Loading…
Loading…
Tender Value
₹2.2 Cr
EMD Value
₹4.4 L
Closing Date
17 Jun 2026, 4:30 pm3d left
Dy. General Manager Housing Board Unit-II, Sgr.
Dy. General Manager Housing Board Unit-II, Sgr.
Balance Electrical Works for Proposed Additional Block for JLNM Hospital at Srinagar.
2026_HAUDD_311768_1
e-NIT No. 08 of 2026-27, Dated 06-06-2026
Open Tender
Electrical Works
270 days
Dy. General Manager Housing Board Unit-II, Sgr.
As per NIT
2 documents required · 2 mandatory
₹5,000
Dy. General Manager Housing Board Unit-II, Sgr.
₹4.4 L
Yes
8 Jun 2026
8 Jun 2026
18 Jun 2026
8 Jun 2026
17 Jun 2026
8 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Havells/Polycab/RR Kabel/Finolex (SAMPLE TO BE APPROVED BEFORE INITIATED) | |||||
| 1.01 | Group C | 334 | Point | 1,467 | ₹4,89,978 |
| 2Re-Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class steel/PVC conduit including dismenteling as required. Havells/Polycab/RR Kabel/Finolex (SAMPLE TO BE APPROVED BEFORE INITIATED) | |||||
| 2.01 | Group C | 680 | Point | 894 | ₹6,07,920 |
| 3 | Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required. Havells/Polycab/RR Kabel/Finolex
(SAMPLE TO BE APPROVED BEFORE INITIATED) | 5,575 | Mtr | 334 | ₹18,62,050 |
| 4Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required. Havells/Polycab/RR Kabel/Finolex (SAMPLE TO BE APPROVED BEFORE INITIATED) | |||||
| 4.01 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 230 | Mtr | 233 | ₹53,590 |
| 4.02 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 3,125 | Mtr | 275 | ₹8,59,375 |
| 4.03 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 1,950 | Mtr | 334 | ₹6,51,300 |
| 4.04 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire | 170 | Mtr | 754 | ₹1,28,180 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.71 MB
BOQ_1009321.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid