| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC RAMA PARK A 121 BLOCK A UTTAM NAGAR WEST DELHI DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC being lowest | |
| 2 | L2₹21.0 L+₹52,315 (2.55%)Rejected-Finance G 86 DATA RAM SECTOR 18 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹21.9 L+₹1.4 L (6.88%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹22.2 L+₹1.7 L (8.18%)Rejected-Finance E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹26.7 L+₹6.2 L (30.3%)Rejected-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹28.6 L
EMD Value
₹57,200
Closing Date
31 Jan 2020, 6:00 pmClosed
GE (N) Delhi Cantt-10
GE (N) Delhi Cantt-10
REPAIR MAINT OF LT DISTRIBUTION SYSTEM AND SECURITY STREET LIGHTS WITH CONNECTED WORKS AT ANAND PARBAT UNDER GE NORTH DELHI CANTT 10
2020_MES_311989_1
GE/NORTH-72/2019-20
Open Tender
Civil Works
Works
120 days
GE (N) Delhi Cantt-10
MES contractor enlisted under Category Class D and Category b(i)
having deposited Standing Security of Rs 100000 with department Contractors not enlisted in MES should meet the MES enlistment criteria corresponding
8 documents required · 8 mandatory
₹500
Yes
GE (N) Delhi Cantt-10
₹57,200
Yes
28 Feb 2020
4 Jan 2020
1 Feb 2020
4 Jan 2020
31 Jan 2020
15 Jan 2020
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5m depth for laying under ground cable/pipes in loose/soft soil all as specified and directed.
All as per item No.01 but Hard/dense soil.
All as per item No.01 but Soft/disintegrated rock.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
M&L for sand cushioning for protection of cables with screen wash river sand and punning to proper required cover all as specified and directed.
M&L for bricks of sub class ‘B’ bricks, for cable protection in trenches laid dry and flat all as specified and directed.
Supply and laying, testing and connecting XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core, laid in trecnhes or fixed to pole/wall complete all as specified and directed.
All as per Item No 08 above but 16 Sqmm 4 Core.
All as per Item No 08 above but 25 Sqmm 3.5 Core.
All as per Item No 08 above but 50 Sqmm 3.5 Core.
All as per Item No 08 above but 95 Sqmm 3.5 Core.
All as per Item No 08 above but 120 Sqmm 3.5 Core.
Taking down UNSV cable/conductor from exist / poles/LT panels where required all as specified and directed.
Laying only (Re routing) serviceable any type of cable up to 70 sqmm 3 ½ /4 core size all as specified and directed. (Note:- Excavation, sand, bricks and connected items shell be measured and paid separately).
All as per above item No 15 but 95 sqmm to 240 sqmm.
Laying only old bricks over the sand cushioning dry and flat for cable protection complete all as directed.(Note:- Bricks obtained from the removing of UNSV cable/re routing of cable)
M & L for Hardcore of gauge n exc. 40 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
Supply and laying in replacement of synthatic insulating mat of size 2m x 1m x 12 mm all as specified and directed.
All as per item No 19 above but size 2m x 1m x 25 mm.
M & L in repair for PCC root indicator made of PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate suitable for mounting on root of UG cables/Pipe of width 45cm, depth 10cm & height 100cm overall embedded to the depth not less than 45cm below ground level complete all as specified & directed.
M & L for writing letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high with synthetic enamel paint as per colour scheme all as specified. Complete all as specified and directed.
M&L for steel tubular swaged poles complete with cast iron base plate final taper plug bolts, nuts & screw all as specified and directed Type 410 SP 31 (9 Mtrs long) with two coat of aluminium paint over a coat of red oxide primer in full length of the pole with black and yellow strip up to 1.5 mtr over PCC coping alternatively including numbering the pole and necessary excavation incl dismantling the unserviceable PCC pole with fittings etc complete.(Note: Excavation, demolition of concrete, PCC for foundation, coping and connected items shall be measured and paid separately under relevant items).Complete all as specified and directed.
M&L for dismantling of PCC/Steel tubling pole upto 11 mtrs length including disconnecting of electric supply from existing security light poles with connected accessories with breaking of plinth, shifting and fixing of same pole relocated at specified site and all as directed. (Note: Earth work and PCC shall be measured and paid under relevant items).
Demolition of cement concrete of any description and in any position. Complete all as specified and directed.
M&L for PCC (1:4:8) type D2,( using 40 mm graded aggregate) as in foundations, filling and mass concrete Complete all as specified and directed.
M&L for PCC (1:3:6) type C1, (Using 20 mm graded aggregate) as in foundations, for coping, filling and mass concrete with cement plastering finishing all as specified and directed.
M & L for Cutting of road/path depth up to 0.45m for laying of GI tubing dia upto 100 mm and making the good to disturbed road/ path including provision of PCC 1:2:4 type B-1 using 20mm graded stone aggregate all as specified and directed.
M & L in repairs for steel tubes, light grade galvanised 100 mm bore laid in trenches/walls and spreading for cable cushioning/protection all as specified and directed.
All as per above item No 29 but 80 mm bore.
All as per above item No 29 but 50 mm bore.
All as per above item No 29 but 40 mm bore.
M&L ifor tubes "light grade galvanised 25 mm with all fiiting and fixed complete to wall /pole and remove the UNSV same and all as specified and directed.
M&L for street light bracket suitable for street/security light fittings upto 1.5 RM make out of GI pipe of light grade up to 32/40 mm dia proper shaped, bended, threaded and drilling holes for wire entry and MS clamp of suitable size in proper shape and designed including taking down old corroded one all as directed and specified .
M&L for PVC, sheathed copper cable of 2.5 sqmm, 3 core for street light connection including taking down unserviceable PVC insulated aluminium conductor cable from steel pole /PCC pole /Jn box all as specified and directed.
Material & Labour in repairs for cross arms, bracings, supports, clamps, angle iron, flats and back plates febricated from MS structural steel sections including nuts, bolts and washers of suitable sizes including welding, bending (cold or hot), drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer, complete all as specified and directed.
Supply, Install , testing and commissioning of Street light panel of max load 12 KW, including contactor rating 65A, MCB rating 63A TPN suitable for 3 Phase 415 Volts outdoor with panel locking facility, wall/Floor mounted type, incl necessary cable lugs qnd glands in repairs all as specified and directed.Make- Havell's Cat Part No IHXTS09120 or Indo asian/L&T
Supply and fixing New street light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 66 protection and 25 Watt including taking down old unserviceable one all specified and directed
Supply and fixing New street light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 66 protection and 60 Watt including taking down old unserviceable one all specified and directed .
Supply and fixing New large area flood lighting system LED type IP 66, pressure die cast housing, with heat resistant tempered glass for protection with surge protection system, 120 Watt including taking down old unserviceable one all specified and .
Supply and fixing for decorative LED post top fittings 25W Ruby Clear/Coral opal type IP 65 including with all accessories complete along with after taking down old unserviceable one all specified and (Note: light grade GI pipe and necessary PCC works shall be measured and paid separately under relevant items)
Supply and fixing garden light fitting 10 watts, IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution including taking down old fitting, demoliton of brick/PCC work all as specified and directed. (Note: Necessary PCC works shall be measured and paid separately under relevant items)
M&L for loop box out door type made out of Engineering plastic one piece moulding type,Bus bar rating 63 Amps 4 strips aluminium with bus bar mounting colour R,Y,B,N on DMC unbreakable insulator with cable entry main supply from bottom side and pole light connection from back side, simens grey colour, shock prrof, rust proof, fire retardant size 300x 200x 100mm with 10 Amps Kit kat fuse type, having front, opening and locking arrangement, duly fixed on the pole by MS clamp of suitable sizes, including taken des unsv all as specified and directed by Engineer –in- Charge. (Note:- Incoming and outgoing cables suitable size Lugs,Glands rate deemed to be included) (Make- Unilac/Universal switch gear control/Tricolite)
All as per Srl No -43 here in before but Single phase system 2 strips aluminium bus bar size of 200x150x100mm all as specified and directed.
S & F in replacement of MCCB, 4 pole, 415V AC, fixed type of following capacity;
63Amps with breaking capacity 16kA
100 Amps with breaking capacity 16kA
125Amps with breaking capacity 16kA
160 Amps with breaking capacity 25kA
Supply, install, testing and commissioning of factory made LT panel of size not less than 145cm x 90 cmx 60 cm for 3 phase 415 Volts outdoor type cubical compartmentalised vermin and water proof fabricated out of 3.15mm thick CRCA sheet powder coated front and back door openable with locking arrangement, necessary ventilation, suitable for including 200 Amps rated Aluminium bus bar, insulated with PVC sleaves and coloured with (Red, Yellow, Blue and Black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6mm frame bottom of the panel board, 0.45 mtrs length legs(04Nos) grouted by using PCC foundation 1:2:4 type C1 using with 20mm graded stone aggregate, thimbling and cable entry boxes with cable gland including painting with two coat of powder coated painting over a coat of red oxide primer after dismanteling the existing LT panel complete with following incoming/out going accessories:- (Make- Unilac/Universal switch gear control/Tricolite/Unilac)
IN COMING
(a) MCCB 4 Pole, 415 volts, 160 Amps 25 KA - 01 No
OUT GOINGS
(a) MCCB 4 Pole, 415 volts, 40 Amps 10 KA - 04 Nos
(e) Indicator lamp (set of 3)- 01 set
Supply, install, testing and commissioning of factory made LT panel of size not less than 1800cm x 900 cmx 600 cm for 3 phase 415 Volts outdoor type cubical compartmentalised vermin and water proof fabricated out of 3.15mm thick CRCA sheet powder coated front and back door openable with locking arrangement, necessary ventilation, suitable for including 300 Amps rated Al bus bar, insulated with PVC sleaves and coloured with (Red, Yellow, Blue and Black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6mm frame bottom of the panel board, 0.45 mtrs length legs(04Nos) grouted by using PCC foundation 1:2:4 type C1 using with 20mm graded stone aggregate, thimbling and cable entry boxes with cable gland including painting with two coat of powder coated painting over a coat of red oxide primer after dismanteling the existing LT panel complete with following incoming/out going accessories:- (Make- Unilac/Universal switch gear control/Tricolite)
IN COMING
(a) MCCB 4 Pole, 415 volts, 250 Amps 35 KA - 01 No
OUT GOINGS
(a) MCCB 4 Pole, 415 volts, 125 Amps 25 KA - 01 Nos
(b) MCCB 4 Pole, 415 volts, 32 Amps 10 KA - 04 Nos
(c) MCB TPN, 415 volts, 32 Amps.10KA - 01 Nos
(d) MCB SPN, 240 Volts, 32 Amps of 10 KA- 04 Nos
(g) Indicator lamp (set of 3)- 01 set
Supply, install, testing and commissioning of factory made LT panel of size not less than 450cm x 450 cmx 300 cm for 3 phase 415 Volts outdoor type cubical compartmentalised vermin and water proof fabricated out of 3.15mm thick CRCA sheet powder coated front door openable with locking arrangement, necessary ventilation, suitable for including 100 Amps rated Al bus bar, insulated with PVC sleaves and coloured with (Red, Yellow, Blue and Black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6mm frame bottom of the panel board, wall mounted type , thimbling and cable entry boxes with cable gland including painting with two coat of powder coated painting over a coat of red oxide primer after dismanteling the existing LT panel complete all as specified and directed. (Make- Unilac/Universal switch gear control/Tricolite)
Supply, install, testing and commissioning of factory made LT panel of size not less than 1200cm x 900 cmx 600 cm for 3 phase 415 Volts outdoor type cubical compartmentalised vermin and water proof fabricated out of 3.15mm thick CRCA sheet powder coated front and back door openable with locking arrangement, necessary ventilation, suitable for including 300 Amps rated Al bus bar, insulated with PVC sleaves and coloured with (Red, Yellow, Blue and Black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6mm frame bottom of the panel board, 0.45 mtrs length legs(04Nos) grouted by using PCC foundation 1:2:4 type C1 using with 20mm graded stone aggregate, thimbling and cable entry boxes with cable gland including painting with two coat of powder coated painting over a coat of red oxide primer after dismanteling the existing LT panel complete with following incoming/out going accessories:- (Make- Unilac/Universal switch gear control/Tricolite)
IN COMING
(a) MCCB 4 Pole, 415 volts, 250 Amps 35 KA - 01 No
OUT GOINGS
(a) MCCB 4 Pole, 415 volts, 100 Amps 25 KA - 04 Nos (Havells/ Legrand)
(d) Indicator lamp (set of 3)- 01 set
Supply, install, testing and commissioning of factory made LT panel of size not less than 1200cm x 900 cmx 600 cm for 3 phase 415 Volts outdoor type cubical compartmentalised vermin and water proof fabricated out of 3.15mm thick CRCA sheet powder coated front and back door openable with locking arrangement, necessary ventilation, provision for cables side entry suitable for including 160 Amps rated Al bus bar, insulated with PVC sleaves and coloured with (Red, Yellow, Blue and Black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6mm frame bottom of the panel board, 0.45 mtrs length legs(04Nos) grouted by using PCC foundation 1:2:4 type C1 using with 20mm graded stone aggregate, thimbling and cable entry boxes with cable gland including painting with two coat of powder coated painting over a coat of red oxide primer after dismanteling the existing LT panel complete with following incoming/out going accessories:- (Make- Unilac/Universal switch gear control/Tricolite)
IN COMING
(a) MCCB 4 Pole, 415 volts, 100 Amps 25 KA - 01 No (Havells/ Legrand)
OUT GOINGS
(a) MCB SPN, 240 Volts, 32 Amps of 10 KA- 12 Nos (Havells/Legrand)
(d) Indicator lamp (set of 3)- 01 set
Supply, install, testing and commissioning of factory made LT panel of size not less than 600cm x 600 cmx 600 cm for 3 phase 415 Volts outdoor type cubical compartmentalised vermin and water proof fabricated out of 3.15mm thick CRCA sheet powder coated front and back door openable with locking arrangement, necessary ventilation, provision for cables bottom entry suitable for including 100 Amps rated Al bus bar with DMC insulators, insulated with PVC sleaves and coloured with (Red, Yellow, Blue and Black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6mm frame bottom of the panel board, 0.50 mtrs length legs(04Nos) grouted by using PCC foundation 1:2:4 type C1 using with 20mm graded stone aggregate, thimbling and cable entry boxes with cable gland including painting with two coat of powder coated painting over a coat of red oxide primer after dismanteling the existing LT panel complete with following incoming/out going accessories:- (Make- Unilac/Universal switch gear control/Tricolite)
(a) MCCB 4 Pole, 415 volts, 63 Amps 16 KA - 01 No (Havells/ Legrand)
(d) Indicator lamp (set of 3)- 01 set
M&L for disconnecting of all elecric supply, taking out electric incoming and out going cables from existing LT feeder piller of any size and any type, powder coated painting over a cleaning, scrabing with salt paper and removal of dust particles complete with necessary T&P, and refixing the same as incoming and outgoing cables as existing.
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron wire of 4 mm dia as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified fixed in repair and shown in electrical plate No 5 of SSR 1991(Part-I) complete all as specified and directed .
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron strip of size 25 X 4mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified fixed and repair and shown in electrical plate No 5 of SSR 1991(Part-I) complete all as specified and directed.
Material & labour for earthing with Copper earth plate electrode 60cm x 60cm x 3.15 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using copper strip of size 20X3 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified fixed and repair and shown in electrical plate No 5 of SSR 1991(Part-I) complete all as specified and directed.
S & F earth continuity conuctor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit/pipe or fixed to the pole or any other situation for loop earthing etc as required 4mm dia galvanised iron wire. All as per specified and directed.
Supply and fixing earth continuity conductor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit/pipe or fixed to the pole or any other situation for loop earthing etc as required 25x4mm GI strip all as specified and directed.
Supply and fixing earth continuity conductor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit/pipe or fixed to the pole or any other situation for loop earthing etc as required 20x3mm copper strip all as specified and directed.
Sch of Credit- Total contract sum shall be calculated after deduction of Sch of Credit amount Credit amount - Rs.84170.00
NEETU TRADERS (INDIA)
Shiv Enterprises
PRASAD ELECTRICALS
Rahul Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .