| 1 | L1₹9.8 LAdmitted-Fee/PreQual/Technical/Finance ADD 5 SARDAR PATEL MARG CIVIL LINES PRAYAGRAJ | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | L1 | Admitted-Fee/PreQual/Technical/Finance | ||
| 2 | L2₹10.1 L+₹29,257.66 (2.99%)Admitted-Fee/PreQual/Technical/Finance | L2 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
15 Sept 2026, 3:00 pmClosed
Executive Engineer
C.D. Prayagraj-02, UPAVP., Pratapgarh
REMOVAL OF DEFECTS AND REMAINING WORK IN NON RESIDENTIAL BUILDING AT 100 BEDDED COMBINED HOSPITAL SHIVSAT, DISTT-PRATAPGARH.
2026_UPHDB_1183487_1
1703/L-11/180 Dated 03.09.2026
Open Tender
Civil Works
Percentage
30 days
Shivsat
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
Executive Engineer, C.D. Prayagraj-02, UPAVP.
₹20,000
Yes
16 Sept 2026
8 Sept 2026
15 Sept 2026
8 Sept 2026
15 Sept 2026
8 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | 500 | SQM | 80.83 | ₹40,415 |
| 2 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20
kg/ 10 sqm) | 2,769 | SQM | 63.77 | ₹1,76,579.13 |
| 3 | Class 150 brick work in in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. | 12.5 | CUM | 5,425.22 | ₹67,815.25 |
| 4 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. | 4 | CUM | 6,565.57 | ₹26,262.28 |
| 5 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. | 4.71 | QTL | 6,409 | ₹30,186.39 |
| 6 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. | 150 | SQM | 110.46 | ₹16,569 |
| 7 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal sizelaid in onelayer neat cement (25 mm thick floor). | 350 | SQM | 225.65 | ₹78,977.5 |
| 8 | Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to rooffroof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates an universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer's pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement.in The Joint System shall resists damage or deterioration from the impact of exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall conform to ASTM 6063). Roof Joint of 100 mm gap | 8 | meter | 4,312.42 | ₹34,499.36 |
| 9 | Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221-02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063) Wall Joint of 100 mm gap . | 30 | meter | 3,868.05 | ₹1,16,041.5 |
| 10 | Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with an universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer's pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in all the as Joint System to have watertight joint is mandatory requirement per the manufactures design and as approved by Engineer -in- Charge. ( Material shall conform to ASTM 6063) Floor Joint of 100 mm gap . | 16 | meter | 4,645.72 | ₹74,331.52 |
stage.html
html • 0.02 MB
finance_2225840.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.10 MB
BID.pdf
Tender Documents • 24.41 MB
BOQ_2225840.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .