Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.9 LAccepted-Finance 192 RAJAMMAL BUSINESS CENTRE 3RD CROSS BRINDAVAN STREET SRINIVASA NAGAR MADURA PUZHUTHIVAKKAM MADIPAKKAM CHENNAI KANCHIPURAM TAMIL NADU 600091 | CHENNAI | TAMIL NADU | 600091 | L1 | Accepted-Finance ACCEPTED | |
| 2 | L2₹82.0 L+₹7.1 L (9.44%)Accepted-Finance NEW NO 5A OLD NO 80 53RD STREET ASHOK NAGAR CHENNAI TAMIL NADU 600083 | CHENNAI | TAMIL NADU | 600083 | L2 | Accepted-Finance ACCEPTED | |
| 3 | L3₹84.2 L+₹9.3 L (12.4%)Accepted-Finance NO 243 D TNHB 4TH STREET KORATTUR TIRUVALLUR TAMIL NADU 600080 | 600080 | L3 | Accepted-Finance ACCEPTED |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
2 Mar 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Managing Director
Ticel Bioaprk Ltd 5, CSIR Road Taramani Chennai 600 113
HVAC and Electrical Works
2026_LBPL_656955_1
TICEL-III/ELE/2025-26/13
Open Tender
Electrical Works
Item Rate
Biopark-III at Coimbatore
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹50,000
At Biopark-III Coimbatore
25 Mar 2026
14 Feb 2026
3 Mar 2026
14 Feb 2026
2 Mar 2026
25 Feb 2026
23 Feb 2026
HVAC WORKS
CEILING SUSPENDED AIR HANDLING UNITS - CLASSIFIED AHU - GRADE D & GRADE C: Supply, installation, testing, and commissioning of ceiling-suspended sandwich-type double-skin Air Handling Units (AHUs) with high-density PUF insulation (40 ± 2 kg/m³) and sheet thickness of 0.8 mm, complete with direct-driven plug-type blowers. The AHU shall consist of a blower section, thermal break profile, unit base frame, inlet plenum section, and outlet plenum section. Filtration shall comprise G-4 pre-filters (1 micron), F-7 fine filters (3 microns), and F-9 semi-HEPA filters (0.3 micron). The air velocity across the filters shall not exceed 450 FPM. A dual-coil arrangement shall be provided, consisting of one DX coil and one chilled water coil, complete with all required accessories and safety provisions. The AHU shall be provided with very low leakage aluminium dampers, including Supply Air, Return Air, Fresh Air, and Exhaust Air dampers, along with vibration isolation pads (VI pads), access doors across each section as per approved design, drive set with coupling guard, vibration isolators, internal lights, limit switches, and necessary instruments. IE-3 efficiency motors suitable for VFD operation and Variable Frequency Drives (VFDs) shall be provided Units shall be supplied complete as per approved specifications, schedule of equipment, airflow diagram, and AHU schematic drawings. G-4 washable filters shall be provided at the fresh air mouthpiece, and F-7 filters shall be provided for bleed air, complete with SS perforated sheets and dampers, for all AHUs. 1. Wrapping of the AHU with plastic sheets and covering of the Fresh Air (FA), Supply Air, and Exhaust Air dampers shall be carried out to avoid damage to the AHUs by other agencies. 2. AHU leakage testing shall be performed before handing over the unit to other agencies for manifold and ducting works. 3. During start-up and commissioning, proper cloth shall be provided for blow-down of the AHU, which shall be within the vendor’s scope. 4. RPM check shall be carried out. 5. Vibration and noise levels shall be checked and recorded. 6. Static pressure across each section shall be checked. 7. AHU airflow (CFM) by traverse method shall be checked at the AHU mouthpiece ducting. 8. Identification for each section and AHU equipment code, including filter coding for each filter and all filter grades, shall be carried out. A3-size AFD shall be stickered inside the AHU with proper labeling as per the Client’s coding protocol. All related cost and scope shall be considered. 9. All test certificates and O&M manuals shall be provided at the time of material delivery at site. Cable entry holes shall be provided with ROTEX grommets only; site-made holes shall not be acceptable. No screwing or supporting inside the AHU for electrical and BMS cabling shall be carried out by other vendors. Units shall be complete as per specifications, schedule of equipment, air flow diagram, and schematic drawings. Only the MS powder-coated junction box with rigid connection shall be in the scope of the AHU vendor, whereas the MS box shall be provided by the HVAC vendor. AHU incoming cables shall be terminated at the junction box, and all internal cabling shall be within the AHU vendor’s scope
AHU- 02 , Capacity -4200 CFM ,Supply Blower Static Pressure- 150 mm of WC
AHU- 03 , Capacity -8400 CFM ,Supply Blower Static Pressure- 150 mm of WC
HEPA FILTERS
Hooded Hepa Fileter: Supply and installation, testing and commissioning of walkable ceiling-mounted minipleat compact HEPA (H-14) filter (high-capacity HEPA filters) diffuser hooded type with protection mesh and laminator, as per specifications. All nuts, bolts, screws, and ports (PAO and pressure measurement: 40 mm dia) shall be of SS. The arrangement shall be leakproof with proper sealing and food-grade gasket arrangement. Special fire-resistant food-grade flexible connectors shall be provided between the duct and filter (price of flexible connector to be quoted separately). Provisio shall be made for installing sensors, duly flushed with the false ceiling (close coordination with the false ceiling vendor is required). Any frame, fittings, and supports required for installation of the filter in the false ceiling shall be included and completed as per specifications. The casing shall have arrangements/ports for PAO charging and pressure measurement from both the top and bottom of the false ceiling. The vendor shall submit GA fixing arrangement drawings and samples for approval before manufacturing. PAO testing of HEPA filters shall be included. Mock-up approval of the HEPA housing is required prior to manufacturing clearance. Identification stickering shall be done as per Client protocol and requirements. Prices shall be inclusive of all testing as specified.
610 mm x 610 mm x 175 mm (1000CFM)
450 mm x 450mm x 175 mm (545 CFM)
305 mm x 305 mm x 175 mm (250 CMH)
SHEET METAL WORKS
Supply, installation, testing, and commissioning of factory-fabricated GI sheet metal ducting constructed using standard TDF (Transverse Duct Flange) system, complete with matched TDF flanges, corner cleats, proper nut-and-bolt fasteners, 5–6 mm thick food-grade gaskets, double-skin access doors, and all necessary supports, nuts, and bolts. The duct supporting system shall comprise MS angle supports with GI coating, including threaded rods, Hilti anchors, and all associated fixing accessories. Corner cut pieces and supports shall be suitably painted. All works shall be carried out strictly as per specifications and in accordance with approved drawings Note: Duct leakage testing shall be carried out as per SMACNA standards using an online duct pressure testing machine with valid calibration certification. All duct openings shall be properly plastic-wrapped; open ducting found at site shall be rejected as it is against quality requirements. Ducting shall be properly stacked and covered at site accordingly. SAD/RAD and FAD radium stickering shall be done as per Client protocol and requirements. The ducting shall be designed and constructed to withstand pressures of 500 Pascal and 1000 Pascal, as applicable.
Supply, installation, testing, and commissioning of Site-fabricated GI sheet metal ducting constructed using standard TDF (Transverse Duct Flange) system, complete with matched TDF flanges, corner cleats, proper nut-and-bolt fasteners, 5–6 mm thick food-grade gaskets, double-skin access doors, and all necessary supports, nuts, and bolts. The duct supporting system shall comprise MS angle supports with GI coating, including threaded rods, Hilti anchors, and all associated fixing accessories. Corner cut pieces and supports shall be suitably painted. All works shall be carried out strictly as per specifications and in accordance with approved drawings Note: Duct leakage testing shall be carried out as per SMACNA standards using an online duct pressure testing machine with valid calibration certification. All duct openings shall be properly plastic-wrapped; open ducting found at site shall be rejected as it is against quality requirements. Ducting shall be properly stacked and covered at site accordingly. SAD/RAD and FAD radium stickering shall be done as per Client protocol and requirements. The ducting shall be designed and constructed to withstand pressures of 500 Pascal and 1000 Pascal, as applicable.
Supply /Return Air Diffusers : Supply, installation, testing, and commissioning of ceiling-mounted supply and return air grilles made of extruded aluminium sections, complete with extruded aluminium volume control dampers and mounting frames, as required. Identification stickering shall be done as per Client protocol and requirements.
Supply, installation, testing, and commissioning of fresh air and exhaust air louvers made of extruded aluminium, complete with HDPE insect mesh, G4 pre-filters with installation arrangement/frame (filters shall be flange type with nut-and-bolt fixing), and mounting frames as required. (For AHU room louvers) Identification stickering shall be done as per Client protocol and requirements.
Very low leakage type volume control damper made of extruded aluminium with gaskets on the blades. The damper shall be provided with operating handles, locking arrangements, calibration scale, and shall also be suitable for motorized operation.
1.6 mm thick GSS powder-coated return air perforated grilles with 60–70% clear area, complete with hidden screw/bolt arrangements and mounting frames as required, and properly flushed with modular wall panels or false ceilings.
MS support and structural work, including all welding, nut-and-bolting, epoxy painting, and accessories.
Thermal Insulation: Supply, installation, testing, and commissioning of aluminium foil–faced closed-cell nitrile rubber / polyolefin foam insulation on SA ducts, RA ducts, and RA risers, complete with adhesive, as per specifications (all corners shall be sealed with 4" wide self-adhesive aluminium foil tape). The insulation material shall be closed-cell elastomeric nitrile rubber with aluminium foil laminated on one side. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C, as per EN 12667. The moisture diffusion resistance factor (µ value) of the insulation material shall be a minimum of 12,000 without any external barrier, as per EN 12086. The insulation material shall have fire performance such that it passes Class 1 as per BS 476 Part 7 for surface spread of flame and also passes the fire propagation requirement as per BS 476 Part 6, meeting the Class ‘O’ fire category as per the 1991 Building Regulations (England & Wales) and the Building Standards (Scotland) Regulations 1990. The density of the insulation material shall be between 40 and 60 kg/m³. The insulation material shall be dust- and fibre-free. The insulation material shall withstand a maximum surface temperature of +85°C and a minimum surface temperature of 0°C, as per EN 14706. The aluminium foil shall be 12-micron thick with reinforced glass scrim, with a weight of 70 gsm as per EN 22286. The tensile strength shall be 250 N/50 mm as per ISO 527-3, with elongation of 4% as per DIN 53354.The material shall have zero ODP (Ozone Depletion Potential) and zero GWP (Global Warming Potential).
SA duct (13 mm thick)
RA duct (9 mm thick)
CHILLED WATER MANIFOLD AND PIPING: Supply, installation, testing, and commissioning of chilled water manifold comprising 5 Nos. isolation valves (butterfly valves with extended stem for sizes above 50 mm and ball valves with extended stem for sizes up to 50 mm), Y-strainer, and PIBCV (pressure independent balancing & control valve) with actuators and thermostat. The PIBCV shall be supplied under BMS scope, while installation shall be under this scope. The scope includes MS piping as per specification up to 15 running meters length, complete with all necessary SORF flanges, nuts, bolts, double washers, asbestos-free gaskets, and MS supports with PUF blocks as per specification. Painting shall be carried out as per project requirements. Provision shall be made for: Test points with 15 NB ball valve and SS thermowell suitable for pipe size, temperature range 0–50°C, on both supply and return connections of the manifold. 15 NB / 25 NB drain valves on supply and return lines. 15 NB / 25 NB automatic air vents with isolation valves on supply and return connections. 2 Nos. pressure gauge (PG) provisions with 15/20 NB ball valves for supply and return line pressure gauge installation. 2 Nos. temperature gauges with thermowell and 15/20 mm ball valves for temperature gauge provision. 2 Nos. 15/20 mm drain valves on supply and return lines for draining purposes. The manifold shall be insulated with Class ‘O’ physically / chemically cross-linked XLPE insulation with factory-applied reinforced aluminium foil over the pipe section for both supply and return lines, including valve boxing, etc. The manifold scope shall be up to the header only. Additionally, the drain pipe with U-trap shall be provided as per AHU static pressure, using GI piping, and shall be insulated accordingly. Notes: The vendor shall submit technical data sheets for all valves, strainers, pipes, etc., for approval prior to ordering. Welding of chilled water piping to the manifold counter flange shall be considered in the scope.
65 mm dia
50 mm dia
Documentation: Execution and documentation – commissioning test protocol for non-GMP units, and DQ, IQ, and OQ for the qualified units, with area validation carried out accordingly.
Validation: Providing protocols and execution of URS compliance, Risk Assessment, DQ, IQ, and OQ, including testing, commissioning, and validation of all units and cleanroom areas, with the following: 1. AHU traverse check 2. Air balancing, including supply and return ducting and units 3. Filter velocity check 4. HEPA PAO integrity test 5. Pressure balancing 6. Particle count 7. Temperature mapping for 3 days using 21 CFR-compliant data loggers for both temperature and relative humidity for all critical rooms. Data loggers shall be considered as per the protocol for loading and unloading over 7 days 8. Recovery test 9. Airflow pattern verification with video recording, etc. Support for PQ will be required.
ELECTRICAL WORKS
LT SWITCHGEAR & ISOLATORS: Supply, installation, testing and commissioning of Low voltage switchgear's, free standing, Cubical type, dead front, Frame and Doors:2mm, Internal Partations:1.6mm thick, Gland Plates:3mm Thick, powder coated (Paint Shade: RAL 7032/7035), indoor type with vermin proof hinged lockable doors for each compartment, bus bar interconnections for incoming and outgoing including feeders earthing and painting and as per specifications comprising of ACB,MCCB and MCB horizontal and vertical aluminum bus bar, earth bus bar as per SLD. All meters shall be digital with LED display, whereever mentioned and shall have RS 485 Modbus RTU half duplex communication interface for provision of BMS connectivity and wired accordingly. Provide required NO/NC potential free contacts wires and terminal blocks in the cable alley for BMS operation (Optional).The swtichboards are to be tested as per IS 8623 -1977 specifications. The busbars are of high conductivity Al. alloy E91E IS 5082 specification and cable entries will be from either top or bottom depending on location. LT Switchgear shall be as per technical specification and single line diagram
Incomer: 2 Nos. 320A / 25 KA, 4P, MCCB with ICS breaking capacity, MP based MCCB, O/L, S/C protection with an arrangement for cable connection on one side & bus-bars connection on other side.With Mechanical Interlock
2 Nos. 320A / 25 KA, 4P, MCCB with ICS breaking capacity, MP based MCCB, O/L, S/C protection with an arrangement for cable connection on one side & bus-bars connection on other side.With Mechanical Interlock
Metering & indications
3 Sets of R,Y,B phase indicating lights (LED-TYPE) for Incomer 1 and Incomer 2
3 Sets of indicating lights (LED-TYPE) - ON/OFF/TRIP for Incomer 1 and Incomer 2
2 Nos of Voltmeter (0-500V)
1 Sets of 3 phase, 4 wire, 320/5A, Digital flush type Class-I accuracy Dual Source Energy meter with dual tariff metering facility along with RS 485 Port. Price shall be inclusive of necessary external contactor.(2 nos)
1 set of 3 Nos. 320/5A, Class-I, 5VA burden moulded CT's with necessary CT terminals in compartments.(2 nos)
2 Nos of 25kA TVSS Protection and ELR with CBCT (0-8 Amp based)
BusCoupler
1Nos. 320A / 25 KA, 4P, MCCB with ICS breaking capacity, MP based MCCB, O/L, S/C protection with an arrangement for cable connection on one side & bus-bars connection on other side.
BUS BARS
1 sets of 320A TPN Alu. bus bars, (Neutral 50%) ,415V, 25KA for 1 Sec Electrolytic grade Alu. bus bars with PVC insulated heat shrinkable colour coded sleeves mounted on SMC supports. Current density shall not be more than 0.8 /Sqmm for Alu and 1.6 Amp. / Sq.mm for Copper
Outgoings
Bus Section-1
2 Nos. 250A , 4P, 25KA ,MCCB
2 Nos.63A, 4P, 10KA,C-Curve, MCB
1 Nos.25A, 4P, 10KA,C-Curve, MCB
2 Nos.25A, DP, 10KA,C-Curve, MCB
1 Nos.63A, DP, 10KA,C-Curve, MCB
Bus Section-2
14 Nos.20A, 4P, 10KA,C-Curve, MCB
4 Nos.25A, 4P, 10KA,C-Curve, MCB
3 Nos.40A, 4P, 10KA,C-Curve, MCB
3 Nos.63A, 4P, 10KA,C-Curve, MCB
1 Nos. 125A , 4P, 25KA ,MCCB
Refer SLD and Technical Specifcations
SMDB (COST FOR THE ABOVE LT SWITCHGEAR & ISOLATORS)
UTILITY PANEL
Incomer
1 Nos. 250A / 25 KA, 4P, MCCB with ICS breaking capacity, MP based MCCB, O/L, S/C protection with an arrangement for cable connection on one side & bus-bars connection on other side.
Metering & indications
3 Sets of R,Y,B phase indicating lights (LED-TYPE) for Incomer 1
3 Sets of indicating lights (LED-TYPE) - ON/OFF/TRIP for Incomer 1
1 Nos of Voltmeter (0-500V)
1 Sets of 3 phase, 4 wire, 250/5A, Digital flush type Class-I accuracy Dual Source Energy meter with dual tariff metering facility along with RS 485 Port. Price shall be inclusive of necessary external contactor.
1 set of 3 Nos. 250/5A, Class-I, 5VA burden moulded CT's with necessary CT terminals in compartments.
1 Nos of 25kA TVSS Protection and ELR with CBCT (0-8 Amp based)
BUS BARS
1 sets of 250A TPN Alu. bus bars, (Neutral 50%) ,415V, 25KA for 1 Sec Electrolytic grade Alu. bus bars with PVC insulated heat shrinkable colour coded sleeves mounted on SMC supports. Current density shall not be more than 0.8 /Sqmm for Alu and 1.6 Amp. / Sq.mm for Copper
Outgoings
2 Nos.200A,4P, 25KA,MCCB
2 Nos.40A,4P, 25KA,MCCB
2 Nos.20A, 4P, 10KA,C-Curve, MCB
2 Nos.25A, 4P, 10KA,C-Curve, MCB
2 Nos.63A, 4P, 10KA,C-Curve, MCB
Refer SLD and Technical Specifcations (COST FOR THE ABOVE UTILITY PANEL)
1 Nos. 200A / 25 KA, 4P, MCCB with ICS breaking capacity, TH based MCCB, O/L, S/C protection with an arrangement for cable connection on one side & bus-bars connection on other side.
ISOLATORS
63A 4P MCB Isolator in metallic enclosure -IP 65
40A 4P MCB Isolator in metallic enclosure -IP 65
63A 4P MCB in metallic enclosure -IP 42
25A DP MCB in metallic enclosure -IP 42
MCB DISTRIBUTION BOARDS
12 Way 7 SEGMENT MCB Distribution Board - PDB,MCB DB comprising the following, Type of DB - 12 way 7 SEGMENT MCB DB (Double Door), 63A 4P MCB - 1 No. as incomer, 40A DP RCCB, 30mA, 2 Module - 3 Nos. as Sub incomer per phase, 16A SP MCB, 10 kA - 36Nos. as outgoings : MCB are of 'C' Curve, The rate shall include providing Cu. bus barsinterconnection, separate earth bus, separate neutral bus for each phases, Blank Plates and incluuding necessary connected civil works like chipping, rough plastering etc.
12 Way VTPN MCCB Distribution Board: MCCB DB comprising the following Type of DB - 12 way VTPN MCCB DB (Double Door), 125A TPN MCCB - 1 No. as incomer, 20A TP MCB, 10 kA - 2 Nos. as outgoings : MCB are of 'C' Curve, 25A TP MCB, 10 kA - 3 Nos. as outgoings : MCB are of 'C' Curve, 40A TP MCB, 10 kA - 3 Nos. as outgoings : MCB are of 'C' Curve, 63A TP MCB, 10 kA - 2 Nos. as outgoings : MCB are of 'C' Curve, 20A SP MCB, 10 kA - 6 Nos. as outgoings : MCB are of 'C' Curve, The rate shall include providing Cu. bus barsinterconnection, separate earth bus, separate neutral bus for each phases, Blank Plates and incluuding necessary connected civil works like chipping, rough plastering etc.
12 Way SPN MCB Distribution Board - LDB, MCB DB comprising the following Type of DB - 12 way SPN MCB DB (Single Door), 25A DP 30 mA RCBO, 2 Module - 1 No. as incomer, 6A SP MCB, 10 kA - 10 Nos. as outgoings : MCB are of 'C' Curve, The rate shall include providing Cu. bus barsinterconnection, separate earth bus, separate neutral bus for each phases, Blank Plates and incluuding necessary connected civil works like chipping, rough plastering etc.
12 Way SPN MCB Distribution Board - ELDB, MCB DB comprising the following, Type of DB - 12 way SPN MCB DB (Single Door), 25A DP 30 mA RCBO, 2 Module - 1 No. as incomer , 6A SP MCB, 10 kA - 10 Nos. as outgoings : MCB are of 'C' Curve, The rate shall include providing Cu. bus barsinterconnection, separate earth bus, separate neutral bus for each phases, Blank Plates and incluuding necessary connected civil works like chipping, rough plastering etc.
12 Way SPN MCB Distribution Board - UDB: MCB DB comprising the following, Type of DB - 12 way SPN MCB DB (Single Door), 20A DP 30mA RCBO, 2 Module - 1 No. as incomer, 10A SP MCB, 10 kA - 10 Nos. as outgoings : MCB are of 'D' Curve, The rate shall include providing Cu. bus barsinterconnection, separate earth bus, separate neutral bus for each phases, Blank Plates and incluuding necessary connected civil works like chipping, rough plastering etc.
LOW VOLTAGE CABLES AND END TERMINATION: Supply and laying of 1100 V grade, XLPE insulated,extruded PVC Inner Sheathed and extruded FRLS-PVC Outer sheatehed , aluminium conductor, Armoured power cable as per specifications. The cable shall be laid in indoor trenches / cable trays as required. The cable shall be clamped at regular intervals to the suppoprts in trench or to cable trays or brick wall using MS clamps and fasteners. Rate shall exclude the cost of cable trays and termination in this item. NOTE: Cables will not be procured based on BOQ only. True measurements will be taken by Contractor before ordering, based on Drawings.
3.5CX 150 Sqmm Alu.arm Cable
3.5CX 120 Sqmm Alu.arm Cable
3.5CX 95 Sqmm Alu.arm Cable
3.5CX 70 Sqmm Alu.arm Cable
4.0CX 25 Sqmm Alu.arm Cable
4CX 16 Sqmm Alu.arm Cable
4CX 10 Sqmm Alu.arm Cable
Low Voltage Copper Conductor Cables: Supply and laying of 1100 V grade, XLPE insulated,extruded PVC Inner Sheathed and extruded FRLS-PVC Outer sheatehed copper conductor, Armoured/Un armoured power cable as per specifications. The cable shall be laid in indoor trenches / cable trays as required. The cable shall be clamped at regular intervals to the suppoprts in trench or to cable trays or brick wall using MS clamps and fasteners. Rate shall exclude the cost of cable trays and termination in this item.
4Cx 16sqmm Armoured Copper Cable
4Cx 10sqmm Armoured Copper Cable
4Cx 6sqmm Armoured Copper Cable
4Cx 4sqmm Armoured Copper Cable
3Cx 6sqmm Armoured Copper. Cable
3Cx 4sqmm Armoured Copper Cable
3Cx 2.5sqmm Armoured Copper Cable
Supply and laying 3Cx6sqmm Copper Flexible Cable
LOW VOLTAGE CABLE END TERMINATION: Supply and providing LV cable end termination for below listed cable with copper lugs, brass cable glands, tapping, crimping, etc. complete.sIngle Compression Glands : Cable Size Below 150 Sqmm ,Double Compression Glands : Cable size above 185sqmm and Single core cables 400sqmm and above
3.5CX 150 Sqmm Alu.arm Cable
3.5CX 120 Sqmm Alu.arm Cable
3.5CX 95 Sqmm Alu.arm Cable
3.5CX 70 Sqmm Alu.arm Cable
3.5CX 25Sqmm Alu.arm Cable
4CX 16Sqmm Alu.arm Cable
4CX 10Sqmm Alu.arm Cable
LOW VOLTAGE CABLE END TERMINATION: Supply and providing LV cable end termination for below listed cable with copper lugs, brass cable glands, tapping, crimping, etc. complete.sIngle Compression Glands : Cable Size Below 150 Sqmm ,Double Compression Glands : Cable size above 185sqmm and Single core cables 400sqmm and above
4Cx 16sqmm Cu Arm Cable
4Cx 10sqmm Cu Arm Cable
4Cx 6sqmm Cu Arm Cable
4Cx 4sqmm Cu Arm Cable
3Cx 6sqmm Cu Arm. Cable
3Cx 4sqmm Cu Arm. Cable
3Cx 2.5sqmm Cu Arm. Cable
3Cx6sqmm Cu Flexible Cable
SWITCHES AND SOCKETS: Supply and install switches and Sockets System as required according to the specification, drawings and design. The installation rate of all the following accessories shall include for the supply of all materials such as passivated metal switchbox,junction boxes, switch plate, switches, conduit accessories, wires, tags, supports, fittings fixings and the like, to form complete elements and shall include for earthing the switchboxes The installation rate shall include for termination of all cables and wires into the devices, testing,commissioning and setting to work as required by the specifications. Power Receptacles with Box
Supply, installation, testing and Commissioning of 1 x 6/16A, universal socket controlled with 1 x 16A Switch including interconnection etc., complete.The sockets shall be with face plate, GI BOX with accessories.Rate shall include the cost for fixing of back box with plastering and rough finish
Supply, installation, testing and Commissioning of 1 x 6A, universal socket controlled with 1 x 6A Switch including interconnection etc., complete.The sockets shall be with face plate, GI BOX with accessories.Rate shall include the cost for fixing of back box with plastering and rough finish
Supply, installation, testing and Commissioning of 2 x 6/16A,, universal socket controlled with 2 x 16A Switch including interconnection etc., complete.The sockets shall be with face plate, GI BOX with accessories.Rate shall include the cost for fixing of back box with plastering and rough finish
Supply, installation, testing and Commissioning of 3 x 6A, universal socket controlled with 1 x 16A Switch including interconnection etc., complete.The sockets shall be with face plate, GI BOX with accessories. Rate shall include the cost for fixing of back box with plastering and rough finish
Power Receptacles without Box
Supply, Installation testing and commissioning of 3 nos. of 6 A, multi Pin Universal socket controlled by 1 no. 16 A common switch along with face plate, raceway mounted and other necessary accessories to complete the installation.
Supply, Installation testing and commissioning of 2 nos. of 6 A, multi Pin Universal socket controlled by 1 no. 16 A common switch along with face plate, raceway mounted and other necessary accessories to complete the installation.
Industrial Sockets : (IP-44)
Supply, installation, testing and Commissioning of 16A, 1 phase Industrial Plug & Socket controlled with 16A DP MCB in a enclosure with all accessories.
Supply, installation, testing and Commissioning of 20A, 1 phase Industrial Plug & Socket controlled with 20A DP MCB in a enclosure with all accessories.
Supply, installation, testing and Commissioning of 25A, 1 phase Industrial Plug & Socket controlled with 25A DP MCB in enclosure with all accessories.
Supply, installation, testing and Commissioning of 25A, 3 phase Industrial Plug & Socket controlled with 25A 4P MCB in enclosure with all accessories.
Supply, installation, testing and Commissioning of 32A, 3 phase Industrial Plug & Socket controlled with 32A 4P MCB in enclosure with all accessories.
Supply and installation of 3 Module Metal Boxes
Supply and installation of 4 Module Metal Boxes
Supply and installation of 6 Module Metal Boxes
Supply and fixing of Blankplates
Supply and fixing of 3 Pin Plug top suitable for 16/20A
CIRCUIT MAIN FOR LIGHTING/POWER :
3 core 1.5 sqmm Double Insulated Copper copper conductor flexible cable with FRLS Sheathing in the existing raceways/conduits. Rate shall exclude the cost of Raceway/Conduit in this items.(Exit Signage)
3 core 2.5 sqmm Double Insulated Copper copper conductor flexible cable with FRLS Sheathing in the existing raceways/conduits. Rate shall exclude the cost of Raceway/conduit in this items.
3 core 4 sqmm Double Insulated Copper copper conductor flexible cable with FRLS Sheathing in the existing raceways/conduit. Rate shall exclude the cost of Raceway/conduit in this items.
2R x 2.5 sq.mm. + 1R 1.5 sq mm FRLS, MSCC wires drawn in 25mm Dia PVC conduit with all accessories for general lighting.The rate shall include the cost of conduits and its accessories .
2R x 4sqmm and 1RX2.5Sqmm FRLS MSCC wires drawn in 25mm dia PVC conduit with all accessories for general purpose power sockets.The rate shall include the cost of conduits and its accessories.
POINT WIRING
PRIMARY LIGHT POINT (Switch Control): Primary light point means wiring from first switch control to the first light outlet. The switch and all necessary accessories would be part of primary point.'. Not to include the incoming lighting circuit from MCB-DB to switch.' But to include the sub-circuit if it is drawn from adjacent switch box. Ceiling flexible conduit shall be included at the drop of light fixture.
SECONDARY LIGHT POINT (Switch Control): Secondary light point means extention of light outlet from existing primary point. Same to be controlled by the existing switch of primary point. Ceiling flexible conduit shall be included at the drop of light fixture.
Supply and providing MS Perforated cable trays factory fabricated out of 2mm thick sheet steel, channel size 50 mm supporting angle frame at every 1.8 m, bottom angle fasteners, anchor grip bolts, synthetic enamelled painting, etc. The tray shall be suspended from ceiling using anchor bolt and angle iron supports or mounted from wall. The rate shall include all accessories like bends, elbows, tees, coupler plates, etc., which will be measured as linear measurement and fixing accessories.The rate shall include the cost of Supports
50 mm wide 50 mm height
100 mm wide 50 mm height
150 mm wide 50 mm height
200 mm wide 50 mm height
300 mm wide 50 mm height
Supply and installation of Race ways of following sizes. a). Ceiling raceway's made of of 1.6 mm thick Powder Coated GI with 1.2 mm thick screwed / Push to fit type cover. The cost shall include required GI supporting materials as per standards/final GFC drawings. b).Floor raceway's made of of 1.6 mm thick GI sheet.The covers shall be 2.0mm thick for the raceways. The raceway thickness shall be considered as per manufacturer standards based on the width of raceway trays.The race ways shall be suitable for installation in above false ceiling / open ceiling areas.
CEILING RACE WAY (Eelctrical /IT/AV) 200mm x 50mm
CEILING RACE WAY (Eelctrical /IT/AV) 150mm x 50mm
CEILING RACE WAY (Eelctrical /IT/AV) 100mm x 50mm
FLOOR RACE WAY FOR (Eelctrical /IT/AV) 75mm x 40mm
FLOOR RACE WAY FOR (Eelctrical /IT/AV) 50mm x 40mm
FLOOR JUNCTION BOXES 85mm x 85mm x 50mm
FLOOR JUNCTION BOXES 60mm x 60mm x 50mm
Earthing
Supply and Installation of earthing station as per IS3043 complete with 600x600x3.15mm Copper plate earthing with salt, charcoal, 2 nos. of 25x3mm Copper strip up to test link,19mm dia GI watering pipe with funnel, test link earthing chamber 450x450mm CI cover etc with required civil works complete. The CI Frame and cover shall be of heavy duty type.
Supply and Installation of earthing station as per IS 3043 complete with GI pipe earthing with salt, charcoal, 2 nos. of 50x6mm GI strip up to test link ,40mm dia GI watering pipe with funnel,test link, earthing chamber of 450x450mm CI cover etc with required civil works complete.The CI Frame and cover shall be of heavy duty type. .
Supply and running of 8 SWG GI wire for Earthing of electrolytic copper / GI earth conductor tapes / wires and laid along with cable or clamped to brick wall, etc., as required.
Supply and running of 25x3mm GI Flat for Earthing of electrolytic copper / GI earth conductor tapes / wires and laid along with cable or clamped to brick wall, etc., as required.
Supply and running of 25x6mm GI Flat for Earthing of electrolytic copper / GI earth conductor tapes / wires and laid along with cable or clamped to brick wall, etc., as required.
Supply and running of 1Cx6sqmm Cu Flexible Cable Earthing (Green) for Earthing of electrolytic copper / GI earth conductor tapes / wires and laid along with cable or clamped to brick wall, etc., as required.
Supply and running of 1Cx4sqmm Cu Flexible Cable Earthing (Green) for Earthing of electrolytic copper / GI earth conductor tapes / wires and laid along with cable or clamped to brick wall, etc., as required.
Busbar of 0.5 Mtr length made out of 25 x 6 mm Cu. strip with drill holes of M8 at 25mm interval mounted on insulators and acrylic cover to be provided.
Busbar of 0.5 Mtr length made out of 25 x 6 mm GI strip with drill holes of M8 at 25mm interval mounted on insulators.
Supply and laying of 2 mm thick rigid FRLS PVC conduits in concealed conduit system using conduit accessories like junction boxes, collars, bends, elbows, binding wires, etc.
32 mm dia conduit
25 mm dia conduit
20 mm dia conduit
LIGHT FIXTURES
Supply Installation Testing and Commissioning of 2x2 Square light fixture- Clean Room Type -1
Supply Installation Testing and Commissioning of 2x2 Square light fixture- Clean Room Type -2
Supply and fixing of danger boards of appropriate voltage grade, size and style as required by Electrical Inspectorate.
Supply of Rubber checkered mat of size 2000 x 1000 x 3mm thick, 11000 V grade.
Supply of Standard First aid box complete with all accessories.
Supply of Wooden framed glass fronted shock treatment chart as per IE rules fixed to wall.
ABC Dry powder type fire extinguisher of 6 Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket etc. complete(ABC type), confirming to IS:2171.
Professional charges towards filing application, preparation of drawings in necessary formats for approval, follow up and arranging approval of drawings, scheme by Local electricity authority Electrical Inspectorate, obtaining clearance from electricity authority / Electrical Inspectorate.
Preparation and Submission of as built drawings of total work executed (2 Sets hard and soft copy)
stage.html
html • 0.04 MB
techsummary_787827.pdf
BOQ Comparative Chart
xlsx
finsummary_787827.pdf
cancelled_1.pdf
pdf • 0.18 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.07 MB
VOLUME1.pdf
Tender Documents • 2.15 MB
BOQ_787827.xls
BOQ • 0.75 MB
PREBIDREPLIES.pdf
PDF • 0.07 MB
LAYOUTS.pdf
PDF • 8.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .