Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical VILL P O NARIT P S AMTA DIST HOWRAH PIN 711413 | HOWRAH | WEST BENGAL | 711413 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical 31 1 6 SEBADAL ROAD UDAYPUR NIMTA KOLKATA 49 | 24 PARAGANAS NORTH | WEST BENGAL | 700049 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical 28 SAMBHU BABU LANE KOLKATA 700014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical 3 C DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | Admitted-Fee/PreQual/Technical |
Tender Value
₹50.0 L
EMD Value
₹99,986
Closing Date
20 Jul 2026, 1:00 pmClosed
EE-II KNHED PWDte.
OFFICE OF THE EXECUTIVE ENGINEER Kolkata North Health Electrical Division, P.W.Dte. KIT Building Annex, 4thFloor,P-16, India Exch. Place Extn., Kolkata700073
Electrical repairing and renovation work due to distressed concrete work of civil department at C.B. Building within the premises of Medical College Hospital, Kolkata.
2026_WBPWD_5016097_1
WBPWD/EE-II/KNHED/NIQ-17/ 2026-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
Kolkata
Please refer Tender documents.
6 documents required · 6 mandatory
₹99,986
OFFICE OF THE EE KNHED PWDte.
20 Aug 2026
29 Jun 2026
22 Jul 2026
29 Jun 2026
20 Jul 2026
6 Jul 2026
3 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | PART - A - E.I WORK
Dismantling the existing E.I. work by Co's own tools & tackles and take unnecessary items away from site by maintening normalcy as far as possible as per direction of EIC . | 1 | Item | - | - |
| 2 | Point Wiring :
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (make-- RR Cable/ polycab/KEI/Gloster/Havells) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish
a)Average run 12 mtr | 350 | Pt | - | - |
| 2.1 | b) Average run 10 Mtr | 250 | Pt | - | - |
| 3 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (make-- RR Cable/ polycab/KEI/Gloster/Havells) in 20mm size PVC rigid conduit 'FR'(Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish
On Board | 180 | Pt | - | - |
| 4 | Distribution Box:
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as per GS ( Make - Legrand/ABB ITUS/LK/Siemens )
8 Way ( Up to 160 A ) | 12 | Set | - | - |
| 5Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS ( Make - Legrand/ABB ITUS/LK/Siemens ) 160 A FP | |||||
| 6Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connections per GS ( Make - Legrand/ABB ITUS/LK/Siemens ) 63 TP | |||||
| 7 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment ( Make - Legrand/ABB ITUS/LK/Siemens )
6 Way | 24 | Each | - | - |
| 8Supplying and fixing 63A 415 V MCB Isolator on din rail of existing DBs and necessary connection ( Make - Legrand/ABB ITUS/LK/Siemens ) | |||||
| 9Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection ( Make - Legrand/ABB ITUS/LK/Siemens ) 6 - 32A SP MCB | |||||
stage.html
html • 0.03 MB
tech_bid_open.pdf
cancelled_1.pdf
pdf • 0.44 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
2911.pdf
Tender Documents • 1.46 MB
suspension.pdf
Additional Documents • 2.91 MB
BOQ_5085319.xls
BOQ • 0.62 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .