Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹60.7 LAccepted-AOC RM 01 RIDHISIDHI I SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹66.6 L+₹5.9 L (9.78%)Rejected-Finance | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder | |
| 3 | L3₹72.0 L+₹11.3 L (18.7%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L3 | Rejected-Finance Rejected being 3rd Lowest Bidder | |
| 4 | L4₹73.4 L+₹12.8 L (21.1%)Rejected-Finance | L4 | Rejected-Finance Rejected being 4th Lowest Bidder |
Tender Value
₹79 L
EMD Value
₹1.4 L
Closing Date
4 Feb 2020, 6:00 pmClosed
CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
SPECIAL REPAIR TO BUILDING NO. P-25/01 TO 08, P-583/01 TO 12 AND P-45/01 TO 08 AT MILITARY STATION SRI GANGANAGAR
2019_MES_286823_1
CA NO. CWE SGNR - 53 OF 2019-20
Open Tender
Civil Works
Item Rate
120 days
GE SRI GANGANAGAR
Class C
Category a(i)
10 documents required · 10 mandatory
₹1,000
GE SRI GANGANAGAR
₹1.4 L
Yes
3 Mar 2020
7 Jan 2020
6 Feb 2020
7 Jan 2020
4 Feb 2020
28 Jan 2020
Amount
Demolition of cement concrete in ground floors and pavings not exc 15 cm thickness (below or above GL) complete all as specified and directed by Engineer-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and applying brushing neat cement slurry with 3.0kg of cement per sqm complete all as specified and directed by Engineer-in-Charge.
M&L 25m thick cement concrete flooring type B1 1:2:4 using 20 mm graded aggregate finished even and fair complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Demolition concrete (reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons laid, bedded and pointed in any mortar etc complete all as specified and directed by Engineer-in-Charge.
M&L 300x200x7 mm thick glazed ceramic coloured tiles as in vertical sufaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles including 10mm backing coat in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L machine cut pre polished kota stone slabs as in vertical surfces such as risers of steps 20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, mirror polishing also moulding edges complete including acking coat 10 mm thick in CM (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L machine cut pre polished kota stone slab flooring 20mm thick (minimum size 55 cms x 55 cms) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, mirror polishing complete including screed bed of mortar 20mm thick for laying floor finishes in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L granite (of any type) work 15 mm thick (table rubbed and polished) in cooking platforms and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including screed bed of mortar 20mm thick for laying floor finishes in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L Non- skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles including 15mm screed bed in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L Non- skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles including 15mm screed bed in CM 1:6, complete all as specified and as directed by Engineer in charge complete all as specified and directed by Engineer-in-Charge.
M & L 50mm thick cement concrete type C1, 1:3:6 using 20 mm graded aggregate finished even and smooth as in plinth protection complete all as specified and directed by Engineer-in-Charge.
M & L for cement concrete type B1, 1:2:4 using 20 mm graded aggregate as in chajja complete all as specified and directed by Engineer-in-Charge.
M & L for M-25 cement concrete using 20 mm graded aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge.
M & L, form work to side & soffits of Chajja for rough finished surfaces complete all as specified and directed by Engineer-in-Charge.
M & L, form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-Charge.
M & L, 10mm dia and over MS TMT bar cut to length bent to shape reqd incl cranking bending etc complete & binding with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-Charge.
S & F TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers, binders etc complete all as specified and directed by Engineer-in-Charge.
Dismatiling brick tiles or terracing tiles, single layer on roofs complete all as specified and directed by Engineer-in-Charge.
Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof complete all as specified and directed by Engineer-in-Charge.
M&L for Roof treatment to RCC roof complete all as specified and directed by Engineer-in-Charge :- (a) Cleaning the roof surfaces thoroughly using wire brushes to remove sharp projections,cleaning joints,washing,drying and removing all dirt/dust to receive concrete padding/ plaster etc complete. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC , finished even and smooth without using extra cement. (c) Providing one coat of approved bituminous primer @ 100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP based polymeric membrane,(mineral finish) minimum weighing 3 Kg/Sqm reinforced with non woven polyster fabric (weight not less than 150 gms/Sqm) by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by Engineer-in-Charge. Makes:-STP, Dr Fixit/Pidilite,Texsa India Ltd Note :- (i) All joints and change in directions should be covered with cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/ as per site requirement and cured well before laying membrane by torching. (ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only.The name of firm shall be got approved from GE before carrying out the work. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarantee of treatment shall be for minimum 10 years reckoned from date of completion of whole work
S&F heat resistance tiles of size 300x300x10mm thick on roof slab of any colour approved over and laid including 15mm thick in CM 1:4.Techinical specification of roof tiles shall be as prer IS 4457:2007 complete all as specified and directed by Engineer-in-Charge. Make: Johnson Endura , Kajaria, Orient
Demolition of cement concrete in sunken floor and floor complete all as specified and directed by Engineer-in-Charge.
M&L for Water proofing treatment to RCC sunken slab (not exceeding 45cm depth of sunken) as specified below complete all as specified and directed by Engineer-in-Charge:- (a) applying 15 mm plaster in CM 1:3 with WPC on raised verticle surface (b) Cleaning the surface with wire brush/coir brush, removing lose material like dust particles, dirt etc. (c) Creating fillet coving of 50x50 mm with polymer modified mortar on the junction of slab and walls (d) Apply first coat of two component modified polymer coating on the horizontal and verticle surface (e) Provision of glass fiber mesh of 2 x 2 mm immediately on above coating (f) Apply second coat of two component modified polymer coating after 72 hrs (g) Cement concrete 1:4:8 over the coating as per requirment (h) Joining the saintary pipes with the water proofing tape having bridging ability of more than 1.5 mm (j) Filling the gap between the wall opening and saintary pipe with non shrink cementatious grout complete all as specified and directed by Engineer-in-Charge. Make:- Dr. Fixit/Fosroc/STP Note: (i) The treatment shall be carried out by approved authorised applicator approved by CWE as per the manufacturers instructions and as directed by the Engianeer in charge. (ii) The Plan area of floor (sunken) shall be considered for payment and provn of cement work (except) PCC in sunken filling item 26 is included in quoted rate for this item. (iii) PCC filling in sunken portion will be measured seperately.
M&L for PCC (1:5:10) type E-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete or filling in sunken floor complete all as specified and directed by Engineer-in-Charge.
Remove cover and loose concrete from main reinforcement using wooden mallets/wire brush/ water jet to complete expose the reinforcement in the distressed portion of column, beam, bracings sand chajja etc. (All loose unsound and cracked concrete should be removed) any height complete all as specified and directed by Engineer-in-Charge.
Remove the rust from reinforcement completely by rubbing with wire brush or sand paper and applying rust removing chemical such as “Deruster” or equivalent by approved make Reebaktens RR Fosroc or Equivalent As approved and removing non metal complex compound formed due to corrosion of rust any height complete all as specified and directed by Engineer-in-Charge.
M&L Primring to reinforcement bars with coat of nitco zinc primer or equivalent as FORSOC / Sika / Dr Fixit or equivalent as approved by GE for old and new reinforcement any height (dia of bars 8mm to 20mm) complete all as specified and directed by Engineer-in-Charge.
M&L applying bond coat (epoxy based) using brush and applying Polymer concrete (not less than 20mm thick)in the proportion of 1:3:1 (one part of cement,3 part of coarse sand and 1 part of 10 mm and down stone aggregate) using 8-10 kg of acrylic basec polymer per 50 kg bag of cement,all as per manufacturers instructions and as directed by Engineer-in-charge,any height complete all as specified and directed by Engineer-in-Charge. Note : The application should be carried out by Manufactorer authorised applicator with gaurentee.
All as per Srl item No. 30 here in before but 2'nd coat n.exc.20mm thick complete all as specified and directed by Engineer-in-Charge.
Dismantling of brick work built in cement mortar complete all as specified and directed by Engineer-in-Charge.
M&L, brick work with fly ash bricks straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 33 here in before but but except bricks complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster any description including raking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L rendering 15 mm thick in CM (1:6) finished even and smooth without using extra cement as on brick work surfaces complete all as specified and directed by Engineer-in-Charge.
M&L 15mm thick rendering in CM 1:4 to brick/ concrete wall surfaces finished even & smooth w/o using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L, 5 mm thick rendering in CM 1:3 on fair faces of concrete surfaces as in ceillings.finished even and smooth w/o using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L two coats of distemper oil emulsion over a coat of putty to newly plastered wall surfaces including preparation of surface complete all as specified and directed by Engineer-in-Charge.
M&L two coats of cement based paint over a coat of white wash of new surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L three coats of white wash to new surfaces on ceilings including preparation of surface complete all as specified and directed by Engineer-in-Charge.
M&L one coat of white wash to old decorated surfaces on ceilings including preparation of surface complete all as specified and directed by Engineer-in-Charge.
M&L one coat of white wash to old decorated wall surfaces including preparation of surface complete all as specified and directed by Engineer-in-Charge.
M&L two coats of oil distempering over old decorated surfaces of wall putty after complete removal of existing treatment including preparation of surface complete all as specified and directed by Engineer-in-Charge.
M&L two coats of cement based paint over primer on old decorated surfaces of walls after complete removal of existing treatment including preparation of surface complete all as specified and directed by Engineer-in-Charge.
M&L one coat of synthetic enamel paint on old painted surfaces of wood and wood based materials over 10 cm width or girth including preparation complete all as specified and directed by Engineer-in-Charge.
M&L two coats of synthetic enamel paint over a coat of primer on new wood and wood based materials over 10 cm width or girth including preparation complete all as specified and directed by Engineer-in-Charge.
M&L two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide on steel surface over 10 cm width or girth, not otherwise described including preparation of new steel surface complete all as specified and directed by Engineer-in-Charge.
M&L one coat of synthetic enamel paint on old painted surfaces of steel and iron work over 10 cm width or girth including preparation complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames without taking off shutters exc 1.5 Sqm but n exc 4 sqm each complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames (without taking off shutters from the frame) not exceeding 1.5 sqm each complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed by Engineer-in-Charge.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars , dovetailed or welded complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 53 here in before but without glazing bars complete all as specified and directed by Engineer-in-Charge.
S&F pressed steel frames 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed by Engineer-in-Charge.
M&L pressed steel frame for doors size 105 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C1 filling of pressed steel frame and hold fast block etc complete all as specified and directed by Engineer-in-Charge.
S&F 35mm thick glazed and skeleton shutters open rebated and prepared to receive gauze etc (without sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred breds for securing glass etc sizes of members of shutters as specified in SSR Pt-I Sec 8 Clause 8.20(a) in 2nd class hard wood complete all as specified and directed by Engineer-in-Charge.
S&F 35mm thick plain,IInd class H/W framed, panelled shutters (any No. of panels), with panels of timber flat on both sides (feather edged)or of veneered particle board medium density, wood particle board with commercial face veneers, 2nd class hard wood complete all as specified and directed by Engineer-in-Charge.
S&F 20mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides. (CB Door) complete all as specified and directed by Engineer-in-Charge.
S&F Continuous( piano) hinges Width of flaps 40mm (when open) in mm, mild steel , bright finish or electro-galvanised complete all as specified and directed by Engineer-in-Charge.
M&L anodised aluminium frames for doors, of size (63mmx38mmx1.95 mm thick) windows, ventilators with one or moe rebates including jointing cleats for fixing etc. complete all as specified and directed by Engineer-in-Charge.
S&F anodised aluminium windows and ventilator shutters, side hung type, without sash bars aluminium saction weighing 0.55 kg/sqm including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fitting such as peg stay 150mm long (1 no) hinges type B21 100 mm long (2 No) suitable handle (1 No.) complete all as specified and directed by Engineer-in-Charge.
S&F in rep stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
S&F in repair 300 mm long, ordinary rat tail rod pattern springs including roller and roller plate complete.(Mild Steel) complete all as specified and directed by Engineer-in-Charge.
S&F in repair 3mm sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 sqm in each pane in hacking out old glasses complete all as specified and directed by Engineer-in-Charge.
S&F 3mm sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
S&F4 mm thick figured glass pin head type and glazing with oil putty in squares n.exc 0.50 sqm each complete all as specified and directed by Engineer-in-Charge.
Supply only butt hinges “medium weight” 100mm size cold rolled mild steel complete all as specified and directed by Engineer-in-Charge.
Supply & fix butt hinges “medium weight” 100mm size cold rolled mild steel complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm mild steel barrel tower bolts, stove enamelled black with bright bolt & fixed complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm aluminium barrel tower bolts, stove enamelled black with bright bolt & fixed complete all as specified and directed by Engineer-in-Charge.
S&F 150mm Mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed by Engineer-in-Charge.
S&F 100mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-Charge.
S&F in repair 150mm Mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed by Engineer-in-Charge.
S&F 300 mm mild steel sliding door bolts, clip type, stone enameled block with bright bolt not less than 12mm dia with and incl a minimum of 6 bolts and nuts, 4 on bolt plate 2 on staple plate complete all as specified and directed by Engineer-in-Charge.
S&F in repair, vitreous china squatting pan "ORISSA" pattern white, of size 580x440mm with integral foot rest, CI 'P' trap etc complete all as specified complete all as specified and directed by Engineer-in-Charge.
S&F in repair, 10 ltr capacity low level PVC valveless, syphonic action type flushing cistern, white, with inlet, ball valve, flush pipe, PVC connection 15 mm dia and 450 mm long float and handle including bracket complete all as specified and directed by Engineer-in-Charge.
S&F PTMT cabinet mirror with mirror of size 450x600mm complete all as specified and directed by Engineer-in-Charge. Make: Prayag Cat Part No. 555 / polytuf / Pearl / Shakti and as approved by GE.
S&F Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300 gms) complete all as specified and directed by Engineer-in-Charge.
S&F for chromiium plated tubular towel rail 20mm dia, D type, 60 cm Long between flanges complete all as specified and directed by Engineer-in-Charge.
Taking up or down 15mm dia, steel tubing & connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
Taking up or down 20mm dia, steel tubing & connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
S&F in rep steel water tubing galvanised 15mm bore, medium grade fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 84 here in before but for fixing only complete all as specified and directed by Engineer-in-Charge.
S&F steel water tubing galvanised 20mm bore, medium grade with all fittings fixed to wall and ceiling or in floor complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 86 here in before but for fixing only complete all as specified and directed by Engineer-in-Charge.
S&F 15mm stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handles, screwed both ends for iron pipe or for unions, fancy type, chromium plated with long shank and cup (concealed type) and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm dia stop valves, cast copper alloy with crutch or butterfly handles screwed down high pressure, screwed both ends for iron and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 20 mm dia stop valves, cast copper alloy with crutch or butterfly handles screwed down high pressure, screwed both ends for iron and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15mm Bib taps fancy type chromium plated cast copper alloy with crutch or butterfly handle , screwed down , scrwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm dia pillar taps & cast copper alloy with capstan heads and chromium plated screwed down with long screwed shanks and fly nut screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
M&L CI floor trap 75mm dia with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 complete all as specified and directed by Engineer-in-Charge.
S&F 15mm bore swivel joint shower rose of PTMT any colour (Minimum weight 400 gms) Brass chromium plated shower rose 125mm size complete all as specified and directed by Engineer-in-Charge.
S&F grating doom 100 mm dia of PTMT (minium weight 25 grams) complete all as specified and directed by Engineer-in-Charge.
Dismantling water tank capacity 500 ltr complete all as specified and directed by Engineer-in-Charge.
S&F rotational molded polythylene water storage tank 500 ltr capacity (Cylinderical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge.
S&F 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms) complete all as specified and directed by Engineer-in-Charge.
Taking down eaves gutter or rain water pipes (any size or pattern) including all fittings, heads, shoes, bends, swan necks etc. complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) rain water pipe single socketed in any length with rubber ring joints, jointed with solvent fixed to wall with matching PVC SWR rings including cutting holes and making good the disturbed portion with PCC (1:2:4) type B0 complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore Door type PVC (SWR) bends any radius complete all as specified and directed by Engineer-in-Charge.
Dismantling cast iron work of any description complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm cast iron (sand cast) soil waste and vent pipes in any length with or without ears with lead joints fixed to walls complete all as specified and directed by Engineer-in-Charge.
S&F 75mm cast iron soil (sand cast) waste and vent pipes in any length with or without ears with cement joints fixed to walls complete all as specified and directed by Engineer-in-Charge.
S&F cast iron bends 100 mm dia (any radius) diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S&F cast iron bends 75 mm dia (any radius) diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S&F in rep harrison rails, anodised aluminium alloy chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed by Engineer-in-Charge.
S&F fiber glass reinforced plastic (FRP) Door frames of three legged of cross section 90mm x45mm having single rebate of 32mmx15mm to receive shutter of 30mm thickness. The laminate door frame molded with fire retardant grade unsaturated polyster resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiberglass from all sides. M S stay shall be provided at the bottom to steady the frame complete all as specified and directed by Engineer-in-Charge.
S&F 30mm thick fiber glass reinforced plastic (FRP paneled Door Shitter of required colour and approved brand and manufacture made with fire-retardant grade unsaturated polyster resin. Moulded to 3mm thick FRP laminate for forming places for fixing of fittings cast monolithically with 5mm thick FRP laminate for panels and conforming to IS 14856-2000 complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel plate rack of size 900mmx775mmx250mm made out of 1mm thick stainless steel of first quality complete all as specified and directed by Engineer-in-Charge. Make:- Anupam International Model No- KPR-311and equivalent approved by GE.
S&F in vitreous china wash basin white, quarter circular, corner type size 400x400mm including brackets, waste coupling of PTMT of 32mm dia, PVC connection 15 mm size PTMT 450 mm long, cutting for and pinning in end of brackets or erecting stand etc. complete all as specified and directed by Engineer-in-Charge.
S&F waste fittings 32mm dia PVC pipe for sinks and basins etc complete all as specified and directed by Engineer-in-Charge.
M&L 100 mm thick cement concrete type D2, 1:4:8 (Using 40mm graded stone aggregate) as in filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for sand filling (40mm thick) under floors or path and levelling foundations including spreading complete all as specified and directed by Engineer-in-Charge.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15468-2006 of 60 mm thickness with grey cement and pigment M-35 Grade 20mm graded stone aggregate) complete all as specified and directed by Engineer-in-Charge.
M&L for pre-cast cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in kerb stone (factory made) with plain fair faces, smooth finish, including chamfering, weathering, throating etc set in cement mortar 1:4, including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, ladders, framed balusters, walk ways, railings etc. and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
M&L for two coat of synthetic enamel paint over a coat of red oxide (factory) including preparation of new steel Surfaces of any description, .exc 10cm in width or girth complete all as specified and directed by Engineer-in-Charge.
M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including fittings such as switches, ceiling roses, pendent holders, light fittings any type, sockets, regulators etc and making good disturbed surfaces of walls and floors etc to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring complete with 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable drawn in and including concealed PVC rigid conduit pipe medium grade 20mm dia using pipe hooks, elbows, junction covers and junction boxes including provision of 1.2mm thick pressed steel sunken terminal boxes 60mm deep, suitable length and painted with red oxide primer for mounting switches, sockets, fan regulators covered with and including 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 1.5 Sqmm PVC insulated solid / multi standard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point controlled by one switch, bell push or one fan point controlled by one switch and making the good of disturb surface of wall with CM 1:3 with white wash or existing colour complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 122 here in before, but for one switch socket combination 5/6 Amps on independent board complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 122 here in before, but for one 3 pin socket outlet 5 Amps on same board with other switches complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 122 here in before, but with multi-stranded copper conductor FRLS PVC unsheathed cable of cross sectional area 2.5 Sqmm for one switch socket combination 6 pin, 15 Amps on independent board including 2.5 Sqmm PVC insulated solid / multi standard copper conductor wire as earth continuity to common earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 122 here in before, but for one light point controlled by two 2 way swiches complete all as specified & directed by Engineer-in- Charge.
All as per Srl item No 122 here in before, but for call bell point complete all as specified & directed by Engineer-in- Charge.
M&L for point wiring complete with 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable drawn in and existing concealed PVC regid conduit using new sunken boxes of cast iron / pressed steel terminal boxes suitable length and thickness for mounting switches, sockets, fan regulator with 3mm thick plastic laminated sheet cover fixed with brass screws and cup washers, duly grouted and painted with red oxide metal primer and including provision of continous earth continuity conductor alongwith point wiring of 1.5 Sqmm copper PVC insulated cable for one light / fan point controlled by one switch and connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 128 here in before, but for one 3 pin socket combination 5/6 Amps on indipendent board complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 128 here in before, but for one 3 pin socket outlet 5 Amps on same board complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 128 above, but with multi-stranded copper conductor FRLS PVC sheathed cable of cross sectional area 2.5 Sqmm including 2.5 Sqmm PVC insulated solid copper conductor wire as earth continuity to common earth dolly for 5 Pin 15 Amp socket combination outlet on independant board complete all as specified & directed by Engineer-in-Charge.
S&F switch piano flush type single pole one way 5/6 Amps, 230 volts complete all as specified & directed by Engineer-in- charge.
S&F switch piano flush type single pole two ways 5/6 Amps, 230 volts complete all as specified & directed by Engineer-in- charge.
S&F bell push flush type 5 Amps complete all as specified and directed by Engineer-in-Charge
S&F switch socket combination 5 Pin, 5/6 Amps flush type complete all as specified and directed by Engineer-in-Charge.
S&F switch socket combination 6 Pin, 5/15 Amps flush type complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet 5 Pin, 5 Amps flush type complete all as specified and directed by Engineer-in-Charge.
S&F ceiling rose polycarbonate surface bakelite 65 x 50mm size three terminals complete all as specified and directed by Engineer-in-Charge.
S&F electronic bell ding dong type, AC 230 Volt single pole complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of existing light fittings with batton integrated LED channel 20 Watt (integral sleek extruded polycarbonate body LED with white acrylic cover) tube light fittings wall mounted complete with rod driver and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2mm upto ceiling rose / connector complete all as specified and directed by Engineer-in-Charge.
S&F angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer-in-Charge.
S&F water tight bulk head fittings, comprision of connector galvanized cast iron back plate, wheather proof enamelled gallery, glass well and including 10 Watt LED lamp complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of sub-main wiring with two runs of single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn into and including PVC concealed conduit, including one run of 6 Sqmm (Nominal Area) copper cable as earth continuity conductor including necessary connections, PVC flexible pipes are used in panel board while connecting the cable complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F in repairs factory made sheet metal enclosure for double door distribution board made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 way, 240 Volts, ISI Marked, 200 Amps bus bar stove enameled dust and vermin proof suitable for incorporation of MCBs and Isolators etc. complete all as specified & directed by Engineer-in-Charge.
S&F factory made sheet metal enclosure for double door vertical distribution board made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy power coated surface mounting VTPN 4 Ways 415 Volts ISI Marked, 125 Amps bus bar stove enameled dust and vermin proof, IP-43 protection suitable for incorporation of FP MCCB (V-Tech) N1 Frame upto 125 Amps, Isolators and including to give connection with wire and cable etc. complete all as specified & directed by Engineer-in-Charge.
S&F MCCB TPN 63 Amps with breaking capacity of 25 KA, fixed TM and 415 volts, AC supply, ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, MCB 'B' series type suitable for 240 volts, AC supply, 5 to 40 Amps, single pole with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, MCB 'B' series type suitable for 240 volts, AC supply, 5 to 40 Amps, SP & N with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with 2 Nos of mild steel clamp made out 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame 40 x 40 x 6mm on top and excavation/ earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Note:- (i) Outer edge of earth pit shall be 1 metre away from the outer edge of PCC chamber. (ii) GI strip upto earth test point/equipment is included in this item. (iii) Water pipe upto earth pit shall be provided in slantling position as included in this item.
S&F security light fittings LED type 25 Watt with all necessary accessories, clear transparent acrylic cover, prewire suitable to operated on 230 Volts, 50 Hz, AC and supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 32mm bore "light grade" brackets 2 Mtr length bent to shape to obtain required shape including clamps, nuts, bolts, washers etc. connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer-in-Charge.
S&F stepped type, single socket fan regulator for ceiling fan 1200mm / 1400mm sweep complete all as specified and directed by Engineer-in-Charge.
Supplying and laying GI pipes light grade 50mm dia for cable crossing in floors and fixing with existing light pole including nuts, bolts, clamps etc. complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in soft/loose soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified & directed by Engineer-in-charge.
Removal of excavated surplus soil to a distance n.exc 250m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge .
M & L for sand cushioning with river washed and screened dry fine sand to under ground cable after laying the cable jently punning down complete all as specified and directed by Engineer-in-Charge. NOTE:- Thickness after punning shall be considered for payment.
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing and testing and commissioning of 16 sqmm, 4 core XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note :Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ.
Dismantling and refixing of ceiling fans of any size including providing fan hooks clamps etc. complete all as specified and directed by Engineer-in-Charge -------------------------------------------------------------------------------------------------------------- Note : A sum of Rs. 1,49,571.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 41, 42 & 43(R) (Schedule of Credit) of Tender document
Aggarwal brothers and company
M/S BUDHRAM BISHNOI
M/S KARNI CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .