| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC | L1 | Accepted-AOC L1 bidder is techno commercially qualified. | |
| 2 | Rejected-Technical 159 KASIYADIH TANDWA CHATRA CHATRA JHARKHAND 825321 | CHATRA | JHARKHAND | 825321 | - | Rejected-Technical Bid not be opened as per NIT terms | |
| 3 | Rejected-Technical GUNJARDIH BHANDARIDAH BOKARO JHARKHAND PIN NO 829132 | BOKARO | JHARKHAND | 829132 | - | Rejected-Technical Bid not be opened as per NIT terms |
Tender Value
₹6.7 L
EMD Value
₹8,400
Closing Date
28 Sept 2024, 9:00 amClosed
Staff Officer (EnM)
Office of the General Manager, Dhori Area
Replacement of old and damage service cable for old air conditioner and providing service cable for newly supplied air conditioner installed at Ladies club, Dining hall and 7th Hostel at G M Unit, Dhori Area.
2024_CCL_317543_4
GM(D)/SO(EnM)/DA/2024-25/35
Open Tender
Electrical and Maintenance Works
Item Wise
15 days
GM Unit, Dhori Area
Please refer Tender documents.
2 documents required · 2 mandatory
₹8,400
9 Oct 2024
16 Sept 2024
30 Sept 2024
17 Sept 2024
28 Sept 2024
17 Sept 2024
17 Sept 2024 - 20 Sept 2024
Amount
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2 x 16 sq. mm + 1 x 6 sq.mm earth wire.
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2 x 10 sq. mm + 1 x 6 sq. mm earth wire.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 2 x 4 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including conduit as required. 40 mm
Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6 mm thick sheet steel enclosure duly painted with powder coating on existing rising main complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. 400 amps TPN
Replacement & Re-fixing of A.C. Box.
Supply and fixing of distribution Box 100 amp, 440 volt.
Total impact of GST for the purpose of CTC
ARJUN ENTERPRISES
MAHTO ENTERPRISES
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .