| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC JOGESHWARI W 758 ADARS NEW LINK ROAD 758 ADARS MUMBAI 400101 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400101 | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹24.5 L+₹5.0 L (25.8%)Rejected-Finance | L2 | Rejected-Finance Other than L1 |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
27 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR Pin-273008
IMPROVEMENT UP GRADATION OF BAR IN OFFICERS MESS PROVISION OF PATH IN FRONT OF OFFICERS MESS AND MD ACCN AT VIJAY VIHAR AT AIR FORCE STATION GORAKHPUR
2021_MES_434025_1
8782/E8
Open Tender
Civil Works
Item Rate
120 days
GE(AF) GORAKHPUR
As per Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE(AF) GORAKHPUR
₹38,000
Yes
4 Jun 2021
1 Apr 2021
28 Apr 2021
1 Apr 2021
27 Apr 2021
15 Apr 2021
60 days
Amount
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling or mass or sub base of floor concrete complete all as specified and directed.
Demolition of brick work built in cement mortar and removal of rubbish from site complete all as specified and directed.
M&L for brick work with sub class B bricks of old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
Cutting holes into or through brick walls built in cement mortar for inserting hold fast and making good in CM 1:3 or cement concrete 1:2:4 type B1 as required n.exc 150sqcm superficial area complete all as specified and directed.
S&F mild steel framed work such as grills, gratings, fillets etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, doors or gates, ladders, framed balusters, walk ways, railings, frame work of water tanks etc ant type of work conforming to Fe 290, grade E-165 complete all as specified and directed.
S&F welded steel wire fabric not exc 4 kg/ sqm weight welded to steel members complete all as specified and directed.
Taking down cement or cement lime plaster any description on brick or stone walls, etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified as directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces of wall, finished surface even and smooth without using extra cement complete all as specified as directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces of wall, finished surface even and smooth without using extra cement complete all as specified as directed.
M&L for complete removal of existing treatment on wall surfaces and applying a coat of primer over a coat of 1mm thick Birla putty as base coat to achieve smooth surfaces complete all as specified and directed.
M&L for preparation new/old surface of wall and applying two coat of plastic paint complete all as specified and directed.
M&L for preparation of new plastered surface of external walls and painting two coat of Ist quality of exterior emulsion exterior paint APEX ULTIMA or equivalent of approved make over a coat of primer complete all as specified and as directed.
M&L for complete removal of existing treatment and preparation of wall surface of external walls and painting two coat of Ist quality of exterior emulsion exterior paint APEX ULTIMA or equivalent of approved make over a coat of primer complete all as specified and as directed.
M&L for preparation of old painted wooden surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted steel surface of any description, over 10cm width or girth and apply one coat of synthetic enamel paint complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for vitrified double charged digital tiles 10mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but n.exc 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
All as per item No. 20 above but as in skirting including 10mm thick rendering screed in CM 1:4.
M&L for glazed ceramic tiles in vertical surface of size 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile over screed bed 10 mm thick in CM 1:4 complete all as specified and directed.
M&L for granite (of any type) 18 to 20mm thick machine cut and polished bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid over & including 20mm thick screed bed in CM 1:6 etc complete all as specified as directed.
Demolition of cement concrete un-reinforced in ground floors and paving not exc 15 cm thickness below or above ground level complete all as specified and as directed.
M&L for 100mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in floor, surface finished fair and even complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mt centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and directed.
Taking down chawkhats or frame with shutter (without taking out shutter from the frame exc 1.50 sqm and n.exc 4 sqm each and removing from site complete all as specified and directed.
Taking down shutter of any description n.exc 1 sqm each and removing from site complete all as specified and directed
M&L for powder coated anodised aluminium doors (sliding/ hanging type) with frame size 101.60x44.45x2.00mm thick and shutter aluminium anodised and top rail 47.62x44.45x 1.50mm and style 47.5x44.5x1.5mm, lock rail 83.50x44.45x1.50 mm and bottom rail 150.00x44.50x2.50mm including necessary aluminium fittings like aluminium butt hinges 04 Nos, aluminium handles 150mm 02 Nos, aluminium tower bolts 200mm 01No, mortice lock 4 lever MS, hydraulic door closer of suitable capacity 01 No, aluminium door stopper 01 Nos, jointing cleats, glazing cleats, rubber packing , anodised aluminium shape beading, screws etc with paneling in two parts with 12mm thick prelaminated particle board in lower panel and 5mm thick tinted glass in upper panels incl all fittings& fixture complete all as specified and directed.
M&L powder coated anodised aluminium (sliding/ hanging type) windows/ventilator with frame size 60x40x2.00mm thick and shutter with section bearing bottom 25x18x1.50mm, top 39.4x17.7x1.50mm (suitable for moving over three track fixed over top of frame work, top and side section of size 61.6x31.75 x1.5mm and bearing bottom track of size 61.6x31.75x1.5mm or fixing with hinges steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4 mm including necessary aluminium jointing cleats, glazing cleats, rubber packing anodised shape beading, screws etc with 4mm thick tinted/ plain glass in panels incl anodised aluminium grill with all fittings & fixture complete all as specified and directed.
M&L for powder coated anodised aluminium wall partition with anodised aluminium frame of section 101x44.45x2mm thick including necessary jointing cleats, glazing cleats, rubber packing, anodised aluminium shape beading, screws etc with paneling in two parts with 5mm thick tinted cloured glass including all fittings and fixtures complete all as specified and directed.
Dismantling plain or corrugated or semi corrugated asbestos/ steel sheeting, any gauge, thickness, roof covering complete all as specified as directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick (BMT) of any colour having tensile strength of 550 Mpa as in valley gutter, ridge of roof covering/ cladding to wall, fixing with self tapping screws complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise specifically provided for complete all as specified and directed.
S&F rolled mild steel section in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410-W (Gde E-250) quality-A complete all as specified and directed.
S&F mild steel plates, plain or chequered square cut or notched, ordinary and counter sunk, forming holes, without any attachment, complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Dismantling wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/slabs/ blankets, any thickness, including cover filets complete all as specified and directed.
M&L for non asbestos 4mm thick fiber cement building boards fixed or laid/inserted to aluminium frame work with screws as in false ceiling fixed in ceiling flat or sloping including aluminium anodised snap grid frame work of size 605x605mm for false ceiling with hanging arrangement of 6mm dia G .I. wire (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40x3 mm size and 60mm long and expansion hold fasteners 12.50mm dia 40mm long complete all as specified and directed.
S&F 5mm thick prelaminated solid PVC sheet in strips and channels feathered at the edges for fixing on solid PVC wall lining (panelling), insulated PVC wall lining inclusive of solvent cement and fixing at site on frames along walls complete all as specified and as directed.
S&F 10mm thick plain plaster of peris ceiling (Gypsum false ceiling to flat surface over 2nd class hard wood fillets, or metal frame work with GI wire mess paid separately) including sunk or raised moulding with POP and finishing complete all as specified and as directed.
All as per item No. 42 above but on curved surface.
S&F GI frame work including all necessary drilling, cutting to fix electrical items complete all as specified and directed with followings:- (a) GI sheet channel 30x25x20mm of 24 Gauge fixed with rawl plug and screws 450mm centre to centre along with perimeter of walls. (b) GI sheet channel made to shape 50x40x40mm of 24 gauge placed @ 600mm centre to centre from perimeter of wall except long wall (in one span) (c) GI sheet intermediate runners of size 45x10x10mm of 24 gauge fixed @ 1200mm centre to centre leaving frame of one side wall (in other span) (d) GI sheet 25mm wide & 20mm gauge suspenders fixed with steel fasteners to roof, ceiling @ 1200mm centre-to-centre incl plugging in RCC slab. (e) GI wire mess complete all as specified and as directed.
M&L for preparation new surface of ceiling and applying two coat of plastic emulsion paint over a coat of primer complete all as specified and directed.
M&L for preparation new/old surface of wall/ceiling and applying two coat of approved design of decorative texture paint by authorised agency complete all as specified and directed.
M&L for prefabricated, pre reinforced, 100 to 150mm wide POP moulded cornices/ moulding fixed on ceiling/ wall complete all as specified and directed.
S&F stainless steel of 304 grade for frame work for railing and similar decorative work complete all as specified and directed.
Surface excavation n.exc. 30 cm deep and averaging 15 cm deep and getting out etc in soft/loose soil complete all as specified and directed.
M&L for sand filling, spreading and levelling and well ramming including watering as required complete all as specified and directed.
M&L for machine rubber molded pressed pre-cast concrete cloured interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 grade set complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in copings, bed plate, roof kerbs or mud stops including weathering, slightly rounded or chamfered angles and throating with necessary form work complete all as specified and directed.
Taking down carefully copper/aluminium point wiring light/ fan/ bell/ socket or power complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc are to be measured separately) and/or drawing out from existing conduit/ batten and making good disturbed surfaces of walls/ floors/ ceilings complete all as specified and directed.
M&L for one light/fan point controlled by one switch point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 1.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken including provision for modular box including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete all as specified and directed.
All as per item No. 54 above but for one socket outlet 3/5 pin 5/6 amps independent controlled by one switch.
All as per item No. 54 above but for one socket outlet 3/5 pin 5/6 amps independent controlled by one switch on same board.
M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken for modular box including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent. Note for item Nos 54 to 57:- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. (ii) Sunken box, cover plate with frame, Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
S&F modular switch single pole 1 way, 1 module, 6 Amp complete all as specified and directed.
S&F modular switch single pole 1 way, 1 module, 16 Amp complete all as specified and directed.
S&F modular socket out let multipurpose 6A -2/3 pin, SP 1 way 2 module complete all as specified and directed.
S&F modular socket out let multipurpose 6A/16A-2/3 pin, SP 1 way 2 module complete all as specified and directed.
S&F ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed.
S&F modular white cover plate with frame 3 module complete all as specified and directed.
S&F modular white cover plate with frame 4 module complete all as specified and directed.
S&F modular white cover plate with frame 6 module complete all as specified and directed.
S&F modular metal flush box made of 1.6mm thick GI 3 module complete all as specified and directed.
S&F modular metal flush box made of 1.6mm thick GI 4 module complete all as specified and directed.
S&F modular metal flush box made of 1.6mm thick GI 6 module complete all as specified and directed.
S&F modular fan regulator 240 V electronic type 2 module complete all as specified and directed.
S&F in replacement recess mounting LED luminaire of size 2'x2' white 36 watt, 230 volts for POP ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- Havells Cat part No. PLUTONEO2X2PLR or equivalent in Bajaj /CG.
S&F in replacement 20 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No.LHEXBXPNIN1W020 or equivalent in Bajaj /CG.
S&F in replacement sheet metal enclosure (MCB DBs) single phase and neutral with 200 Amps rated bus bar 8 way double door type complete all as specified and directed.
S&F in replacement MCB, SP, 5 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F in replacement MCB, SPN, 32 to 40 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
M&L for replacement sub main wiring with 2 No single core PVC insulated unsheathed 6.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 4.0 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 6.0 sqmm conductor cable, 1 No 4.0 sqmm conductor earth continuity cable and accessories including chase cutting shall be measured as one unit length)
Taking down the existing ceiling fan, overhauling by necessary cleaning, oiling & greasing, making necessary adjustment and proper alignment of blades, hanging/fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of the department complete all as specified and directed.
M/s Aparna Associates
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .