Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L1 | Accepted-AOC 1st Lowest and reasonable | |
| 2 | L2₹4.0 L+₹26,410 (7.04%)Rejected-AOC STREET NO 10 MALLOMAZRA ROAD BHAKHRA ENCLAVE PATIALA PB | PATIALA | PUNJAB | 140401 | L2 | Rejected-AOC 2d Lowest | |
| 3 | L3₹4.2 L+₹47,224.50 (12.6%)Rejected-AOC 264 2 GALI NO 7 RAM NAGAR ROORKEE DIST HARIDWAR UK | L3 | Rejected-AOC 3rd Lowest | |
| 4 | L4₹4.4 L+₹63,625.50 (17.0%)Rejected-AOC DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-AOC 4th Lowest | |
| 5 | L5₹4.5 L+₹72,254.50 (19.2%)Rejected-AOC PREM NAGAR GALI NO 3 RAJPUTANA SALEMPUR ROORKEE DISTT HARIDWAR UK | ROORKEE | HARIDWAR | UTTARAKHAND | L5 | Rejected-AOC 5th Lowest |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
16 Mar 2021, 6:00 pmClosed
AGE (I) Raiwala
AGE (I) Raiwala Distt dehradun
REPAIR AND REPLACEMENT OF STREET /SECURITY/GATE LIGHTS AND PAINTING OF ELECTRIC POLES IN MD ACCN AT MILI STN RAIWALA UNDER AGE(I) RAIWALA
2021_MES_412037_3
8847/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
RAIWALA
As per tender documents
8 documents required · 8 mandatory
₹500
AGE(I) Raiwala
₹16,000
Yes
6 Apr 2021
3 Mar 2021
19 Mar 2021
3 Mar 2021
16 Mar 2021
4 Mar 2021
Amount
Painting to LT MS tubuler Pole having length 6.5 mtr approx from top of pole with two coats of synthetic enamell aluminium paints and 1.2 mtr height from ground level in alternate band of white and black with synthetic enamel paint complete all as specified and directed.
Taking out of unserviceable LT service/PVC cable of any sizes complete all as specified and directed by Engr-in-Charge.
Taking out /Removing unserviceable / HPSV/MH/FTL fittings and removing the broken GI pipe bracket from the exsiting pole complete all as specified and directed by Engr-in-Charge.
Supply & fixing, 1100 volts grade XLPE heavy duty electric cable with aluminium conductor with following cross section in service connection etc complete all as specified and directed by Engnr-in-Charge.
(a) 6 Sqmm 2 core
(b) 10 Sqmm 2 core
(C) 16Sqmm 2 core
Supply and fixing 45/50W 1500mA, output voltage 24-36V compact LED Driver with surge protection upto 10 to 12 kv, short circuit and open circuit protection isolated, TDH≤10% and power factor ≥0.95 Make :-CG/Havells/C&S
Supply and fixing 60W 5A,constant voltage LED Driver surge protection upto 10 to 12 kv, short circuit and open circuit protection isolated, TDH≤10% and power factor ≥0.95 Make :-CG/Havells/C&S
Supply and fixing 90W 3000mA, compact LED Driver surge protection upto 10 to 12 kv, short circuit and open circuit protection isolated, TDH≤10% and power factor ≥0.95 Make :-CG/Havells/C&S
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter depth and getting out soft / loose soil complete all as specified and directed by Engr-in-Charge.
M&L for filling dry river sand, spread &compacting for sand cushioning of Under ground cable all as specified complete all as specified and directed by Engr-in-Charge.
Supply and laying burnt brick sub class 'B' 23 X 11 X 7.5 cm locally available laid length of brick perpendicular to the length of cable complete all as specified and directed by Engr-in-Charge.
Returning and filling of soil including spreading leveling, watering and ramming in layers not exceeding 25 cm complete all as specified and directed by Engr-in-Charge.
Removing excavated soil to a distance not exceeding 50 meter , not exceeding 1.5 meter above the starting point and depositing where directed complete all as specified and directed by Engr-in-Charge.
S&F Pipe galvanised light grade of size 40mm dia light grade including all fittings laid in trenches and wall and floors etc complete all as specified and directed.
Supply and fixing Digital time switches programmable every 1 min , with backup 6 years , 28 memory locations , current capacity 16 A weekly program , with cangeover ( 1CO total 28 programs complete all as specefied and as directed by engr -in- charge. Make:- Indoasian Model No DIN Type Daily / weekly with 1 CO Cat part no TDA43110 or equivalent make in Legrand / hager.
Supply and fixing street light junction box IP -43 all weather proof non corrosive including 30 Amp MCB SPN and provisoin of fixing digital timer switch complete all as specefied and as directed by engr -in- charge. Make:- Sintex/Havells/crompton/Bajaj
Supply and fix LED street/security light fitting 45 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP - 66 protection, working on 240 volt, 50 HZ, consisting of reflective lens wired with approximate driver PF > 0.98 having over voltage protection upto 440 volts, surge protection level > 10 kV, thermal short circuit protection THD < 10 % made of long life LED chips (SMD) in modular with Ra > 70, and LED lumen efficiency > 100 lumen per watt, beam angle along the drive way, 80 degree luminior efficiency > 100 Lumen/ watt power LED should be more than 01 watt CCT should be between 5700 K - 6500 K including fixed on pole with 02 Nos MS clamp made of 40 X6 mm F1 and bracket made out of 40 mm dia light grade GI pipe not less than 1.2 mtr long bend to shape including connecting with 1.5 sq mm, 3 core , PVC insulated copper conductor cable1100 volt grade all as specified and as directed by Engr-in- Charge Make: Shakti Cat Part No : SZPSLPM045 or equivalent model in Havells/ Wipro (i) the firm has to give warranty for street light fittings including driver for 03 years for any defect developed during the period. (ii) The contractor shall submit the the third party LM 79 report from any NABL approved laboratory. (iii) The fitting should have BIS, CRS
gurchan singh & sons.
KISHORE CHAND DINESH CHAND
TARUN ENGINEERING WORKS
M/S Konark Electric Sales Corporation
janta tradrers
AJAY KUMAR CONTRACTOR
SIDDHARTH TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .