Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical document are not as per requirement |
Tender Value
Refer Docs
EMD Value
₹4,000
Closing Date
5 Jan 2021, 5:00 pmClosed
EE,ECD(D),GomtiNagar, MVVNL
Type-4/95 Indralok Hydle Colony Krishna Nagar, Lucknow
For Extension of Varandha, Internal Painting and Other Misc Civil Work at Office of The EE Sandila District Hardoi
2020_MVVNL_541780_1
77/ ECD(D)GN/L/E-Tender/ 2020-21
Open Tender
Miscellaneous Works
Fixed-rate
30 days
Hardoi
As per tender document
2 documents required · 2 mandatory
₹295
A/CNo.-1277785019,IFCS Code- CBIN0280140
₹4,000
29 Jan 2021
30 Dec 2020
6 Jan 2021
30 Dec 2020
5 Jan 2021
30 Dec 2020
Amount
Excavation in foundation in ordinary soil (Loam clay or sand) including lift upto 1.5 mtr. and lead upto 30 m and including filling watering and ramming of excavated earth into the trenches or into the space between the building and sides of the foundation trenches or in to the plinth and removal and disposal of surplus earth as directed by the Engineer-in-Charge upto a distance of 30 m from the foundation trenches.
Add to item 6.01 to 6.06 above for extra labour in super structure including necessary cutting and moulding of bricks as required and also including honeycomb brick work, thickness of wall not to be less than 1.5 brick. (CSI No. 6.07)
Ist class brick work in 1:6 cement & coarse sand (F.M. 1.8 to 2.5) mortar in foundation & plinth including supply of all materials, labour and T&P etc. required for proper completion of work.
First class brick (class-150) work in 1:6 cement and coarse sand (F.M.1.8 to 2.5) mortar in super structure including supply of all materials, labour & T&P etc. required for proper completion of work, thickness of wall not to be less than 1.5 brick
Mild Steel or Iron work in heavy sizes such as trusses built up gates, door frames, record, racks roof work gates etc. wrought to required form including holes rivetting or welding where necessary and also fixing in proper position and alignment including cost of all materials supplied by contractor.
RCC work with cement approved coarse sand (F.M. 1.8 to 2.5) and 2 cm gauge graded approved hard stone ballast like grainite, quartzite etc from Dalla, Jhansi or other quarries and approved coarse sand in proportion 1:1.5:3 in lintels of doors and windows, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P.
RCC work with cement approved coarse sand (F.M. 1.8 to 2.5) and 2 cm gauge graded approved hard stone ballast like grainite, quartzite etc from Dalla, Jhansi or other quarries and approved coarse sand in proportion 1:1.5:3 in slab, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P . (CSI No. 5.24)
Repair to 2.5 cm (1") cement concrete floor in patches including up to 10 cm.(4") depth renewing 8 cm.(3") base concrete consisting of one part cement, 4 parts aproved coarse sand and 8 parts of 4 cm.(1.5") gauge brick ballast as in C.C.floor consisting of one part cement 2 parts approved coarse sand and 4 parts approved stone grit including supply of all materials.labour and T&P etc. required for proper completion of the work. (CSI No. 20.03)
6 mm. thick plaster with 1:3 cement & coarse sand including labour, materials & T&P etc. required for proper completion of the work.
3 mm thick floating coat of neat cement finish including supply of all materials,labour and T&P etc. required for proper completion of the work. (cement consumtion 0.044 bag/Sq.m.)
Concrete with 4cm gauge I class brick ballast (class 150) , coarse sand (F.M. 1.8 to 2.5) and cement in proportion of 12:6:1 in foundations and under floors including supply of all materials, labour and tools and plants etc. required for proper completion. (CSI No.5.01 )
12 mm thick plaster with cement mortar consisting of one part of cement & six part of coarse sand(1:6),minimum thickness not to be less then 10 mm including supply of all material, labour and T&P etc for proper completion of work.
12 mm thick plaster rough surface with cement mortar consisting of one part of cement & six part of coarse sand(1:6), minimum thickness not to be less then 10 mm including supply of all material, labour and T&P etc for proper completion of work.
Painting or varnishing old iron work in small areas or old wood work with one coat of ready mixed priming paint and two coat of approved superior quality ready mix paint "Luxol" or equivalent brand or varnish including supply of all materials, labour and T&P etc. required for proper completion of the work. Paint to be used should conform to theI.S. 103-1950.
Applying Birla or equivalent putty on new interior or exterior surface over one coat of water based cement primer of ICI or equivalent brand for smoothening and levelling of the surface as per requirement and direction of Engineer I/C including cost of all material, labour, T & P etc required for proper completion of work. (CSI No. 13.20)
Applying BIRLA PUTTY or equivalent putty on previousaly bila putty smoothen surface over one cost of water base cement primer of ICI or equivalent brand for smoothining and leveling of the surface as per requirement and direction of E/I including cost of all material , labour and T&P required for proper completion of work.(CSI No.13.21)
Same as in item 13.22 but for each coat of APEX or equivalent brand weather coat paint .on previously treated surface. (CSI No. 13.24)
Same as in item no 13.22 above but for every coat of additional APEX or equivalent brand weather coat paint . (CSI No. 13.23)
Same as in item 13.17 but for each coat of water proof cement paint. on previously treated surface. (CSI No. 13.19)
One priming coat and one coat oil bound distemper on new work including supply of all materials,labour and T&P etc. required for proper completion of the work. (CSI No. 13.08)
As in item 13.08 but for every coat after the first coat. (CSI No. 13.09)
As in item 13.08 but for every coat on previously old oil bound distemper surface. (CSI No. 13.10)
Supply and Laying 6 mm thick glazed tiles of size 300x450 mm in skirting / dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry, jointing and polishing complete,including supply of all materials, labour and T&P etc. completion required for proper completion of the work. (CSI No. 12.12)
Supply and Laying 8 mm thick white glazed floor tiles of Somany, Johnson or equivalent make, of size 300x300 mm, laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry, jointing and polishing complete, including supply of all materials, labour and T&P etc. completion required for proper completion of the work.
TMT/Tor steel in plain work such as reinforced concrete or reinforced brick work (when not included in an over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage, bend, hooks and authorized overlapping shall be measured. (Steel shall be arranged by the contractor)
Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe on surface, complete with 14 SWG copper earth continuity wire,GP Box ,piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect, as directed .
Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe on surface complete with 14 SWG copper earth continuity wire, piano type switch & ceiling rose on 3 mm. thick phenolic laminated backelite sheet etc, complete in all respect.
Wiring Point for plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe on surface,complete with 14 SWG copper earth continuity wire , GP Box and piano type switch and socket etc. complete in all respect
Wiring point for exhaust fan/Power Plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe on surface complete with14 SWG copper earth continuity wire, 15 A piano type switch & ceiling rose on 3 mm.thick henolic laminated backelite sheet etc, complete in all respect.
Supply and fixing of 110 mm dia PVC pipe 4 Kg./ Sq.cm for water supply mains & rain water pipe of Tirupati or equi. Make with special such as Tee, bend, socket, elbow etc. including cutting of pipe where necessary and including excavation of trenches for laying the pipe line of approved size (600 x 900 mm) and including its back filling after testing the pipe line , watering, ramming etc complete including disposal of surplus earth from the sides upto 100 mtr as per direction of Engineer incharge as required for proper completion of work.
Providing and fixing steel glazed window and ventilators of standard rolled Mann or Mahavir steel sections conforming to IS 7452-1974 as per drawing joints metered & welded with 100x14x3.15 mm holdfast embedded in cement concrete block 15x10x10 cm. Size of 1:3:6 proportion I.E. First part of cement 3 part of approved coarse sand & 6 part of graded stone (aggregated 20mm. Nominal size) S/F of glass panes of plain pin headed 4mm. Thick nuts glazing clips and special putty of approved make complete and including a cost of red oxide paint. The fabrication should conform to I.S.1038-1975. (Aluminum beading with rubber packing included).
Providing and Fixing 16 mm dia PVC Pipe PPR Plumbing System, Non Resting, Anti Microbial, PPR Pipe PN 16/SDR, ISI Marked including supply of all material, labour and T&P etc. required for proper completion of work
Providing and Fixing 25 mm dia PVC Pipe PPR Pipe PN 16/SDR, ISI Marked including supply of all material, labour and T&P etc. required for proper completion of work
Providing and Fixing 25 mm dia PVC full way gate valve, ISI Marked including supply of all material, labour and T&P etc. required for proper completion of work
P/FBRASS BIB COCK, 15 mm dia (200 gms) ISI mark heavy quality including supply of all materials, labour and T&P required for proper completion of work.
Supply and fixing P.V.C. cistern Hindustan or equivalent make 10 litres. Capacity complete with all accessories (Low level) including all materials, labour and T&P etc. complete.
Providing and fixing 100 mm dia PVC "P" or "S" trap including cement concrete and all materials, labour cartage T&P etc.required for proper completion of the work.(For W.C.) (CSI No. 27.24)
Supply and fixing Syntex or equivalent make water storage tank including all materials, labour and T&P etc. required for the proper completion of the work.
Providing and fixing white glazed earthen ware W.C. "Orissa" Pan Hindustan make of size (58×44)cm including supply of all materials, labour and T&P etc. required for proper completion of the work.
S/F of 63 amp. DP MCB (10 KA)
S/F Batten/Angle Holder/Ceiling rose of approved quality complete in all respect .
Supply and fixing of 6 Amp. To 32 amp. DP MCB (10 KA) C Curve
Engaging of labour for misc. civil works with required T&P
Note :- 1 GST Will paid only extra as applicable. 2 Quantity of individual item may increase or decrease to any extent as per site condition 3 Dismantling item work if recovery required it deducted from contractor bill’s 4 All the item rates including labour cess, no extra payment shall be done.
M/S SHREE BALAJI ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .