| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC 0 BETTER POWER SERVICES PVT LTD A K AZAD ROAD REHABARI KAMRUP ASSAM 781008 UDYAM AS 03 0002019 19AADCB7283J1Z9 B 29AADCB7283J1Z8 B 18AADCB7283J3Z9 M 16AADCB7283J1ZF B 18AADCB7283J3Z9 B R MII STATUS AS VERIFIED | KAMRUP METRO | ASSAM | 781008 | ₹8.7 L | L1 | Accepted-AOC Quoted rate found Lowest (L1). |
| 2 | L2₹9.6 LRejected-Finance 321 PATIL NAGAR BAWDHAN ROAD BAVDHAN BUDRUK PUNE MAHARASHTRA 411021 UDYAM MH 33 0055257 | PUNE | MAHARASHTRA | 411021 | ₹9.6 L | L2 | Rejected-Finance Quoted rate found 2nd Lowest (L2). |
| 3 | L3₹12.7 LRejected-Finance 685 SONARPUR STATION ROAD GREEN PARK KOLKATA 700103 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700103 | ₹12.7 L | L3 | Rejected-Finance Quoted rate found 3rd Lowest (L3). |
| 4 | L4₹12.9 LRejected-Finance | ₹12.9 L | L4 | Rejected-Finance Quoted rate found 4th Lowest (L4). |
| 5 | L5₹13.3 LRejected-Finance VILL DAKSHIN SHIBGANJ P O AND P S PATHARPRATIMA DIST SOUTH 24 PARGANAS | SOUTH 24 PARGANAS | WEST BENGAL | ₹13.3 L | L5 | Rejected-Finance Quoted rate found 5th Lowest (L5). |
| Sl No | Description | Qty | Unit | Prostarm Info Systems limited L2 | Better Power Services Pvt.Ltd. L1 | Rajalakshmi Enterprise L4 | WISE CHOICE L3 | B. ENGINEERING CO. L5 | ASIM KRISHNA MODAK L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00SITC of 30 KVA UPS including Battery Bank of (21371 ~ 24960) VAH or higher (SMF Battery 12 Volt, 45AH ~125AH) 3ph Input /3ph Output, Static by-pass arrangement, compitable with D.G.Set, DSP controlled IGBT based rectifier with minimum 90% efficiency on 100% Load. The UPS shall be provided with active input P.F. Correction system to obtain 0.9 lag at 100% resistive Load, Wave form - Pure sine wave. Crest Factor- 3:1 It Should be capable of operating in 50'c above ambient temprature, Built in Solid State float cum boost charger with automatic boost / trickel charge mode with current Limiting features. The charger should be designed for at least 15% of the total battery current. The UPS Should have current limiting protection, built in over load / Short circuit protection with snubber circuits for current limit. Soft start arrangement, Over voltage / under voltage protection, mains ON, Inverter ON/ OFF/ FAULTY/ TRIP (Reason), Charger ON/ FAULTY or TRIP, Battery Low, Static by-pass ON, Over temperature. Inbuilt Isolation Transformer of 1:1 ratio connected in Delta- Star Mode. Battery set Complete with self-standing cubicle or cabinet. The UPS should have external automatic load transfer switch for parallel operation. | |||||||||
| 1.01 | Regulated Sealed Lead Acid Battery, Construction type : AGM or VRSLAB in ABS Flame Retardant Rating (12V SMF Battery - 45AH ~125AH) (Battery Make Amararaja /Quntra/Exide Power Safe. Back-up time: 30 Min at full load. Warranty : One Year on UPS and One Year on SMF Battery on-site against any manufacturing defects. Certificate : ISO 9001:2015, ISO 14001:2015, ISO 18001,OHSAS 18001. CE Certification: IEC/ EN 62040-1-1, IEC/EN50091- 1,IEC/EN 60950(Safety),IEC/ EN 5009 I-2,IEC/ EN 62040-2 (EMC Emmission), IEC/EN 62040-3 (Performance & Design), IEC/EN 61000-4(EMC Emmunity) & IEC/ EN 60146 (Design & Manufacture)
Make: APC-Schneider Electric / NUMERIC/ Power One/ VERTIV/ Switching AVO/ Powersafe/ Delta/Better Power/ Prostarm. | 2 | Nos | 4,79,320 ₹9.6 L | 4,35,000 ₹8.7 L | 6,43,300 ₹12.9 L | 6,33,696 ₹12.7 L | 6,63,730 ₹13.3 L | 7,19,500 ₹14.4 L |
| 2.00TERMS & CONDITIONS | |||||||||
| 3.00(i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST. (ii) All materials, equipments & accessories must conform to relevant IS / IEC specifications. (iii) Necessary manufacturer's warranty certificate will have to be submitted during delivery of the material. iv) 2 years Full Comprehensive warranty on both UPS and Battery from the date of Installation. v) OEM/Bidder must have local service center / service engineer within Malda pin code area (For any verification: Authentic documents to be attached with last 3 months salary slip & PF no). | |||||||||
Tender Value
Refer Docs
EMD Value
₹29,400
Closing Date
26 Aug 2025, 3:00 pmClosed
EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION
O/O THE EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION Singatala Malda PIN 732101
Construction of G plus 3 Storied Building for 50 beded Critical Care Block at Malda Medical College and Hospital, Malda - SITC of UPS
2025_WBPWD_888551_1
WBPWD/EE/MED/e-NIQ-21/2025-26
Open Tender
Electrical Work/ Equipment
15 days
Malda
Please refer Tender documents.
6 documents required · 6 mandatory
₹29,400
Yes
13 Mar 2026
7 Aug 2025
28 Aug 2025
7 Aug 2025
26 Aug 2025
13 Aug 2025
Amount
SITC of 30 KVA UPS including Battery Bank of (21371 ~ 24960) VAH or higher (SMF Battery 12 Volt, 45AH ~125AH) 3ph Input /3ph Output, Static by-pass arrangement, compitable with D.G.Set, DSP controlled IGBT based rectifier with minimum 90% efficiency on 100% Load. The UPS shall be provided with active input P.F. Correction system to obtain 0.9 lag at 100% resistive Load, Wave form - Pure sine wave. Crest Factor- 3:1 It Should be capable of operating in 50'c above ambient temprature, Built in Solid State float cum boost charger with automatic boost / trickel charge mode with current Limiting features. The charger should be designed for at least 15% of the total battery current. The UPS Should have current limiting protection, built in over load / Short circuit protection with snubber circuits for current limit. Soft start arrangement, Over voltage / under voltage protection, mains ON, Inverter ON/ OFF/ FAULTY/ TRIP (Reason), Charger ON/ FAULTY or TRIP, Battery Low, Static by-pass ON, Over temperature. Inbuilt Isolation Transformer of 1:1 ratio connected in Delta- Star Mode. Battery set Complete with self-standing cubicle or cabinet. The UPS should have external automatic load transfer switch for parallel operation.
Regulated Sealed Lead Acid Battery, Construction type : AGM or VRSLAB in ABS Flame Retardant Rating (12V SMF Battery - 45AH ~125AH) (Battery Make Amararaja /Quntra/Exide Power Safe. Back-up time: 30 Min at full load. Warranty : One Year on UPS and One Year on SMF Battery on-site against any manufacturing defects. Certificate : ISO 9001:2015, ISO 14001:2015, ISO 18001,OHSAS 18001. CE Certification: IEC/ EN 62040-1-1, IEC/EN50091- 1,IEC/EN 60950(Safety),IEC/ EN 5009 I-2,IEC/ EN 62040-2 (EMC Emmission), IEC/EN 62040-3 (Performance & Design), IEC/EN 61000-4(EMC Emmunity) & IEC/ EN 60146 (Design & Manufacture) Make: APC-Schneider Electric / NUMERIC/ Power One/ VERTIV/ Switching AVO/ Powersafe/ Delta/Better Power/ Prostarm.
TERMS & CONDITIONS
(i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST. (ii) All materials, equipments & accessories must conform to relevant IS / IEC specifications. (iii) Necessary manufacturer's warranty certificate will have to be submitted during delivery of the material. iv) 2 years Full Comprehensive warranty on both UPS and Battery from the date of Installation. v) OEM/Bidder must have local service center / service engineer within Malda pin code area (For any verification: Authentic documents to be attached with last 3 months salary slip & PF no).
Prostarm Info Systems limited (BID ID -6865638)
WISE CHOICE (BID ID -6854318)
Rajalakshmi Enterprise (BID ID -6854278)
B. ENGINEERING CO. (BID ID -6862191)
ASIM KRISHNA MODAK (BID ID -6858448)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid