Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹43.8 L+₹3.0 L (7.37%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹44.9 L+₹4.1 L (10.0%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
25 Dec 2024, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIR AND REPLACEMENT OF EXTERNAL WATER SUPPLY AND REPAIR OF PUMPS CH PLANT DG SETS SOLAR WATER HEATER MORTUARY CABINET WALKING COOLER TOWER AC AND OTHER MISC EM ITEMS AT MH BHOPAL UNDER GE BHOPAL
2024_MES_686265_1
8317/E8
Open Tender
Civil Works - Water Works
Item Rate
183 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹94,000
Yes
10 Feb 2025
29 Nov 2024
27 Dec 2024
29 Nov 2024
25 Dec 2024
13 Dec 2024
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation etc or for manholes, laying of pipe lines, cables, pipes etc in any type of soil and getting out complete all as specified and directed.
Returning filling in, including spreading, leveling watering & well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and diected.
Taking out existing CI/DI pipe line, of any class including CI fitting with spigot and socket ends and lead joints including burning out lead joints, recovering lead for re-use complete all as specified and directed for the following sizes :-
80mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 to 450 mm bore
Relaying CI pipe including fittings with spigot and socketed end/ flanged end, centrifugally cast laid in trenches after cleaning internally and externally, drawing out foreign material/ rust complete and jointing with and including new titon joints for fixing of pipe complete all as specified and directed for the following sizes:- Note :- (i) Earth work, joints and CI specials/fittings of the pipes shall be measured and paid separately under appropriate item.
80mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 to 450 mm bore
Supply, laying and jointing of DI iron pipes SS class K-9 of standard length with internal cement mortar coating and external surface with bituminious paint, ISI marked including nuts, bolts, packing material etc; and making the joint leak proof complete all as specified and directed for the following sizes:- Note : - Earth work, joint and CI/DI specials/fittings of the pipes shall be measured and paid separately under appropriate items of schedule.
100 mm bore
150 mm bore
200 mm bore
250 mm bore
S&F push on flexible rubber gasket (Tyton) joint suitablecomplete all as specified and directed for following sizes :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 to 450 mm bore
Cutting of cast iron pipes in position for insertion of new tees, branches, etc; comprising of two cuts complete all as specified and directed for the following sizes:-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 to 450 mm bore
S&F of CI/DI, bend (any type, radius and angle) tapers any type, straight bend including decreasing or double socket etc, Tee pieces single branch, 'Y' junction, all sockets or socket and spigot or flanged, collars, caps and plugs for spigot socketed pipes of upto 150 mm bore complete all as specified and directed.
S&F of CI/DI, bend (any type, radius and angle) tapers any type, (straight bend including decreasing or double socket etc) Tee pieces single branch, 'Y' junction, (all sockets or socket and spigot or flanged) collars, caps and plugs for spigot socketed pipes of 200 to 450 mm bore complete all as specified and directed.
S&F of DI, bends, tappers, straight connection piece, tee pieces, either one side flanged other socketed/ both flanged/ both socketed any type, radius for up to 450 mm bore including nuts, bolts, packing material etc; and making the joint leak proof complete all as specified and directed.
M&L for run lead joint for spigot and socketed end CI pipe & fittings including excavation, returning and refilling complete all as specified and directed for following:-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 to 450 mm bore
M&L for cocking of run lead joint for spigot and socketed pipes and fittings including excavation, returning & refilling etc complete all as specified and directed of following sizes:-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 to 450 mm bore
Taking out sluice valve top cover, repairing of unserviceable spindle and unserviceable check nut by grinding, machining and putting extra material with and including required lath work and refixing of sluice valve parts after servicing including replacment of gland packing, rubber sheet, nuts, bolts, check nut and washer of existing size complete all as specified and directed of following sizes:-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 to 450 mm bore
S&F in replacement new cast iron flanged sluice valve of class PN 1.0, long body, ISI marked, confirming to IS-14846 with stainless steel spindle and hand wheel including nuts, bolts, rubber gasket for installation of valve complete all as specified and directed of following sizes:-
80 mm dia
100 mm bore
150 mm bore
200 mm bore
250 mm bore
450 mm bore
M&L for framed work for made of angle iron, MS sheet as required including welding, cutting, providing hinges, locking arrangments including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for brick work with sub class B bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4 complete all as specified and directed.
M&L for PCC, 1:2:4, type B1 (using 20 mm graded stone aggregate) as in copping/ support and similar work including necessary form work etc complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work, finished even and smooth without using extra cement complete all as specified and directed.
Taking down existing steel tubing and connections with fittings complete all as specified and directed of following sizes:-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
Refixing retrived old steel tubing and connections in new or old position including cleaning internally and externally any grade/make, laid in trenches/ floor or fixed to walls with and including new fittings such as sockets, tee, union elbow etc complete all as specified and directed of follwing sizes:-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
S&F of GI tubing, medium grade, ISI Marked in any length including cutting, threading, making connection in new or old position with and including and all type of GI new fittings for laid in trenches/wall/floor complete all as specified and directed of following sizes:-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
S&F of 3 layer PP-R poly propylene random complymer concealed pipes (outer diameter of pipe) SDR 7.4 (PN-16) UV stablized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain brass threaded polypropylene random fittings fixed to walls, ceilings or laid in floors complete all as specified and directed of following sizes :-
15 mm outer dia
20 mm outer dia
25 mm outer dia
32 mm outer dia
S&F of 3 layer PP-R poly propylene random complymer concealed pipes (outer diameter of pipe) SDR 7.4 (PN-16) UV stablized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain brass threaded polypropylene random fittings laid in trenches complete all as specified and directed of following sizes:-
50 mm outer dia
63 mm outer dia
90 mm outer dia
Drilling and taping cast iron water mains (in position) for making branch connections complete all as specified and directed of following sizes:-
15 mm bore
20 mm bore
S&F in replacement gun metal globe or gate valves, confirming to IS: 778 with iron wheel head, screwed both ends for iron pipe and fixed in existing or new position complete all as specified and directed for following sizes:-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
S&F in replacement rubber gasket joint for spigot and socketed end CI pipe and fittings including necessary excavation, returning & refilling complete all as specified and directed for following sizes:-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 to 450 mm bore
M&L for providing joint with rubber or fibre board gasket for flanged pipes and fittings including necessary excavation, returning and refilling complete all as specified and directed for following sizes:-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 to 450 mm bore
S&F in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm bore (minimum weight 210 gms) complete all as specified and directed.
S&F in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 25 mm bore (minimum weight 455 gms) complete all as specified and directed.
S&F of replacement rotational moulded, three layer, polyethylene water storage tanks (cylindrical vertical with closed top) of 500 litres capacity, hoisted and fixed in position including connecting up pipes complete all as specified and directed.
S&F of replacement rotational moulded, three layer, polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, hoisted and fixed in position including connecting up pipes complete all as specified and directed.
Disconnecting existing water tanks of capacity upto and including 500 litres, setting aside or lowering if required for repairs including making it leak proof using M-Seal or other approved products, replacement of barrel nipple, cleaning, etc and hoisting, reconnecting and refixing in position complete all as specified and directed.
Disconnecting existing water tanks of capacity above 500 litres and upto 1000 ltrs, setting aside or lowering if required for repairs including making it leak proof using M-Seal or other approved products, replacement of barrel nipple, cleaning, etc and hoisting, reconnecting and refixing in position complete all as specified and directed.
S&F in replacement stainless steel splindle with check nut of gun metal gate valve as per existing shape & size, including opening, grinding, threading, machining of gun metal gate valve, replacement of nuts, bolts and washers including rubber gasket complete all as specified and directed for following sizes:-
M&L for painting to sump/ wall/ pipe etc in main filter pump house with two or more coats of synthetic enamel paint complete all specified and directed.
S&F for cast iron pipe 450 mm bore and fixed in position including connecting up pipes including taking down old pipe, any type and depositing to MES store complete all as specified and directed.
S&F in repiars new flange type non return valve of size 80 mm including nuts, bolts and all connecting accessories complete all as specified and directed.
S&F in repiars new flange type non return valve of size 100 mm including nuts, bolts and all connecting accessories complete all as specified and directed.
S&F in repiars new flange type non return valve of size 150 mm including nuts, bolts and all connecting accessories complete all as specified and directed.
S&F in repiars new flange type non return valve of size 200 mm including nuts, bolts and all connecting accessories complete all as specified and directed.
S&F in repairs new flange foot valve of size 80 mm including nuts, bolts and all connecting accessories complete all as specified and directed.
S&F in repairs new flange foot valve of size 100 mm including nuts, bolts and all connecting accessories complete all as specified and directed.
S&F in repairs new flange foot valve of size 150 mm including nuts, bolts and all connecting accessories complete all as specified and directed.
S&F in repairs new flange foot valve of size 200 mm including nuts, bolts and all connecting accessories complete all as specified and directed.
S&F in replacement new mechnical joints for DI type, K12 of followng size including nuts, bolts and all connecting accessories complete all specified and directed for following sizes:-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
450 mm bore
S&F PP-R poly propylene random complymer gate valve complete all as specified and directed of following sizes:-
20 mm bore
25 mm bore
32 mm bore
40 mm bore
50 mm bore
63 mm bore
S&F of air release valve as per IS: 14845, double chamber including nuts, bolts, rubber sheet complete all as specified and directed of following size:-.
Day to Day Maintenance of GI/CI/DI pipe line various sizes for minor reparing/rectified and attending the complaint of pipeline leakage/ float valve repairs by highly skilled tradesman as required at site to complete job with stuiplated time without hampering water supply and making supply functional including all necessary T&P complete all as specified and directed for following bores:- Note : - (i) The quoted rate deems to exclude for all excavation and dewatering. (ii) The tradesman shall report to E/M complaint cell of AGE E/M Bairagarh Bhopal daily at 8.30 am to take complaints from concern JE E/M. The complaint slip duly signed by the users shall be returned back at the complaint cell. (iii) Urgent complaint must be completed either in holiday or sunday. (iv) New GI fittings of suitable size, yarn and safeda/ white lead measured and paid separetally. (v) Complaint slips & other stationary required for attending complaint shall be supplied by contractor without any extra cost to the department.
15 mm dia
20 mm dia
25 mm dia.
40 mm dia.
50mm bore
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
450 mm bore
S&F of 25 mm GI socket complete alll as specified and directed.
S&F of 25 mm GI Elbow complete all as specified and directed.
S&F of 25 mm GI union complete all as specified and directed.
S&F of 25 mm GI Tee complete all as specified and directed.
S&F of GI reducer 25 x 20 mm complete all as specified and directed.
S&F of GI nipple 25 x 100 mm complete all as specified and directed.
S&F of 25 mm tank nipple complete all as specified and directed.
S&F of 20 mm GI Union complete all as specified and directed.
S&F of 20 mm GI Tee complete all as specified and directed.
S&F of GI reducer 15 x 20 mm complete all as specified and directed.
S&F of GI nipple 20 x 100 mm complete all as specified and directed.
S&F of 20 mm tank nipple complete all as specified and directed.
S&F of 15 mm GI union complete all as specified and directed.
S&F of 15 mm GI Tee complete all as specified and directed.
S&F of GI reducer 15 x 25 mm complete all as specified and directed.
S&F of GI nipple 15 x 100 mm complete all as specified and directed.
S&F of 15 mm tank nipple complete all as specified and directed.
S&F of 20 mm NRV complete all as specified and directed.
S&F of 25 mm NRV complete all as specified and directed.
S&F of 15 mm NRV complete all as specified and directed.
Supply of teflon tape packet complete all as specified and directed.
S&F of lead material complete all as specified and directed.
S&F of lead wool complete all as specified and directed.
Testing of collected water sample from NABL/ approved lab as per IS: 10500: 2012 at main filter Pump House Bairagrh complete all as specified and directed for the following parameters:-
Table 1: Organoleptic and physical parameters
Table 2: General parameters concerning subtancesundesirable in excessive amounts
Table 3: Parameters concering toxic substance
Table 4: Parameters concering radioactive substance
Table 5 Pesticide Residues limit and test method
Taking down of Solar water heating system of 200 ltrs per day capacity from its position after disconnecting water connections, and refixing /reassembling in position after repairs and testing complete all as specified and directed. Note:- (a) Rate quoted by the contractor deemed to be included making good of missing nuts, bolts, washers, screws etc to make it full functional. (b) Descalling/desludging, cleaning and washing of solar panels, hot water pipes, copper tubes, hot and cold water tanks by using appropriate chemicals and reassembling the panels including necessary welding of collector fins as required. (c) Painting to staging, solar panel frames, hot water tank frame with a coat of synthetic enamel paint including necessary preparation of surfaces complete. (d) Any other materials/parts need to be replaced by contractor and will be measured and paid seperately.
All as per item No. 74.00 here-in-before but of 100 ltrs per day capacity.
S&F in replacement of stainless steel water heater tank suitable for 100trs per day capacity to match with existing tank specifications with all fixing arrangements complete all as specified and directed Note: Sheet thickess of new tank to be matched with existing tank.
All as per item No. 76.00 here-in-before but 200 Litre per day capacity.
S&F of solar energy collector panel made of aluminium body with 5mm thick toughened glass complete with copper fins of capacity 200 ltrs per day to match with existing complete all as specified and directed.
S&F of Solar energy collector panel gasket made out of superior quality rubber to make system air tight, dust and water proof complete for 200 litres per day capacity complete all as specified and directed.
S&F of compressed glass wool (insulation materials) 48mm thick between solar energy collector panel, copper tubes frame and aluminium body panel including securing it on panel by means of necessary adhessive complete all as specified and directed.
S&F of solar energy collector panel manifold 1.40 mtr long, made out of 20mm dia copper tube having 1 No MS flange, 74mm dia welded at each end duly drilled for nuts, bolts and washers including welding of solar collector tubes with manifold complete all as specified and directed.
Supply and filling anti freezing liquid for solar water heater system in 20 ltrs PVC can complete all as specified and directed.
S&F in repairs 4 mm thick toughened glass of size as per sample in area exceeding 2 Sqm suitable for solar water heater rated panel of capacity 200 LPD complete all as specified and directed.
S&F in repairs bib taps of 15 mm dia bore, cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed iron pipe complete all as specified and as directed.
S&F stop valves of 15 mm dia bore, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends iron pipe or for unions complete all as specified and directed.
S&F stop valves of 20 mm dia bore, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends iron pipe or for unions complete all as specified and directed.
S&F stop valves of 25 mm dia bore, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends iron pipe or for unions complete all as specified and directed.
Labour only for repairing & comprehensive maintenance of DG sets of any make including replacement of worn out spares such as fuel filter, oil filter, lubricating oil hoses, V- belt, Oil pipes, fuel pipe, water pump, cut out and tightening of nuts, bolts, washers etc complete all as specified and directed of the following capacities:- (Note :- Replaced spare parts shall be mesured & paid separetely)
(a) 750 KVA capacity
(b) 62.5 KVA capacity
(c) 50 KVA capacity
(d) 20 KVA capacity
Periodical maintenance of DG set 750 KVA by authorised representative of manufacturer (OEM) by "B" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 750 KVA by authorised representative of manufacturer (OEM) by "C" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 750 KVA by authorised representative of manufacturer (OEM) by "D" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 62.5 KVA by authorised representative of manufacturer (OEM) of Engines complete all as specified and directed.
Supply only following spare parts for 750 KVA of Make:- Kirloskar / Greaves Crompton / Cummins / Mahindra complete all as specified and directed:-
(a) Head Gasket Kit complete
(b) Fuel Filter complete
(c) Lubricating Oil Filter complete
(d) Hose Pipe Set complete
Supply only following spare parts for 62.5 KVA of Make:- Kirloskar / Greaves Crompton / Cummins / Mahindra complete all as specified and directed:-
(a) Head Gasket Kit complete
(b) Fuel Filter complete
(c) Lubricating Oil Filter complete
(d) Hose Pipe Set complete
Supply only following spare parts for 50 KVA of Make:- Kirloskar / Greaves Crompton / Cummins / Mahindra complete all as specified and directed:-
(a) Head Gasket Kit complete
(b) Fuel Filter complete
(c) Lubricating Oil Filter complete
(d) Hose Pipe Set complete
Supply only following spare parts for 20 KVA of Make:- Kirloskar / Greaves Crompton / Cummins / Mahindra complete all as specified and directed:-
(a) Head Gasket Kit complete
(b) Fuel Filter complete
(c) Lubricating Oil Filter complete
(d) Hose Pipe Set complete
Dismantling and taking down radiator assembly from engine of any capacity for repairs including de-scalling, bracing as necessary to protect plug leakages with and including M&L for transporting the radiator of capacity 750 KVA for repair/maintenance to radiator fins, cleaning coil solution and radiator complete and repairing to the leakage places by means of gas welding and re-fixing after repairs including replacement of worn out nuts, bolts, washers, etc; and testing complete all as specified and directed.
Dismantling and removing fuel injection pump from DG set for repairs including re-calibration at authorised service centres, replacement of necessary spare parts such as delivery valves, plunger, 'O' ring and springs etc including refixing in position and testing complete all as specified and directed of the following capacity:-
(a) 750 KVA capacity
(b) 62.5 KVA capacity
(c) 50 KVA capacity
(d) 20 KVA capacity
Supply only Lubrication Oil, 15 W 40 or 20 W 40 complete all as specified and directed. Make :- Castrol / Servo /HP
M&L for repairing/ overhauling of self starter 12/ 24 Volts of any make/ capacity including replacement of minor spare parts such as carbon brushes, nuts, bolts etc. complete all as specified and directed. Note:- Any other spares as required will be measured and paid seperately.
Supply only the following spares for self starter 12 / 24 Volts complete all as specified and directed :-
(a) Field coil
(b) Armature
(c) Clutch assembly
Supply only battery cable, copper conductor 25 Sqmm, multi stranded, PVC insulated with suitable terminals at both ends complete all as specified and directed.
Supply only Fan belts as per sample for DG sets of capacity:-
(a) 750 KVA capacity
(b) 20 to 62.5 KVA capacity
Supply only water pump suitable for DG sets of following capacity:-
(a) 750 KVA capacity
(b) 20 to 62.5 KVA capacity
S&F in replacement Solenoid valve suitable for 750 KVA DG set complete all as specified and directed.
Supply only Coolant additive concentrate (Pack of 10 Ltrs) suitable for DG Set complete all as specified and directed.
Supply only Distilled water in 5 ltr PVC Container complete all as specified and directed.
Supply only air filter, outer & inner element suitable for 750 KVA DG set as per sample complete all as specified and directed.
Supply only air filter, outer & inner element suitable for 62.5 KVA DG set as per sample complete all as specified and directed.
Supply only air filter, outer & inner element suitable for 20 KVA DG set as per sample complete all as specified and directed.
S&F in replacement On load changeover switches, 4 pole, 200 Amps, manual changeover in open execution complete all as specified and directed.
S&F in replacement On load changeover switches, 4 pole, 100 Amps, manual changeover in open execution complete all as specified and directed.
S&F in replacement maintenance free lead acid battery 12 Volts, 180 AH with minimum 36 months warranty complete all as specified and directed.
S&F in replacement maintenance free lead acid battery 12 Volts, 92 AH with minimum 36 months warranty complete all as specified and directed.
M&L for servicing of DG Sets of any capacity of 20 to 62.5 KVA, Make : Kirloskar, Ruston & Commins at 250 running hours or 6 months whichever is earlier including replacement of defective/warn out parts by new spares such as filters, gaskets, V-Belts Engine oil, rubber hoses, worm drive, clamps, nuts & bolts, KIT complete all as specified and directed. Note:- New spare parts required will be measured and paid separetely in relavent items.
Supply only of the following in the repair for 20 to 62.5 KVA DG Set
(a) Element fuel filter
(b) Element oil filter
(c) Kit supper by pass filter Element
(d) Hose flexible
(e) Control Safety ( Water)
(f) Copping suitable for existing DG Set with Lubjoy rubber coppling
S&F in replacement Battery terminal heavy duty brass with nut & bolt complete all as specfied and directed.
Supply only Petrolium jelly in 1 Kg plastic sealed container complete all as specfied and directed.
S&F in replacement Battery cable for 180 AH, 12 V battery, 25 Sqmm copper conductor PVC multistranded 1.5 mtr long duly fixed with terminals and lugs complete all as specfied and directed.
S&F in replacement Battery link lead with battery terminal of +/- terminal 0.3 mtr long complete all as specfied and directed.
S&F in replacement Oil pressure gauge suitable for YDA series DG set complete all as specfied and directed.
S&F in replacement heat proof asbestos rope 12mm dia in engine exhaust pipe including minor welding / tightening in leakage exhaust complete all as specified and directed.
Calibration and over hauling FTP or PT pump of 10 KVA to 62.5 KVA DG set with and including replacement of the following parts :- (a) Delivery valve - 06 Nos (b) Bearing - 02 Nos (c) Elements - 06 Nos (d) Main spring - 06 Nos (e) Gasket sets (f) Seal (g) Cap Screw (h) 'O' ring - 01 set (j) Governer assembly - 01 set (k) Screen filter
Dismantling of unserviceable self starter of capacity 12/24 Volts from engine and shifting to civil workshop for repair / overhauling of the self starter by rewinding of one field coil as per existing, repair and rewinding of armature and re-fixing in existing position complete all as specified and directed.
Supply only Rubber Coupling for DG Sets upto 100 KVA to 750 KVA complete all as specified and directed.
M&L for tank cleaning of DG set of capacity from 10 to 100 KVA with appropriate solution complete all as specified and directed.
M&L for tank cleaning for DG set of capacity from 110 to 750 KVA with appropriate solution complete all as specified and directed.
Periodical maintenance (Quarterly basis) of Softener Plants as per the Thermax Norms suitable for IBR complaint steam boiler capable of generating steam 400 Kg per hour at 100 DC having reverse of fuel technology steam output at safety valve set pressure of 10.5 Kg per square centimetre, LDO/HSD operated fixed complete at MH Bhopal by OEM or Authorised Partner of OEM complete all as specified and directed.
Supply only salt for sofltner recharge complete all as specified and directed.
Repair/maintenance of UPS for 30 min back up three phase AC input 3 phase, 4 wire voltage range (V AC) 310 to 480 V, 55 HZ, phase out put 3 phase, 4 wire, battery voltage (V DC) 360 V, battery charging current 10 A, operating tempeature (celcius) 0 to 45 degree C, operating port RS-232 server and client, IP20 of DSP based double conversion online system with true galvanised isolation technology with out put power 8000 W and out put voltage 415 V ± 1% of capacity 7.5 to10. KVA including repair of mother board and S&F in replacement new battery as per site requirement and other minor spare parts if required to make it functional complete all as specified and directed.
S&F of air circuit breaker, 4 Pole, 415 Volts with manual drawout type with microprocessor release of capacity of 1250 Amps including all accessories complete all as specified and directed.
S&F of shock manual treatment chart written in English, Hindi complete all as specified and directed.
S&F in replacement of RCC factory made earthing pit chamber with cover of size 750 x 750 x 150 mm & 50 mm thick complete all as specified and directed.
Maintenance of Chlorine dosing system consisting of 40 ltrs to 100 ltrs HDPE/FRP tank with level gauge along with agitator with shaft and blade in plastic mounted tank lid with have prothole for pouring of altoch for mounting decrin dosing pump on the wall and decrin dosing pump Model 96-NGQ 51 high pressure single head gear motor adjustable dosing pump with accessories and suitable electrical connection of following specifications: Adjustable high pressure 0 to 100 PSI, power 230 Volts, 50 Hz, RPM-44, HP 1/30 fractional out put 2 US GPD to 40 US GPD located at various pump houses under GE Bhopal complete all as specified and directed. Note: Spare parts required for replacement required maintenance work will be measured & paid in relevent items.
Supply only of gear motor 230 volt 50 Hz suitable for decrin dosing pump as per existing complete all as specified and directed.
Supply only of rotor assembly with bearing brackets and tolerance rings as per existing complete all as specified and directed.
Supply only of Coil 250 volt, 50Hz as per existing complete all as specified and directed.
Supply only of Single head feed rate control with shaft as per existing complete all as specified and directed.
Supply only of pump head (Ferrules 1/4") including duckbill as per existing complete all as specified and directed.
Supply only of Roller assembly as per existing complete all as specified and directed.
Supply only of Pump tube as per existing complete all as specified and directed.
Supply only of Injection check valve 3/8" as per existing complete all as specified and directed.
Supply only of Weighted suction line strainer 3/8" as per existing complete all as specified and directed.
Supply only of White suction/discharge tube as per existing complete all as specified and directed.
Supply only of chloroscope for water testing range of 0.1 ppm to 2.0 ppm complete all as specified and directed.
Supply only of ORTO-TOLUDINE regent solution in 500 ml bottle complete all as specified and directed.
Supply only of first Aid kit (PVC container) including first aid medical treatment materials complete all as specified and directed.
Supply only of Knob of speed/stroke complete all as specified and directed.
Supply only of main indicator lamp assembly complete all as specified and directed.
Supply only of valve seat cap of suction/discharge complete all as specified and directed.
Supply only of fuse assembly including fuse complete all as specified and directed.
Supply only of anti syphon valves complete all as specified and directed.
Supply only of FRP construction solution preparations cum settling tank with level gauge, lid, inlet / outlet connection, drain connection and fitted with speed reducer, motor and SS agitator of capacity 100 Ltrs complete all as specified and directed.
M&L for serving/ repairing of Aqua Guard of capacity upto 15 Ltr/hr with and including replacement of complete filters and defective spare parts if required to make it functional complete all as specified and directed.
Periodical/Preventive maintenance as per recommended by (Quarterly basis) walk in cooler of make: Blue Star of size 8' x 8' x 8' for preserving life saving medicine and medical stores to maintain temperature range from 2 degree C to 8 degree C including dual air cooled split type cooling unit of capacity 1 TR/12000 BT U/Hr (one working and other standby) and repair of short circuit/damaged wiring, maintenance of cold room panel, front display controller, temperature control panel, servicing of Indoor/outdoor unit including gas charging complete all as specified and directed. Note:- (i) Maintenance will be carried through OEM only. (ii) Quoted rates are inclusive of oiling, greasing & minor spare parts as required for smooth funtioning of cooler.
Periodical/Preventive maintenance as per recommended by (Quarterly basis) walk in cooler of make: Blue Star of size 15' x 12' x 10' for preserving life saving medicine and medical stores to maintain temperature range from 2 degree C to 8 degree C including dual air cooled split type cooling unit of capacity 5 TR/60000 BT U/Hr (one working and other standby) and repair of short circuit/damaged wiring, maintenance of cold room panel, front display controller, temperature control panel, servicing of Indoor/outdoor unit including gas charging complete all as specified and directed. Note:- (i) Maintenance will be carried through OEM only. (ii) Quoted rates are inclusive of oiling, greasing & minor spare parts as required for smooth funtioning.
S&F in replacement of compressor for outdoor unit no 1 Model RUAHO6024CS / RUAHOP1514 complete all as specified and directed.
S&F in replacement of PCB componant as per existing complete all as specified and directed.
S&F in replacement of blower fan heavy duty of size 650mm sweep or as per site requirement complete all as specified and directed.
Periodical maintenance (Quarterly basis) of mortuary cabinate for two body of make: Blue star, 230 Volt, single phase, 50 Hz with roof mounted refrigeration system of capacity 6000 BTU/H, temperature range from 2 degree C to 6 degree C complete with 1 piece stainless steel tray with handle including repair of short circuit/damaged wiring, servising of Indoor/outdoor unit including gas charging complete all as specified and directed. Note:- (i) Maintenance will be carried through OEM only. (ii) Quoted rates are inclusive of oiling, greasing & minor spare parts as required for smooth funtioning.
Servicing & minor repair of Air Curtain with adjustable louvers with electric motor, single phase, 230 Volts AC, 50 Hz with maximum velocity 10-11 Amps (1000mm width), air speed 20M/S of Make: Cecon model No C1-042 with and including minor repair to short circuit/damaged wiring, replacement of defective parts if required complete all as specified and directed.
Supply only anti scalent (cooling tower chemical) R.C. 2100 complete all as specified and directed.
Periodical maintenance (Half yearly basis) of tower AC, capacity 4 TR- 04 Nos & 2 TR- 01 No, 415 Volts, three phase, 50 Hz for operating on R-32 refrigerant with and including servicing of Indoor/outdoor unit including gas charging complete all as specified and directed. Note:- Quoted rates are inclusive of oiling, greasing & minor spare parts as required for smooth funtioning.
Taking out window/split type air conditioner of any make and capacity from position and cleaning the cooling coil & condenser coil with chemical base solution and water including servicing, oiling, greasing, checking of electrical connections and re-fixing in its original position and testing complete all as specified and directed. Note:- Quoted rates are inclusive of oiling, greasing & minor spare parts as required for smooth funtioning.
S&F in replacement new hermitically sealed/ rotary type compressor of 1.5/ 2.0 TR capacity as per site requirement for Window/Split air conditioner complete all as specified and directed.
Deduct Schedule of credit (calculation will be done off line) Rs. 193497.00
ROYAL CONSTRUCTION (BID ID -3190320)
RAJPATI CONSTRUCTION (BID ID -3195066)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .