Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance NEAR GOVT HIGHER SECONDARY SCHOOL NO 1 MALL ROAD MORAR GWALIOR 474006 M P | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | Admitted-Finance |
| 3 | Admitted-Finance ANAND BHAVAN GHASMANDI MORAR GWALIOR MP 474006 | GWALIOR | GWALIOR | MP | 474006 | Admitted-Finance |
| 4 | Admitted-Finance SAI LEELA MAHAVIR COLONY BIRLA HOUSE GOLA KA MANDIR MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MADHYA PRADESH | 474005 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
16 Dec 2024, 6:00 pmClosed
GE (AF) TECH AREA GWALIOR
GE (AF) TECH AREA GWALIOR
REPAIR/MAINT OF RCC CHAJJA, FACIA, ROOF TREATMENT, PERIODICAL AND MISC REPAIR WORKS AT AF STN GWALIOR
2024_MES_685160_1
8900/1528/GWL/E8
Open Tender
Civil Works
Item Rate
330 days
GWALIOR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) TECH AREA GWALIOR
₹90,000
Yes
23 Dec 2024
22 Nov 2024
19 Dec 2024
22 Nov 2024
16 Dec 2024
2 Dec 2024
Amount
Demolition of brick work or stone masonry of any description and in any position built in cement mortar including all quoins, arches pillar etc including disposal of rubbish complete all as specified and directed.
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6 M mean radius built in CM (1:6) complete all as specified and directed.
All as per item No 2 here-in-before but, except brick using old retrieved bricks obtained from demolition in serviceable conditions complete all as specified and directed.
M&L for 15mm thick rendering fair face of brickwork or concrete surfaces in CM 1:4 finished even and smooth (without using exrtra cement)etc complete all as specified and directed.
M&L for 15mm thick rendering other than fair face of brickwork or concrete surfaces in CM 1:6 finished even and smooth (without using extra cement)etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M & L for PCC (1:2:4) type B0, using 12.5mm graded stone aggregate as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs including necessary form work complete all as specified and directed by Engr-in-Charge
Demollition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for RCC (1:2:4) type B-1 (using 20mm graded aggregate) as in shelves, chajja , etc including necessary form work complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately)
M&L for RCC (1:2:4) type B-1 (using 20mm graded aggregate) as in Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like for etc including necessary form work complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately)
M&L for RCC (1:2:4) type B-1 (using 20mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary form work complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately)
M&L for RCC (1:2:4) type B-1 (using 20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span including necessary form work complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately)
M&L for RCC (1:2:4) type B-1 (using 20mm graded aggregate) as in Columns, pillars, piers, posts including necessary form work complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately)
S&F mild steel TMT bars of 10 mm dia and over cut to length, bent to shape as required including cranking, bending, spirally for hooping for column hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia for securing with clips complete all as specified and directed.
All as per item No 14 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
M & L for repairing of damaged RCC Chajja, fascia, fins, roof projection, ceiling and balcony railing etc at any height upto 10.00 M by rendering 10 to 30mm thick in one or two layers as per site requirement in CM 1:3 incl hacking out old broken/damaged concrete portion, cleaning of old reinforcement etc and applying neat cement slurry @ 3 Kg/Sqm complete all as specified and directed. (Note : rate for all scaffolding required for repairing work shall be deemed included in this rate)
M&L for Providing, cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregates) in roof kerbs or mud stops, rounded or chamfered on edges and padding over roof surfaces etc complete all as specified and as directed.
M&L for Cement concrete tiles 20cm x 20cmx 20mm thick, machine pressed; set jointed and pointed in neat cement slurry in roofs, and pointed in neat cement slurry with grey cement and no pigment over 15mm thick screed bed in CM 1:4 including dismantling of existing tiles with screed without disturbing the roof treatment/ bituminous felt complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
M & L for 10 mm thick screed bed in cement mortar 1:4 mixed with using liquid water proofing compound as per manufacturers instructions (Note:Water proofing compound shall be measured and paid separately under respective item of "BoQ") over roof top surface finished even and smooth using extra cement and application of water proofing treatment using APP modified roof membrane over existing RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying bitumen primer @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Applying hot blown grade bitumen 85/25 @ 1.2 Kg/Sq M over primer. (d) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap by authorized applicators.
M&L for 10mm thick screed bed in cement mortar 1:4 mixed with using liquid water proofing compound as per manufacturer instructions (Note : Water proofing compound shall be measured and paid separately under respective item of BOQ) and Supply and application of 5 layer SHR waterproofing Coating System as per manufacturer application procedure on leaking concrete surface by through surface preparation with high pressure water jet min 125 bars, opening the cracks, followed by one absorption coat of Nano-tech enhanced elastomeric water proofing (NEEWP) emulsion havig UV resistance and min 50% solids, filling and sealing the cracks, then over coating with 2 coats of NEEWP + cement mixtures as water proofing coat having + 450% elongation. The surface is then to be tested for water tightness with ponding test for min 2 days and then top coated with 2 coats of SHR coating oure acrylic based, UV resistant, non yellowing, bio-organism resistant (anti fungal, anti bacterial) conforming to BIS STD IS-17218:2019 with pull off adhesion 2.8 Mpa, passes 2000 hrs accelerated durability test, suitable for all types of cementitious surfaces, white colour, mat, surface coverage 3.25 Sqm/Ltr/2 coats, DFT 100-120 microns using brush, roller, airless spray guns as applicable. The product should be tested at NABL approved Lab andf application is to be done by company approved applicator only
M&L for preparation of treated surface of roof and applying one coats of aluminium paint completed all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed..
M&L for glazed ceramic Coloured tiles in vertical surface 350x 250x 7mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering on fair faces of brick work or concrete surface in cement mortar 1:4 complete all as specified and directed.
Demolition of cement concrete ( unreinforced) including floor tile ground floors and pavings n. exc 15 cm thick below or above G.L complete all as specified and directed.
M&L for 25 mm thick PCC (1:2:4) type B0 (12.5 mm graded stone agg) as in sub base of flooring complete all as specified and directed.
M&L for non skid joint free coloured ceramic tiles 7-8mm thick (Square/ Rectangular), area of each tiles exc 0.11 Sqm but not exc 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles over 15 mm thick screed bed or bedding in layer of mortar for laying floor finishes in cement mortar 1:6 complete all as specified and directed.
M&L Double charged Vitrified Ceramic tiles 8-10 mm thick (square/rectangular) polished, area of each tiles n exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match light shade incl 15mm thick screed bed in CM 1:6. complete all as specified and directed.
M&L Double charged Vitrified Ceramic tiles 8-10 mm thick (square/rectangular) polished, area of each tiles n exceeding 0.36 sqm, in skirting/dado or vertical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match light shade incl 10mm thick Rendering in CM 1:4. complete all as specified and directed.
S&F in repairs 150mm dia PVC (SWR) pipes single socketed in any length at any height with rubber ring joints fixed to walls/ hanger cladding with necessary brackets including tee and bends complete all as specified and directed.
M&L for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including Dismantling of existing Plain or corrugated steel /AC Sheet complete all as specified and directed.
M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, Ridge, valley/ gutter fixed with self tapping screws including Dismantling of existing Plain or corrugated steel /AC Sheet complete all as specified and directed.
M&L for 5-30mm thick rendering on concrete surfaces as in ceiling in CM 1:3 finished even and smooth without using extra cement incl Hard drawn steel wire fabric wt n exc 4kg per sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcement after cleaning reinforcement by anti corrosive chemical incl taking down cement plaster on concrete surface incl preparation of newly plastered surface and applying three coats of white wash complete all as specified and directed.
M&L for 15mm thick rendering fare face of brick/stone masonry walls in CM 1:4 finished even and smooth (without using extra cement) including taking down cement plaster on brick surface or stone including raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
S&F in repairs 5mm thick tinted glass fixed with necessary rubber gasket and aluminium snap beadings tint match with existing complete all as specified and directed.
Supply and fix in repairs 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n.exe 0.50 Sqm in each pane complete all as specified and directed.
M&L for Preparation of old decorated surfaces of wall including cornices, by brooming down or steel wire brushing to remove dust, dirt and loose scales of lime wash and other foreign material, scrapping down, smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including filling the cracks and depressions with putty and applying one coat of white wash(tint as approved by GE) by the use of rollers complete all as specified and directed.
Ditto as per item No 37 here-in-before but one coat of white wash on ceiling surface complete all as specified and directed.
Ditto as per item No 37 here-in-before but one coat of distemper oil emulsion on ceiling surface complete all as specified and directed.
M&L for Preparing old decorated plastered or unplastered surfaces of external walls and applying one coat exterior weather proof Paint by the use of rollers including filling cracks/depressions with putty to make the adjacent surface even and smooth complete all as specified and directed.
M&L for Preparing old painted surfaces of wood and wood based materials of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for Preparing old painted steel & iron surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for Preparing old painted steel & iron surfaces of any description n.exc 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers and applying a coat with putty to make the surface even and smooth matching to the adjacent wall surfaces and applying two coat of distemper oil emulsion over a coat of primer by the use of rollers by the use of rollers, over a coat of primer all as specified and directed.
M&L for preparation of surfaces of wood and wood based materials of any description, width or girth including cleaning and a coat of wood filler on old works and applying french polish in one or more coats to the required texture and glossy finish complete all as specified and directed.
M&L for Preparing old decorated plastered or unplastered surfaces of walls including filling the cracks, depressions with putty to match with the adjacent surface and applying one coat of plastic emulsion paint, white or tinted by the use of rollers as approved complete all as specified and directed.
M&L for preparation of old decorated Brick tile /Concrete tiles (Chequered / interlocking tiles) cleaning by any means, and applying one coat of floor tile paint any colour with spray gun/compressor complete all as specified and directed as approved by Engr-in-Charge. Make: INDOGO Floor Paints or Apex Floor Guard of Asian Paints
M&L for complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, and applying two coat of Texture paint over a coat of primer of any colour complete all as specified and directed.
M&L for preparation of old painted surface and applying one coats of aluminium paint on steel surface of any description over 10cm in width or girth completed all as specified and directed.
M&L for preparation of existing corrugated galvalume/CGI roof sheets surfaces/steel surfaces incl rubbing cleaning dust, rust etc with sand paper and steel scrappers or any other means, and applying two coats of synthetic enamel paint in camouflaging pattern on CCD scheme over a coat of red oxide primer on Aircraft sun shelter/Hangar roof sheets etc, at 12 to 15 mtr height, with necessary scaffolding complete all as specified and directed.
M&L for Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, and filling the cracks and depressions with putty/ chalk whitening to make the surface even and smooth matching to the adjacent wall surfaces applying two coat of external emulsion paint/weather coat, in camouflaging pattern on CCD scheme (Pattern as approved by GE) by the use of rollers on surfaces of any type of building, wall, any surfaces, any height, Over a coat of primer complete all as specified and directed. Note- Rate quoted by contractor incl scaffolding and T&P upto 15m height of the building. No extra payment admissible on this account.
M&L for applying one coat of external emulsion paint/weather coat, in camouflaging pattern on CCD scheme (Pattern as approved by GE) by the use of rollers on surfaces of any type of building, wall, any surfaces, any height, incl preparation of old decorated surfaces complete all as specified and directed. Note- Rate quoted by contractor incl scaffolding and T&P upto 15m height of the building. No extra payment admissible on this account complete all as specified and directed.
M&L for Preparation of newly Plastered surfaces and applying two coats of white wash complete all as specified and directed.
M&L for Preparation of newly plastered surface and applying two coat of weather coat exterior emulsion (Make : ACE of Asian Paints or equivalent in Berger Paints etc) white or tinted by the use of rollers over a coat of primer as approved complete all as specified and directed.
M&L for Preparation of newly plastered surface and applying two coat of distemper oil emulsion white or tinted by the use of rollers over a coat of chalk whitening primer (preparatory to distempering) as approved complete all as specified and directed.
M&L for Preparation of old surface of wall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots including filling the cracks and depressions and applying one coat of distemper oil emulsion with roller white or tinted on any type of bldg. at any height as approved complete all as specified and directed.
M&L for Writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high complete all as directed by EIC. (Note :Letters etc., shall be painted with thick paint, so that they stand out boldly and solidly without showing signs of brush marks)
S&F MS tubular pipes as in vertical post , rafter & purlins as in sheds/canopy cut to reqd shape , welding drilling and including bending as necessary , gusset plates, riveting , etc confirming to Fe-290 Gde-E-165 complete all as specified and as directed. Make: ISI Marked as approved by GE
M&L preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer over 10m width or girth complete all as specified and directed
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, and getting out in Hard/dence soil and removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point and all as specified and directed
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregtaes) as in sub base to foundation filling and mass concrete all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed
Taking down carefully aluminum /copper point wiring (light, fan, switch & power) complete including fittings such as switches, ceiling rose, pendent, by unscrewing from board ,out let box, fitting and fixture such as bulk head fitting, sketch fittings and making good the disturbed surfaces of walls floors etc all as directed.
M&L for point wiring with stranded copper conductor 1.5. Sqmm 1100 Volts grade FRLS PVC insulated and unsheathed including ISI marked PVC casing capping of required sizes as indicated including all accessories, copper conductor cable 1.5 Sqmm insulated and unsheathed PVC cables as earth wire, terminal boxes closed recossed type. PVC Plastic board all as required as specified and directed for the following :- (a) One light/ Fan point controlled by one way switch.
(b ) One 5 Amps switch socket combination on independent board. complete all as specified and directed.
(c) One 5 Amps socket on same board with other switches. complete all as specified and directed.
All as per item No-64 here in above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socket point as directed.
S&F switch piano flush type single pole one way 5 Amps 230 V complete all as specified and directed.
S&F switch socket out let 3 pin 5 Amps flush type 230 Volts multipurpose, complete all as specified and directed.
S&F switch socket out let 5 Amps and 15 Amps multipurpose( 3 Pin 15 Amps and one pin 5 Amps controlled by one switch.).complete all as specified and directed.
S&F fan regulator Electronic Step type (min 5 steps) 2module, 100W ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc. complete all as specified and directed by Engineer-in-Charge.
S&F lamp holder insulated body with back plate for battern fittings complete all as specified and directed by Engr-in-charge.
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm FRLS of voltage rating 1100 Volts drawn in and including surface in PVC casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating 1100 Volts drawn in and including surface in PVC casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm, FRLS of voltage rating upto and including 1100 Volts drawn in existing conduit along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. Note:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit.
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in existing conduit along-with one run of PVC (Green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. Note:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit
Supply, fixing, connecting & testing of sheet metal enclosures single pole and neutral with a two pin earth plug and socket complete with one single pole 20 amp MCB complete all as specified and directed.
Supply, fixing, connecting & testing in repair of sheet metal enclosures (IP-54 Protection) triple pole and earth with three pin earth plug and socket complete with one TPN 32 Amp MCB complete all as specified and directed.
Supply, fixing, connecting & testing in repair of sheet metal enclosures double door (IP-42 Protection), triple pole and neutral, 4 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating complete all as specified and directed.
All as per item No.77.00 here-in-before but distribution board single pole and neutral, 12 way complete all as specified and directed.
All as per item No.77.00 here-in-before but distribution board single pole and neutral, 8 way complete all as specified and directed.
All as per item No.77.00 here-in-before but distribution board single pole and neutral, 4 way complete all as specified and directed.
Supply and fixing in replacement of LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge.
All as per item No. 81.00 but LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge.
All as per item No. 81.00 but LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and complete all as specified and directed by Engr-in-charge.
Supply& Fixing in replacement of LED Batten fittings 1x20 Watt complete with round block etc, incl PVC gutties and flexible wire and connecting to ceiling rose complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in replacement of decorative surface mounting 36 watt LED full out put luminaries which provides soft light glare free symmetrical illumination suitable for Armstrong/Grid ceiling, white powder coated sheet steel housing with paralite P5 square parabolic louver block in metallic perforated frame for low glare, aluminium reflector and accessories ,connecting the same to electric source with and including copper conductor 23/0.0076 flexible twisted twin core cable, including all accessories and fixing arrangements for fixing the 2x2 LED light fitting to false ceiling complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of 10 Watt LED bollard light one meter long with Opel acrylic diffuser and IP-65 protection including necessary PCC base work complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp Complete all as specified and directed by Engr-in-charge.
S & F in replacement of LED light fitting 1x9W/1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of LED building security/street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge.
M/s Gulshan and Brothers (BID ID -3187644)
M/s. Ravi and brothers (BID ID -3184180)
M/S Pramod Kumar Jain (BID ID -3184437)
SHRI HARI CONSTRUCTION (BID ID -3184575)
M/s Anjali Construction (BID ID -3184707)
Ganga and Sons (BID ID -3181338)
m/s vikash Engineers (BID ID -3184488)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .