding 500 litres & not exceeding 1000 litres etc.,complete all as specified and directed
S&F 500 litre capacity Rotational moulded polyethylene water storage tanks triple layered (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc.complete all as specified and directed
S&F 1000 litre capacity Rotational moulded polyethylene water storage tanks triple layered (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.exc 250 Ltr but not exc 500 ltr in capacity Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc and writing date of cleaning using synthetic enamel paintcomplete all as specified and directed
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.exc 500 ltr but not exc 1000 ltr in capacityCleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc and writing date of cleaning using synthetic enamel paintcomplete all as specified and directed
S&F 15 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified and directed
S&F 20 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified and directed
S&F in repair 15 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified and directed
S&F in repair 20 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified and directed
Supply and fixing in repairs PVC connections 450mm long, 15 mm size with PTMT nuts at ends complete fixed in repair complete all as specified and directed.
Supply and fixing in repairs PVC connections 600mm long, 15 mm size with PTMT nuts at ends complete fixed in repair complete all as specified and directed.
S & F in repair hand shower (health faucet) with 1 m long flexible tube suitable for hot and cold water supply including wall hook, bracket etc complete set of superior quality complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semicorrugated, etc) sheets in roof coverings complete all as specified and directed.
S&F for 0.50 mm thick pre-painted galvalume aluminium zinc alloy coated steel (550 Mpa) corrugated sheet of any colour, double ribbed trapezoidal profile in desired length etc, as in roof covering/cladding to wall, with joints overlapped and fastened with fasteners using hot dipped zinc coated self drilling hexagonal washer head fasteners complete all as specified and directed.
S&F 6mm thick non asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc fixed with L type or J type or cranck hook complete all as directed.
S&F in repair for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated), Fe - 410- W(Gde - E 250 quality B) complete all as specified and directed
M & L for preparing new steel & iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified.and directed.
M/S SWATI CONSTRUCTION
M/S S S A ASSOCIATES
M/S Reliance Construction
M/S S&R Construction
Spectrum Enterprises
PARAMOUNT ENGINEERS
VINAYAKA (INDIA) MULTIFARIOUS SERVICES PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .