Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
30 Nov 2026, 11:00 am
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
CSTECONHQ
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of "V/N" or "V" whichever is less; whereV= Advertised value of the tender in crores of RupeesN= Number of years prescribed for completion of work for which bids have been invited.The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.The tenderers shall submit requisite information as per Annexure-D (As per GCC, 2022), along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited:a) Three similar works each costing not less than the amount equal to 30% of advertised value of the tenderb) Two similar works each costing not less than the amount equal to 40% of advertised value of the tenderc) One similar work costing not less than the amount equal to 60% of advertised value of the tender
13 conditions · 1 needing a document upload
As per Tender Document attached
The tendered should submit the following documents/papersalong with tender document a.List of personals, plant, tools &Machinery available on hand (own) and proposed to be inducted(own and hired to be given separately) for the subject work.b.List of works completed in last three financial years givingdescription of work, organization for whom executed,approximate value of contract, date of award and date ofcompletion of work, duly certified by the organization with whomthe tenderer had worked. c.List of work on hand indicatingdescription of work, contract value, date of award duly certifiedby the organization with whom the tenderer had worked. TheRailways Administration reserves the right to reject any or alltenders in full or part without assigning and reasons thereof.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Signalling & Telecommunication work for Trenching & Laying of Underground 6- Quad/Signal/Power cable, Casting, Curing of foundations, Erection of CLS Equipments & Apparatus Case along with Modification, Wiring, Testing & Commissioning of Neale's Ball Token Instrument at Numaligarh Siding under TSK division and EI Alteration Works at Gohpur in connection with Tower Wagon Siding works for 25 KV RE Modification works under RNY division of N.F.Railway
NFR_C_RE_SnT_2026_1~NFRCON
NFR_C_RE_SnT_2026_1
Open
Works - General
180 Days
Unknown (Unspecified Location)
₹0
₹3.0 L
4 Nov 2026
4 Nov 2026
16 Nov 2026
242 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 24,44,976.47 | ||
| — | 20.00 | — | — | ||
| Supply of Non detoriating type low voltage cartridge electric fuse 2 Amps with cyndrical head end cap as per Spec No. IRS/S/78/92 with latest amendments | — | — | — | 4,219.6 | |
| — | 20.00 | — | — | ||
| Non deteriorating type of low voltage electric fuse of 6A along with base for railway Signaling as per specification IRS: S-78/2006 or latest. | — | — | — | 5,774 | |
| — | 20.00 | — | — | ||
| Non deteriorating type of low voltage electric fuse of 16A along with base for railway Signaling as per specification IRS: S-78/2006 or latest. | — | — | — | 5,575.8 | |
| — | 20.00 | — | — | ||
| Supply of PVC insulated multi strand, single core copper conductor of size 16/0.2 mm (0.5 sqmm) as per IS 694: 2010 and RDSO Specn. No. IRS: S-76/89 (Amnd-3) or latest. One Coil should be of 100 meters length. PVC coated in different colours as per technical specifications. Color of the wire which is required will be specified by the Engineer in charge. | — | — | — | 19,959.6 | |
| — | 200.00 | — | — | ||
| PVC insulated cable 3/16" as per IRS specification S: 103-2004 made of copper alloy material tin plated non corrosive. | — | — | — | 49,596 | |
| — | 2.00 | — | — | ||
| Supply of PVC insulated unsheathed single core bright annealed bare copper conductor flexible cable (Size 2.5 Sq.mm) for voltage grade up-to 1100V confirming to IS: 694/1990 or latest. It is to be supplied in the coil of 100 meters. | — | — | — | 7,752.54 | |
| — | 2.00 | — | — | ||
| Supply of PVC insulated unsheathed single core bright annealed bare copper conductor flexible cable (Size 4 Sq.mm) for voltage grade up-to 1100V confirming to IS: 694/1990 or latest. It is to be supplied in the coil of 100 meters. | — | — | — | 11,097.78 | |
| — | 2.00 | — | — | ||
| Supply of 1 x 6 Sq.mm. (Red/Black/Green) multi strand copper power wire as per IS: 694:2010 or latest, 84 conductor each dia 0.30mm +/- 0.01 with insulation thickness of 0.8 mm and nominal conductor resistance of 3.3 ohms/km and test parameters as per RDSO Specn. No. IRS:S 76/89 (Amnd.3) or latest. Color of the wire which is required will be specified by the Engineer in- charge. One Coil should be of 100 meters length. | — | — | — | 18,237.66 | |
| — | 2.00 | — | — | ||
| Supply of 1 x 10 Sq.mm. (Red/Black/ Green) multi strand copper power wire as per IS: 694:2010 or latest, 140 conductor each dia 0.30 mm +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.91 ohms/km and test parameters as per RDSO Specn.No. IRS:S76/89 (Amnd.3) or latest. Color of the wire which is required will be specified by the Engineer in-charge. One Coil should be of 100 meters length | — | — | — | 30,344.94 | |
| — | 4.00 | — | — | ||
| Supply of PVC insulated unsheathed single core bright annealed bare copper conductor flexible cable (Size 16 Sq.mm) for voltage grade up-to 1100V confirming to IS: 694/1990 or latest. It is to be supplied in the coil of 100 meters. | — | — | — | 82,348.56 | |
| — | 2.00 | — | — | ||
| Supply of 1 x 35 Sq.mm. (Red/Black/ Green) multi strand copper power wire as per IS: 694: 2010 or latest, 276 conductor each dia 0.40mm +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 0.554 ohms/km and test parameters as per RDSO Specn.No.IRS: S76/89 (Amnd.3) or latest. Color of the wire which is required will be specified by the Engineer in charge. One Coil should be of 100 meters length. | — | — | — | 98,456.56 | |
| — | 1.00 | — | — | ||
| Supply of Two aspect Colour light signal unit non-metalic complete to RDSO Specification No. RDSO/SPN/194/2006 or latest, made of FRP to RDSO Specification No. RDSO/SPN/151/1997 & IRS:S-26/64 & Drg No. SA-23003A/M (Adv), or all to latest amendments or specifications, without signal transformer, light unit & lenses. | — | — | — | 33,077.31 | |
| — | 1.00 | — | — | ||
| Supply of Colour light signal post tubular steel 140 mm dia, as per IRS 56/81, Length 3.5m - 5.5m long, as per requirement, complete with Signal base as per RDSO drg. S 2011/M, ladder with base, ladder guards platform, MS supporting bracket to support ladder, front staging etc. Front staging platform to be as per site in charge's instruction. | — | — | — | 26,309.65 | |
| — | 1.00 | — | — | ||
| Offset bracket for colour light signal with fixing U clamps and nuts etc for Main Signal as per drawing SA 23080 Adv. or latest | — | — | — | 2,027.39 | |
| — | 2.00 | — | — | ||
| Supply of Shunt signal unit (position light type) non metalic complete to RDSO specification No. RDSO/SPN/ 194/2006 version 1 and RDSO specification no. RDSO/SPN/ 151/1997 for FRP, made of FRP to Drg. No-SA-2384 (Adv) Alt-2 for dependent /independent type complete with signal unit bracket terminals etc but without lense, lamp and lamp holders. | — | — | — | 40,003.02 | |
| — | 2.00 | — | — | ||
| Shunt signal position light post as per specification No- IRS-S-6/81 complete with bracket, post as per IRS-S-6 of 1981 having 4.5 mm thickness & minimum 1 m length surface base etc. | — | — | — | 49,618.48 | |
| — | 2.00 | — | — | ||
| Off set bracket for colour light signal with fixing U clamps and nuts etc. for Shunt /Co- On. | — | — | — | 3,277.08 | |
| — | 1.00 | — | — | ||
| Electric Point Machine: 143 mm stroke, rotary locking type, non-trailable to operate on 110V DC (160 V AC Immunized motor) as per specification No. IRS: S 24-2025, Revision- 3.0 complete set as per technical specification. | — | — | — | 1,19,847.16 | |
| — | 1.00 | — | — | ||
| Ground connections threaded type complete set for 143 mm stroke, Rotary Locking Point Machine, suitable to the point layout of 60 Kg. / 52 Kg Rails as per yard layout for BG and for all make of the Point Machines. | — | — | — | 9,789.46 | |
| — | 1.00 | — | — | ||
| Supply of GI bend pipe for leading cables inside the Point machines. | — | — | — | 1,063.9 | |
| — | 1.00 | — | — | ||
| Points gauge tie plate insulation complete set as per technical specification. | — | — | — | 308.15 | |
| — | 1.00 | — | — | ||
| Point machine ground connection insulation complete set including for P Bracket and L bracket insulation as per IRS: S 40/84 | — | — | — | 657.51 | |
| — | 1.00 | — | — | ||
| Point's William stretcher bar insulation complete set asper technical specification. | — | — | — | 262.28 | |
| — | 1.00 | — | — | ||
| Siemens Point Contactor Unit with base plates and connectors working on 24 V DC conforming to IRS: S-46 and Drg No.RS SK 21/0001B or latest. | — | — | — | 36,280.85 | |
| — | 45.00 | — | — | ||
| Supply of Earth electrode for outdoor equipment as per TS. GI pipe shall consist of spike at one end and a lug at the other for connecting the earth lead wire. | — | — | — | 1,14,306.3 | |
| — | 3.00 | — | — | ||
| Set of complete earthing system, maintenance free tripod type as per RDSO/SPN/ 197/2016 or latest with welded connecting rod and extension, copper cable for connection, Chemical Earthing with ultra-efficient Gel having earth impedance < 1 ohm for filling around earth electrode. It mainly consists of (a) Copper bonded steel electrodes of 3.0 m long, 17.0 mm diameter minimum with copper bonding thickness of min 250 micron and UL listed and marked- 3 No. (b) Earth Enhancement compound of RDSO approved brand supplied in sealed bags of min 10 Kg- 9 Nos. (c) Copper Strip of 200mm x 25mm x 6mm to exothermic welded to Earth electrode- 3 No. (d) Copper Strip of 300mm x 25mm x 6mm (MEEB) - 3 No. (e) Copper Strip of 150 mm x25mm x 6mm (SEEB) - 3 No. | — | — | — | 2,30,087.25 | |
| — | 1.00 | — | — | ||
| Key lock checking relay (KLCR) with D.C. Neutral (AC Immunized) Relay working on 24 V DC for railway Signaling purpose as per RDSO specification number RDSO/SPN/219/2016 version 1.0 with amendment-1. | — | — | — | 16,647.62 | |
| — | 1.00 | — | — | ||
| Supply of EKT rotary type as per IRS-S-21/26 Amd 1 Drg. No. SA-22601 and shall be supplied along with the key. | — | — | — | 5,923.73 | |
| — | 1.00 | — | — | ||
| Supply of LC GATE SMPS based Integrated power supply system (IPS) confirming to RDSO Specn. No. RDSO/ SPN/ 165/2023 version 4.0 amd-1 or latest and as per drawing enclosed for LC GATE in RE Area with 110V/200AH VRLA battery as per IRS:S-93/96 or latest. | — | — | — | 7,61,100 | |
| — | 100.00 | — | — | ||
| Supply of HDPE/DWC pipe outer diameter 200 mm, inner diameter 175 mm for cable protection in trenches. | — | — | — | 65,519 | |
| — | 300.00 | — | — | ||
| Supply of HDPE DWC pipe of size 90/76 mm dia nominal - as per RDSO Specification No. RDSO/SPN/ 204/2011 version 1.1 Amd. 1 or latest TEC Spec. No. with Anti Rodent and Anti- flammable property - along with socket, coupler etc. - as per technical specification and as approved by Engineer-in-charge | — | — | — | 83,601 | |
| — | 200.00 | — | — | ||
| Supply of GI pipe Medium Grade (Class-B) 80 mm dia inside, wall thickness 4.0 mm as per IS: 1239 Part-I (2004) or latest. | — | — | — | 1,59,964 | |
| — | 30.00 | — | — | ||
| Supply of Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC- 77/2012 revision 3 With Amdt.3 or latest. | — | — | — | 1,57,125 | |
| — | 2.00 | — | — | ||
| Supply of cable termination Box and fitting with WAGO Terminal suitable for 6-QUAD Cable with door Locking arrangement to terminate QUAD Cable for Telecom and Signal Circuits as per Technical specification. Make: Safe connect/ Phoenix/Wago. | — | — | — | 24,974.1 | |
| — | 2.00 | — | — | ||
| Supply of VF E&M card, 2W/4W programmable as per clause 7.1 & 7.2 of specification IRS:TC-68/2012 Rev. 0 amend. 1 or latest as per circuit requirement shown in Annexure- subject to minimum of 4 cct per card. Note-It should be compatible with current system. Inspection Authority : Consignee. | — | — | — | 38,207.84 | |
| — | 1.00 | — | — | ||
| Supply of Cat-6E cable as per technical specification. Make: Digisol or D-Link or CP Plus. [Box of 305 Mtr.] | — | — | — | 11,498.69 | |
| — | 5.00 | — | — | ||
| Supply of 12 volts 7 Ah VRLA Battery. Make: Exide/ Amaron /HBL or better. (Inspection Authority : Consignee). | — | — | — | 11,930 | |
| — | 2.00 | — | — | ||
| LED signal lamps for main colour light signals "RED" (Integrated type) for railway signalling, 110VAC, retrofitable in existing CLS housing and compatible with AC LED ECR as per RDSO specification No. RDSO/SPN/199/2010 Rev.1.0. | — | — | — | 19,343.52 | |
| — | 2.00 | — | — | ||
| — | 10.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TD.pdf
ATTACHMENT
GCC-2022-ACSNo.114.07.22.pdf
ATTACHMENT
GCC-2022-ACSNo.213.12.22.pdf
ATTACHMENT
GCC-2022-ACSNo.326.04.23.pdf
ATTACHMENT
GCC-2022-ACSNo.407.08.23.pdf
ATTACHMENT
GCC-2022-ACSNo.520.10.23.pdf
ATTACHMENT
GCC-2022-ACSNo.621.12.23.pdf
ATTACHMENT
GCC-2022-ACSNo.725.09.24.pdf
ATTACHMENT
GCC-2022-ACSNo.820.12.24.pdf
ATTACHMENT
GCC-2022-ACSNo.909.01.25.pdf
ATTACHMENT
GCC-2022-ACSNo.1004.03.25.pdf
ATTACHMENT
ACS-11-GCC-202213.03.26.pdf
ATTACHMENT
ACS-12-GCC-202212.08.26.pdf
ATTACHMENT
GCC-2022.pdf
ATTACHMENT
inspectionofitemRDSO.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .