| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 CrAccepted-AOC WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | ₹3.8 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹3.8 Cr+₹2.0 L (0.52%)Rejected-Finance | ₹3.8 Cr+₹2.0 L (0.52%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹4.0 Cr+₹24.0 L (6.39%)Rejected-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹4.0 Cr+₹24.0 L (6.39%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹4.0 Cr+₹28.0 L (7.44%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | ₹4.0 Cr+₹28.0 L (7.44%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹4.1 Cr+₹36.3 L (9.67%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | ₹4.1 Cr+₹36.3 L (9.67%) | L5 | Rejected-Finance Not being lowest |
Tender Value
Refer Docs
EMD Value
₹4.8 L
Closing Date
28 Jan 2023, 6:00 pmClosed
Chief Engineer
HQ Chief Engineer Delhi Zone, Delhi Cantt-10
SPECIAL REPAIR FOR CONVERSION OF OVERHEAD LINE TO LT UNDERGROUND XLPE CABLES AT 255 TRANSIT CAMP,406 LT AD PERSONAL LINE, HAZIPEER LINE, KHYBER LINE, ASSU UNIT, ARTRAC HUT OR LIVING AREA
2022_MES_570208_1
CA No CEDZ/TOKEN-68 of 2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Delhi Cantt
MES contractor enlisted in MES under class A cat b i having deposited Standing Security of Rs 700000.00 with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹3,000
GE(U) Electric Supply, Delhi Cantt-10
₹4.8 L
Yes
13 Feb 2023
20 Dec 2022
30 Jan 2023
20 Dec 2022
28 Jan 2023
16 Jan 2023
20 Dec 2022 - 7 Jan 2023
Amount
Dismantling of MS channel or Angle iron or flat iron sections from LT/HT poles complete all as specified and directed
Dismantling of insulators of any type and any size from RCC/PCC LT/HT poles complete all as specified and directed
Dismantling carefully Old unserviceble ACSR conductor / jumper from LT/HT Poles complete all as specified and directed
Dismantling & Removing carefully Old unserviceble LT cables/ Service cable of size 16 sqmm to 35 sqmm from LT Pole to MCB DB complete all as specified and directed
Dismantling of air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism complete all as specified and directed
Dismantling of of any type and any size of LT RCC/PCC poles complete all as specified and directed
Dismantaling of existing 4/6/8 pole structure complete all as specified and directed
(ii) Multifunction energy meter (Make: Schneider, L&T, El measure); three phase to Measure V, I, Hz, Kw, KVAr, KVA, PF, PA, I/E, KWH &KVArh, KVAh, Demand & Max Demand - A, Kw & KVA, etc. with inbuilt RS 485/MODBUS Card along with necessary CTs acc class 0.5 ,10 VA Aux Supply: 230 V :- 01 Sets (iii) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set.(Make BCH/SIEMENS/L&T) (iv) Aluminium bus bar of rating 1000 Amp- set of four (b) Outgoing (i) MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 36 KA, rupturing capacity with adjustable Thermal and Magnetic setting releases -02 Nos (ii) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 16 KA, rupturing capacity with adjustable Thermal and Magnetic setting releases - 02 Nos (c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer (iii) Provision of One spare MCCB and one spare MCB chamber in panel to be made for future extension .Make of MCCB/MCB-Legrand/Havells/L&T
(iv) 3 Nos of CTs of ratio 200/5 Amp copper wound, Class 1.0, 10 VA – 1 Set (v) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set (Make BCH/SIEMENS/L&T) (vi) Aluminum bus bar of rating 300 Amp- set of four OUTGOING (i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 63 Amps rating 16 KA rupturing capacity with adjustable Thermal and Magnetic setting releases, - 04 Nos. (ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 40 Amps rating 16 KA rupturing capacity with adjustable Thermal and Magnetic setting releases, - 02 Nos. Make of MCCB/MCB-Legrand/Havells/L&T
(v) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set (Make BCH/SIEMENS/L&T) (vi) Aluminium bus bar of rating 600 Amp- set of four OUTGOING (i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 250 Amp Amps rating 25 KA rupturing capacity with adjustable Thermal and Magnetic setting releases, - 01 Nos. (ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 160 Amps rating 25 KA rupturing capacity with adjustable Thermal and Magnetic setting releases, - 01 Nos, (iii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 100 Amps rating 16 KA rupturing capacity with adjustable Thermal and Magnetic setting releases, - 02 Nos, (iv) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 32 Amps rating 16 KA rupturing capacity with adjustable Thermal and Magnetic setting releases, - 02 Nos,Make of MCCB/MCB-Legrand/Havells/L&T
Supply, installing, testing and commissioning of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement ,of size 450mm x 450mm x 300mm with 4 Nos 200 Amps aluminium bus bar and with 100 Amp MCCB, 4 pole, 25 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for Bus bar chamber. The platform shall be such that it is of a height 45 cm above the nearest road level.
Supply, installing, testing and commissioning of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement ,of size 450mm x 450mm x 300mm with 4 Nos 200 Amps aluminium bus bar and with 63 Amp MCCB, 4 pole, 25 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for Bus bar chamber. The platform shall be such that it is of a height 45 cm above the nearest road level.
Supply, installing, testing and commissioning of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement ,of size 450mm x 450mm x 300mm with 4 Nos 500 Amps aluminium bus bar and with 250 Amp MCCB, 4 pole, 36 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for Bus bar chamber. The platform shall be such that it is of a height 45 cm above the nearest road level complete all as specified and directed
Supply, installing, testing and commissioning of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement ,of size 450mm x 450mm x 300mm with 4 Nos 320 Amps aluminium bus bar and with MCCB 160 Amps 4 pole, 25 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for Bus bar chamber. The platform shall be such that it is of a height 45 cm above the nearest road level complete all as specified and directed
Supplying, laying, jointing testing and connecting of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed of following sizes:- Note :- (i)Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule. (ii) Qty More Than 1000 Rm LT cables to be embossed with CA NO in every running mtrs (a) 16 Sqmm 4 core
(b) All as per item No 50 here-in-before but 25 Sqmm 4 core
(c) All as per item No 50 here-in-before but 35 Sq mm 3.5 core.
(d) All as per item No 50 here-in-before but 50 Sq mm 3.5 core.
(e) All as per item No 50 here-in-before but f 70 Sqmm 3.5 core
(f) All as per item No 50 here-in-before but 95 Sqmm 3.5 core
(g) All as per item No 50 here-in-before but 120 Sqmm 3.5 core
(h) All as per item No 50 here-in-before but 150 Sqmm 3.5 core
(j) All as per item No 50 here-in-before but 185 Sqmm 3.5 core
(k) All as per item No 50 here-in-before but 240 Sqmm 3.5 core
(l) All as per item No 50 here-in-before but 400 Sqmm 3.5 core Note:- 350 RM of 150 Sqmmx3.5C ,75 RM of 185 Sqmm x 3.5C LT XLPE cable are consider for DG set in replacment of old LT Cables
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level complete all as specified and directed
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed
S&F sub class B bricks of size 230mmx115mmx70mm having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed
M & L for Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.1 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized Iron strip 32x6mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe light grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
S&F KIOSK box weather proof made out of PVC, one piece moulded SMC base and out door pole mounted hinged door size 333 x 233 x 120 mm out side and 300 x 200 x 105mm inside dimensions comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amp and 6 Amp MCB SP with base for controlling the street light, FI clamps 30x4 mm with necessary MS nuts bolts and washers including embossing/painting of Danger notice of size not less than 10 cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed
Supply drawing, connecting and testing of 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from KIOSK box to street light fitting including providing suitable copper lugs complete all as specified and directed
Supply & installing steel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II), complete with cast iron/MS plate 6mm thick and of size 300x300mm, final taper, pole cap, bolts, nuts, washers & screw etc including excavation, earth work, PCC foundation,PCC coping,GI pipe for cable protection etc. and GI bracket for fitting mounting, complete all as per manufacturer's instructions complete all as specified and directed NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings along with clamps. The steel pole shall be painted by bituminious paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminium paint over a coat of red oxide complete all as specified and directed.
S&F LED street light Fitting 70/72 watt LED, IP-66 protection, Energy saving LED STREET LIGHT & Secondary optical lens for superior light distribution Efficacy >110 Lm/W, 5700K , single peice pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 4.5 KV, prewired conductor to fitting with 3 core 1.5 sqmm pvc insulated cable along with GI pipe bracket for street light fitting complete with 2.2 mtr long 50mm dia GI pipe medium grade and including necessary mild steel clamp , nuts,bolts and wahsers and painting on steel surfaces with two coats of aluminium paint complete as as specified and directed.
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of HDPE pipe 40 to 100 mm bore and making good both ends all specified and directed
M/L for HDPE pipe suitable for 5 kgf/cm 2 working pressurewith all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed of following sizes (a) 40 mm dia
(b) All as per item No 62 here-in-before but 50 mm dia
(c) All as per item No 62 here-in-before but 80 mm dia
(d) All as per item No 62 here-in-before but 100 mm dia
M&L for Demolation of road, path, drain and concrete in ground floors, RCC/Brick wall (below or above ground level) complete all as specified and as directed.
M&L for providing cement concrete 1:2:4 type B-2 (using 40 mm grade crushed stone aggregate) 250 mm Thick complete all as specified and as directed
S&F time switches astro type in having longitude and latitude of Indian cities in memory 415 V three phase 20 Amp rating with 20 Amps, 415 Volts, three pole contactor fitted inside factory made 2mm thick steel enclosure duly powder coated paint complete all as specified and directed.
Supplying, installation, testing and commissioning of 11 KV 630 Amps having short circuit capacity 21 kA for 3 sec, Outdoor (IP54), RMU (Ring main unit) 3 way comprising of 02 Nos motorized operated load breaker and 01 No 630 Amps fixed type motorized spring charging VCB electrolytic grade copper bus bars all inside single, gas filled, robotic welded non-magnetic stainless steel 304 or better grade, IP 67 Degree of Protection tank with min thickness 2.5 mm +/- 0.1mm, min thickness for load bearing/outer sheet 2 mm and 1.6 mm for non-load bearing member, internal arc IAC AFLR classification, 21 kA for 1 sec for gas tank and Cable chambers. The enclosure shall have pad lockable doors as per OEM design, fully covering the front facia and cable boxes, ensure fail safe anti-theft protection. The unit along with Bus connected, fixed type Auxiliary transformer shall include the following along with all necessary accessories and fittings are required at site:-
(A) Incoming Load Break Module - Each consisting of following accessories: (i) Each switching – unit is designed as a three position switch. This three function switch combines the function of switch – disconnector an earthing switch (ii) 11 KV, 630 A Load Breaker Switch with interlocking line -earthing scheme both short circuit current, 21 KA for 3 Sec Making capacity – 50 kAp- 01 No (iii) Auxiliary contacts – 1 NO + 1 NC- 01 No. (iv) Spring assisted motorized mechanism with un-inhabited operating shaft for emergency manual operation with integrated earthing switch – 01 No (v) Cable terminals cable bushing situated not beyond 300 mm or as per OEM tested design from cable cover to allow ease of access for installation/testing) with door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access of size upto 11 KV, 300 Sq mm, 3 Core, along with XLPE AL cable termination / End Kits Each set of 3 (vi) Right angle boots (push on type) Each set of 3 (vii) Arc proof cable covers having cable entry from bottom, front with interlocking mechanism including earth switch – 01 No. (viii) Capacitive voltage indication fixed type system as per IEC 6123 with LED – 01 Set (ix) Fault passage indicator – It is to be provided for each incomer Load break unit, FPI with LED / digital display to be added to detection of cable fault – 01 No (x) ON, OFF, Earth mechanical indication on the front mimic of the panel – 01 No Cable cover standard - 01.
(B) Outgoing VCB Module - Each consisting of following accessories: - (i) Each function – unit consists of a vacuum – circuit breaker in combination with a three position – switch. The three-position switch fulfils the operation of the disconnector and earthing function. (ii) 11 KV, 630 Amps Fixed type VCB module with series disconnector cum earthing switch of short circuit breaking current / withstand, 21 KA for 3 Sec Making Capacity – 50 kAp - 01 No (iii) Auxiliary contacts – 1 NO + 1 NC- 01 No. (iv) Stored – energy motorized high – endurance spring charging mechanism (M1+), with inbuilt spring charging lever and mechanically latched ON/OFF push -buttons to allow handle less and un-inhabited operation – 01 No. (v) Cable terminals cable bushing situated not beyond 300 mm or as per OEM tested design from cable cover to allow ease of access for installation/testing) with door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access up to 11 KV, 185 Sq mm, 3 Core, along with XLPE AL cable termination Each set of 3 (vi) Right angle boots (push on type) Each set of 3 (vii) 3 O/C + 1 E/F self-powered numerical protection relay with low and high set for over current and Earth Fault. Relay should have facilities to display the maximum loaded phase current also. Relay shall record minimum 5 fault records with time stamping. Relay shall be communicable with RS 485 Port on MODBUS Protocol – 01 No/per VCB outgoing. (viii) Auxiliary Relay for OTI / WTI – transformer protection – 01 No
(ix) Associated ring Core cast- resin insulated CTs Dual Ratio 100/50/1-1 or 80/40/1-1 or 50-25/1-1 Amp as per site reqmt (for metering and protection) 2.5 VA, 5 P 10 Protection – Each set of 3 (x) Arc proof cable covers having cable entry from bottom, front with interlocking mechanism including earth switch – 01 No. (xi) Capacitive voltage indication fixed type system as per IEC 6123 with LED – 01 Set (xii) ON, OFF, Earth mechanical indication on the front mimic of the panel – 01 No (xiii) Emergency trip push button – 01 No. (xiv) CB mechanical operation should be min 10000 Nos without any maintenance. (xv) Vacuum Interrupter and VCB must be RMU manufacturer’s own make for better life cycle optimization.
(C) Bus connected, fixed type Potential and Auxiliary transformer with floor mounted compartment of matching height and depth, positioned alongside RMU to provide required aux. supply for spring charging motor and metering, consisting of following accessories:- (i) 1-Ph 11 KV/110V, class 0.5 potential transformer – 03 Nos for metering. (ii) 1-Ph (11 KV/rt3), 230 VAC, 250/500 VA Auxiliary transformer – 01 No for battery charging. (iii) 11 KV Tri vector Energy Meter of Class 0.5 accuracy with RS 485 Communication – 01 No per VCB o/g (iv) 2x12 Volt DC battery – 01 Set (v) 230 VAC/24 VDC Battery charger – 01 No, with indication of status of functioning (vi) HRC fuse links for primary side isolation and AC/DC MCBs for secondary isolation – 01 Set (vii) Voltmeter & RYB LED indications to confirm AC/DC supply availability – 01 Set (viii) Anti condensation space heater with thermostat – 01 No (ix) LED lamp for illumination and 3 pin socket with switch – 01 No
(D) Standard mano meter -01 for each tank, Operating handle - 02, cable clamping provision (standard)-01/for every cable entry, Operation and maintenance manual - 01, installation and commissioning manual - 01, RMU Foundation as per OEM Recommendation (Earth Work and PCC works) for placing RMU on plinth is deemed to be included in the cost quoted. Height of plinth should not be less than 0.45 mtrs from ground level.
NOTE:- 1.The above module consisting of Load break Switches and VCBs shall be aligned appropriately and must have electrical and mechanical interlocking as per latest electrical safety norms including installation on platform as recommended by OEM.2.
All as per item No 66 here-in-before but RMU (Ring Main Unit) 4-way comprising of 02 Nos motorized operated load breaker and 02 Nos 630 Amps fixed type motorized spring charging VCB.
M&L Brick work with sub-class 'B' bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed
M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4) finished fair and even without using extra cement complete as specified and directed.
M & L for PCC 1:3:6 type C-2 (using 40 mm gradded aggregate) for foundation, filling and mass concrete etc complete all as specified and directed .
M & L for cement concrete type B-2, 1:2:4, 75 mm thick (using 40 mm gradded aggregate) for floors and paving etc complete all as specified and directed.
S&F equal Angle iron, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed
S&F 4 mm thick mild steel wire 50x25 mm mesh up into mattressess or cages, lapped wired and fixed in position including welded for fencing to grid in cluding one coat of primer and two coat ot synthetic enamel paint complete all as specified and directed.
M & L for 2 coat of synthetic enamel painting over a coat of red oxide to steel surfaces including preparation of newly surface complete all as specified.
M & L 60 mm thick PCC interlocking tiles, rubber moulded and chemically coated, using grey cement and pigment of size and shape as approved, including 100 mm thick bed with PCC 1:2:4 type B1 with 20mm graded aggregate and layer of dry sand not less than 40 mm thick, interstices filled in floors/ pathway incuding locking the the tiles on all four sides with PCC complete all as specified and directed . (Note :- PCC & Sand cushion shall not be measured and paid separately).
Matrial and labour for complete removal of Damaged End Outdoor Type termintion Kit of Transformer End and Supply and Fixing of New End Termination Kit Heat Shrinkable indoor type cable of size 70 to 120 sqmm 3 core with jointing materials and acessories complete all as specified and directed
(b) All as per item No 76 here-in-before but 150 Sqmm to 240 Sqmm, 3 core.
(c) All as per item No 76 here-in-before but 300 Sqmm to 400 Sqmm 3 core
Supply and fix cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured AI conductor cable of size 70 to 120 sqmm. complete all as specified and directed
(b) All as per item No 77 here-in-before but150 Sqmm to 240 Sqmm, 3 core.
(c) All as per item No 77 here-in-before but 300 Sqmm to 400 Sqmm 3 core
M&L brick masonry platform (suitable for 100 to 400 KVA transformer) having size 2.5 mtr x 2.5 mtr and total height 1.6 M (0.45 M below ground level including excavation and earth work, 1.15M above ground level including RCC slab 150 mm on top and refilling of sand/soil), PCC 1:4:8 type D-2 in foundation, sub class 'B' brick work in CM 1:4, 15mm thick rendering in CM 1:6 on all sides of platform upto 150 mm below ground level, supply and fixing of 02 Nos MS channels of suitable size for balancing of transformer, embedded in PCC 1:2:4 type B-1 up to 150mm thick RCC slab, including provn of stair case on one side complete all as specified and directed.
Disconnecting electrically and mechanically outdoor transformers upto 400 KVA capacity, lowering down from 4/6/8 pole structure carefully using hydra machine and Re-installation of transformer on plinth, connecting electrically and mechanically, testing and commissioning complete all as specified and directed.
Supplying, laying, jointing testing and connecting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 120 sqmm 3 core with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed. Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
(b) All as per item No 80 here-in-before but 150 Sqmm 3 core
(c) All as per item No 80 here-in-before but 185 Sqmm 3core
(d) All as per item No 80 here-in-before but 240 Sqmm 3 core
(e) All as per item No 80 here-in-before but 300 Sqmm 3core
(f) All as per item No 80 here-in-before but 400 Sqmm 3 core
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core 120 sqmm XLPE armoured aluminium conductor cable complete all as specified and directed.
Supply and laying factory made non-reinforced precast concrete cable cover class HV type-I with size 300mmx180mmx40mm all as specified and directed.
Taking out of Old LT cables 1100 Volts grade of size 150 Sqmm 3.5 Core for 125 KVA DG SET AMF Panel TO Mains Panel complete all as specified and directed.
Taking out of Old LT cables 1100 Volts grade of size 1100 Volts grade of size 185 Sqmm 3.5 Core for 160 KVA DG SET AMF Panel TO Mains Panel complete all as specified and directed.
Supply & installation of water cooled Diesel Engine driven Prime duty Generating Set of capacity after all derating factors net of not less than 125 KVA/100 KW ,50Hz 415 volt 3 phase, 4 wire,0.8 lagg , 155 bhp 1500 RPM minimum Required Power for Rated kVA (bhp)along with AMF system with Acoustic Enclosure as per CPCB-II Norms, exhaust silencer-Hospital Grade in line including following
Engine comprising of the following: Rugged engine natural liquid cooled (EG Compleat 50:50) with radiator as secondary media with world class OEM such as Cummins/Perkins/Kohler/Greaves/Ashok Leyland Engines for powered diesel generator set Advanced in-cylinder technology turbo charged , air cooled aspriated to meet latest emission norms without any after-treatment device. Class defining technology engine is designed to meet stringent exhaust emission tests as per revised MoEF norms, thus offering environment friendly powe Compact in size , cylinder, In-line 4 stroke, radiator cooled engine Well designed air handling system with Dry type, heavy duty, replaceable paper element aircleaner with restriction indicator, Air to air aftercooling,Optimised turbocharger for increased altitudecapabilities, Best in class fuel economy with Inline fuel pump with A1 class mechanical governing, Spin on fuel filter, Standard integral set-mounted radiator system, designedand tested for 50°C ambient temperature,Full flow spin on lube oil filte,First fill of lube oil and coolant, Electrical starter motor with soft start engagement feature, Battery charging alternator,1 x 12 V DC battery/Alternator
AlternatorPMG type comprising of the following: Stamford UC/jyothi/crompton alternator frames from Technologies Brushless type, Screen protected, Revolving field, Self excited alternator conforming to IS/IEC 60034-13 Phase reconnectable winding with 12 terminals brought out for connection Dedicated winding specially designed for 3 phase operation Better motor starting capability Best in class efficiency Compact design with sealed bearings for longer life andlesser maintenance Impregnation on all wound components for bettermechanical strength ,alternator of IP 23,Voltage regulation (Max.)±1%, Class of Insulation H Class, Winding Pitch 2/3, Stator Winding Double layer lap Rotor Dynamically Balanced,Waveform distortion/ Total Harmonic Distortion No load < 1.5 %, Non distorting balanced linear load < 5 %,Maximum Unbalanced Load across phases# less than or equal to 25%, Telephonic Harmonic factor < 2% alternator capcity out put shall not be less than 125 KVA ,50Hz 415 volt 3 phase, 4 wire,0.8 lagg. 175 Amp / phase
Control Panel comprising of the following: c) Outdoor type AMF / Control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish.The control panel consists of the following parts of makes as per OEM recomendation: microprocessor based generator set monitoring and control system. AMF Functionality is inbuilt and this control includes an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration, and diagnostics, Copper bus bars with suitable capacity with incoming/outgoing terminals, Indicating lamps for ‘Load ON’ and ‘Set Running’,Instrument fuses / MCBs duly wired and ferruled, Circuit breakers of suitable rating with overload and shortcircuit protections. along with motorised change overs /on load power contactors with copper busbars, cables and protective acessories with load / bypass arrangements
Hospital grade silencer silencer suitably optimized to meet stringen noise emission standards laid down by MoEF / CPCBalong with MS supporting structures .along with thermal Insulation on horizontal pipe with Rock Conforms to IS-8183 Wool/ 100mm Thickness and 96 Kg /metric Cube density.
Controller should be compatable to the following specifications: (i) AMF Functionality controllers of Makes from the OEM : Deep Sea/ Cummins/ Wood Ward/ Com Amp (II) Intuitive operator interface which includes LED backlit 128X64 pixel graphic display with tactile feel soft-switches.Indications - Generator set, Utility Status Lamp. (iii) Remote start-stop with Engine Metering: Oil pressure, Engine temperature, Startingbattery voltage, Engine running hours (iv) AC Alternator Metering: L-L Voltage and L-N Voltage,Current (phase and total), kVA (phase and total) andFrequency. kwh, Total & per phase (kw & kVA), PF, UtilityVoltage and Freq. (v)Engine Protection: Low lube oil pressure, High/Low coolanttemperature, Battery Over/Under/Weak Volts, Fail to Crank/Start, Sensor failure, Cranking lockout, Low fuel level. (vi)AC Alternator Protection: Over/Under Voltage, Over/UnderFrequency, Loss of AC sensing. Overspeed, Over Current. (vii)Data Logging: Engine hours, Control hours and upto 5 recent fault codes (viii) Configurable glow plug control,Cycle Cranking (ix)12/24 Volt DC operation,Sleep mode,Modbus interface (RS485 RTU),InPower compatible (PC based service tool),Certifications - meets the requirement of relevant ISO, EN,Mil Std. and CE standards (x)Maintenance due alarm based on Engine Run Time and duedate,Exercisor scheduler (xi) Remote HMI , Digital electronic governor with temperture compensation and smooth starting , digital AVR for shunt of PMG excitor with Torque monitoring, Digital electronic governor with temperture compensation and smooth starting, (xii) Multifunction energy meter (Make: Schneider, L&T, El measure); three phase to Measure V, I, Hz, Kw, KVAr, KVA, PF, PA, I/E, KWH &KVArh, KVAh, Demand & Max Demand - A, Kw & KVA, etc. with inbuilt RS 485/MODBUS Card along with necessary CTs acc class 0.5 ,10 VA Aux Supply: 230 V :- 01 Sets
All pipe line connections, valves etc.required for the lube oils, fuel and cooling system
Battery & Battery charger of rated capacity as per the alternator/ Engine compatability
Mounting Arrangement shall be of the following: (i) Engine and alternator are mounted on a common MSfabricated base frame with AVM pads. (ii) Base frame with integral fuel tank is provided with drainplug, air vent, inlet and outlet connection, level indicator andprovision for cleaning
Fuel Tank of capacity 08-10 hrs running capacity along with Fuel pipe MS c class 25mm ID with bends , flanges , valves, tees and bends.
Controll / service cables shall be of 4cx 2.5 sqmm, 24 c x 2.5 sqmm , 2 c x 2.5 sqmm, and 8c x 0.75 sqmm shielded control cables ,pvc insulated copper armoured, controll panel for auxilaries with starters for pumps,heaters etc
RCC foundation with necessary earth work ,PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, filling and mass concrete / RCC M-30 (20 mm graded aggregate) as in foundations, Plinth beam along with necessary form work / TMT bars of 10mm dia and over cut to length bend to shape required including cranking, bending, spirally for hooping for columns, hooking ends and bidning with and including MS wire (annealed) not less than 0.9mm dia securing with clips / 10 mm thick plastering on fair faces of brick work or concrete surface in CM (1:6),even and smooth without using extra cement / Sand filling in layers around the foundation including watering and consolidation as per OEM dimensions
(l) Acoustic Enclosure as per CPCB-II Norms shall comprise of the following (i)Specially designed to meet stringent MoEF/ CPCB norms of75 dBA @ 1mtr at 75% load under free field conditions (ii)The Acoustic Enclosure as per CPCB Norms is made of CRCA sheets in Munselgreen shade and a structural/ sheet metal base framepainted in blackor any other standard colour as specified by the OEM.. (iii)High quality noise absorbant and fire-retardant gradeacoustic insulation material (P.U. Foam) complying to IS8183 designed to have optimum serviceability (iv)Air inlet louvers specially designed to operate at rated load, Made on special purpose CNC machines for consistency inquality and workmanship (v)11 tank pretreatment process and UV resistant powdercoating of all parts to withstand extreme environment, Use of special hardware for longer life, Flush styling - no projections, Fluid drains for lube oil and fuel,Fuel filling arrangement inside the enclosure
Note (i) Rate quoted shall include the necessary T&P , RCC foundation , structural works required to support the acessoriess of Dg set such asAMF panels , Exhaust mufflers and water circualtion system (ii) rate quoted includes the cost of All fuel ( high speed diesel) , lubes and collant required to carry out the no load and full load test of not less than 24 hrs as diercted by the accepting officer (iii) Rate quoted includes the cost of B check for the DG set such as replacement of lube oil, oil/ fuel filters /belts, O rings consumeables after the test run of the DG set during the warrenty period frist 300hrs/ 1 st year which ever is earlier after the date of commissioning
Supply & installation of water cooled Diesel Engine driven Prime duty Generating Set of capacity after all derating factors net of not less than 160 KVA/128 KW ,50Hz 415 volt 3 phase, 4 wire,0.8 lagg , 206 bhp 1500 RPM minimum Required Power for Rated kVA (bhp)along with AMF system with Acoustic Enclosure as per CPCB-II Norms, exhaust silencer-Hospital Grade in line including following
Engine comprising of the following: Rugged engine natural liquid cooled (EG Compleat 50:50) with radiator as secondary media with world class OEM such as Cummins/Perkins/Kohler/Greaves/Ashok Leyland Engines for powered diesel generator set Advanced in-cylinder technology turbo charged , air cooled aspriated to meet latest emission norms without any after-treatment device. Class defining technology engine is designed to meet stringent exhaust emission tests as per revised MoEF norms, thus offering environment friendly powe Compact in size with optimum power to weight ratio, 6/12, V-type , cylinder, In-line 4 stroke, radiator cooled engine Well designed air handling system with Dry type, heavy duty, replaceable paper element aircleaner with restriction indicator, Air to air aftercooling,Optimised turbocharger for increased altitudecapabilities, Best in class fuel economy with Inline fuel pump with A1 class mechanical governing, Spin on fuel filter, Standard integral set-mounted radiator system, designedand tested for 50°C ambient temperature,Full flow spin on lube oil filte,First fill of lube oil and coolant, Electrical starter motor with soft start engagement feature, Battery charging alternator,2 x 12 V DC battery/Alternator
AlternatorPMG type comprising of the following: Stamford UC/jyothi/crompton alternator frames from Technologies Brushless type, Screen protected, Revolving field, Self excited alternator conforming to IS/IEC 60034-13 Phase reconnectable winding with 12 terminals brought out for connection Dedicated winding specially designed for 3 phase operation Better motor starting capability Best in class efficiency Compact design with sealed bearings for longer life andlesser maintenance Impregnation on all wound components for bettermechanical strength ,alternator of IP 23,Voltage regulation (Max.)±1%, Class of Insulation H Class, Winding Pitch 2/3, Stator Winding Double layer lap Rotor Dynamically Balanced,Waveform distortion/ Total Harmonic Distortion No load < 1.5 %, Non distorting balanced linear load < 5 %,Maximum Unbalanced Load across phases# less than or equal to 25%, Telephonic Harmonic factor < 2% alternator capcity out put shall not be less than 160 KVA ,50Hz 415 volt 3 phase, 4 wire,0.8 lagg. 222 Amp / phase
Control Panel comprising of the following: c)Outdoor type AMF / Control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish.The control panel consists of the following parts of makes as per OEM recomendation: microprocessor based generator set monitoring and control system. AMF Functionality is inbuilt and this control includes an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration, and diagnostics, Copper bus bars with suitable capacity with incoming/outgoing terminals, Indicating lamps for ‘Load ON’ and ‘Set Running’,Instrument fuses / MCBs duly wired and ferruled, Circuit breakers of suitable rating with overload and shortcircuit protections. along with motorised change overs /on load power contactors with copper busbars, cables and protective acessories with load / bypass arrangements
Hospital grade silencer silencer suitably optimized to meet stringen noise emission standards laid down by MoEF / CPCBalong with MS supporting structures .along with thermal Insulation on horizontal pipe with Rock Conforms to IS-8183 Wool/ 100mm Thickness and 96 Kg /metric Cube density.
Controller should be compatable to the following specifications: (i) AMF Functionality controllers of Makes from the OEM : Deep Sea/ Cummins/ Wood Ward/ Com Amp (II) Intuitive operator interface which includes LED backlit 128X64 pixel graphic display with tactile feel soft-switches.Indications - Generator set, Utility Status Lamp. (iii) Remote start-stop with Engine Metering: Oil pressure, Engine temperature, Startingbattery voltage, Engine running hours (iv) AC Alternator Metering: L-L Voltage and L-N Voltage,Current (phase and total), kVA (phase and total) andFrequency. kwh, Total & per phase (kw & kVA), PF, UtilityVoltage and Freq. (v)Engine Protection: Low lube oil pressure, High/Low coolanttemperature, Battery Over/Under/Weak Volts, Fail to Crank/Start, Sensor failure, Cranking lockout, Low fuel level. (vi)AC Alternator Protection: Over/Under Voltage, Over/UnderFrequency, Loss of AC sensing. Overspeed, Over Current. (vii)Data Logging: Engine hours, Control hours and upto 5 recent fault codes (viii) Configurable glow plug control,Cycle Cranking (ix)12/24 Volt DC operation,Sleep mode,Modbus interface (RS485 RTU),InPower compatible (PC based service tool),Certifications - meets the requirement of relevant ISO, EN,Mil Std. and CE standards (x)Maintenance due alarm based on Engine Run Time and duedate,Exercisor scheduler (xi) Remote HMI , Digital electronic governor with temperture compensation and smooth starting , digital AVR for shunt of PMG excitor with Torque monitoring, Digital electronic governor with temperture compensation and smooth starting, (xii) Multifunction energy meter (Make: Schneider, L&T, El measure); three phase to Measure V, I, Hz, Kw, KVAr, KVA, PF, PA, I/E, KWH &KVArh, KVAh, Demand & Max Demand - A, Kw & KVA, etc. with inbuilt RS 485/MODBUS Card along with necessary CTs acc class 0.5 ,10 VA Aux Supply: 230 V :- 01 Sets
All pipe line connections, valves etc.required for the lube oils, fuel and cooling system
Battery & Battery charger of rated capacity as per the alternator/ Engine compatability
Mounting Arrangement shall be of the following: (i) Engine and alternator are mounted on a common MSfabricated base frame with AVM pads. (ii) Base frame with integral fuel tank is provided with drainplug, air vent, inlet and outlet connection, level indicator andprovision for cleaning
Fuel Tank of capacity 08-10 hrs running capacity along with Fuel pipe MS c class 25mm ID with bends , flanges , valves, tees and bends.
Controll / service cables shall be of 4cx 2.5 sqmm, 24 c x 2.5 sqmm , 2 c x 2.5 sqmm, and 8c x 0.75 sqmm shielded control cables ,pvc insulated copper armoured, controll panel for auxilaries with starters for pumps,heaters etc
RCC foundation with necessary earth work ,PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, filling and mass concrete / RCC M-30 (20 mm graded aggregate) as in foundations, Plinth beam along with necessary form work / TMT bars of 10mm dia and over cut to length bend to shape required including cranking, bending, spirally for hooping for columns, hooking ends and bidning with and including MS wire (annealed) not less than 0.9mm dia securing with clips / 10 mm thick plastering on fair faces of brick work or concrete surface in CM (1:6),even and smooth without using extra cement / Sand filling in layers around the foundation including watering and consolidation as per OEM dimensions
(l) Acoustic Enclosure as per CPCB-II Norms shall comprise of the following (i)Specially designed to meet stringent MoEF/ CPCB norms of75 dBA @ 1mtr at 75% load under free field conditions (ii)The Acoustic Enclosure as per CPCB Norms is made of CRCA sheets in Munselgreen shade and a structural/ sheet metal base framepainted in blackor any other standard colour as specified by the OEM.. (iii)High quality noise absorbant and fire-retardant gradeacoustic insulation material (P.U. Foam) complying to IS8183 designed to have optimum serviceability (iv)Air inlet louvers specially designed to operate at rated load, Made on special purpose CNC machines for consistency inquality and workmanship (v)11 tank pretreatment process and UV resistant powdercoating of all parts to withstand extreme environment, Use of special hardware for longer life, Flush styling - no projections, Fluid drains for lube oil and fuel,Fuel filling arrangement inside the enclosure
Note (i) Rate quoted shall include the necessary T&P , RCC foundation , structural works required to support the acessoriess of Dg set such asAMF panels , Exhaust mufflers and water circualtion system (ii) rate quoted includes the cost of All fuel ( high speed diesel) , lubes and collant required to carry out the no load and full load test of not less than 24 hrs as diercted by the accepting officer (iii) Rate quoted includes the cost of B check for the DG set such as replacement of lube oil, oil/ fuel filters /belts, O rings consumeables after the test run of the DG set during the warrenty period frist 300hrs/ 1 st year which ever is earlier after the date of commissioning
M &L in replacement of Earthing complete with copper plate electrode 600x600x3.15mm thick electrode and 20×3mm copper strip as earthing lead buried directly in ground (earth pit not less than 2.25 m deep below normal grond level) with top edge of the plate not less than 1.5 m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron electric arc welding all joints all as specified and shown in electrical plate no 3 of SSR Part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with PCC 1:2:4 type B140 mm thick cover with MS rod 8 mm dia 150 mm long reinforcement, watering funnel. 25 mm dia medium grade for protection of earth electrode 20 mm dia for watering complete all as specified and directed and tested on completion (Note :- Copper strip 20 x 3 mm upto 7.5 mtr included in quote rate)
M&L for fixing copper strip 20x3 mm with saddle and rfixing screw etc complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc,complete using ERW or induction butt welded tubes ,including one coat of zinck chromate primer paint including prepration of surface at contractor's workshop before fabrication complete allas specified and directed.
M&Lgalvanised sheet 0.50 mm thick power pre coated in roof fixed with 'L' type or 'J' type or cranked hooked bolt complete all as specified and directed
S&Laying reinforcement precast cable cover class LV Type-1 Flat size 250x150x40mm laid in trenches for cable protection etc complete all as directed
M&L PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L removal / disconnecting all electrical and mechanical / fuel pipe line connections , dismantelling with out damaging the installation permisess wall/floors and complete shifting of BER DG set with fuel tank and acessories from certain units to MT yard under Delhi cantt complete all as specified and directed.
M/s JAIMAA ASSOCIATES
Leo Air and Power Solution pvt Ltd.
Ridhi engineers and builders
Vijay Electricals
Global Enterprises
MV Engineers And Contractors
AMIT ASSOCIATES
M/S Parshant Associates
Bidder Name
AMIT ASSOCIATES
Global Enterprises
Vijay Electricals
mayur enterprises
MV Engineers And Contractors
M/S Parshant Associates
M/s JAIMAA ASSOCIATES
Ridhi engineers and builders
Leo Air and Power Solution pvt Ltd.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .