| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC 0 BETTER POWER SERVICES PVT LTD A K AZAD ROAD REHABARI KAMRUP ASSAM 781008 | KAMRUP METRO | ASSAM | 781008 | L1 | Accepted-AOC Quoted rate found Lowest (L1). | |
| 2 | L2₹9.6 L+₹88,640 (10.2%)Rejected-Finance 321 PATIL NAGAR BAWDHAN ROAD BAVDHAN BUDRUK PUNE MAHARASHTRA 411021 | PUNE | MAHARASHTRA | 411021 | L2 | Rejected-Finance Quoted rate found 2nd Lowest (L2). | |
| 3 | L3₹12.7 L+₹4.0 L (45.7%)Rejected-Finance 685 SONARPUR STATION ROAD GREEN PARK KOLKATA 700103 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700103 | L3 | Rejected-Finance Quoted rate found 3rd Lowest (L3). | |
| 4 | L4₹12.9 L+₹4.2 L (47.9%)Rejected-Finance 2 BOSE PARA ROAD BARISHA KOLKATA WEST BENGAL 700008 | KOLKATA | WEST BENGAL | 700008 | L4 | Rejected-Finance Quoted rate found 4th Lowest (L4). | |
| 5 | L5₹13.3 L+₹4.6 L (52.6%)Rejected-Finance VILL DAKSHIN SHIBGANJ P O AND P S PATHARPRATIMA DIST SOUTH 24 PARGANAS | SOUTH 24 PARGANAS | WEST BENGAL | L5 | Rejected-Finance Quoted rate found 5th Lowest (L5). |
| Sl No | Description | Qty | Unit | Prostarm Info Systems limited L2 | Better Power Services Pvt.Ltd. L1 | Rajalakshmi Enterprise L4 | WISE CHOICE L3 | B. ENGINEERING CO. L5 | ASIM KRISHNA MODAK L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00SITC of 30 KVA UPS including Battery Bank of (21371 ~ 24960) VAH or higher (SMF Battery 12 Volt, 45AH ~125AH) 3ph Input /3ph Output, Static by-pass arrangement, compitable with D.G.Set, DSP controlled IGBT based rectifier with minimum 90% efficiency on 100% Load. The UPS shall be provided with active input P.F. Correction system to obtain 0.9 lag at 100% resistive Load, Wave form - Pure sine wave. Crest Factor- 3:1 It Should be capable of operating in 50'c above ambient temprature, Built in Solid State float cum boost charger with automatic boost / trickel charge mode with current Limiting features. The charger should be designed for at least 15% of the total battery current. The UPS Should have current limiting protection, built in over load / Short circuit protection with snubber circuits for current limit. Soft start arrangement, Over voltage / under voltage protection, mains ON, Inverter ON/ OFF/ FAULTY/ TRIP (Reason), Charger ON/ FAULTY or TRIP, Battery Low, Static by-pass ON, Over temperature. Inbuilt Isolation Transformer of 1:1 ratio connected in Delta- Star Mode. Battery set Complete with self-standing cubicle or cabinet. The UPS should have external automatic load transfer switch for parallel operation. | |||||||||
| 1.01 | Regulated Sealed Lead Acid Battery, Construction type : AGM or VRSLAB in ABS Flame Retardant Rating (12V SMF Battery - 45AH ~125AH) (Battery Make Amararaja /Quntra/Exide Power Safe. Back-up time: 30 Min at full load. Warranty : One Year on UPS and One Year on SMF Battery on-site against any manufacturing defects. Certificate : ISO 9001:2015, ISO 14001:2015, ISO 18001,OHSAS 18001. CE Certification: IEC/ EN 62040-1-1, IEC/EN50091- 1,IEC/EN 60950(Safety),IEC/ EN 5009 I-2,IEC/ EN 62040-2 (EMC Emmission), IEC/EN 62040-3 (Performance & Design), IEC/EN 61000-4(EMC Emmunity) & IEC/ EN 60146 (Design & Manufacture)
Make: APC-Schneider Electric / NUMERIC/ Power One/ VERTIV/ Switching AVO/ Powersafe/ Delta/Better Power/ Prostarm. | 2 | Nos | 4,79,320 ₹9,58,640 | 4,35,000 ₹8,70,000 Lowest | 6,43,300 ₹12,86,600 | 6,33,696 ₹12,67,392 | 6,63,730 ₹13,27,460 | 7,19,500 ₹14,39,000 |
| 2.00TERMS & CONDITIONS | |||||||||
| 3.00(i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST. (ii) All materials, equipments & accessories must conform to relevant IS / IEC specifications. (iii) Necessary manufacturer's warranty certificate will have to be submitted during delivery of the material. iv) 2 years Full Comprehensive warranty on both UPS and Battery from the date of Installation. v) OEM/Bidder must have local service center / service engineer within Malda pin code area (For any verification: Authentic documents to be attached with last 3 months salary slip & PF no). | |||||||||
Tender Value
Refer Docs
EMD Value
₹29,400
Closing Date
26 Aug 2025, 3:00 pmClosed
EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION
O/O THE EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION Singatala Malda PIN 732101
Construction of G plus 3 Storied Building for 50 beded Critical Care Block at Malda Medical College and Hospital, Malda - SITC of UPS
2025_WBPWD_888551_1
WBPWD/EE/MED/e-NIQ-21/2025-26
Open Tender
Electrical Work/ Equipment
Item Rate
15 days
Malda
Please refer Tender documents.
6 documents required · 6 mandatory
₹29,400
Yes
13 Mar 2026
7 Aug 2025
28 Aug 2025
7 Aug 2025
26 Aug 2025
13 Aug 2025
Amount
SITC of 30 KVA UPS including Battery Bank of (21371 ~ 24960) VAH or higher (SMF Battery 12 Volt, 45AH ~125AH) 3ph Input /3ph Output, Static by-pass arrangement, compitable with D.G.Set, DSP controlled IGBT based rectifier with minimum 90% efficiency on 100% Load. The UPS shall be provided with active input P.F. Correction system to obtain 0.9 lag at 100% resistive Load, Wave form - Pure sine wave. Crest Factor- 3:1 It Should be capable of operating in 50'c above ambient temprature, Built in Solid State float cum boost charger with automatic boost / trickel charge mode with current Limiting features. The charger should be designed for at least 15% of the total battery current. The UPS Should have current limiting protection, built in over load / Short circuit protection with snubber circuits for current limit. Soft start arrangement, Over voltage / under voltage protection, mains ON, Inverter ON/ OFF/ FAULTY/ TRIP (Reason), Charger ON/ FAULTY or TRIP, Battery Low, Static by-pass ON, Over temperature. Inbuilt Isolation Transformer of 1:1 ratio connected in Delta- Star Mode. Battery set Complete with self-standing cubicle or cabinet. The UPS should have external automatic load transfer switch for parallel operation.
Regulated Sealed Lead Acid Battery, Construction type : AGM or VRSLAB in ABS Flame Retardant Rating (12V SMF Battery - 45AH ~125AH) (Battery Make Amararaja /Quntra/Exide Power Safe. Back-up time: 30 Min at full load. Warranty : One Year on UPS and One Year on SMF Battery on-site against any manufacturing defects. Certificate : ISO 9001:2015, ISO 14001:2015, ISO 18001,OHSAS 18001. CE Certification: IEC/ EN 62040-1-1, IEC/EN50091- 1,IEC/EN 60950(Safety),IEC/ EN 5009 I-2,IEC/ EN 62040-2 (EMC Emmission), IEC/EN 62040-3 (Performance & Design), IEC/EN 61000-4(EMC Emmunity) & IEC/ EN 60146 (Design & Manufacture) Make: APC-Schneider Electric / NUMERIC/ Power One/ VERTIV/ Switching AVO/ Powersafe/ Delta/Better Power/ Prostarm.
TERMS & CONDITIONS
(i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST. (ii) All materials, equipments & accessories must conform to relevant IS / IEC specifications. (iii) Necessary manufacturer's warranty certificate will have to be submitted during delivery of the material. iv) 2 years Full Comprehensive warranty on both UPS and Battery from the date of Installation. v) OEM/Bidder must have local service center / service engineer within Malda pin code area (For any verification: Authentic documents to be attached with last 3 months salary slip & PF no).
Prostarm Info Systems limited (BID ID -6865638)
WISE CHOICE (BID ID -6854318)
Rajalakshmi Enterprise (BID ID -6854278)
B. ENGINEERING CO. (BID ID -6862191)
ASIM KRISHNA MODAK (BID ID -6858448)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .