Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC TARIN JALAL NAGAR SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹10.7 L+₹13,750 (1.30%)Rejected-Finance 687 ARYA NAGAR POWAYAN ROAD SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹11.1 L+₹51,325 (4.85%)Rejected-Finance 65 MATA KA MANDIR RAM NAGAR COLONY SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | L4₹11.2 L+₹64,335 (6.08%)Rejected-Finance | L4 | Rejected-Finance 4TH LOWEST | |
| 5 | L5₹13.8 L+₹3.2 L (30.2%)Rejected-Finance SHOP NO 10 ASHRAM MANDIR NAKATIA P O P A C SHAHJAHANPUR ROAD BAREILLY 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L5 | Rejected-Finance 5TH LOWEST |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
6 Sept 2021, 6:00 pmClosed
GE EAST BAREILLY
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
REPAIR AND MAINT OF INTERNAL WIRING AND FITTINGS REPAIRS TOCEILING FANS EXHAUST FANS GEYSERS SUBMAIN WIRING DBS JUNCTIONBOX AND BUILDING SECURITY LIGHTS ETC AT SHAHJAHANPUR UNDER GEEAST BAREILLY
2021_MES_466175_1
C/8938/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SHAHJAHANPUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE EAST BAREILLY
₹50,000
Yes
23 Sept 2021
7 Aug 2021
8 Sept 2021
7 Aug 2021
6 Sept 2021
24 Aug 2021
7 Aug 2021 - 19 Aug 2021
Amount
Taking down carefully aluminum, light, fan, socket or power point complete including unserviceable fittings such as switches ceiling roses, pendants, regulators, sockets etc at site and making good the disturbed surfaces of walls, floors filling up of holes, plastering white washing distempering etc matching to the existing etc.
M&L for point wiring for one light/fan, bell/ buzzer point controlled by one switch with cable 1.5 Sqmm size PVC insulated (unsheathed) 1100 volts grade single core stranded (multistrand) copper conductor FRLS cable and drawing in and including non metallic rigid PVC concealed conduit medium grade inclusive of conduit fittings such as Bends Teess reducers etc and galvanized iron sheet steel terminal boxes of size 16 gauge thickness, light switches sockets with 3mm thick bakelite laminated sheet brass screws and cup washers including one continuous run of 1.50 Sqmm nominal area PVC insulated unsheathed 1100 Volts grade single core FRLS cable with solid copper conductor green in colour with wire and connecting to earth dolly complete. One light / Fan point controlled by one way switch complete all as specified and directed.
One Bell /Buzzer point controlled by one way switch complete all as specified and directed.
One 3/5 pin 5 Amps socket outlet on independent board complete all as specified and directed.
One 3/5 pin 5 Amps socket outlet on same board complete all as specified and directed.
one light point controlled by two way switches complete all as specified and directed.
All as per item Ser No.2 here in before but with using copper conductor of 2.5 Sqmm for one 3/5 pin socket outlet 15 Amps on independent and using 2.5 Sqmm copper conductor as earth continuty cable compete all as specified and directed.
Supply and fixing switch piano flush type polycarbonate single pole one way 5 Amps complete all as specified and directed.
Supply and fixing socket out let sefty shutter 5 pin 5 Ampsflus type all as specified and directed.
Supply and fix bell push flush type 5 Amps complete all as specified and directed.
Supply and fixing switch piano flush type one way 15 Amps SP complete all as specified.
Supply and fixing socket outlet polycarbonate 2 in 1 , 3 pin 5 / 15 Amps flush type complete all as specified and directed.
S& F swicth flush type 5 Amps single pole two way all as specified and directed.
S&F switch modular flush button single pole one way 15 Amp complete.
S&F socket out let 3 pin 5/15 Amp multipurpose, modular flush type 240 volt complete.
M & L for replacement of Step regulator modular type for ceiling fan of any sweep complete all as specified and directed by Engr-in-Charge.
Supply and fix White cover plates with frame 3 Module
Supply and fix White cover plates with frame 4 Module
Supply and fix White cover plates with frame 8 Module
S&F for lamp holder insulated body of PVC / polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F ceiling rose 3 terminals PVC / Polycarbonate insulated body 65mmx 50mm size complete all as spcified and directed.
Supply and fixing bell ding-dong musical AC 230 Volts single pole complete all as specified and directed.
S&F Stepped type electronics fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with highefficiency PMMA diffuser soft glare free light completewith driver, holders & LED lamp suitable for roofceiling including connecting up with driver threecore flexible copper conductor cases of suitable sizecomplete
Supply & fixing of recessed mounting luminaries with acrylic cover energy efficient decorative designed fixture with flat profile and electronic ballast suitable for 2x36W CFL and including 1x36 watt CFL 4 pin complete in all specified Make :- Bajaj cat Part No BCPA236CFLTDWEB2 or equivalent.
Supply and fix recess mounting LED driver luminar suotable for 36 watts complete all as specified and as directed.MAKE: ,Havells LEDDRIVER36V36WS
Supply and fixing LED lights fitting 1x 20W, 220V,AC 4 feet decorative box type with driver, holder includingLED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceilingrose complete all as specified by Engr-In-Charge.
Supply and fixing LED light fitting mirror type withhigh out put diffuser 2 feet, 10 watt 220 V ACdecorative type with driver holder and LED lampincluding connecting up with three core flexiblecopper conductor cable of suitable size complete.
Supply and fix in replacement wall mounted light fitting LED 10 watts with accessories including 01x10/9 watt LED bulb complete all as specified and as directed. Make - Havells cat No- LHFHCHE1TRW020
Suppply and fixing submain wiring with using two single core 6.0 SQmm copper multy stranded conductor PVC insulated and unsheathed (FRLS) cable and one single core 6.0 Sqmm copper multistandred conductor PVC insulated and unsheathed (FRLS) Earth wire using ISI MArked IS 694 1100 volts grade PVC insulated flexible stranded copper conductor wire drawn through with and including medium grade concealed PV C conduit ISI marked not less than 25 mm dia including conduit fitting and accessories complete including cutting cheses in existing wall of any descirption buiolt in ccement mortor and making good the disturbed surfaces in cement mortor (1:4) and finishing the surfaces to match with existing surfaces and finish termonatioin with bottle type copper lugs conduit being laid either in ceiling slab or wall or on surfaces or under the frame of the false ceiling including PVC flexible conduit or through wooden partition including clamping arrangement as required complete all as sepcified and directed .(Note:- Two Run of 6.0 Sqmm cable and one run of 6.0 sqmm earth wire in and including conduit of suuitable size shall be measured as one unit).
All as per item Ser No.26 here in before but with using copper conductor of 2.5 Sqmm and using 2.5 Sqmm copper conductor as earth continuty cable compete all as specified and directed.
All as per item Ser No.26 here in before but with using copper conductor of 4 Sqmm and using 2.5 Sqmm copper conductor as earth continuty cable compete all as specified and directed.
S&F PVC rectangular gang box multi purpose 5/15 Amps including making connections complete all as specified.
Supply and replace Rigid PVC casing & capping 20/25 mm wide
S&F PVC rectangular gang box multi purpose 5 Amps including making connections complete all as specified.
S&F socket out let 3 pin 5 amp multipurpose modular flash type.
S&F switch 6 Amp modular flush type 240 volt one way complete.
Material & labour for meter box made (sheet metal enclosure) out of MS sheet 2mm thick duly powder coated internall / externally with locking arragements, glass cover for taking meter reading, having sufficient working space and to accmodate these accessories:- (a). MCB Double pole 240 volt 63 Amps - 04 No (b). Taking up/removal of existing energy meter and fixing the same meter box - 04No
Supply and fixing LED street light fitting 35 Watt230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 65/66 protection complete.
M & L for GI Bracket made out of 25 mm GI Pipe light grade 1.20 m length bend to shape including clamps, nuts bolt and washer and fixing to wall/ floor complete as directed by Engr - in - Charge.
S&F for MCB SP 6-32 Amps breaking capacity 10 KA 'C' series 240 volts 50 Hz complete all as specified and directed.
S&F for MCB SP&N 10 to 63 Amps breaking capacity 10 KA 'C' series 240 volts 50 Hz complete all as specified and directed.
S&F for MCB TPN 100 Amps breaking capacity 10 KA 'B' series 415 volts 50 Hz complete all as specified and directed.
S&F MCB distribution board double door sheet steel powder coated DBs suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240 volts and neutral confirms to IS 13032- 1991 of 4 Ways complete all as specified and directed.
S&F double door MCB distribution board sheet steel powder coated DBs suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240 volts and neutral confirms to IS 13032- 1991 of 8 Ways complete all as specified and directed.
S&F double door MCB distribution board sheet steel powder coated DBs suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240 volts and neutral confirms to IS 13032- 1991 of 12 Ways complete all as specified and directed.
S&F vertical three phase distribution board including MCCB 4 pole 100 Amps as incomer with three phase and single phase TP/SP as outgoing complete with insulated bus bar arrangement IP 43 protection with metal door 4 way complete all as specified and as directed by Engr-In-Charge
Taking down the Geyser of capacity 25 / 50 Ltr including disconnecting of electric / water supply connections from building for repair / replacement of defective components and overhauling / checking, servicing , des calling of inner tank , geyser element, checking of geyser assembly and setting of thermostat range complete and refixing the same after repair and testing including making electectric and water supply connection complete all as specified and directed by Engineer-in-charge. Note:- a) All safety precautions for the safety precautions for persons working during removal/fixing back of the Geyser shall be ensured by the contractor . Rates are inclusive of brazing of inner tank of copper for prevention of leakage and replacement of clamps nut bolts gasket set complete . b) Replacement of defective components, painting,etc., which shall be measured and paid for separately.
Supply and Fixing Heating element of capacity 2 kW (cap type / triangular / threaded type), ISI marked, suitable for geyser of capacity 50Ltr complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Heating element of capacity 1.50 KW (cup type), ISI marked, suitable for geyser of capacity 25Ltr complete all as specified and directed by Engineer-in-charge.
Replacement of neon Indicator lamp of red and green colour lamps suitable for geyser of capacity 25/ 50 Ltr of any type / make complet all as specified and directed by Engineer – in – charge
Replacement of Thermostat assembly 16 A,240 AC, ISI marked, suitable for geyser of capacity 25/ 50Ltr of any type / make complet all as specified and directed by Engineer- in- charge .
Replacement of PVC Helical (Hot / Cold) water connection pipe of size 450 mm x 15mm dia with two no of brass nut on each side for geyser complet all as specified and directed by Engineer – in – charge
Replacment of bottom plate of geyser in two pices including painting of approved colour suitable for 25/50 ltr capacity geyser as per original pattern and as approved by Engineer in charge complet all as specified and directed by Engineer – in – charge
Replacment of (4 nos) ,16 mm dia nuts bolts of suitable length duly grouted in walls in cement mortar for fixing of geyser of any capacity complet all as specified and directed by Engineer – in – charge .
Taking out damage glass wool from the geyser and supply fix glass wool all around the inner tank of geyser for maintaining the required temperature complet all as specified and directed by Engineer – in – charge
Replacement of Gun metal Non return valve (NRV) of size 15 mm bore ISI marked completeall as specified and directed by Engr-in-charge.
Replacement of stop valve fancy type cromium plate high pressure surface concealed with crutch of butter fly handle screwed both ends for iron pipe 15 mm bore ISI marked .
M&L for Earthing complete with using GI earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness off 15 cm all around the plate with using 4 mm dia GI Wire as earth lead moulded and retreived to earth plate at one end and connected to main switch / control board at another end with and including 15 mm dia GI light grade from upper end of earth plate upto external face of the wall of the building including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mess fixed on water pipe and provison of PCC 1:2:4 type B-1 (Using 20 mm Dia graded stone aggregate) duly reinforced with mild steel round bar 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handle with and including necessarry excavation and earth work including laying the pipe concealed in floor / wall allas per plate NO-3 of SSR Part-I complete all as specified and directed and testing on completiopn (Note:- If the desired resistance is not found earthing shall be done by the contractor at no extra cost to Govt).
Taking down ceiling fans 48”/56” sweep, cleaning of dust properly cleaning, greasing& overhualing of bearings including refixing and connecting up all as directed .
Supply and fix in repairs 2.50 Mfd capacitior complete all as specified and as directed.
Supply and fix in repairs 3.15 Mfd capacitior complete all as specified and as directed.
Supply and fix in repairs 4.00 Mfd capacitior complete all as specified and as directed.
Supply and fix in repairs ball bearing suitable for exsiting ceiling fans on site complete all as specified and as directed.
Supply and fix in repair ‘U’ clamps complete with nut, bolts & split pins Heavy duty suitable for existing ceiling fan complete all as specified and as directed.
Supply and fix in repair M.S. rod for ceiling fans 3 ft long with ‘U’ clamp at one end other end with out nut bolts washers or screwed thread with check nuts & pin complete all as specified and as directed.
Material and labour for rewinding of burnt fan motor with super enameled copper wire of suitable size 1200/1400mm sweep ceiling fan of any make, type, model including transporation (inclusive of material & labour) complete all as specified and as directed
Taking down exhaust fans 250/300 mm Sweep and cleaning the dust properly, oiling, greasing & overhualing and replacement of defective ,born out parts of bolts and bearings including refixing and connecting up all as directed Note : Replacement of defective/worn out parts will be measured & paid for separately
Taking down exhaust fans 400/450 mm Sweep and cleaning the dust properly, oiling, greasing & overhualing and replacement of defective ,worn out parts of bolts and bearings including refixing and connecting up all as directed Note : Replacement of defective/worn out parts will be measured & paid for separately
Supply and fix Ball bearings suitable for existing exhaust fans as per site.
Supply and fix copper alloy Bush suitable for existing exhaust fans as per site.
Material and Labour for rewinding of exhaust fans 250/300 mm Sweep with super enameled copper wire of suitable size of any make/type/model including transporation complete all as specified and directed.
Material and Labour for rewinding of exhaust fans 400/450 mm Sweep with super enameled copper wire of suitable size of any make/type/model including transporation complete all as specified and directed.
Supply and replace wire of Flexible cord with copper conductor multistanded of twin core 23/0.198 cmplete all as specified and directed.
Supply and replace PVC copper wire of 1.5 sq mm cmplete all as specified and directed.
M/S MANSI TRADERS
M/S CHAUHAN ELECTRIC WORKS
H.B. Traders
NOORI ELECTRIC ENGINEERING WORKS
prabhave traders
S.M. KAZIM
avon electric engineering woks
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .