Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-Finance VASANTASAKHA PLAZA NEAR NAVLE BRIDGE NEXT TO DANGAT CERAMIC HOUSE NARHE PUNE 411 041 | PUNE | MAHARASHTRA | 411041 | ₹30.3 L | L1 | Accepted-Finance L1 Bidder |
| 2 | Rejected-Technical | - | - | Rejected-Technical Documents Not submitted as per Bid Eligiblity Criteria |
| Sl No | Description | Qty | Unit | Virtus Techno L1 |
|---|---|---|---|---|
| 1.00 | SITC of 4 TR, floor mounted Tower type spilt Air-conditioner with remote operation having refrigerant R-32/R 410/R 407a/equivalent Non CFC as per latest standards suitable for 415 V, +/- 10 %, 50Hz, 3-Ph A.C. supply, capable of performing cooling, dehumidifying, air-circulating, filtering etc., interconection between indoor and out door units including installing the outdoor by making PCC foundation/M.S. Stand, minor civil works as per the site conditions and as directed by the Engineer-In-Charge etc. complete as required. | 10 | Job | 1,19,885.64 ₹11,98,856.4 Lowest |
| 2.00 | Supplying and fixing of Copper Piping of size suitable for 4 TR floor mounted Split AC units as per manufacturer's recommendations along with insulation, wrapping between indoor and out door etc. complete as required. | 120 | Meter | 1,121 ₹1,34,520 Lowest |
| 3.00 | Supplying and laying of multi core copper cables of size suitable for 4 TR floor mounted Split AC units as per manufacturer's recommendationsfor connections between indoor and out door units etc. complete as required. | 120 | Meter | 177 ₹21,240 Lowest |
| 4.00 | Supply and Laying of Hard PVC pipe of 40 mm dia (ISI marked) in the floor/wall by cutting the wall, providing MS clamps for the PVC pipe and making good the damages same as original etc. complete as required. | 50 | Meter | 247.8 ₹12,390 Lowest |
| 5.00 | SITC of BEE 5 Star, 1.5 TR Hi-wall Inverter type Split Air conditioners with 4 kVA voltage stabilizer operating on refrigerant R-32/ R-410A/ R-407A/equivalent Non CFC refrigerant as per latest standards suitable for operation on 230 V, 50 Hz, Single phase, capable of performing cooling, dehumidifying, air-circulating, filtering etc., interconection between indoor and out door units including installing the outdoor by making PCC foundation/M.S. Stand, minor civil works as per the site conditions and as directed by the Engineer-In-Charge etc. complete as required. | 12 | Nos | 41,355.46 ₹4,96,265.52 Lowest |
| 6.00 | Extra for supply and fixing of following for interconnections between evaporator unit and condensing unit (for beyond standrd length provided by mfg.) for 1.5 TR AC, as required as per OEM.
i. 1/4"dia copper pipe with insulation or as per OEM.
ii. 1/2" copper pipe with insulation or as per OEM.
iii. Power Supply cable as per OEM. | 48 | Meter | 1,121 ₹53,808 Lowest |
| 7.00 | Providing and laying of 25 mm UPVC drain pipe for with necessary saddles complete etc. as required. | 48 | Meter | 129.8 ₹6,230.4 Lowest |
| 8.00 | SITC of Heavy Duty AC Timer for cyclic operation of Air Conditioners, Automatic Switch Over with Minimum Switching Time 4 Hour, 2 Programming Channels suitable for 1.5 TR Split Acs, Single phase, 50 Hz etc complete as required. (Make Carrier or equivalent) | 3 | Each | 8,850 ₹26,550 Lowest |
| 9.00 | SITC of water dispenser with Inbuilt RO purifier having minimum 03 Faucets (1 Hot, 1 Cold & 1 Normal), 50 LPH purification capacity with min. water storage capacities Hot - 1.1 Ltrs., Cold - 3.3 Ltrs., Normal - 8 Ltrs., auto sanitization of Storage Tank, using Refrigerant R-134 A Green Gas or equivalent, including providing & making inlet, drain connections with existing points within the room etc. complete as required (Make - Zero B, Model - Icy Hot Jumbo RO Hot-Cold-Normal with Display or equivalent). | 3 | Each | 1,98,278.94 ₹5,94,836.82 Lowest |
| 10.00 | SITC of water dispenser with Inbuilt RO purifier having minimum 03 Faucets (1 Hot, 1 Cold & 1 Normal), 10 LPH purification capacity with min. water storage capacities Hot - 1.1 Ltrs., Cold - 20 Ltrs., Normal - 20 Ltrs., auto sanitization of Storage Tank, using Refrigerant R-134 A Green Gas or equivalent, including providing & making inlet, drain connections with existing points within the room etc. complete as required (Make - Zero B, Model - Icy Hot Pro RO Hot-Cold-Normal with Display or equivalent). | 3 | Each | 72,560.56 ₹2,17,681.68 Lowest |
Tender Value
₹38.0 L
EMD Value
₹1.1 L
Closing Date
1 Aug 2025, 6:00 pmClosed
AGM (Engg-E), AAI, Kolhapur Airport
O/o AGM (Engg-E) AAI, Kolhapur Airport
Provision of Split ACs, Water Coolers etc. at New ATC Tower cum Technical Block, Kolhapur Airport
2025_AAI_240827_1
AAI/KOP/ENGG_E/CAP./NIT/Split ACs/2025-26
Open Tender
Electrical Works
Works
90 days
Kolhapur Airport
3 documents required · 3 mandatory
₹1,180
₹1.1 L
28 Aug 2025
10 Jul 2025
4 Aug 2025
10 Jul 2025
1 Aug 2025
10 Jul 2025
10 Jul 2025 - 17 Jul 2025
Amount
SITC of 4 TR, floor mounted Tower type spilt Air-conditioner with remote operation having refrigerant R-32/R 410/R 407a/equivalent Non CFC as per latest standards suitable for 415 V, +/- 10 %, 50Hz, 3-Ph A.C. supply, capable of performing cooling, dehumidifying, air-circulating, filtering etc., interconection between indoor and out door units including installing the outdoor by making PCC foundation/M.S. Stand, minor civil works as per the site conditions and as directed by the Engineer-In-Charge etc. complete as required.
Supplying and fixing of Copper Piping of size suitable for 4 TR floor mounted Split AC units as per manufacturer's recommendations along with insulation, wrapping between indoor and out door etc. complete as required.
Supplying and laying of multi core copper cables of size suitable for 4 TR floor mounted Split AC units as per manufacturer's recommendationsfor connections between indoor and out door units etc. complete as required.
Supply and Laying of Hard PVC pipe of 40 mm dia (ISI marked) in the floor/wall by cutting the wall, providing MS clamps for the PVC pipe and making good the damages same as original etc. complete as required.
SITC of BEE 5 Star, 1.5 TR Hi-wall Inverter type Split Air conditioners with 4 kVA voltage stabilizer operating on refrigerant R-32/ R-410A/ R-407A/equivalent Non CFC refrigerant as per latest standards suitable for operation on 230 V, 50 Hz, Single phase, capable of performing cooling, dehumidifying, air-circulating, filtering etc., interconection between indoor and out door units including installing the outdoor by making PCC foundation/M.S. Stand, minor civil works as per the site conditions and as directed by the Engineer-In-Charge etc. complete as required.
Extra for supply and fixing of following for interconnections between evaporator unit and condensing unit (for beyond standrd length provided by mfg.) for 1.5 TR AC, as required as per OEM. i. 1/4"dia copper pipe with insulation or as per OEM. ii. 1/2" copper pipe with insulation or as per OEM. iii. Power Supply cable as per OEM.
Providing and laying of 25 mm UPVC drain pipe for with necessary saddles complete etc. as required.
SITC of Heavy Duty AC Timer for cyclic operation of Air Conditioners, Automatic Switch Over with Minimum Switching Time 4 Hour, 2 Programming Channels suitable for 1.5 TR Split Acs, Single phase, 50 Hz etc complete as required. (Make Carrier or equivalent)
SITC of water dispenser with Inbuilt RO purifier having minimum 03 Faucets (1 Hot, 1 Cold & 1 Normal), 50 LPH purification capacity with min. water storage capacities Hot - 1.1 Ltrs., Cold - 3.3 Ltrs., Normal - 8 Ltrs., auto sanitization of Storage Tank, using Refrigerant R-134 A Green Gas or equivalent, including providing & making inlet, drain connections with existing points within the room etc. complete as required (Make - Zero B, Model - Icy Hot Jumbo RO Hot-Cold-Normal with Display or equivalent).
SITC of water dispenser with Inbuilt RO purifier having minimum 03 Faucets (1 Hot, 1 Cold & 1 Normal), 10 LPH purification capacity with min. water storage capacities Hot - 1.1 Ltrs., Cold - 20 Ltrs., Normal - 20 Ltrs., auto sanitization of Storage Tank, using Refrigerant R-134 A Green Gas or equivalent, including providing & making inlet, drain connections with existing points within the room etc. complete as required (Make - Zero B, Model - Icy Hot Pro RO Hot-Cold-Normal with Display or equivalent).
Supply of bubble top Hot and Cold water dispenser with three faucets (normal, hot and cold) having capacity not less than 15 litre, with non CFC Refrigerant and 02 Nos duly filled 20 L Water Bottles/Cans etc. as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying Installation, Testing and Commissioning of surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, double door, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's for outgoing and MCCB as incomer, spreader terminals, interconnection between incomer MCCB and bus bars (but without MCCB, MCB's) etc. as required. 12 way (4 + 36), Double door
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 25 KA,FPMCCB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 6 to 32 Amp, Triple Pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 6 to 32 Amp Single pole
Supply of 1.1 KV grade Copper conductor & XLPE insulated and PVC sheathed armoured cable of following sizes conforming to IS:1554(Part 1)1988 / IS:7098 (Part 1) with up to date ammendments. 4C X 6 Sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35 sq. mm and upto 95 sq. mm
Supplying and making end termination with brass compression gland and aluminium / Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium / copper conductor cable of 1.1 KV grade as required 4 X 6 sq. mm (25mm) with Copper lugs
Supplying and making end termination with brass compression gland and aluminium / Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium / copper conductor cable of 1.1 KV grade as required 3½ X 70 sq. mm (38mm) with Aluminium lugs
Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .