Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC | ₹24.3 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹26.5 L+₹2.2 L (9.04%)Rejected-Finance NO 16 TULASA NIWAS GANESH NAGAR SAMBRA BELAGAVI 591124 | BELAGAVI | BELAGAVI | KARNATAKA | 591124 | ₹26.5 L+₹2.2 L (9.04%) | L2 | Rejected-Finance Second lowest |
| 3 | L3₹31.7 L+₹7.4 L (30.3%)Rejected-Finance | ₹31.7 L+₹7.4 L (30.3%) | L3 | Rejected-Finance Third lowest |
| 4 | L4₹32.8 L+₹8.5 L (34.9%)Rejected-AOC | ₹32.8 L+₹8.5 L (34.9%) | L4 | Rejected-AOC Fourth lowest |
| Sl No | Description | Qty | Unit | PURVIK CONSTRUCTIONS L2 | R. P. Suppliers and Construction Co. L1 | M/S ADITYA CONSTRUCTIONS L3 | shree bhavani constructions L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down switch boards / fitting / fixture , identify and rectify the complaints pertains to internal electrification of any type and nature of MD Accns such as rectification of faulty electric circuit , tightening of loose wiring / conduits replacement of defective accessories such as switch, socket, ceiling rose , holders etc. complete all as specified and directed.
Note:-(i) Defective accessories such as switch, socket, ceiling rose , holders etc. shall be measured and paid separately as 'Supply only".
(ii) Cost of minor stores , such as screws, clamps, washers,bakelite laminated sheet top cover, insulation tapes, nut , bolts etc. shall be deemed including in the quoted rate .
(iii) If the contractor fail to rectify the defects mentioned in the complaint slip on within 48 hrs,. They will be charged Rs. 100/- per complaints/ per day and same will be recovered from their RAR . Each job shall contain 10 complaints.
(iv) The contractor / their rep will collect the complaint from complaint cell ( Concerned JE E/M) every day at 9.00 AM and rectify the complaints 48 hrs and deposit the complaint slip ( duly signed by the users ) to concerned JE E/M. | 200 | Each Job | 60 ₹12,000 | 655.55 ₹1,31,110 | 40 ₹8,000 Lowest | 100 ₹20,000 |
| 2.00 | Taking down carefully (aluminium) point wiring complete of any type (batten/ surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as spcified and directed. | 605 | Point | 2 ₹1,210 Lowest | 3 ₹1,815 | 50 ₹30,250 | 10 ₹6,050 |
| 3.00 | M&L for point wiring for light point or fan point controlled by one switch with and including single core FRLSH PVC insulated and unsheathed stranded copper conductor cable of size 1.5 sqmm 1100 volts grade drawn through and including suitable size of PVC cassing capping with accessories with laminated top cover fixed on MS sunken box for housing of switch, socket, regulator etc complete with and including 1.5 sqmm FRLSH PVC insulated and unsheathed stranded copper conductor cable as earth wire and connected to common earth dolly and making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed . | 100 | Point | 450 ₹45,000 Lowest | 450 ₹45,000 Lowest | 630 ₹63,000 | 500 ₹50,000 |
| 4.00 | All as per Srl item No 3 here-in-before but socket point 5 Amps on independent board -ditto- | 50 | Point | 450 ₹22,500 Lowest | 450 ₹22,500 Lowest | 630 ₹31,500 | 500 ₹25,000 |
| 5.00 | All as per Srl item No 3 here-in-before but socket point 5 Amps on the same board with other switches -dito- | 50 | Point | 150 ₹7,500 | 150 ₹7,500 | 140 ₹7,000 Lowest | 300 ₹15,000 |
| 6.00 | All as per item No 3 here-in-before but cable of 2.5 Sqmm for 15 Amp switch socket outlet on independent board including provision of 2.5 Sqmm PVC insulatred unshethed multistranded copper conductor as earth wire | 50 | Point | 600 ₹30,000 | 500 ₹25,000 Lowest | 750 ₹37,500 | 700 ₹35,000 |
| 7.00 | All as per item No 3 here-in-before but for one light point control by two way switch -ditto-. | 10 | Point | 450 ₹4,500 Lowest | 500 ₹5,000 | 850 ₹8,500 | 500 ₹5,000 |
| 8.00M&L for point wiring with and including single core FRLSH PVC insulated and unsheathed stranded copper conductor cable of size 1.5 sqmm 1100 volts grade drawn through and including suitable size of PVC concealed conduit with accessories with laminated top cover fixed on MS sunken box for housing of switch, socket, regulator etc complete with and including 1.5 sqmm FRLSH PVC insulated and unsheathed stranded copper conductor cable as earth wire and connected to common earth dolly and making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed for the following :- | |||||||
| 8.01 | One Light/fan/exhaust fan/Bell/point controlled by one switch. | 75 | Point | 500 ₹37,500 Lowest | 550 ₹41,250 | 630 ₹47,250 | 600 ₹45,000 |
| 8.02 | One pin 5 amps socket point on the same board with other switches | 50 | Point | 150 ₹7,500 | 100 ₹5,000 Lowest | 180 ₹9,000 | 300 ₹15,000 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
15 Dec 2025, 6:00 pmClosed
GE AF Sambra
GE AF Sambra ATS Sambra Belgaum 591124
REPAIRS TO EXHAUST FANS, WALL FANS, PEDESTAL FANS , CEILING FANS AND REWIRING, FITTINGS, FIXUTRE AT ATS UNDER GE(AF) SAMBRA.
2025_MES_735952_2
GE(AF)/SAM/TOK-46 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Sambra
Please refer Tender documents
9 documents required · 9 mandatory
₹500
GE AF Sambra
₹60,000
Yes
30 Jan 2026
28 Nov 2025
22 Dec 2025
28 Nov 2025
15 Dec 2025
9 Dec 2025
Amount
Taking down switch boards / fitting / fixture , identify and rectify the complaints pertains to internal electrification of any type and nature of MD Accns such as rectification of faulty electric circuit , tightening of loose wiring / conduits replacement of defective accessories such as switch, socket, ceiling rose , holders etc. complete all as specified and directed. Note:-(i) Defective accessories such as switch, socket, ceiling rose , holders etc. shall be measured and paid separately as 'Supply only". (ii) Cost of minor stores , such as screws, clamps, washers,bakelite laminated sheet top cover, insulation tapes, nut , bolts etc. shall be deemed including in the quoted rate . (iii) If the contractor fail to rectify the defects mentioned in the complaint slip on within 48 hrs,. They will be charged Rs. 100/- per complaints/ per day and same will be recovered from their RAR . Each job shall contain 10 complaints. (iv) The contractor / their rep will collect the complaint from complaint cell ( Concerned JE E/M) every day at 9.00 AM and rectify the complaints 48 hrs and deposit the complaint slip ( duly signed by the users ) to concerned JE E/M.
Taking down carefully (aluminium) point wiring complete of any type (batten/ surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as spcified and directed.
M&L for point wiring for light point or fan point controlled by one switch with and including single core FRLSH PVC insulated and unsheathed stranded copper conductor cable of size 1.5 sqmm 1100 volts grade drawn through and including suitable size of PVC cassing capping with accessories with laminated top cover fixed on MS sunken box for housing of switch, socket, regulator etc complete with and including 1.5 sqmm FRLSH PVC insulated and unsheathed stranded copper conductor cable as earth wire and connected to common earth dolly and making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed .
All as per Srl item No 3 here-in-before but socket point 5 Amps on independent board -ditto-
All as per Srl item No 3 here-in-before but socket point 5 Amps on the same board with other switches -dito-
All as per item No 3 here-in-before but cable of 2.5 Sqmm for 15 Amp switch socket outlet on independent board including provision of 2.5 Sqmm PVC insulatred unshethed multistranded copper conductor as earth wire
All as per item No 3 here-in-before but for one light point control by two way switch -ditto-.
M&L for point wiring with and including single core FRLSH PVC insulated and unsheathed stranded copper conductor cable of size 1.5 sqmm 1100 volts grade drawn through and including suitable size of PVC concealed conduit with accessories with laminated top cover fixed on MS sunken box for housing of switch, socket, regulator etc complete with and including 1.5 sqmm FRLSH PVC insulated and unsheathed stranded copper conductor cable as earth wire and connected to common earth dolly and making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed for the following :-
One Light/fan/exhaust fan/Bell/point controlled by one switch.
One pin 5 amps socket point on the same board with other switches
One 3 pin 5 amps socket on independent board.
All as per Srl item No 8 above but with 4.0 sqmm copper wire for 3 pin socket outlet 15 Amp on independent board -ditto-
M&L for point wiring with and including single core FRLSH PVC insulated and unsheathed stranded copper conductor cable of size 1.5 Sqmm 1100 volts grade drawn through in existing conduit with accessories with laminated top cover fixed on MS sunken box for housing of switch, socket, regulator etc complete with and including 1.5 sqmm FRLSH PVC insulated and unsheathed stranded copper conductor cable as earth wire and connected to common earth dolly and making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed for the following :-
One light/fan/exhaust fan/Bell/point controlled by one switch.
One pin 5 amps socket point on the same board with other switches
One 3 pin 5 amps socket on independent board.
All as per Srl item No.10 above but with 4.0 Sqmm copper wire for 3 pin socket outlet 15 Amp on independent board -ditto-
S&F LED T5 Tube light rod ingress protection IP20 18W complete all as specified and directed
S&F T5 tube light 1x18W/20W 4 Ft complete all as specified and directed
S&F LED tube light fitting, 1x 20 to 22 watts, 230 volt, basic all purpose surface and wall mounted led batten with aluminum housing & integrated electronic driver, pre-wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed . Make : Philips Cat Part No.BN021 LED 20S PSU CW GR S2/ Crompton Greaves Cat Part No. LDDR20-CDL Dazzle Ray / Bajaj Cat Part No.BCLAB 20W
S&F LED mirror light fitting , type with high out put diffuser 2 feet, 5watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make:-HAVELLS Cat Part No.-ENDURALINEARNEOBS10WLED865SPCWH/ WIPRO Cat Part No.LL20-111-XXX-65NE3/BCLSB 10 WH
S&F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in replacement lamp holder PVC/Poly carbonate body with back plate complete all as specified and as directed
S&F in replacement Switch piano Single pole 5 Amps, two way, complete all as specified and as directed
S&F in replacement switch piano flush type, Single pole 5 Amps, one way, complete all as specified and as directed
S&F in replacement of switch piano flush type, Single pole 15 Amps, one way, complete all as specified and as directed
S&F in replacement of socket outlet flush type, 3/5 pin, 5/15 Amps, complete all as specified and as directed
S&F in repalcement of Switch Socket combination flush type 15Amps, complete all as specified and as directed
S&F in replacement of socket outlet flush type, 3 pin, 5 Amps, complete all as specified and as directed
S&F in repalcement of Switch Socket combination flush type 5Amps, complete all as specified and as directed
S&F in replacement of ceiling fan regulator electronic type, 230 Volt, 150 Watt with 5 step of control including making holes in laminated bakelite sheet cover and connection complete all as specified and as directed
S&F in replacement of ceiling rose PVC/poly carbonate insulated body three terminal ISI marked complete all as specified and as directed
S&F in replacment PLS Lamp two pin 9/10/11W complete all as specified and directed. Make :Crompton Greaves/Philips/Wipro
S&F in replacment PLS Lamp two pin 18W complete all as specified and directed. Make :Crompton Greaves/Philips/Wipro
S&F in replacement Recessed mounting LED 2'x2' luminaire type complete all as specified and directed. Make:- Baja Cat Part No.BCTBLR 36W ZTN NW or equivelent in CG / Phillips / GE / Wipro / Havells
S&F in replacement MCB single pole, 240 volts of rating 6-32 Amps of C curve breaking capacity of 10 KA complete all as specified and as directed
S&F in replacement MCB suitable for 6 to 32 Amps, 240 Volt AC supply C Curve single pole and neutral(SPN) with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed
S&F MCB 63 Amps, 440 Volt AC supply Triple pole with neutral(TPN) C curve with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed
S&F sheet metal enclosure MCCB DB, double door, vertical TPN 4 way with 200 Amps rated busbar complete all as specified and directed.
S&F MCCB 63 Amps, 4 pole, 415 volts, fixed type breaking capacity 16KA complete all as specified and as directed .
S&F MCCB 100 Amps, C curve TPN, 415 volts,25KA,4 Pole complete all as specified and as directed .
S&F MCCB 125 Amps, C curve TPN, 415 volts, 16KA, 4 Pole complete all as specified and as directed .
S&F blank cover for MCB DBs complete all as specified and as directed .
S&F in replacement Bell Ding dong AC single pole 230volts complete all as specified and as directed .
S&F in replacement Bell push button Piano flush type single pole 5Amps complete all as specified and as directed .
S&F sub main wiring with and including PVC concealed conduit min 25 mm dia with 2 single core 10 sqmm multi-stranded PVC insulated cable unsheathed 1100 volts grade with one earth wire of 10 sqmm copper conductor cable connected to common earth and earth dolly complete and including PVC concealed conduit complete all as specified and as directed . Note:-Two run of 10 sqmm and one run of 10 sqmm shall be measured as one unit
All as per Srl item No 40 above but of size 6 sqmm and earth wire of 6 sqmm
All as per Srl item No 40 above but of size 4 sqmm and earth wire of 4 sqmm
M&L for submain wiring with single core FRLSH PVC insulated, unsheathed stranded copper conductor cable of size using 4runs of 10 Sqmm of voltage rating 1100V for three phase & neutral, drawn in and including concealed PVC conduit of dia not less than 32 mm dia with standard acessories, along with two run of FRLSH PVC insulated, unsheathed, stranded copper conductor of size 2x 6.0 Sqmm as earth continuity conductor all as specified and directed Note:-4 runs of single core FRLSH PVC cable 10sqmm for three phase & neutral with Two run of earth conductor as earth and conduit shall be measured as one unit
M&L for submain wiring with single core FRLSH PVC insulated, unsheathed stranded copper conductor cable of size using 4runs of 6 Sqmm of voltage rating 1100V for three phase & neutral, drawn in and including concealed PVC conduit of dia not less than 32 mm dia with standard acessories, along with two run of FRLS PVC insulated, unsheathed, stranded copper conductor of size 2x 4.0 Sqmm as earth continuity conductor all as specified and directed Note:-4 runs of single core FRLS PVC cable 6sqmm for three phase & neutral with Two run of earth conductor as earth and conduit shall be measured as one unit
S&F in replacement Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 240 volts with 200 Amps rated bus bar,SPN 8 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall, complete all as specified and as directed Note : cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the rate
S&F in replacement Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 240 volts with 200 Amps rated bus bar,SPN 12 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall, complete all as specified and as directed Note : Cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the quoted rate
S&F in replacement Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 240 volts with 200 Amps rated bus bar,SPN 4 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall, complete all as specified and as directed Note : Cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the quoted rate
S&F in replacement Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 240 volts with 200 Amps rated bus bar,TPN 4 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall, complete all as specified and as directed Note : Cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the quoted rate
S&F in replacement single pole and neutral enclosure with two pin and earth plug and socket including 1Nos MCB 20Amps capacity complete all as specified and directed
S & F in replacement LED Bulb 9/12 W (in different colors) complete all as specified and as directed .
S&F in replacement bad side fitting with suitable LED bulb complete all as specified and directed
S&F in replacement Decorative wall light fixture made up of Polycarbonate, suitable for retrofit 9/11 W LED lamp complete all as specified and directed
Dismantling and taking out faulty wiring including casing and capings/conduits etc and refixing the same after rectification of fault in original position including replacment of copper/aluminum cable any size not more than 10 mtr and casing/capping/conduit not more than 5 mtr and testing after completion complete all as specified and directed
S&F switch Modular type, 6 Amp, 1 module single pole one way, 230 Volts, Modular type complete all as specified and directed
S&F switch Modular type, 16 Amp, 1 module single pole one way, 230 Volts, Modular type complete all as specified and directed
S&F Switch Socket combination 3 Pin 6 Amps modular type, 2/3 pin combined 3/4 module 230 Volts complete all as specified and directed
S&F Switch Socket combination 3 Pin 6/16 Amps modular type, 2/3 pin combined 4 module 230 Volts complete all as specified and directed
S&F fan step regulator modular type,120W -1/2 module (As par existing size ) electronic socket type five step controlled 230V AC 50 Hz complete all as specified and directed
S&F in repairs modular white cover plate with frame but 1 module complete all as specified and as directed.
S&F in repairs modular white cover plate with frame but 2 module complete all as specified and as directed.
S&F in repairs modular white cover plate with frame but 3 module complete all as specified and as directed.
S&F in repairs modular white cover plate with frame but 4 module complete all as specified and as directed.
S&F in repairs modular white cover plate with frame but 6 module complete all as specified and as directed.
S&F in repairs modular white cover plate with frame but 8 module complete all as specified and as directed.
S&F in repairs modular metel flush box but 1,2,3 module complete all as specified and as directed
S&F in repairs modular metel flush box but 4 module complete all as specified and as directed
S&F in repairs modular metel flush box but 5/6 module complete all as specified and as directed
S&F in repairs modular metel flush box but 7/,8 module complete all as specified and as directed
S&F in repairs GI flush sunken box but any size to suit complete all as specified and as directed
S&F in repairs 3mm thick bakelite laminated sheet top cover with copper screw any size to suit complete all as specified and as directed
S&F single core 1.5 sqmm size cable (nominal area) PVC FRLSH multistanded copper conductor cable 1100 volts ISI marked draw throw existing point wiring complete all as specified and as direected.
S&F single core 2.5 sqmm size cable (nominal area) PVC FRLSH multistanded copper conductor cable 1100 volts ISI marked draw throw existing point wiring complete all as specified and as direected.
S&F single core 4 sqmm size cable (nominal area) PVC FRLSH multistanded copper conductor cable 1100 volts ISI marked draw throw existing point wiring complete all as specified and as direected.
S&F single core 6 sqmm size cable (nominal area) PVC FRLSH multistanded copper conductor cable 1100 volts ISI marked draw throw existing point wiring complete all as specified and as direected.
Taking down submain wiring Aluminium/ copper of any size including earth continuity condutor on teak wood or conduit and removing from site and making good the disturbed surface of wall etc complete all as specified and directed.
S&F in repairs plug top, 3 pin 15 Amps, including making necessary connections complete all as specified and directed
S&F in repairs high brightness IP65 strip with uniformity of light required for outdoor application on wall and on pole complete all as specified and directed
Taking down ceiling fan for repairs/servicing (i.e.greasing/oiling etc.), 1200/1400 mm sweep of any make and any type model, sealing cable end with tape, dismantling the blades, removing ceiling fan with all accessories and deposit to AGE E/M store Yard complete all as specified and as directed. Note:-(i) The ceiling fans details i.e fan MES Nos with proper inventory must be submitted to Engineer-in-Charge (ii) (ii) Defective parts shall be measured and paid separately as "Supply only"
Hanging only ceiling fan and connection up the point including provision of cable from ceiling rose to fan complete all as specified and as directed. Note:-Cable using ceiling rose to fan for connection shall be measured and paid as 'Supply only" in the respective item of BOQ
M&L for re-winding of ceiling fan of size 1200 mm sweep with super enameled copper winding wire of gauge as per existing size /No. of turns confirming to IS, including varnishing the motor windings with best quality varnish complete all as specified and as directed.
M&L for re-winding of ceiling fan of size 1400 mm sweep with super enameled copper winding wire of gauge as per existing size /No. of turns confirming to IS, including varnishing the motor windings with best quality varnish complete all as specified and as directed.
Supply only ball bearing of size/No. 6201 confirming to IS complete all as specified and as directed.(Make: NBC/SKF)
Supply only ball bearing of size/No. 6202 confirming to IS complete all as specified and as directed.(Make: NBC/SKF)
Supply only ball bearing of size/No. 6203 confirming to IS complete all as specified and as directed.(Make: NBC/SKF)
Supply only brass bush suitable for ceiling fan of any make and model confirming to IS complete all as specified and as directed.
Supply only shaft for ceiling fan as per existing size and shape complete all as specified and as directed.
S&F fabricated down rod made out of 15mm dia MS Pipe medium duty 60 cm long duly painted including nut, bolt & washer etc and including drilling holles on top and bottom fan fixing with fan hooks and ceiling fan respectively as reuired suitable for 1200/1400mm sweep of ceiling fan complete all as specified and directed .
S&F fabricated down rod made out of 15mm dia MS Pipe medium duty 30 cm long duly painted including nut, bolt & washer etc and including drilling holles on top and bottom fan fixing with fan hooks and ceiling fan respectively as reuired suitable for 1200/1400mm sweep of ceiling fan complete all as specified and directed .
Supply only 'D' Clamp with nuts, bolts, quarter pin and rubber reel suitable for 1200/1400 mm sweep of ceiling fan all as required at site complete all as specified and as directed.
Supply only condenser 2.5 MFD confirming to IS complete all as specified and as directed.
Supply only flexible wire of size 23/0.0076 stranded copper conductor complete all as specified and as directed.
Supply only bottom cover (bowl) of suitable for ceiling fan of any make and model as per existing size and shape complete all as specified and as directed.
Supply only PVC Canopies (Set of two) as required at site and complete all as specified and as directed
Supply only fan blade (set of three) set suitable for 1200mm sweep ceiling fan of any make complete all as specified and as directed.
Supply only fan blade (set of three) set suitable for 1400mm sweep ceiling fan of any make complete all as specified and as directed.
M&L for cleaning and preparation of old surface of the ceiling fan complete of size 1200/1400mm sweep and spray coat painting with synthetic enamelled paint including writing fan Nos with letters of size 2.5cm with black paint complete all as specified and as directed
Taking down and dismantling of exhaust fan 225mm/300mm /375mm/450mm sweep of any make and model with all accessories and deposit to AGE E/M store Yard, opening the cover, separating the rotor and stator assembly, locating the fault and making the fan fully serviceable condition including replacing the defected worn out screw, flexible wire of size 23/0.0076 , oiling/greasing the fan and re-assembling the same and testing complete all as specified and as directed. Note:-(i) The exhaust fan details i.e exhaust fan MES Nos with proper inventory must be submitted to Engineer-in-Charge (ii) Defective parts shall be measured and paid separately as "Supply only"
Fixing only exhaust fan and connection up the point including provision of cable from ceiling rose to fan complete all as specified and as directed. Note:-Cable using ceiling rose to fan for connection shall be measured and paid as 'Supply only" in the respective item of BOQ
M&L for re-winding of exhaust fan 225mm sweep with super enameled copper winding wire as per existing size confirming to IS including varnishing the motor windings with best quality varnish complete all as specified and as directed.
All as per Srl item No. 99 here in above but of size 300mm sweep complete all as specified and as directed.
All as per Srl item No. 99 here in above but of size 375mm sweep complete all as specified and as directed.
All as per Srl item No. 99 here in above but of size 450mm sweep complete all as specified and as directed.
Supply only blades for exhaust fan of 225mm sweep complete all as specified and as directed.
Supply only blades for exhaust fan of 300mm sweep complete all as specified and as directed.
Supply only blades for exhaust fan of 375mm sweep complete all as specified and as directed.
Supply only blades for exhaust fan of 450mm sweep complete all as specified and as directed.
Supply only condenser 04 MFD confirming to IS complete all as specified and as directed.
Supply only MS shaft for exhaust fan as per existing size and shape complete all as specified and as directed.
Supply only MS back side cover for exhaust fan of any sweep, size and make complete all as specified and as directed.
Supply only exhaust fan louver shutters of size ( 225/300/ 375/450mm) and make complete all as specified and as directed
M&L for cleaning and preparation of old surface of the exhuast fan complete of size ( 225/300/375/450mm) and Spray painting with synthetic enamelled paint including writing exhaust fan Nos with letters of size 2.5cm with black paint complete all as specified and as directed
S&F PVC fresh air circulated fan with louver shutters (exhaust fan) of size 225/300mm complete all as specified and directed
Taking down and dismantling of Pedstal Fan of any size & any make and model, opening the cover, separating the rotor and stator assembly, locating the burnt / fault and making the fan fully serviceable condition including rewinding of motor as per exisitng gauge, replacing condencer 4 MFD, old borken blade, defected worn out screw, flexible wire of size 23/0.0076 , oiling/greasing the fan and re-assembling the same and testing complete all as specified and directed
Taking down and dismantling of Wall mounted fan of any size & any make and model, opening the cover, separating the rotor and stator assembly, locating the burnt / fault and making the fan fully serviceable condition including rewinding of motor as per exisitng gauge, replacing condencer 4 MFD , old borken blade, defected worn out screw, flexible wire of size 23/0.0076 , oiling/greasing the fan and re-assembling the same and testing complete all as specified and directed
Taking down and dismantling of Air Circulated Fan of any size & any make and model, opening the cover, separating the rotor and stator assembly, locating the burnt / fault and making the fan fully serviceable condition including rewinding of motor as per exisitng gauge, replacing condencer 4 MFD , old borken blade, defected worn out screw, flexible wire of size 23/0.0076 , oiling/greasing the fan and re-assembling the same and testing complete all as specified and directed
Taking down and dismantling of BLDC ceiling fan of any size & any make and model, opening the cover, separating the rotor and stator assembly, locating the burnt / fault and making the fan fully serviceable condition including rewinding of motor as per exisitng gauge, replacing difective PCB , defected worn out screw, flexible wire of size 23/0.0076 , oiling/greasing the fan and re-assembling the same, testing and refixing complete all as specified and directed
PURVIK CONSTRUCTIONS (BID ID -3497989)
M/S ADITYA CONSTRUCTIONS (BID ID -3505229)
shree bhavani constructions (BID ID -3498262)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_830908.xls
BOQ • 3.51 MB
tender.pdf
Tender Documents • 1.02 MB
psii.pdf
Additional Documents • 1.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .